makita AF601 Pneumatic Finish Nailer Instruction Manual
- June 5, 2024
- Makita
Table of Contents
- SPECIFICATIONS
- Symbols
- Intended use
- Noise
- Vibration
- EC Declaration of Conformity
- SAFETY WARNINGS
- SAVE THESE INSTRUCTIONS.
- PARTS DESCRIPTION
- INSTALLATION
- Selecting air hose
- Lubrication
- FUNCTIONAL DESCRIPTION
- ASSEMBLY
- Dimensions of fasteners
- Removing nails
- Nose adapter
- Connecting air hose
- OPERATION
- Checking proper action before the operation
- Single sequential actuation
- Contact actuation
- Anti-dry fire mechanism
- MAINTENANCE
- Nails
- Maintenance of nailer
- Maintenance of compressor, air set, and air hose
- OPTIONAL ACCESSORIES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Pneumatic Finish Nailer
INSTRUCTION MANUAL
SPECIFICATIONS
Model: | AF601 |
---|---|
Air pressure | 0.49 -0.83 MPa (4.9 – 8.3 bar) |
Nail length | 25 mm – 64 mm |
Nail capacity | 100 pcs. |
Minimum hose diameter | 6.5 mm |
Pneumatic tool oil | ISO VG32 or equivalent |
Dimensions (L x W x H) | 304 mm x 95 mm x 297 mm |
Net weight | 1.7 kg |
- Due to our continuing program of research and development, the specifications herein are subject to change without notice.
- Specifications may differ from country to country
Symbols
The followings show the symbols used for the equipment. Be sure that you understand their meaning before use.
| Read the instruction manual.
---|---
| Wear safety glasses
| The tool has the capability of operating in
contact actuation mode.
| Wear ear protection.
| Do not use scaffoldings or ladders.
Intended use
The tool is intended for fastening on interior work and furniture work. The tool is for high-volume professional applications only. Do not use it for any other purpose. It is not designed to drive fasteners on a hard surface like steel and concrete.
Noise
The typical A-weighted noise level determined according to ISO11148-13 (EN12549): Sound pressure level (LpA) : 104 dB(A) Sound power level (LWA) : 115 dB (A) Uncertainty (K) : 1.5 dB(A)
NOTE: The declared noise emission value(s) has been measured in
accordance with a standard test method and may be used for comparing one tool
with another.
NOTE: The declared noise emission value(s) may also be used in a
preliminary assessment of exposure.
WARNING: Wear ear protection.
WARNING: The noise emission during actual use of the power tool can
differ from the declared value(s) depending on the ways in which the tool is
used especially what kind of workpiece is processed.
WARNING: Be sure to identify safety measure to protect the operator that
is based on an estimation of exposure in the actual conditions of use (taking
account of all arts of the operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the trigger time).
Vibration
The vibration total value determined according to ISO11148-13 (ISO8662-11)
Vibration emission (ah) : 6.8 m/s 2
Uncertainty (K) : 1.5 m/s2
NOTE: The declared vibration total value(s) has been measured in
accordance with a standard test method and may be used for comparing one tool
with another.
NOTE: The declared vibration total value(s) may also be used in a
preliminary assessment of exposure.
WARNING: The vibration emission during actual use of the power tool can
differ from the declared value(s) depending on the ways in which the tool is
used especially what kind of workpiece is processed.
WARNING: Be sure to identify safety measures to protect the operator that
is based on an estimation of exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as the times when the tool is
switched off and when it is running idle in addition to the trigger time).
EC Declaration of Conformity
For European countries, only The EC declaration of conformity is included as Annex A to this instruction manual.
SAFETY WARNINGS
Pneumatic nailer/stapler safety warnings
WARNING: Read all safety warnings and all instructions. Failure to follow
the warnings and instructions may result in serious injury, electric shock,
and/or fire.
