ABESTORM Guardian SNS90 198 Pints Crawl Space Dehumidifiers
Product Information
The product is a Guardian Series Dehumidifier. It comes with an extensive warranty plan and to register for the warranty, the user needs to fill out and return the warranty form provided in the dehumidifier box. The dehumidifier has a model number (Guardian SNS90) and a serial number. The electrical supply requirement is a 3-prong, GFCI outlet. The dehumidifier utilizes its integral humidistat to monitor the conditioned space and operates by drawing air across an evaporator coil, condensing moisture out of the air, reheating it through a condenser coil, and distributing it back into the room. The installation requires sealing the area to be controlled with a vapour barrier and sealing all vents if installed in a crawlspace. The dehumidifier should be placed on a level surface and connected to a 15 amp grounded circuit.
Product Usage Instructions
- Registering Warranty: Fill out and return the warranty form provided in the dehumidifier box. Note down the dehumidifier serial number for registration.
- Safety Notes:
- Provide a minimum of 6 inches of clearance around the dehumidifier.
- Ensure both air inlet and air outlet are facing the open area of the space.
- Avoid inserting fingers or objects into the inlet or discharge.
- All work on the dehumidifier should be done with the unit off and unplugged.
- Do not use water to clean the exterior. Instead, unplug from power and use a damp cloth to wipe the exterior.
- Avoid standing on the machine or using it as a device to hang clothes.
- Identification: Note down the model number, serial number, and date of purchase for future reference. These details can be found on the label on the side of the unit.
- Electrical Supply:
- Ensure the outlet is a 3-Prong, GFCI type.
- Disconnect electrical power before servicing.
- Plug the unit only into a grounded electric circuit.
- Avoid using an extension cord or plug adapter.
- Principle of Operation: The dehumidifier uses an integral humidistat to monitor the relative humidity in the conditioned space. When the humidity goes above the set point, the dehumidifier activates. Moisture is condensed out of the air by drawing it across an evaporator coil, and then the air is reheated and distributed back into the room through a condenser coil.
- Installation:
- Seal the area to be controlled with a vapour barrier.
- If installing in a crawlspace, seal all vents.
- Avoid installing the dehumidifier in a corrosive environment.
- Usage Steps:
- Place the dehumidifier on a level surface.
- If the unit was not kept in an upright position during handling, wait for a minimum of 2 hours before turning it on.
- Set up the drain line by attaching it to the unit using the provided compression-type fitting on the discharge end. Slide the compression nut side of the hose over the insert on the compression fitting.
- Plug the unit into a 15 amp grounded circuit.
- Key Functions:
- Power Key: Press once to turn the dehumidifier on. A beep will be heard and the light will illuminate green. Press the power button again to turn it off.
Warranty Registration
- Congratulations on purchasing a new Guardian Dehumidifier. Your new dehumidifier comes with an extensive warranty plan. To register, simply fill out and return the warranty form provided in your dehumidifier box.
- Be sure to note your dehumidifier serial number as you will need it for registration.
Safety Notes
- The Guardian Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances). If non-grounded wiring is used, all liability reverts to the owner , and the warranty is voided.
- Guardian Dehumidifiers should only be maintained and repaired by a qualified technician.
- GuardianDehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level. Operating the unit in any other orientation could allow water to flood electrical components.
- Always unplug the dehumidifier before moving it to another location.
- lf there is a chance that water flooded the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting.
- To ensure proper operation, neither the inlet nor discharge should be positioned against a minimum of 6″ clearance.
- For better use of the dehumidifier, both air inlet and air outlet should be facing the open area of the space.
- Do not insert your fingers or any objects into the inlet or discharge.
- All work on the dehumidifier should be done with the unit“off” and unplugged.
- Do not use water to clean the exterior. To clean the unit, unplug from power, then use a damp cloth to wipe the exterior.
- Do not stand on the machine or use it as a device to hang clothes.
ldentification
- For future reference, write down the model, serial number, and date of purchase for your label on the side of your unit has the key characteristics of your specific unit.
Model Number: Guardian
- SNS90 Serial Number:……………………………………………..
- Date of Purchase:…………………………………………………….
Contact your installing contractor by E-mail: sales@abestorm.com.
Electrical Supply
- Power Supply: 115V,60 Hz AC, Single Phase Outlet Requirement: 3-Prong, GFCI circuit Protector: 15 Amp
WARNING: 240 Volts AC may cause serious injury from electric shock.
To reduce the risk of injury
- Disconnect electrical power before servicing.
- Only plug the unit into a grounded electric circuit.
- Do not use an extension cord.
- Do not use a plug adapter.
Principle of Operation
- The Guardian Series Dehumidifiers utilizes its integral humidistat to monitor the conditioned space.
- When the relative humidity goes above the selected setpoint, the dehumidifier will energize air is drawn across an evaporator coil, which is cooler than the dew point of the air.
- This means moisture will condense out of the air.
- The air is then reheated through the condenser coil and distributed back into the room.
lnstallation
The area to be controlled should be sealed with a vapour barrier. lf the unit
is installed in a crawlspace, all vents should be sealed.
