SHURE BETA 87C Vocal Microphone User Manual
- June 14, 2024
- Shure
Table of Contents
BETA87C
Vocal Microphone
Shure online user guide for BETA87C supercardioid electret condenser microphone.
General Description
The Shure BETA87C vocal microphone is precision-engineered to deliver an
extremely smooth, extended high-end frequency response in a cardioid condenser
design. The warm, natural sound creates an ideal environment for personal
monitoring with excellent rear rejection.
An advanced, cartridge shock mount system, hardened steel-mesh grille, and
superior build quality withstand the rigors of daily touring and sound
reinforcement.
Features
- Premier live performance microphone with Shure quality, ruggedness, and reliability
- Uniform cardioid pick-up pattern for maximum gain before feedback and excellent rejection of off-axis sound
- Smooth, wide frequency response with slight presence rise and controlled proximity effect tailored for vocals
- Advanced cartridge shock mount system absorbs mechanical shock and minimizes handling noise
- Very low susceptibility to RF and electromagnetic hum
- Dent-resistant steel mesh grille and enamel coated metal alloy construction resist wear and abuse
- Effective built-in pop filter reduces undesirable wind and breath noise
Applications
General Rules for Use
- Do not cover any part of the microphone grille with your hand, as this will adversely affect microphone performance.
- Aim the microphone toward the desired sound source (such as the talker, singer, or instrument) and away from unwanted sources.
- Place the microphone as close as practical to the desired sound source.
- Work close to the microphone for extra bass response.
- Use only one microphone to pick up a single sound source.
- For better gain before feedback, use fewer microphones.
- Keep the distance between microphones at least three times the distance from each microphone to its source (“three to one rule”).
- Place microphones as far as possible from reflective surfaces.
- Add a windscreen when using the microphone outdoors.
- Avoid excessive handling to minimize pickup of mechanical noise and vibration.
- Applications And Placement
- The following table lists the most common applications and placement techniques. Keep in mind that microphone technique is largely a matter of personal taste; there is no one “correct” microphone position.
Applications And Placement
The following table lists the most common applications and placement
techniques. Keep in mind that microphone technique is largely a matter of
personal taste; there is no one “correct” microphone position.
Application | Suggested Microphone Placement | Tone Quality |
---|---|---|
Vocals | Lips less than 15 cm (6 in.) away or touching the wind screen, on | |
axis to microphone. | Robust sound, emphasized bass, maximum isolation from |
other sources.
15 to 60 cm (6 in. to 2 ft.) away from mouth, just above nose height.| Natural
sound, reduced bass.
20 to 60 cm (8 in. to 2 ft.) away from mouth, slightly off to one side.|
Natural sound, reduced bass and minimal “s” sounds.
90 cm to 1.8 m (3 to 6 ft.) away.| Thinner, distant sound; noticeable levels
of ambient noise.
Avoiding Pickup of Unwanted Sound Sources
Place the microphone so that unwanted sound sources, such as monitors and loudspeakers, are directly behind it. To minimize feedback and ensure optimum rejection of unwanted sound, always test microphone placement before a performance. Recommended Loudspeaker Locations for Cardioid Microphones
Proximity Effect
Unidirectional (cardioid) microphones progressively boost bass frequencies by 6 to 10 dB below 100 Hz when the microphone is at a distance of about 6 mm (1/4 in.) from the sound source. This phenomenon, known as proximity effect, can be used to create a warmer, more powerful sound. To prevent explosive low frequency sound during close-up use, the bass response gradually rolls off. This provides greater control and helps the user take advantage of proximity effect.
Power Requirements
This microphone requires phantom power and performs best with a 48 Vdc supply
(IEC-61938). However, it will operate with slightly decreased headroom and
sensitivity with supplies as low as 11 Vdc.
Most modern mixers provide phantom power. You must use a balanced microphone
cable: XLR-to-XLR.
Specifications
Type
Electret Condenser
Frequency Response
50 to 16,000 Hz
Polar Pattern
Cardioid
Output Impedance
100 Ω
Sensitivity
at 1kHz,open circuit voltage
51 dBV/Pa(2 mV) [1] Maximum SPL
1 kHz at 1% THD,1 kΩ load
139 dB
Signal-to-Noise Ratio
70.5 dB
Dynamic Range
at 1kHz,1 kΩ load
117 dB
Clipping Level
1 kHz at 0.25% THD,1 kΩ load
6 dBV(0.5 V)
Self Noise
typical, equivalent SPL, A-weighted 22 dB
Hum Pickup
typical, at 60 Hz, equivalent SPL/mOe -5 dB
Polarity
Positive pressure on diaphragm produces positive voltage on pin 2 with respect
to pin 3
Weight
0.207 kg(0.475 lbs)
Connector
Three-pin professional audio (XLR), male, balanced
Housing
Aluminum construction with painted blue metallic finish, and hardened steel
grille with nickel satin chrome plating
Power Requirements
11 to 52 V DCphantom power(1.2 mA)
[1] 1 Pa=94 dB SPL
[2] S/N ratio is difference between 94 dB SPL and equivalent SPL of self
noise, A-weighted
Accessories
Furnished Accessories
Microphone Clip for SM58, SM57, SM87A, BETA87A, BETA87C, PGA57, PGA58, PGA48,
PGA81| A25D
---|---
Zippered Carrying Bag| 95A2314
Optional Accessories
Shock Stopper ® Isolation Mount | A55HM |
---|---|
Black Foam Windscreen for KSM8, SM85, SM86, SM87A, BETA87A, and BETA87C | A85WS |
25 foot (7.5m) Triple-Flex ® Microphone XLR Cable with chrome connectors | C25F |
Replacement Parts
Grille for Wired and Wireless BETA87, BETA87A and BETA87C | RK312 |
---|---|
Cartridge for BETA87C | RPM118 |
Plug (Connector) Assembly | 90J1984 |
Certifications
CE Notice
Hereby, Shure Incorporated declares that this product with CE Marking has been
determined to be in compliance with Euro pean Union requirements.
The full text of the EU declaration of conformity is available at the
following site: https://www.shure.com/enEU/support/declarations-of-
conformity.
UKCA Notice
Hereby, Shure Incorporated declares that this product with UKCA Marking has
been determined to be in compliance with UK CA requirements.
The full text of the UK declaration of conformity is available at the
following site: https://www.shure.com/enGB/support/declarations-of-
conformity.
The CE Declaration of Conformity can be obtained from:
www.shure.com/europe/compliance
Authorized European representative:
Shure Europe GmbH
Global Compliance
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: +49-7262-92 49 0
Email: info@shure.de
www.shure.com
References
- Shure: Microphones, Wireless microphones, in-ear monitoring, earphones, headphones
- Documentation Finder - Shure Europe
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>