Save all warnings and instructions for future reference. For personal safety and proper operation and maintenance of the tool, read this instruction manual before using the tool. General safety
- Any other use except for the intended use of this tool is forbidden. Fastener driving tools with continual contact actuation or contact actuation shall only be used for production applications.
- . Keep fingers away from the trigger when not operating this tool and when moving from one operating position to another.
- . Multiple hazards. Read and understand the safety instructions before connecting, disconnecting, loading, operating, maintaining, changing accessories on, or working near the tool. Failure to do so can result in serious bodily injury.
- . Keep all body parts such as hands and legs etc. away from the firing direction and ensure the fastener cannot penetrate the workpiece into parts of the body.
- When using the tool, be aware that the fastener could deflect and cause injury.
- Hold the tool with a firm grasp and be prepared to manage recoil.
- Only technically skilled operators should use the fastener driving tool.
- Do not modify the fastener driving tool. Modifications may reduce the effectiveness of safety measures and increase the risks to the operator and/or bystander.
- Do not discard the instruction manual.
- Do not use a tool if the tool has been damaged.
- Be careful when handling fasteners, especially when loading and unloading, as the fasteners have sharp points which could cause injury.
- Always check the tool before use for broken, disconnected, or worn parts.
- Do not overreach. Only use in a safe working place. Keep proper footing and balance at all times.
- Keep bystanders away (when working in an area where there is a likelihood of traffic of people). Clearly mark off your operating area.
- Never point the tool at yourself or others.
- Do not rest your finger on the trigger when picking up the tool, moving between operating areas and positions, or walking, as resting your finger on the trigger can lead t inadvertent operation. For tools with selective actuation, always check the tool before use to ascertain the correct mode is selected.
- Only wear gloves that provide an adequate feel and safe control of triggers and any adjusting devices.
- When resting the tool, lay it down on a flat surface. If you use the hook equipped with the tool, hook the tool securely on the stable surface.
- Do not operate when under the influence of alcohol, drugs, or the like.
Projectile hazards
- The fastener driving tool shall be disconnected when unloading fasteners, making adjustments, clearing jams, or changing accessories.
- During operation be careful that fasteners penetrate material correctly and cannot be deflected/misfired towards the operator and/or any bystanders
- During operation, debris from the workpiece and the fastening/collation system may be discharged.
- Always wear protective goggles to protect your eyes from injury when using power tools. The goggles must comply with ANSI Z87.1 in the USA, EN 166 in Europe, or AS/NZS 1336 in Australia/New Zealand. In Australia/New Zealand, it is legally required to wear a face shield to protect your face, too.
It is an employer’s responsibility to enforce the use of appropriate safety protective equipment by the tool operators and by other persons in the immediate working area.
-
The risks to others shall be assessed by the operator
-
Be careful with tools without workpiece contact as they can be fired unintentionally and injure the operator and/or bystander.
-
Ensure the tool is always safely engaged on the workpiece and cannot slip.
-
Wear hearing protection to protect your ears against exhaust noise and head protection. Also, wear light but not loose clothing. Sleeves should be buttoned or rolled up. No necktie should be worn.
Operating hazards
- Hold the tool correctly: be ready to counteract normal or sudden movements such as recoil.
- Maintain a balanced body position and secure footing
- Appropriate safety glasses shall be used and appropriate gloves and protective clothing are recommended
- Appropriate hearing protection shall be worn.
- Use the correct energy supply as directed in the instruction manual.
- Do not use the tool on moving platforms or back of trucks. The sudden movement of the platform may lose control of the tool and cause injury.
- Always assume that the tool contains fasteners.
- Do not rush the job or force the tool. Handle the tool carefully.
- Watch your footing and maintain your balance with the tool. Make sure there is no one below when working in high locations, and secure the air hose to prevent danger if there is sudden jerking or catching.
