ABESTORM Hurricane DV 110 Pints Commercial Dehumidifiers User Manual
- June 9, 2024
- ABESTORM
Table of Contents
- Hurricane DV 110 Pints Commercial Dehumidifiers
- OVERVIEW
- SPECIFICATIONS
- OPERATION NOTES GUIDELINES
- Hurricane DV Dehumidifier
- OPERATION
- OPERATION NOTES GUIDELINES
- TROUBLESHOOTING
- MAINTENANCE
- Limited Warranty
- Limited Warranty Exclusions
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
User’s Manual Hurricane DV
(110-120V/50HZz, Single-voltage)
Note: as we keep upgrading our product, we reserve the right to modify the product without notice in advance.
Hurricane DV 110 Pints Commercial Dehumidifiers
WARNING
Please read and understand these warnings and instructions before using the
machine.
Do not operate this device with the case opened or canceled.
WARNING
Do not adjust or correct the machine in any way. Only use and replace parts
authorized by Abestorm products. Modify or use approved parts.
It may cause danger or damage the machine, and the warranty will become
invalid. You should contact your dealer for assistance in this regard.
WARNING
| 1. Make sure to unplug the power plug before servicing.
---|---
| 2. Risk of electric shock
Before opening the machine cover, make sure to unplug the power cord.
Make sure the power cord is properly grounded.
Check that the power cord is not damaged. If the plug is damaged, do not use
the machine.
| 3. Be careful that moving parts can injure your hands. Make sure the power
plug has been unplugged before servicing.
| 4. The surface of the device may be hot. Allow the equipment to cool before
performing maintenance procedures.
OVERVIEW
Hurricane DV has an extremely high water-repellent capacity, which makes the
machine an authorized machine to meet recovery needs. The flexible
installation makes it ideal for almost all applications. It is the best choice
for all urgent post-water injection repair tasks (elimination of moisture and
early prevention of mold growth). Its wide range of applications include
flooding and restoration, carpet cleaning, laundry, merchants, garages, etc…
or anywhere you need to extract moisture at a professional level.
New generation surface scratch resistance polyethylene shell 25% than the
previous generation. The self-developed rotating shell design is easy to
maintain and beyond imagination. Telescopic handles and rubber tires are
stacked together for easy transportation. Under the condition of unchanged
performance, the volume of the whole machine is 40% smaller. Alarge LCD
simplifies user control. You can drain water anytime with a built-in
condensate pump, anywhere. Drain height up to 14.7 ft.
FEATURES
Easy Clean-Shell Can Be Opened to Access All Components
Easy to Store Wires And Hoses
Built-in Condensate Pump
Environmental R410A Refrigerant
Sturdy handle-Large Diameter
Wheels Microchannel Cold a Heat Exchanger
Rotational Molded Body
Superior Stacking
Rotary Compressor
Ducting Options
Water-Full Protection
Automatic Humidistat Control
Quick Connection to Cable/Hose
Memory Starting
MERV-8 Filter
Low Temperature
SPECIFICATIONS
Power(single-voltage):110-120V/60HZz, 4.2A
Filter: MERV – 8 Filter
Airflow: 210 CFM, 350 CMH
Sound Pressure Level: < 58 dBA
Refrigerant: R410A
Wheel: 2 Wheels
Draining: Condensate Pump
Functioning Temperature Range: 35.6~100.4 °F
Functioning Humidity Range: 25~80%
Water Removal (AHAM): 50 PPD@80 °F -60%
Weight(single-voltage):57.3 Ibs
Unit Dim(L x W x H):17.05″ X14.76″ X23.23″‘
OPERATION NOTES GUIDELINES
The unit should be operated stored and transported on stable surfaces. For efficiency purposes, the windows and the doors should be closed avoid placing the unit in a place where the air outlet and inlet are blocked.
Drain Hose Notes
It comes with a drain line connection that is easily plugged in the unit .
The drain line may be directed into the drain or the sink .
For proper drainage, uncoil the hose before you deploy it to use.
The end of the hose should never be placed at the height of 15 feet.
Always ensure that the drain hose is not blocked before you embark on using
it.
Transportation Notes
During transportation, you must secure the dehumidifier using elastic bands.
If the unit is transported vertically, let it stand in a normal position for
not less than 30 minutes before using it.
How it works
The dehumidifier uses an integral humidistat in monitoring the conditioned
space. As soon as the conditions get beyond the desired level, the air is
energized. The compressor will then push it across the evaporator coils. The
coil is cooler than the dew point. So the water vapor will be forced to
condensate into liquid. The cool air will then be reheated before it is
distributed into the room.
Hurricane DV Dehumidifier
OPERATION
| Press the POWER button to turn the dehumidifier ON and OFF.
---|---
| Press the PURGE button to purge the machine.
| Press the MENU button to advance to the next screen or to enter a value.
| Press the SET button to scroll through available values.
OPERATION NOTES GUIDELINES
1.The machine displays when it is not working.
(Power o ffstate but have electricity).
2. When the machine is in dehumidification mode, the display will show:
In: Temperature, Humidity, GPP of the current inlet. GPP= Grains per pound
(GR/LB).
