Kamoer X2SR Water Change System User Manual
- June 6, 2024
- Kamoer
Table of Contents
Kamoer X2SR Water Change System
Reading tips
FCC warning
This device has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This device generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this device does cause harmful interference to radio or
television reception, which can be determined by turning the device off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: –Reorient or relocate the receiving antenna.
–Increase the separation between the device and receiver. –Connect the device
to an outlet on a circuit different from that to which the receiver is
connected. –Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment FCC
Radiation Exposure Statement The antennas used for this transmitter must be
installed to provide a separation distance of at least 20 cm from all persons
and must not be co-located for operating in conjunction with any other antenna
or transmitter.
Recommendations
Kamoer provides users with the following documents:
- 《X2S R User Manual》
- 《X2S R Quick Start Guide》
Download Kamoer Remote App
- Scan the QR code to download the application corresponding to the following icon.
Apple users enter the App Store, and Android users enter Tencent App Store, search for “kamoer remote”, and find the application download with the corresponding icon Kamoer Remote App supports Android 4.4 and above systems and supports iOS 9.1 and above systems.
Get the tutorial
After installing the App, open it, click the question mark icon in the
upper right corner of the device list page to view the tutorial, including the
user manual and answers to common questions.
product description
Introduction
X2S R is a dual-channel WiFi water change pump. The user can remotely
control it through the mobile phone App. The user can use the X2S R to
automatically change the water in their own sea or freshwater tanks at a fixed
time and quantitatively. The submersible pump interface can complete the
automatic water replenishment function. In response to possible overflow
risks, X2S R is equipped with an anti-overflow sensor as standard. When the
water level reaches the anti-overflow sensor, it will trigger an alarm and
stop the water supply and change. X2S R is equipped with two stepping pumps,
which can be used continuously for a long time.
Feature highlights
- The water change pump adopts a stepping motor, which has longer service life and more accurate operation
- Standard Pharmed BPT imported pump tube, long life, heat resistance, acid and alkali resistance, ozone and UV rays resistance, aging and oxidation resistance
- Contains a real-time clock, automatically runs according to the set parameters, and the parameters are not lost when power off
- Support two automatic water change modes: first row and then enter and side row and side enter
- Support manual and planned quantitative water change, and the water change pump supports flow adjustment
- A water change plan can be set up to 24 times a day, supporting 1-99 days of circulating water change
- Support flow calibration, drainage and make-up water flow correction
- Support iOS and Android devices to remotely control the Dosing pump via WiFi, and support App to upgrade the Dosing pump firmware Support push alerts such as overflow and replenishment timeout
Application occasion
- Seawater tank
- Including bony corals (SPS), soft corals (LPS) and polyculture corals (SPS/LPS).
- Freshwater tank
- Freshwater fish tank, grass tank
- Other occasions where water needs to be changed
Unpacking preparation
- Before opening the packaging box, check whether the outer packaging is damaged during transportation.
- After opening the packing box, refer to the packing list in the appendix, confirm that all parts are not missing, and check for visible damage. If you find any defects during unpacking, please contact the manufacturer immediately.
**Part Name
**
- The outlet of the drainage pump, Connect the wastewater bucket
- The water inlet of the drainage pump, connected to the fish tank
- Make up the water outlet of the seawater pump and connect to the fish tank
- The intake of the seawater pump is connected with fresh seawater
- _0C 24V output, connected with make-up freshwater submersible pump
- Replenish the level sensor of the freshwater tank to identify the water-free alarm
- Wastewater tank level sensor to identify full water alarm
- Prevent overflow sensor to identify water level overflow alarm in a fish tank
- Liquid level sensor to identify water level drop and makeup water automatically
- “Reset”Reset button for distribution network use
- DC 24V IN, power input
- 0peration indicator of wastewater pump
- Running indicator of sea make-up water pump
- Discharge the seawater pump button, Press the pump to run
- Make up the fresh seawater pump button, Press the pump to run
- The power I WiFi status indicator
Pipeline connection diagram
Click on the device on the home page of the device list to enter the X2S R
status display page. On the status display page, click the information button
in the upper right corner to view the water change pipeline connection diagram
and sensor connection diagram
Status indicator description
The STATE on the top panel of the device is a combination of a power indicator
and WiFi status indicator.