- On rooftops and other high locations, drive fasteners as you move forward. It is easy to lose your footing if you drive fasteners while inching backward. When driving fasteners against the perpendicular surface, work from the top to the bottom. You can perform driving operations with less fatigue by doing so. fatigue by doing so.
- A fastener will be bent or the tool can become jammed if you mistakenly drive the fastener on top of another fastener or strike a knot in the wood. The fastener may be thrown and hit someone, or the tool itself can react dangerously. Place the fasteners with care.
- Do not leave the loaded tool or the air compressor under pressure for a long time out in the sun. Be sure that dust, sand, chips, and foreign matter will not enter the tool in the place where you leave it sitting.
- Never attempt to drive fasteners from both inside and outside at the same time. Fasteners may rip through and/or fly off, presenting a grave danger.
Repetitive motions hazards
- When using a tool for long periods, the operator may experience discomfort in the hands, arms, shoulders, neck, or other parts of the body.
- While using a tool, the operator should adopt a suitable but ergonomic posture. Maintain secure footing and avoid awkward or off-balanced postures.
- If the operator experiences symptoms such as persistent or recurring discomfort, pain, throbbing, aching, tingling, numbness, burning sensation, or stiffness, do not ignore these warning signs. The operator should consult a qualified health professional regarding overall activities.
- The continuous use of the tool may cause repetitive strain injury due to recoil produced by the tool.
- To avoid repetitive strain injury, the operator should not overreach or use excessive force. Additionally, the operator should take a rest when feeling fatigued.
- Conduct a risk assessment regarding repetitive motion hazards. It should focus on muscular-skeletal disorders and be preferentially based on the assumption that decreasing fatigue during work is effective in reducing disorders.
Accessory and consumable hazards
- Disconnect the energy supply to the tool, such as air or gas or battery as applicable, before changing/replacing accessories such as workpiece contact, or making any adjustments.
- Use only the sizes and types of accessories that are provided by the manufacturer.
- Use only lubricants recommended in this manual.
Workplace hazards
- Slips, trips, and falls are major causes of workplace injury. Be aware of slippery surfaces caused by the use of the tool and also of trip hazards caused by the air line hose.
- Proceed with additional care in unfamiliar surroundings. Hidden hazards may exist, such as electricity or other utility lines.
- This tool is not intended for use in potentially explosive atmospheres and is not insulated from coming into contact with electric power.
- Make sure there are no electrical cables, gas pipes, etc. that could cause a hazard if damaged by the use of the tool.
- Keep the work area clean and well-lit. Cluttered or dark areas invite accidents.
- There may be local regulations concerning noise that must be complied with by keeping noise levels within prescribed limits. In certain cases, shutters should be used to contain noise.
Dust and exhaust hazards
- Always check your surroundings. The air exhausted from the tool may blow dust or objects and hit the operator and/or bystanders.
- Direct the exhaust so as to minimize disturbance of dust in a dust-filled environment
- If dust or objects are emitted in the work area, reduce the emission as much as possible to reduce the health hazards and risk of injury.
Noise hazards
- Unprotected exposure to high noise levels can cause permanent, disabling, hearing loss and other problems such as tinnitus (ringing, buzzing, whistling or humming in the ears)
- Conduct a risk assessment regarding noise hazards in the work area and implement appropriate controls for these hazards.
- Appropriate controls to reduce the risk may include actions such as damping materials to prevent workpieces from “ringing”
- Use appropriate hearing protection.
- Operate and maintain the tool as recommended in these instructions, to prevent an unnecessary increase in noise levels.
- Take noise reduction measures, for example placing workpieces on sound damping supports.
Vibration hazards
- The vibration emission during operation depends on the gripping force, the contact pressure force, the working direction, the adjustment of energy supply, the workpiece, and the workpiece support. Conduct a risk assessment regarding vibration hazards and implement appropriate controls for these hazards.
- Exposure to vibration can cause disabling damage to the nerves and blood supply of the hands and arms.
