AIGOSTAR B09MF9RK5T Portable Air Conditioners Instruction Manual

June 14, 2024
aigostar

AIGOSTAR B09MF9RK5T Portable Air Conditioners

AIGOSTAR B09MF9RK5T Portable Air Conditioners

IMPORTANT SAFETY INSTRUCTIONS

Thank you for choosing the luxurious and elegant mobile air conditioning. Please keep the manual for later review, and read the manual carefully before use.

Notes:

  • The air conditioning is only suitable for  indoor use, and is not suitable for other applications.
  • Follow local grid interconnection rules while installing the air conditioning and ensure that it is properly grounded. If you have any question on electrical installation, follow the instructions of the manufacturer, and if necessary, ask a professional electrician to install it.
  • Place the machine in a flat and dry place and keep a distance of above 50 cm between the machine and the surrounding objects or walls.
  • After the air conditioning is installed, ensure that the power plug is intact and firmly plugged into the power outlet, and place the power cord orderly to prevent someone from being tripped or pulling out the plug.
  • Do not put any object into the air inlet and outlet of the air conditioning. Keep the air inlet and outlet free from obstructions.
  • When drainage pipes are installed, ensure hat the drainage pipes are properly connected, and are not distorted or bended.
  • While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with hands gently to avoid damaging wind-guide strips.
  • When moving the machine, make sure that it is in an upright position.
  • The machine should stay away from gasoline, flammable gas, stoves and other heat sources.
  • Don’t disassemble, overhaul and modify the machine arbitrarily, otherwise it will cause a machine malfunction or even bring harm to persons and properties. To avoid danger, if a machine failure occurs, ask the manufacturer or professionals to repair it.
  • Do not install and use the air conditioning in the bathroom or other humid environments.
  • Do not pull the plug to turn off the machine.
  • Do not place cups or other objects on the body to prevent water or other liquids from spilling into the air conditioning.
  • Do not use insecticide sprays or other flammable substances near the air conditioning.
  • Do not wipe or wash the air conditioning with chemical solvents such as gasoline and alcohol. When you need to clean the air conditioning, you must disconnect the power supply, and clean it with a half-wet soft cloth. If the machine is really dirty, scrub with a mild detergent.
  • The appliance can be used by children aged  from 8 years and above and persons with reduced physical, sensory or mental capabilities if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and maintenance shall not be made by children without supervision.
  • Risk of fire or explosion. Flammable refrigerant used. To be repaired only by trained service personnel. Do not puncture refrigerant tubing.
  • Risk of fire or explosion. Dispose of properly in accordance with federal or local regulations. Flammable refrigerant used.

SPECIFICATION

Model No. JHS-A016G1 -06KR-D3 (330700A5M)
Power Supply 115 V ~ 60 Hz
Mean of Power Input 857W
Rated SACC 6500 Btu/h

FEATURES AND COMPONENTS

Features

  1. New look, compact structure, streamlined machine, aristocratic atmosphere.
  2. With cooling, heating (single cold without heating function), dehumidification and fan function, Continuously water drainage functions.
  3. Automatic swing leaf in the outlet has automatic air swing function, and the outlet can be covered when the machine is turned off to prevent dust from entering the body.
  4. LCD displays the control panel. The machine is beautiful and elegant. High-quality LCD remote control is equipped to facilitate operation.
  5. Handles on both sides adopt dividing point design, so that it is easier to carry it and the body design is more humane.
  6. The structure of wrapping the power cord on the back facilitates users to hang the power cord without hanging it down to the ground and staining and damaging the power cord.
  7. Outdoor interface is set high to facility assembly and keep the smooth flow of the heat pipe.
  8. Air filtration capability.
  9. Timing switch function.
  10. Protection function of automatically restarting the compressor after three minutes, with a variety of other protection functions.

Components

Components
Components

CONTROL SETTING

Control panel operation instructions

Operation interface:

  1. Power

  2. Up

  3. Down

  4. Sleep

  5. High Fan Speed

  6. Low Fan Speed

  7. Child lock

  8. Fan

  9. Dehumidifying

  10. Cooling

  11. Water Full

  12. Timer

  13. WIFI indicator

  14. Power: Press the key to turn on and turn off the unit.

  15. Up: Pressing this button to increase the temperature setting or set up the timer to the required timer setting. This function is not available under FAN mode and DEHUMIDIFYING mode.