Status indicator (green)
Status | Description |
---|
The green status light keeps on
| The device is in the mode of connecting to the router, and the App controls the device by connecting to the router
The green status light is off
| The device is in direct connection mode, and the App controls the device through the connected device WiFi
The green status light flashes quickly
| In the network configuration mode, the App can configure the Dosing pump to
connect to the router 1
The green status light is on for 200ms and off for 2 seconds| AP network
configuration mode, at this time APP can configure the device to access the
router through the device hotspot
The green status light flashes slowly| The device is in router mode, but the
device is not successfully connected to the router
Power indicator (red)
Status| Description|
---|---|---
Long bright| Powered on|
Off| No power supply or power failure|
Pump running indicator:
PUMP1 and PUMP2 are pumps running indicator lights. When the pump is
running, the pump running indicator is on, and when the pump stops, the pump
running indicator is off.
Pump operation button:
The two buttons on the front panel of the device are pump operation
buttons. When the button is pressed, the corresponding pump runs, and when the
button is lifted, the corresponding pump stops.
App use
This chapter mainly introduces how to use Kamoer Remote App to control X2S R water exchange pump.
App connection device
Connect the device to the online
There are two ways to connect App configuration devices to the cloud, one
is AP network configuration mode (recommended), and the other is route
distribution network mode. Open the Kamoer Remote App, after registering the
App account, go to the device homepage, click the Add Device button in the
upper right corner to enter the process of connecting the device to the cloud,
and follow the App prompts to complete the network configuration
operation:
App home page overview
- Automatic water change: The status display page, here mainly presents the equipment status, including the working mode of water change, the status of each sensor, the status of the solution tank, the status of pump operation, etc.
- Water change: Here is mainly for manual or automatic water change settings.
- Settings: This includes functions such as device serial number viewing, device upgrade, time synchronization, speed setting, calibration, and factory reset.
Home Status Information
-
Manual water change/automatic water change:The water change status display can be switched in the title bar of the water change module.
-
Liquid level sensor:The liquid level sensor that decides whether to replenish freshwater. When the water in the cylinder is low and the float is lower than the page, the automatic water replenishment will start until the page returns to the float position;
-
Anti-overflow sensor: When the liquid level sensor is broken and the water is refilled, the water level will continue to rise until the anti-overflow sensor. At this time, the device will send an alarm to the mobile phone and stop the current automatic water replenishment;
-
Waste liquid sensor: When it recognizes that the water level of the wastewater bucket is full, send an alarm to the App;
-
Freshwater sensor: When it recognizes that the freshwater bucket is empty, it sends an alarm to the App;
-
Wastewater bucket: Identify whether the wastewater bucket is full, click to set the volume of the wastewater bucket
-
Seawater bucket: Identify the volume of the seawater bucket and click to set the volume of the seawater bucket
-
Drain pump working status: Display the working status of the drain pump;
-
The working status of the makeup pump Shows the working status of the makeup pump
-
Piping connection diagram and sensor connection diagram View and set the status of wastewater bucket and fresh seawater bucket
-
1Waste water bucket: The water change pump drains to the wastewater bucket, which has a volume. When the drainage volume continues to increase to more than 90% of the volume of the wastewater bucket, an alarm is generated to prompt to empty the wastewater bucket.
-
Fresh seawater bucket: The fresh seawater bucket has a volume. When the water is changed to less than 10% of the volume, an alarm will be generated to remind you to add water.
-
Monitor the liquid level: After the switch is turned on, an alarm will be sent when an alarm is generated.
-
Volume: Volume setting of wastewater bucket and fresh seawater bucket.