- Wear warm clothing when working in cold conditions, and keep your hands warm and dry.
- If you experience numbness, tingling, pain, or whitening of the skin in your fingers or hands, seek medical advice from a qualified occupational health professional regarding overall activities.
- Operate and maintain the tool as recommended in these instructions, to prevent an unnecessary increase in vibration levels.
- Hold the tool with a light, but safe, grip because the risk from vibration is generally greater when the grip force is higher.
Additional warnings for pneumatic tools
- Compressed air can cause severe injury.
- Always shut off the air supply, and disconnect the tool from the air supply when not in use.
- Always disconnect the tool from the compressed air supply before changing accessories, making adjustments and/or repairs, when moving away from an operating area to a different area.
- Keep fingers away from the trigger when not operating the tool and when moving from one operating position to another.
- Never direct compressed air at yourself or anyone else.
- Whipping hoses can cause severe injury. Always check for damaged or loose hoses or fittings.
- Never carry a pneumatic tool by its hose.
- Never drag a pneumatic tool by its hose.
- When using pneumatic tools, do not exceed the maximum operating pressure ps max.
- . Pneumatic tools should only be powered by compressed air at the lowest pressure required for the work process to reduce noise and vibration and minimize wear.
- Using oxygen or combustible gases for operating pneumatic tools creates a fire and explosion hazard.
Be careful when using pneumatic tools as the tool could become cold, affecting grip and control. Additional warnings for tools with contact actuation capability
- Do not rest your finger on the trigger when picking up the tool, moving between operating areas and positions, or walking, as resting your finger on the trigger can lead to inadvertent operation. For tools with selective actuation, always check the tool before use to ascertain the correct mode is selected.
- This tool has either selective actuation for contact actuation or continuous contact actuation by actuation mode selectors or is a contact actuation or continuous actuation contact tool and has been marked with the symbol above. Its intended uses are for production applications such as pallets, furniture, manufactured housing, upholstery, and sheathing.
- If using this tool in selective actuation mode, always ensure it is in the correct actuation setting.
- Do not use this tool in contact actuation for applications such as closing boxes or crates and fitting transportation safety systems on trailers and lorries.
. Be careful when changing from one driving location to another.
Safety devices
- Make sure all safety systems are in working order before operation. The tool must not operate if only the trigger is pulled or if only the contact arm is pressed against the wood. It must work only when both actions are performed. Test for possible faulty operation with fasteners unloaded and the pusher in a fully pulled position.
- Securing the trigger in the ON position is very dangerous. Never attempt to fasten the trigger.
- Do not attempt to keep the contact element depressed with tape or wire. Death or serious injury may occur.
- Always check the contact element as instructed in this manual. Fasteners may be driven accidentally if the safety mechanism is not working correctly
Service
- Perform cleaning and maintenance right after finishing the job. Keep the tool in tip-top condition. Lubricate moving parts to prevent rusting and minimize friction-related wear. Wipe off all dust from the parts.
- Ask Makita’s authorized service center for a periodical inspection of the tool.
- To maintain product SAFETY and RELIABILITY, maintenance and repairs should be performed by Makita Authorized Service Centers, always using Makita replacement parts.
- Follow local regulations when disposing of the tool.
SAVE THESE INSTRUCTIONS.
WARNING: DO NOT let comfort or familiarity with the product (gained from repeated use) replace strict adherence to safety rules for the subject product. MISUSE or failure to follow the safety rules stated in this instruction manual may cause serious personal injury.
PARTS DESCRIPTION
► Fig.1: 1. Trigger 2. Nose adapter (contact element) 3. Hook 4. Magazine
INSTALLATION
Selecting compressor
1. Nailing frequency (times/min) 2. Compressor air
output per minute (L/min) 3. 0.83 MPa (8.3 bar) 4. 0.66
MPa (6.6 bar) 5. 0.49 MPa (4.9 bar)
The air compressor must comply with the requirements
of EN60335-2-34.
