The Basics
Disclaimer
The heart rate monitor is not a medical device and should not be used for any
medical purpose or under any medical conditions. It is intended only for
general wellness use.
Only use the heart rate monitor as described in this instruction manual. Any
other use is considered improper and may result in damage to property or even
personal injury.
The manufacturer or vendor cannot be held liable for damages incurred through
improper or incorrect use.
1.1 Safety
Warnings and Cautionary Advice
- Before using this device, please read this manual carefully and fully understand the corresponding warnings and risks.
- This device is not intended to replace medical diagnosis from a professional doctor.
- This device is not suitable for people wearing a pacemaker.
- Do not swim or submerge the device in water or other liquids.
- Do not forcefully collide or crush the device. If the casing is broken, cease using it.
- Do not twist the device.
- Keep this device away from children or pets.
- This device should not be used on people with sensitive skin or allergies.
- This device cannot be placed in the following environments: direct sunlight, high temperature, high humidity or sources of open flame.
- Users should inspect loosened electrodes, which may affect performance or cause other problems.
Introduction
VisualBeat is a wearable heart rate monitor for continuous measuring and
recording of heart rates while exercising.
The free ViHealth app allows you to review the data and monitor the ECG in
real-time.
2.1 Overview
-
Right side marking
The “R” mark should face the right side of the wearer when wearing the monitor. -
LED indicators
• OFF: The device is inactive, or the battery has run out.
• Steady Green: Start working
• Blinking Green: Same frequency as heartbeat.
• Slow Blinking Green: Standby/Charging completed
• Steady Orange: Charging.
• Blinking Orange: Same frequency as heartbeat and battery is low
• Slow Blinking Orange: Low Battery -
Charging contacts
Used to connect the charging cables. -
Electrode buckles
Used to connect chest straps, disposable ECG electrodes.
2.2 Unpacking
Main Unit;
Chest Strap;
Disposable ECG Electrodes;
Charging Cable;
User Manual;
2.3 Symbols
Symbol | Description |
---|---|
Manufacturer | |
Date of manufacture | |
SN | Serial number |
Indicates a medical device that is not to be disposed of as unsorted |
municipal waste.
| Follow Instructions for Use.
| Type CF Applied Part
| MRI unsafe. Presents hazards in all MR environments as device contains
strongly ferromagnetic materials.
IP22| Resistant to liquid ingress
| CE marking
| Authorized representative in the European community
| UKCA marking
| Authorized Representative in the United Kingdom
| This product complies with the rules and regulations of the Federal
Communication Commission.
| Non-ionizing radiation
| Our products and packaging can be recycled, don’t throw them away!
Find where to drop them off on the www.quefairedemesdechets.fr site (Only
applicable for French market).
Using the Monitor
3.1 Before Use
Activation
The monitor must be activated by charging it before the first use.
Note: The monitor will not work without being activated.
Charging
- Connect the main unit with the power/data cable, as shown in the picture.
- Connect the other end of the cable to the power source of 5V output/USB connector, like a laptop or power adapter.
Note:
- Clean and dry the charging contacts after use if you sweat while using the device. Wipe the contacts with a damp cloth, then wipe them dry.
- If it fails to charge, clean the charging contacts and wipe them dry.
Setting the Date and Time
Date and time on the monitor are automatically synchronized each time it is
connected to the ViHealth app.
For connecting the app, scan the QR code in 3.1 to check the quick guide for
ViHealth.
Note: To record the data with the proper date and time, we recommend
connecting the monitor to the ViHealth app before initial use.
Using the App
The ViHealth app allows you to transmit data after wearing the monitor, and
supports real-time monitoring of your heart rate and ECG.
Scan the QR code below to download the ViHealth App.
http://qr.hotlnk.cn/79816540314
For more software-related information, visit the website https://assets.lepudev.com/manual/VisualBeat.pdf or scan the QR code below for use instruction.
http://qr.hotlnk.cn/url/79844891829
Standby Mode
When the monitor is not working, it will automatically switch to standby mode.
Note: the monitor will switch to work mode when being worn.
3.2 Wearing the Monitor
The monitor supports two wearing methods, and you can choose which one suits
you.
3.2.1 Wearing with Chest Strap
-
Attach the monitor to the chest strap.
-
Dampen both electrodes on the back of the chest strap.
-
Position the monitor across the front of your chest, just below your pectoral (chest) muscles.
Note: Ensure the “R” is facing to the right. -
Adjust the length of the strap and tighten the strap to ensure the device remains in place while moving.
Note: Ensure the electrodes on the chest strap are placed snugly on the skin.
3.2.2 Wearing with Electrodes
-
Attach the monitor to the disposable ECG electrodes.
-
Remove the packaging from the disposable ECG electrodes.
-
Place the disposable ECG electrodes on the upper chest in the position shown below.
Note:
- Ensure the “R” mark is facing up.