Change water manually
When you need to change the water manually, you can switch to the manual
water change mode in the title bar of the water change module
- Manual water change: Here to switch between manual water change and automatic water change
- Drainage: Control the running and stopping of the drain pump, click to enter to set a running volume, and the function of automatically replenishing water after draining
- Seawater supplement: Control the operation and stop of the seawater supplement pump, click to enter to set a running volume
- Make-up freshwater: Control the operation and stop of the make-up fresh water pump, click to enter to set a running volume
- Operating volume: The pump operating volume setting, the pump will automatically stop after it reaches the operating volume after it starts running manually
- Automatic water replenishment after draining:This function is to automatically start the water replenishment pump after the drain pump work is completed. The default water replenishment pump and the drain water pump run the same amount
Automatic water change
When you need to change the water automatically, you can switch to the
automatic water change mode in the title bar of the water change
module
-
Automatic water change:::Here to switch between manual water change and automatic water change
-
Cylinder volume:Set the volume of the water body of your own tank to facilitate the calculation of the water change ratio when setting the plan
-
Operation mode:The operation mode has two water change modes: edge-in and edge-out and first-out and then-in. The edge-in and edge-out mode can keep the water level change little when changing water, but some fresh seawater will be discharged. The water level will change when the water is changed in the first-out-last-in mode, but fresh seawater will not be discharged
-
Cycle date:Set the water change cycle, there are two ways: cycle by week and cycle by operating days
-
Automatic water change switch setting:Automatic water change switch, turn on the automatic water change switch, the automatic water change will proceed as planned, turn off the automatic water change switch, the automatic water change will not proceed
-
Add plan:Add water change plan, here you can add plans one by one, or you can quickly add multiple plans at once, up to 24 plans can be added
-
Total amount of water exchange:Total amount of water exchange plan
8. Water change ratio:The water change ratio is calculated by dividing the planned water change by the volume of water in the tank -
Start time:Planned start time
-
Water exchange volume:Planned water exchange volume
-
End time:The planned end time calculated based on the start time and the water change volume
-
Save the plan:: Save the water change plan Quick add plan Quick plan can quickly add multiple plans at once
-
Add a quick plan:Click Add to enter the quick plan adding interface
-
Start time:Set the start time period of the quick plan
-
End time:::Set the end time period of the quick plan
-
Number of plans:Set the number of plans
-
Cylinder volume:The volume of the previously set cylinder
-
Total amount of water exchange:The total amount of water exchange will be evenly distributed to each plan
-
Water exchange ratio:Total amount of water exchange divided by the volume of the tank is obtained
-
Plan preview:he plan preview obtained according to the parameters set above
-
Save:Save the set quick plan
Container
The user of the container module records the changes of the user’s water
supply bucket and wastewater bucket to help users understand the status of the
water supply bucket and waste water bucket;
- Container module;
- Waste water bucket:The water volume of the waste water bucket. When the volume of the waste water bucket is greater than 90%, the waste water bucket will have a color alarm that the waste water bucket is full;
- Water supply bucket:The water volume of the water supply bucket. When the water volume of the water supply bucket is less than 10%, the water supply bucket will have a color alarm of insufficient water volume in the water supply bucket;
- Waste water tank volume:Waste water tank volume setting and display;
- Volume of water refill bucket:Set and display volume of water refill bucket;
- Settings: Click to enter the container setting interface;
- Waste water detection switch: After opening, when the water change plan is executed, the volume of the waste water bucket is updated;
- Water replenishment detection switch: After turning on, the volume of water in the replenishing bucket will be updated when the water change plan is in progress;
Settings
The setting module mainly includes functions such as device information
viewing, flow rate calibration, firmware upgrade, and time synchronization.