Select a compressor that has ample pressure and air output to assure cost-
efficient operation. The graph shows the relation between nailing frequency,
applicable pressure, and compressor air output.
Thus, for example, if nailing takes place at a rate of approximately 60 times per minute at a compression of 0.66 MPa (6.6 bar), a compressor with an air output over 80 liters/minute is required. Pressure regulators must be used to limit air pressure to the rated pressure of the tool where air supply pressure exceeds the tool’s rated pressure. failure o may so result in serious injury to the tool operator or persons in the vicinity.
Selecting air hose
CAUTION: Low air output of the compressor, or a long or smaller diameter
air hose in relation to the nailing frequency may cause a decrease in the
driving capability of the tool.
► Fig.2
Use an air hose as large and as short as possible to assure continuous, efficient nailing operation. With an air pressure of 0.49 MPa (4.9 bar), an air hose with an internal diameter of over 6.5 mm and a length of less than 20 m is recommended when the interval between each nailing is 0.5 seconds. Air supply hoses shall have a minimum working pressure rating of 1.03 MPa (10.3 bar) or 150 percent of the maximum pressure produced in the system whichever is higher.
Lubrication
► Fig.3
To ensure maximum performance, install an air set (oiler, regulator, air
filter) as close as possible to the tool. Adjust the oiler so that one drop of
oil will be provided for every 50 ails. When an air set is not used, oil the
tool with pneumatic tool oil by placing 2 (two) or 3 (three) drops into the
air fitting. This should be done before and after use. For proper lubrication,
the tool must be fired a couple of times after pneumatic tool oil is
introduced.
► Fig.4: 1. Pneumatic tool oil
FUNCTIONAL DESCRIPTION
CAUTION : Before adjusting or checking the function on the tool, always
release the trigger and disconnect the air hose from the tool.
Adjusting the depth of nailing
► Fig.5: 1. Adjuster To adjust the depth of nailing, turn the adjuster. The
depth of nailing is the deepest when the adjuster is turned fully in the A
direction shown in the figure. It will become shallower as the adjuster is
turned in the B direction. If nails cannot be driven deep enough even when the
adjuster is turned fully in the A direction, increase the air pressure. If
nails are driven too deep even when the adjuster is turned fully in the B
direction, decrease the air pressure. Generally speaking, the tool service
life will be longer when the tool is used with lower air pressure and the
adjuster set to a deeper depth of nail driving.
Hook
CAUTION: Never hook the tool at a high location or on a potentially
unstable surface.
CAUTION: Do not hang the hook from the waist belt. If the nailer
accidentally drops, it may result in misfiring and personal injuries.
► Fig.6: 1. Hook The hook is convenient for hanging the tool temporarily.
Air duster
CAUTION: Do not aim the ejection port of the air duster at someone. Also,
keep your hands and foot away from the ejection port. If the air duster button
is accidentally pushed, it may cause a personal injury.
CAUTION: Always check your surroundings before using the air duster.
Blown dust or objects may hit someone.
CAUTION: Do not connect or disconnect the air hose while pushing the air
duster button. The air supplied to the tool can also be used as an air duster.
You can clean the work area by pressing the button on the grip end.
► Fig.7: 1. Button
NOTICE: After using the air duster, the driving force of the tool will
temporarily decline. Wait until the air pressure recovers in this case.
NOTICE: Perform a test blow if you use the air duster immediately after
the oil was applied. The oil may be sprayed with the air.
ASSEMBLY
CAUTION : Before carrying out any work on the tool, always release the
trigger and disconnect the air hose from the tool.
CAUTION: Load the same type, size, and uniform length of nails when
loading nails in the magazine.
Loading nailer
-
Pull the pusher lever until it is locked at the magazine end.
► Fig.8: 1. Pusher lever -
Insert a strip of nails into the slit in the rear of the magazine and push the strip toward the firing opening.