- If you sweat a lot, to avoiding the electrodes falling off, we recommend you to use the strap measurement.
3.3 Recording the Heart Rate
Once you are wearing the monitor appropriately, the monitor switches to work
mode and automatically starts measuring and recording your heart rate.
The monitor only stores heart rate data in the built-in memory. The total
recording time allotted to all records is 30 hours. For a single record, the
recording time can be up to 24 hours.
If the total recording time exceeds 30 hours, the oldest data will be
overwritten by the most recent data.
After stopping measuring, you can review the resulting data on the app. Scan
the QR code in 3.1 to check the quick guide for ViHealth..
3.4 Linking to ANT+ Fitness Equipment
The monitor can be linked to fitness equipment via ANT+ technology, so you can
view your heart rate on the ANT+ compatible equipment console.
Search VisualBeat on your ANT+ compatible equipment. It will send heart rate
data to your equipment.
3.5 Factory Reset
You can restore factory settings on the monitor in the app.
Caution: all user-defined settings and measurement data will be deleted from
the monitor after factory settings have been restored.
Maintenance
By following the directions below, you can maximize the life span of your monitor.
- Never attempt to disassemble or repair the monitor.
- Protect the monitor from sharp objects, extreme heat or prolonged exposure to direct sunlight.
- Store the monitor in a clean, dry environment at room temperature.
- When putting on or taking off the monitor, do not excessively twist, bend or stretch it.
- To clean the monitor, wipe it with a soft, dry cloth, or with a cloth that has been moistened in a weak solution of water and a mild, neutral detergent.
- Remove the monitor from the strap and rinse the strap after every use.
- Hand wash the strap every week in cold water with a mild detergent.
- Do not put the strap in a dryer or a washing machine.
Note: Accumulation of sweat and salt on the strap decreases the device’s ability to provide accurate data.
Troubleshooting
Problem | Possible Cause | Solution |
---|
The monitor does not connect
with the app.| Your smart device is not compatible.| Check whether your smart
device is compatible.
The distance between the monitor and your smart
device is too great.| Keep your smart device near the monitor.
The monitor is connected to another device.| Check the other smart devices
around you and turn off their Bluetooth settings.
The device cannot perform normal acquisitions.| The battery is low.| Charge
the device
The equipment is damaged.| Contact your local retailer
Abnormal heart rate readings.| Poor contact
between the skin and the monitor electrodes.| Moisten the
electrode areas on the monitor.
The chest strap is loose.| Tighten the chest strap.
ECG waveform is disordered, and
significantly cluttered.| Measurement method is incorrect.| Refer to the
manual and ensure you’re wearing it properly.
Poor contact with ECG electrodes.| Please clean the ECG electrode according to
the method described in the manual.
The ECG| Hand or body may| Try to keep your
waveform
drifts.| be moving.| body perfectly still.
When using electrodes,
the signal is poor or the waveform is disordered| The electrodes is expired.|
Make sure the electrodes are within the warranty
period.
The skin may be dirty.| Clean the skin or hair with water and
dry it.
The electrode hasn’t stick on the skin closely.| Make sure the electrode are
well stick to the skin.
Specifications
Dimensions | 100×23×8.3 mm (main unit) |
---|---|
Weight | 18g (main unit) |
Wireless | Bluetooth 5.0, compatible with 4.0 |
Battery type | Rechargeable lithium-polymer battery |
Battery run time | 48 hours for typical use |
Charge time | 2-3 hours |
Heart rate range | 30 to 250 BPM |
In-app Storage | Unlimited |
In-app ECG Recordings | Up to 30 minutes for each session |
Heart rate recording in device | up to 10 sessions / 30 hours, up to 24 hours |
for each session.
FCC Statement
FCC ID: 2ADXK-3613
This device complies with section 15 of the FCC Rules.
Its operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operations.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to section 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur due to a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference with one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the retailer or an experienced radio/TV technician for assistance.
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
Contact us: service@getwellue.com
Website: www.getwellue.com
PN: 255-02654-00
Model: ER1
Version: E
Date: Nov.2022
Shenzhen Viatom Technology Co., Ltd.
4E, Building 3, Tingwei Industrial Park, No.6 Liufang Road, Block 67, Xin’an
Street, Baoan District, Shenzhen, 518101, Guangdong, China
Prolinx GmbH
Brehmstr 56, 40239, Duesseldorf, Germany
Tel:0049 211 3105 4698
E-mail:eu@eulinx.eu
Prolinx Global LTD
27 Old Gloucester Street, London, WC1N 3AX, UK
Tel: 0044 20 39661193
Email: eu@eulinx.eu
Contents of this manual are subject to change without prior notice.
©Copyright 2018 Shenzhen Viatom Technology Co., Ltd. All rights reserved.
References
- Wellue - Innovative Technology Powers Your Health
- Que Faire de mes Déchets ? Découvrez les solutions pour tous vos déchets et nos conseils pour en produire moins.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>