- Device name and version:View device name and version
- Name:Set the name of the device
- Serial number:View device serial number
- Firmware upgrade:If a new firmware version appears, you can upgrade the firmware here
- Time setting:If the scheduled time of the device operation is not accurate, you can synchronize the time here
- Connect to the smart controller:Set the device to connect to the Kamoer smart controller, this function is temporarily not supported
- Speed setting: Perform flow rate calibration here
- Restore factory settings: Click to restore factory settings
- Remove device:Click to remove the binding between App and device
Calibration
When it is found that the water change flow is inaccurate, it is necessary
to calibrate the flow of the water change pump, and enter the flow calibration
interface of the water change pump through Settings -> Flow Rate Setting ->
Flow Calibration. Calibration requires a measuring cylinder to be used to
weigh the calibration results.
Note: During calibration, do not use the water in the tank for calibration.
Using the water in the tank for calibration may cause the water level in the
tank to drop. X2S R will automatically add fresh water to the tank.
- Rotation speed:The rotation speed setting of the water change pump is calibrated according to the actual rotation speed in use.
- Start emptying:Click to start emptying to empty the air in the pump tube
- Calibration duration:Set the calibration duration. In theory, the longer the time, the better the calibration effect, but the size of the graduated cylinder must be considered
- Start calibration:Click to start calibration
- Enter the volume:When the calibrated pump runs, enter the volume obtained from the run into the App
- Calibration completed:Click to complete calibration
Change water correction After the calibration of the water replacement pump head is completed, it is necessary to correct the deviation of the lower drainage pump and the makeup pump to ensure that the outlet and inlet water are the same when changing the water. The principle of correcting the drainage and makeup is to change the water once. How much is the difference between the amount of water replenishment, this difference is the amount that needs to be corrected for drainage and water replenishment, enter this amount into the App to complete the correction The water change correction needs to be calibrated for each pump first in the flow rate calibration Enter the water change correction process through Settings -> Flow Rate Setting -> Change Water Correction, and complete the correction according to the App prompt process
Appendix
Technical Parameters
- Dimensions (length x width x height) 168x177x223mm (including pump head)
- Weight 4106 grams (not including power adapter)
- Power Adapter
- Input: 100VAC -240VAC
- Output: DC24V 1.9A
- Titration parameters
- Water change pump: 2 KHL-B24 pump heads
- Submersible pump: automatic water replenishment
- Flow rate: >1000 ml/min
- Automatic water change: 24 times/day-1 time/99 days
- Liquid level sensor with water replenishment function
- Anti-overflow level sensor
- Filling water tank level sensor
- Waste liquid tank level sensor
- Interface WIFI communication interface
- Working environment Temperature 0-70℃, humidity 10%-90% (non-condensing)
- Storage environment Temperature -20℃-85℃, humidity 10%-90% (non-condensing)
After-sales warranty information
Warranty conditions
The free service during the warranty period is only valid under normal use
and maintenance according to the user manual, and all man-made faults or
damages are not covered by the warranty. Users please keep the purchase
invoice and user manual properly so that you can get satisfactory after-sales
service in time.
Warranty coverage
Within one year from the date of purchase, if there is any damage caused by
the manufacturing process or components, the company will provide free
warranty service.
Non-warranty coverage
The following factors are not within the scope of the free warranty, and
customer repairs need to pay for it. 1)Product appearance (please confirm when
purchasing); 2)Improper use, maintenance or storage (please follow the user
manual for proper use, maintenance and storage); 3)Connect to improper power
supply; 4)Damage to the components caused by the short circuit of the circuit
board caused by various insects entering the machine; 5)Loss caused by
accident; 6)Use inappropriate parts (not applicable to parts other than our
company); 7)Negligence handling, modification or repair by personnel not
authorized by the company (please do not disassemble or repair without
authorization); 8)Failure or damage caused by use outside of applicable
occasions; 9)Damage caused by force majeure, etc.; 10)Consumption and wearing
parts (such as pH electrode, ORP electrode, etc.); 11)The warranty period has
expired.
Kamoer, the words, and icons of Kamoer have registered trademarks of Kamoer
Fluid Tech (Shanghai) Co., Ltd. The company reserves the right to improve and
change the appearance and technical specifications of the product without
prior notice.
Read User Manual Online (PDF format)