► Fig.9: 1. Magazine -
By pushing the pusher button, return the pusher lever to the end of the strip gently.
► Fig.10: 1. Pusher button 2. Pusher lever
CAUTION: Always hold the pusher lever when you press the pusher button to return the pusher lever, otherwise the pusher lever suddenly returns, it may cause personal injury.
Dimensions of fasteners
Only the following fasteners can be used with the tool.
16 Gauge finish nails
► Fig.11 Maximum
► Fig.12: (1) 64 mm Minimum
► Fig.13: (1) 2.8 mm (2) 1.6 mm (3) 1.2 mm (4) 25 mm (5) 1.4 mm
Removing nails
- Pull the pusher lever until it is locked at the magazine end.
- Slide the nails toward the rear of the magazine and remove them.
Nose adapter
To prevent the surface of the workpiece from being scratched or damaged, use
the nose adapter.
► Fig.14: 1. Nose adapter 2. Contact element A spare nose adapter is stored in
the place shown in the figure.
► Fig.15: 1. Spare nose adapter
Connecting air hose
CAUTION: Do not rest your finger on the trigger when connecting the air
hose.
► Fig.16: 1. Air fitting 2. Air socket Slip the aerial socket of the air hose
onto the air fitting on the tool. Be sure that the air socket locks firmly
into position when installed onto the air fitting. A hose coupling must be
installed on or near the tool in such a way that the pressure reservoir will
discharge at the time the air supply coupling is disconnected.
OPERATION
CAUTION: Make sure all safety systems are in working order before
operation. Selecting the operation mode
CAUTION : Always make sure that the actuation mode selector is properly
set to the position for the desired nailing mode before nailing.
► Fig.17: 1. Actuation mode selector Single sequential actuation mode: You can
drive one nail by one sequential operation. Select this mode when driving a
nail carefully and accurately. To choose this mode, set the actuation mode
selector to the position.
Contact actuation mode : You can drive nails repetitively by placing the
contact element with the trigger held. To choose this mode, set the actuation
mode selector to the position.
Checking proper action before the operation
Before the operation, always check the following points.
— Make sure that the tool does not operate only by connecting the air hose.
— Make sure that the tool does not operate only by pulling the trigger.
— Make sure that the tool does not operate only by placing the contact element
against the workpiece without pulling the trigger.
—In single sequential actuation mode, make sure that the tool does not operate
when pulling the trigger first and then placing the contact element against
the workpiece.
Single sequential actuation
CAUTION: Do not place the contact element against the workpiece with
excessive force. Also, pull the trigger fully and hold it on for 1-2 seconds
after nailing. Even in the “Single sequential actuation” mode, the half-
pulled trigger causes unexpected nailing, when the contact element re-contacts
the workpiece. Place the contact element against the workpiece and pull the
trigger fully. After nailing, release the contact element, and then release
the trigger.
► Fig.18
Contact actuation
Pull the trigger first and then place the contact element against the
workpiece.
► Fig.19
Anti-dry fire mechanism
This tool is equipped with an anti-dry fire mechanism. When there are a few nails remaining in the magazine, the contact arm will be locked in the undepressed position to prevent the tool from being activated. When it is activated, load more nails to resume operation.
Removing jammed nails
CAUTION: Always release the trigger and disconnect the hose before
removing jammed nails.
CAUTION: Do not use deformed nails or nail strips. Failure to do so causes
poor nail feeding. Follow the procedures in “Removing nails” to remove the
nails in the magazine. Open the latch and release the door, then remove the
jammed nail
► Fig.20: 1. Latch 2. Door
MAINTENANCE
CAUTION : Before attempting to perform inspection or maintenance, always
release the trigger and disconnect the air hose from the tool.
NOTICE: Never use gasoline, benzene, thinner, alcohol, or the like.
Discoloration, deformation, or cracks may result.