WARNING: Do not install your dehumidifier in a corrosive environment. Some
liquid vapour barriers dry via “solvent evaporation”.Always make sure that the
barrier is completely dry and the area is thorough.
Step #1:Place dehumidifier on a level surface.
Do not place the unit directly on the vapour barrier. For example, use blocks
or pavers to create a level surface. you win is to plain fun a level sur co,
then wait a mornin’ of z hours tore puri going,
Step #2: Set Up Drain Line
The included drain line attaches to the unit via a compression-type fitting on
the discharge end of the unit. To attach the drain line, remove the
compression nut and slide it over the end of the hose to be attached to unit.
Slide the compression nut side of hose over the insert on the compression
fitting completely. Tighten the compression nut.
Step #3: Plug the unit into 15 amp grounded circuit.
Key Functions
-
Power Key
Use this button to turn the dehumidifier on and off. Press once to turn the machine on. You will hear one beep and the light will illuminate green. Press the power button a second time and will hear one beep as the machine shuts down. Note that there is a one-minute delay on shutdown. -
Arrow Buttons
Use the up and down arrow buttons to set the desired humidity setpoint on the display screen.
The set point can be any number between 36-90%. Creating a setpoint means that when the indoor humidity is higher than the set level, the unit will operate. NOTE: The humidity levels displayed are approximate only (+/-5%).
Continuous Mode
- To switch into a continuous mode, simply use the down arrow key to set the humidity below 36%. At this point the Cont. light should illuminate green on the display board to indicate you have successfully switched to continuous mode. The display screen will show “Co”.
- When set to continuous, the dehumidifier will run constantly, regardless of the humidity level until you turn the unit off ffor switch back to normal humidistat operation. If you would like to switch back to normal humidistat operation, simply move the setpoint above 36%.
Central Control
- This mode is not applicable on the Guardian SNS90.
- The central Control light should be o at all times when not connected to the AC.
Manual Drain Button
For extended storage or movement of the machine, press the “Drain” button to
remove water fro
Pump Trouble Warning
When the pump reservoir water level is too high, the high water sensor will
activate to prevent overflow. When this occurs, the dehumidifier will stop the
compressor automatically and the display will show “E4”.After a 1-minute
delay, the fan motor will turn o and the machine will not operate until the
problem is resolved. To reset the unit after an”E4″ error, check the pump to
verify it is functioning, then unplug the unit for two minutes.
Indicator Lights
- Humidity Display Screen
- The display screen has two functions:
- When the unit is powered on, it shows the humidity of the space.
- While setting the desired humidity level, the screen will show the set humidity. After a brief delay, the display will revert to the current humidity level.
- Power Indicator Light Power
- This light indicates that the unit is properly powered on and ready to operate. Always make sure the unit is “off” before performing any service.
- When the power light is blinking, it means that the unit has reached the humidity setpoint.
- Continuous Mode/AutoDefrost Light
- When this light illuminates green, it indicates that the dehumidifier is set to the continuous operation mode.
- When the light glows red, it means the unit is in auto-defrost mode and clearing the evaporator coil of any ice buildup.
- Compressor Light
- When the compressor light glows red, it indicates the compressor has been initiated but is currently warming up.
- Once the compressor light switches to green, it indicates the compressor is in working status.
Remote Control Instructions
-
Guardian Dehumidifiers can be controlled by using an optional remote accessory.
-
The Guardian Remote Control connects to your Guardian Series Dehumidifier via a 25′ CAT 5 cable. The Remote control contains an integrated sensor that gives you multiple options for remotely controlling your
unit, in addition to monitoring the conditions surrounding the dehumidifier. -
One application for the remote control is to install the dehumidifier in one room with the conditioned air ducted into a second room that contains the remote.
-
For example, the dehumidifier could be installed in a laundry room and ducted into a living room. The remote would then be mounted in the living room so the remote sensor can control the humidity and provide easy controls for the user.
-
Another useful application for the remote control is if the dehumidifier is in an area that’s difficult to access regularly. For instance, if your dehumidifier is installed in your crawl space, the remote could be mounted
in your living space or garage. This provides you with an easy way to monitor the dehumidifier.
-
On/O ff(Power)Button
Press the only fibutton and the machine will start running (one beep). Press the button again to turn the machine off. -
Up Button / Down Button
Use the Up and Down arrow buttons to adjust the humidity level. -
Mode M
Use the Mode button to switch between dehumidification and a ducted application.
• The symbol on the display board indicates the sensor on the remote control is being utilized.
• The symbol on the display board indicates the sensor on the dehumidifier is being utilized.
Temperature
Press the temperature button to display the current temperature on the screen.
Press the button again to turn of the display.
Continuous c
Press this button to switch the unit into continuous mode. cont. will appear
on the display to indicate continuous mode.
Drain Pump P
Use this button if the unit will not be in use for an extended time. Pressing
the drain pump button will remove water from the pump reservoir, so the unit
can be safely moved or stored.
NOTE: The symbols mentioned above will only appear when the dehumidifier
is powered on.