Out: Temperature, Humidity, GPP of the current outlet. GPP= Grains per
pound (GR/LB).
Set: The humidity value currently Set (the machine will stand by after the
humidity reaches the Set value).
Job hours and Life hours display.
3.1 Display the working hours of this time. Press the MENU button to confirm selection and advance to the next screen.
3.2 The screen displays the Coil temp. Press the MENU button to confirm selection and advance to the next screen.
|
---|---
3.3 Press the “power button” to turn off the dehumidifier, the dehumidifier
will go through a shutdown cycle.
The shutdown cycle can be adjusted according to “Settings”, and the shutdown
cycle can be adjusted from 3 minutes to 20 minutes to better drain the water.
3.4 Press the Set button to toggle the temperature units between °F and °C. Press the MENU button to confirm selection and advance to the next screen.
3.5 Press the “Set button” to switch GPP units between gr/Ib.
or gr/kg. Press the “MENU button” to confirm the selection and advance to the
next screen. GPP= Grains per pound (GR/LB).
3.6 Press the “Set button” to adjust the set point RH% in 5% increments ranging from 25 to 80% RH. and then loop back to CO. Adjust to CO mode, dehumidifier always running. Press the “MENU button” to confirm selection and advance to the next screen.
|
---|---
3.7 The display prompts the user that the defrost cycle is in progress.
The defrosting status is displayed on the main interface as a flashing icon
until the defrosting ends and the defrosting lamp disappears. In the meantime,
please wait patiently for the machine to finish frosting.
3.8 The compressor is in a protective condition. During this period, please be patient and wait for the countdown to end. The dehumidifier will automatically turn on after the countdown.
|
---|---
3.9 When the purge button is pressed the display will tell the user on the dashboard that the pump is draining and display a 30-second countdown timer. Until the machine finishes draining, the display will also prompt the user on the dashboard that the machine is draining automatically, and display a 30-second countdown.
TROUBLESHOOTING
Symptom | Cause | Solution |
---|---|---|
A blank Display | Inappropriate Connection | Check and ensure that the two ends |
of the power code are properly plugged in
Power Outage| Try to have the power reset
The air is not flowing| A dirty Filter| The filter should be cleaned
A blocked air outlet and inlet| Remove the blockage
Error Code. El| Communication or humidity
sensor error| Ensure the sensor wire is properly connected at the two ends. If
no issue is visible, it shows that the sensor is faulty.
Error Code: E4| Problem with Pump| Verify that the pump is properly Installed
and functioning. If so, unplug the unit for two minutes, Then restart.
Error Code: LO| It comes forth when the temperature in the room falls below
33° F| The temperature in the room must be increased and should be above 33°F
If an error is displayed, you may need to check the sensor.
Error Code: HI| It occurs when the room
temperature is above 105°F| Reduce the temperature to below 105°F. But if the
error is still being displayed, check the sensor.
E5 Error Code| Leaking of the Refrigerant| Get help from installation
assistant.
MAINTENANCE
- Remove the two screws on the mold cover.
- Rotating shell.
- Tilt the machine at a certain angle to remove the casing from the machine.
- Clean the inside of the machine. Soap insolvents should not be used.
|
---|---
Cleaning the Machine Body
Use asoft, damp cloth to clean the exterior parts of the unit. Do not use
any soap or solvents.
Procedure for filter maintenance
The dust and obstacles on the filter should be removed regularly. You may need
to clean and replace the filter.
Step:
- Unplug the unit.
- Remove the filter by sliding it upward from the bottom by hand to remove it.
- Check for dirt and build-up.
- For MERV-8 or Pre-filter, wash it in warm water or vacuum it. Do not use soap or cleaners. Also, shake it gently and ensure the filters are dry before reinserting it.
Limited Warranty
This limited warranty starts from the date of purchase. Abestorm Solutions
Inc. warrants to the original purchaser that this Abestorm product is free
from manufacturing defects in material or workmanship for the limited warranty
period of:
Six (6) Month parts and labor. This includes the shipments charges for
replacement parts or unit.
One (1) year parts and labor. This does not include the shipment charge
to send the defective product back to be repaired or replaced.
Three (3) years parts and labor on Refrigeration System ONLY (Compressor,
Condenser, and evaporator). Transportation cost, not included.
Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser,
and evaporator).
Transportation cost, not included.
This limited warranty is valid only on products purchased from the
manufacturer or Abestorm authorized dealer and operated, installed, and
maintained according to the instructions included in this user guide or
furnished with the product. Abestorm Solutions Inc will not provide in- home
service during or after the warranty period. You may be responsible for the
shipping charge to bring the product to the manufacturer for service.
To receive warranty service, the purchaser must contact Abestorm at
888-276-9833 or
sales@abestorm.com. A proof of purchase or order
number is required to receive warranty service. During the applicable warranty
period, a product will be repaired or replaced at the sole option of Abestorm.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:
- Damage occurs in uses for which this product was not intended for.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.
** Abestorm Solutions INC.
Add: 8605 SANTA MONICA BLVD#79525
WEST HOLLYWOOD, California,90069 USA
E-mail:** sales@abestorm.com