Nails
Handle nail strips and their box carefully. If the nail strips have been handled roughly, they may be out of shape, causing poor nail feed. Avoid storing nails in a very humid or hot place or place exposed to direct sunlight.
Maintenance of nailer
Always check the tool for its overall condition and loose screws before
operation. Tighten as required. With the tool disconnected, make a daily
inspection to assure free movement of the contact element and trigger. Do not
use the tool if the contact element or trigger sticks or binds. When the tool
is not to be used for an extended period of time, lubricate the tool using
pneumatic tool oil and store the tool in a safe place. Avoid exposure to
direct sunlight and/or humid or hot environments.
► Fig.21
Maintenance of compressor, air set, and air hose
After the operation, always drain the compressor tank and the air filter. If
moisture is allowed to enter the tool, it may result in poor performance and
possible tool failure.
► Fig.22: 1. Drain cock
► Fig.23: 1. The air filter checks regularly to see if there is sufficient
pneumatic tool oil in the oiler of the air set. Failure to maintain sufficient
lubrication will cause O-rings to wear quickly
. ► Fig.24: 1. Oiler 2. Pneumatic tool oil Keep the air hose away from heat
(over 60°C, over 140°F), and away from chemicals (thinner, strong acids, or
alkalis). Also, route the hose away from obstacles which it may become
dangerously caught on during operation. Hoses must also be directed away from
sharp edges and areas which may lead to damage or abrasion to the hose. To
maintain product SAFETY and RELIABILITY, repairs, and any other maintenance or
adjustment should be performed by Makita Authorized or Factory Service
Centers, always using Makita replacement parts.
OPTIONAL ACCESSORIES
CAUTION: These accessories or attachments are recommended for use with your Makita tool specified in this manual. The use of any other accessories or attachments might present a risk of injury to persons. Only use accessory or attachment for its stated purpose. If you need any assistance with more details regarding these accessories, ask your local Makita Service Center.
- Nails
- Air hose
- Safety goggles
NOTE: Some items in the list may be included in the tool package as
standard accessories. They may differ from country to country.
Annex A: EC Declaration of Conformity
We as the manufacturers: Makita Europe N.V., Business address: Jan-Baptist
Vinkstraat 2, 3070 Kortenberg, BELGIUM. Authorize Hiroshi Tsujimura for the
compilation of the technical file and declare under our sole responsibility
that the product(s); Designation: Pneumatic Finish Nailer. Designation of
Type(s): AF601. Fulfills all the relevant provisions of 2006/42/EC, and is
manufactured in accordance with the following Harmonised Standards: EN ISO
11148-13:2018. Place of declaration: Kortenberg, Belgium. Responsible
person: Hiroshi Tsujimura, Director – Makita Europe N.V. (date and signature
on the last page)
Annex A: Declaration of Conformity
We as the manufacturers: of Makita Europe N.V., Business address: Jan-Baptist
Vinkstraat 2, 3070 Kortenberg, BELGIUM. Authorize Hiroshi Tsujimura for the
compilation of the technical file and declare under our sole responsibility
that the product(s); Designation: Pneumatic Finish Nailer. Designation of
Type(s): AF601. Fulfills all the relevant provisions of S.I. 2008/1597 (as
amended), and is manufactured in accordance with the following Designated
Standards: EN ISO 11148-13:2018. Place of declaration: Kortenberg, Belgium.
Responsible person: Hiroshi Tsujimura, Director – Makita Europe N.V.(date and
signature on the last page) Importer: Makita (UK) Limited, Michigan rive,
Tongwell, Milton Keynes, Buckinghamshire, MK15 8D, UK
Makita Europe N.V.
Jan-Baptist Vinkstraat 2,
3070 Kortenberg, Belgium
Makita Corporation
3-11-8, Sumiyoshi-cho,
Anjo, Aichi 446-8502 Japan
AF601-DOC-32L-2007
www.makita.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>