Operating Instructions
-
Start the machine
Press the power key to turn the machine on. -
Adjust Settings
Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%). -
Stop the machine
Press the power key again and the machine will stop. Note the fan will continue to operate for 1 minute after the unit has shut off. NOTE: Do not disconnect the power cord to force the machine to stop.Always use the power button. -
Water Drainage
The Guardian SNS90 has both automatic and manual draining. During normal operation, the Guardian SNS90 will automatically drain as required. lf you would like to store or move the machine, you may press the drain button to drain the water from the pump reservoir. The drain will operate for 28 seconds each time the button is pushed. lt may be necessary to push the drain button more than once to empty the reservoir.
Guardian SNS90 Diagram
Dehumidifier Storage
lf the unit will be stored for an extended time, complete the following steps:
- Turn o the unit and allow it to dry.
- Wrap and secure the power cord
- Cover filter mesh.
- Store in a clean, dry space.
Ducted Applications
- Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room.
- The supply grille is designed for 6″ flex ducting. Be sure to secure the ducting with a tie wrap. Also, keep in mind that the supply ducting can be screwed into an adapter if necessary.
Ducting Installation
- Maximum length for ducting= 6′
- Note: The supply duct adapter is standard on all units.
Removing Duct Adapter
If it is necessary to remove the adapter, place hand at bottom of the adapter
and use your hands to lift out and down. This will remove the cover hooks from
the machine.
Installing Duct Adapter
To install adapter, line it up with holes on the side of the unit and push it
up from the base of the adapter.
Flex Duct Installation
Rotate the flex duct counter- clockwise.
Flex Duct Removal
Rotate flex duct clockwise or remove wire tie.
Troubleshooting
Pump Alarm- Trouble Code E4
lf a pump alarm is shown on the display, complete the following steps:
- Reset the unit by disconnecting the power cord and then reconnecting it.
- Manually check to see if the pump is operational by pressing the drain button. Check if the pump ener-gizes and de-energizes properly.Additionally, check to see if any water purged from the system.
- Replace the hoses and/or pump, if maintenance alone isn’t sufficient.
Guardian SNS90 Spare Parts
Limited Warranty
IMPORTANT NOTICE: Keep the item’s packaging in case warranty service is required.
-
All warranty benefits apply to the original owner only. Warranty cannot be transferred or assigned.
-
1 YEAR(FROM DATE OF PURCHASE): Abestorm warrants the dehumidifier will operate free of defects
in workmanship and materials. At it’s discretion,Abestorm will repair or replace any malfunctioning components, free of charge (excluding transportation costs). -
3 YEARS (FROM DATE OF PURCHASE):Abestorm warrants the refrigeration circuit (compressor,condenser and evaporator)will operate free of defects in material or workmanship. At its discretion, Abestorm will replace defective parts, including factorylabor or refrigerant. This does not include transportation.
-
5 YEARS (FROM DATE OF PURCHASE): Abestorm warrants the compressor,condenser, and evaporator will operate free of any defects in material or workmanship.At its discretion, Abestorm willrepair or replace the defective parts. This does not includelabor, transportation, or refrigerant.
-
CUSTOMER RESPONSIBILITIES: n order to take advantage of the warranty service, the customer must do the following:
- Customer must provide normal care and maintenance (including, but not limited to cleaning filters, coils and pumps).
- Removal and re-installation of the unit is the sole responsibility of the owner.
- the lf customer cannot return the unit to the certfied repair center,all costs associated with freight shipment are borme by the customer. In addition, all duties related to freight shipments, including but not limited to palletizing, wrapping. labeling, andpickup are associated with the customer.
- lf shipped, the customer is responsible for all risk of loss or damage.
Abestorm Warranty Steps
- Once goods are received, customers must log in to www.Abestorm.comto fill out the Varranty Registration form and submit it toAbestorm company. We will receive your purchasing and installation information and save it. If no warranty registration is sent to us, the warranty period will begin the day the shipment left the warehouse. Please be sure torecord serial # and date of installation. You will need this information to receive the RA number.
- If warranty service is necessary, customers must contact Abestorm Tech Support by sales@abestorm.comorlocal technicalservice phone to receive a Return Authorization (RAnumber). Once an RA has been issued, customers should bring the unit to acertified repair center. Abestorm will arrange the shipping to bring the unit back to the Abestorm warehouse (at the expense ofthe customers) if customers are not available.
- After the unit has been received by Abestorm(whether at a repair center or the warehouse), Abestorm will ave an initial inspection.lfit is determined to be an invalid warranty claim (see exclusions below), customers have to pay for all associated repair costs andshipping costs for units repair.
- Customers can pick up the unit after repair at their own expense for shipping. Units will ave rigorous testing before sending back to customers.
- If the unit can no longer be fixed, and itis in the warranty period and determined to be a valid claim, we will ship the customer anew unit within the same year warranty from the date of replacement.
- After parts are repaired or replaced by Abestorm the original warranty period continues to apply untilitmeets its deadline.No extensions to the original warranty period.