  16. Down: Pressing this button to decrease the temperature setting or set down the timer to the required timer setting. This function is not available under FAN mode and DEHUMIDIFYING mode.

  17. Sleep Mode: In cooling mode, pressing the key button to turn on the sleep mode, then the unit will work on Energy-Saving and quiet mode. The display will go off 1 minute after you pressed the sleep button.

  18. High Fan Speed: In cooling and fan mode, pressing the key- to select high fan speed. This function is not available in SLEEP mode and DEHUMIDIFYING mode.

  19. Low Fan Speed: In cooling and fan mode, pressing the key to select low fan speed. This function is not available in SLEEP mode and DEHUMIDIFYING mode.

  20. Child lock: Press Up and Down button together for 3s to activate child lock function.

  21. Fan mode: Press the key to turn on FAN mode

  22. Dehumidifying mode: Press the key to turn on DEHUMIDIFYING mode

  23. Cooling mode: Press the key to turn on COOLING mode

  24. Water Full light: When the light is on, the unit stops and needs drainage.

  25. Timer: Press the key to set timer.

  26. WIFI indicator: Press the Power button for 5s to enter network configuration mode, the indicator flashes. When network configuration is complete, the indicator remains on.

Operation instructions of remote control

  1. The remote controller is as follows:
    ICONS| DESCRIPTIONS
    ---|---
    | Power: Press the key to turn on or turn off the machine.
    | Mode: press the key to switch between cooling, fan only, dehumidification function.
    | Up: press the key to increase temperature and timing set value.
    | Down: press the key to reduce temperature and timing set value.
    | Fan: Press the key to select high and low wind speed output circularly
    | Timer: press the key to set timing value.
    | Press the key to switch between Celsius and Fahrenheit.
    | Sleep Mode: Press the key to turn on the sleep mode.

Operation instructions of remote control

*NOTE: AM 1. SVDC battery (not included)

PROTECTION FUNCTION

Frost Protection Function:

In cooling, dehumidification or economic power saving mode, if the temperature of the exhaust pipe is too low, the machine will automatically enter protection status; if the temperature of the exhaust pipe rises to a certain temperature, it can automatically revert to normal operation.

Overflow Protection Function:

When water in the water pan exceeds the warning level, the machine will automatically sound an alarm, the water full indicator light will turn on. At this point, you need to move the drainage pipe connecting the machine or the water outlet to sewer or other drainage area to empty the water (details see Drainage Instructions part). After the water is emptied, the machine will automatically return to the original state.

Protection Function of the Compressor

To increase the service life of the compressor, it has a 3-minute delay booting protection function after the compressor is turned off.

INSTALLATION AND ADJUSTMENT

Installation:

Warning: Before using the mobile air conditioning, keep it upright for at least two hours. The air conditioning can be easily moved in the room. In the moving process, ensure that the air conditioning is in the upright position and the air conditioning should be placed on a flat surface. Do not install and use the air conditioning in the bathroom or other humid environments.

Install the heat pipe assembly (as shown in Fig.1)
  1. Take out the outer connector assembly and the exhaust pipe assembly, and remove the plastic bags;
  2. Insert the heat pipe assembly (the end of the exhaust joint) into the back panel vent slot (push to  the left) and complete the assembly (as shown in figure 1).
    Install the heat pipe assembly
Installation of window sealing plate components
  1. Half open the window, and mount the window sealing plate assembly to the window (as shown in Fig.2 and Fig.3). Components can be placed in horizontal and vertical direction.
    Installation of window sealing plate components

  2. Pull various components of the window sealing plate assembly open, adjust their opening distance to bring both ends of the assembly into contact with the window frame, and fix various components of the assembly.

Notes:

  1. The flat end of the exhaust pipe joints must be snapped into place.
  2. The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep the ventilation of the exhaust pipe not blocked.
Install the unit
  1. Move the machine with installed heat pipe and fittings before the window, and the distance between the body and walls or other objects shall be least 50 cm (as shown in Fig.4).
    Install the unit

  2. Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints into the hole of the window sealing plate assembly (as shown in Fig.5 and Fig.6)
    Install the unit

Notes:

  1. The flat end of the exhaust pipe joints must be snapped into place.
  2. The pipe cannot be distorted nor has substantial turning (greater than 45 °). Keep the ventilation of the exhaust pipe not blocked.

DRAINAGE INSTRUCTIONS

Manual drainage:

  1. When the machine stops after the water is full, turn off the machine power and unplug the power plug.
    Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom of the body.

  2. Place the water container below the side water outlet behind the body.

  3. Unscrew the rotary knob and unplug rubber stopper, the water will automatically flow into the water container.

Notes:

  1. Keep the rotary knob and rubber stopper properly.
  2. During drainage, the body can be tilted slightly backwards.
  3. If the water container cannot hold all the water, before the water container is full, stuff the water outlet with rubber stopper as soon as possible to prevent water from flowing to the floor or the carpet.
  4. When the water is discharged, stuff rubber stopper, and tighten the rotary knob.

Notes:

  1. Restart the machine after rubber stopper and rotary knob are installed, otherwise condensate water of the machine will flow to the floor or the carpet.
    DRAINAGE INSTRUCTIONS

  2. Continuous drainage (only applicable to cooling and dehumidification mode), as shown In figure:

  3. Unscrew the rotary knob, and unplug rubber stopper.

  4. Set the drainage pipe into the water outlet.

  5. Connect the drainage pipe to the bucket.

MAINTENANCE

Cleaning: before cleaning and maintenance, turn off the machine and unplug the plug.

  1. Clean the surface
    Clean with surface of machine with a wet soft cloth. Don’t use chemicals, such as benzene, alcohol, gasoline, etc; otherwise, the surface of the air conditioning will be damaged or even the whole machine will be damaged.

  2. Clean the filter screen
    If the filter screen is clogged with dust, and the effectiveness of the air conditioning is reduced, be sure to clean the filter screen once every two weeks.
    Clean the filter screen

  3. Clean the upper filter screen frame

  4. Unscrew one screw fixed by EVA filter net and back shell with screwdriver, and take out EVA filter net.

  5. Put the EVA filter screen into warm water with neutral detergent (about 40°C / 104°F) and dry it in the shade after rinsing clean.

TROUBLESHOOTING

Do not repair or disassemble the air conditioning by yourself. Unqualified repair will lead to failure of the warranty card, and may cause damage to users or their properties.

Problems Reasons Solutions
The air conditioning does not work. There is no electricity. Turn it on

after connecting it to a socket with electricity.
The overflow indicator displays “FL”| Discharge the water inside
The ambient temperature is too low or too high.| Recommend to use  the machine in at the temperature of 7-35°C (44-95 °F)
In cooling mode, the room temperature is lower than the set temperature; in heating mode, the room temperature is higher than the set temperature.| Change the set temperature.
In dehumidification mode, the ambient temperature is low.| The machine is placed in a room with an ambient temperature of greater than 17° (62 °F).
The cooling or heating effect is not good| There is direct sunlight.| Pull the Curtain.
Doors or windows are open; there are a lot of people; or in cooling mode, there are other sources of heat.| Close doors and windows, and add new air conditioning.
The filter screen is dirty| Clean or replace the filter screen
The air inlet or outlet is blocked.| Clear obstructions.
Big noise| The air conditioning is not placed on a flat sur ace.| Put the air conditioning on  a  flat and hard place (to reduce noise).
The compressor does not work| Overheat protection starts.| Wait for 3 minutes until the temperature is lowered, and then restart the machine.
The remote control does not work.| The distance between the machine and the remote control is too far.| Let the remote control  get close to the air conditioning, and make sure that the remote control directly faces to the direction of the remote control receiver.
The remote control is not aligned with the direction of the remote control receiver.
Batteries are dead| Replace batteries
Displays ‘E1 ‘.| The room temperature sensor is abnormal| Check the room temperature sensor and related circuitry
Displays ‘E2’| The pipe temperature sensor is abnormal.| Check the pipe temperature sensor and related circuitry.

If problems not listed in the table occur or recommended solutions do not work, please contact the professional service organization.

WARRANTY: 1 YEAR

Customer Support

AIGOSTAR INC
489 YORBITA RD, CITY OF INDUSTRY, CA 91744 (UNIT A)

http://www.aigostar.com
MADE IN CHINA

QR Code

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals