Wellue VisualBeat Heart Rate Monitor User Manual

June 14, 2024
Wellue

Wellue VisualBeat Heart Rate Monitor - cover

VisualBeat™
Heart Rate Monitor
User Manual

The Basics

Disclaimer
The heart rate monitor is not a medical device and should not be used for any medical purpose or under any medical conditions. It is intended only for general wellness use.
Only use the heart rate monitor as described in this instruction manual. Any other use is considered improper and may result in damage to property or even personal injury.
The manufacturer or vendor cannot be held liable for damages incurred through improper or incorrect use.

1.1 Safety
Warnings and Cautionary Advice

  • Before using this device, please read this manual carefully and fully understand the corresponding warnings and risks.
  • This device is not intended to replace medical diagnosis from a professional doctor.
  • This device is not suitable for people wearing a pacemaker.
  • Do not swim or submerge the device in water or other liquids.
  • Do not forcefully collide or crush the device. If the casing is broken, cease using it.
  • Do not twist the device.
  • Keep this device away from children or pets.
  • This device should not be used on people with sensitive skin or allergies.
  • This device cannot be placed in the following environments: direct sunlight, high temperature, high humidity or sources of open flame.
  • Users should inspect loosened electrodes, which may affect performance or cause other problems.

Introduction

VisualBeat is a wearable heart rate monitor for continuous measuring and recording of heart rates while exercising.
The free ViHealth app allows you to review the data and monitor the ECG in real-time.

2.1 Overview

Wellue VisualBeat Heart Rate Monitor - Introduction 1

  1. Right side marking
    The “R” mark should face the right side of the wearer when wearing the monitor.

  2. LED indicators
    • OFF: The device is inactive, or the battery has run out.
    • Steady Green: Start working
    • Blinking Green: Same frequency as heartbeat.
    • Slow Blinking Green: Standby/Charging completed
    • Steady Orange: Charging.
    • Blinking Orange: Same frequency as heartbeat and battery is low
    • Slow Blinking Orange: Low Battery

  3. Charging contacts
    Used to connect the charging cables.

  4. Electrode buckles
    Used to connect chest straps, disposable ECG electrodes.

2.2 Unpacking
Main Unit;
Chest Strap;
Disposable ECG Electrodes;
Charging Cable;
User Manual;

2.3 Symbols

Symbol Description
Manufacturer
Date of manufacture
SN Serial number
Indicates a medical device that is not to be disposed of as unsorted

municipal waste.
| Follow Instructions for Use.
| Type CF Applied Part
| MRI unsafe. Presents hazards in all MR environments as device contains strongly ferromagnetic materials.
IP22| Resistant to liquid ingress
| CE marking
| Authorized representative in the European community
| UKCA marking
| Authorized Representative in the United Kingdom
| This product complies with the rules and regulations of the Federal Communication Commission.
| Non-ionizing radiation
| Our products and packaging can be recycled, don’t throw them away!
Find where to drop them off on the www.quefairedemesdechets.fr site (Only applicable for French market).

Using the Monitor

3.1 Before Use
Activation
The monitor must be activated by charging it before the first use.
Note: The monitor will not work without being activated.

Charging

  1. Connect the main unit with the power/data cable, as shown in the picture.
  2. Connect the other end of the cable to the power source of 5V output/USB connector, like a laptop or power adapter.

Note:

  1. Clean and dry the charging contacts after use if you sweat while using the device. Wipe the contacts with a damp cloth, then wipe them dry.
  2. If it fails to charge, clean the charging contacts and wipe them dry.

Setting the Date and Time
Date and time on the monitor are automatically synchronized each time it is connected to the ViHealth app.
For connecting the app, scan the QR code in 3.1 to check the quick guide for ViHealth.
Note: To record the data with the proper date and time, we recommend connecting the monitor to the ViHealth app before initial use.

Using the App
The ViHealth app allows you to transmit data after wearing the monitor, and supports real-time monitoring of your heart rate and ECG.
Scan the QR code below to download the ViHealth App.

Wellue VisualBeat Heart Rate Monitor - qr

http://qr.hotlnk.cn/79816540314

For more software-related information, visit the website https://assets.lepudev.com/manual/VisualBeat.pdf or scan the QR code below for use instruction.

Wellue VisualBeat Heart Rate Monitor - qr 2

http://qr.hotlnk.cn/url/79844891829

Standby Mode
When the monitor is not working, it will automatically switch to standby mode.
Note: the monitor will switch to work mode when being worn.

3.2 Wearing the Monitor
The monitor supports two wearing methods, and you can choose which one suits you.

3.2.1 Wearing with Chest Strap

  1. Attach the monitor to the chest strap.
    Wellue VisualBeat Heart Rate Monitor - Using the Monitor
2

  2. Dampen both electrodes on the back of the chest strap.

  3. Position the monitor across the front of your chest, just below your pectoral (chest) muscles.
    Note: Ensure the “R” is facing to the right.

  4. Adjust the length of the strap and tighten the strap to ensure the device remains in place while moving.
    Note: Ensure the electrodes on the chest strap are placed snugly on the skin.

3.2.2 Wearing with Electrodes

  1. Attach the monitor to the disposable ECG electrodes.
    Wellue VisualBeat Heart Rate Monitor - Using the Monitor
5

  2. Remove the packaging from the disposable ECG electrodes.

  3. Place the disposable ECG electrodes on the upper chest in the position shown below.

Note:

  • Ensure the “R” mark is facing up.
  • If you sweat a lot, to avoiding the electrodes falling off, we recommend you to use the strap measurement.

3.3 Recording the Heart Rate
Once you are wearing the monitor appropriately, the monitor switches to work mode and automatically starts measuring and recording your heart rate.
The monitor only stores heart rate data in the built-in memory. The total recording time allotted to all records is 30 hours. For a single record, the recording time can be up to 24 hours.
If the total recording time exceeds 30 hours, the oldest data will be overwritten by the most recent data.
After stopping measuring, you can review the resulting data on the app. Scan the QR code in 3.1 to check the quick guide for ViHealth..

3.4 Linking to ANT+ Fitness Equipment

The monitor can be linked to fitness equipment via ANT+ technology, so you can view your heart rate on the ANT+ compatible equipment console.
Search VisualBeat on your ANT+ compatible equipment. It will send heart rate data to your equipment.

3.5 Factory Reset
You can restore factory settings on the monitor in the app.
Caution: all user-defined settings and measurement data will be deleted from the monitor after factory settings have been restored.

Maintenance

By following the directions below, you can maximize the life span of your monitor.

  • Never attempt to disassemble or repair the monitor.
  • Protect the monitor from sharp objects, extreme heat or prolonged exposure to direct sunlight.
  • Store the monitor in a clean, dry environment at room temperature.
  • When putting on or taking off the monitor, do not excessively twist, bend or stretch it.
  • To clean the monitor, wipe it with a soft, dry cloth, or with a cloth that has been moistened in a weak solution of water and a mild, neutral detergent.
  • Remove the monitor from the strap and rinse the strap after every use.
  • Hand wash the strap every week in cold water with a mild detergent.
  • Do not put the strap in a dryer or a washing machine.

Note: Accumulation of sweat and salt on the strap decreases the device’s ability to provide accurate data.

Troubleshooting

Problem Possible Cause Solution

The monitor does not connect
with the app.| Your smart device is not compatible.| Check whether your smart device is compatible.
The distance between the monitor and your smart
device is too great.| Keep your smart device near the monitor.
The monitor is connected to another device.| Check the other smart devices
around you and turn off their Bluetooth settings.
The device cannot perform normal acquisitions.| The battery is low.| Charge the device
The equipment is damaged.| Contact your local retailer
Abnormal heart rate readings.| Poor contact
between the skin and the monitor electrodes.| Moisten the
electrode areas on the monitor.
The chest strap is loose.| Tighten the chest strap.
ECG waveform is disordered, and
significantly cluttered.| Measurement method is incorrect.| Refer to the manual and ensure you’re wearing it properly.
Poor contact with ECG electrodes.| Please clean the ECG electrode according to the method described in the manual.
The ECG| Hand or body may| Try to keep your
waveform
drifts.| be moving.| body perfectly still.
When using electrodes,
the signal is poor or the waveform is disordered| The electrodes is expired.| Make sure the electrodes are within the warranty
period.
The skin may be dirty.| Clean the skin or hair with water and
dry it.
The electrode hasn’t stick on the skin closely.| Make sure the electrode are well stick to the skin.

Specifications

Dimensions 100×23×8.3 mm (main unit)
Weight 18g (main unit)
Wireless Bluetooth 5.0, compatible with 4.0
Battery type Rechargeable lithium-polymer battery
Battery run time 48 hours for typical use
Charge time 2-3 hours
Heart rate range 30 to 250 BPM
In-app Storage Unlimited
In-app ECG Recordings Up to 30 minutes for each session
Heart rate recording in device up to 10 sessions / 30 hours, up to 24 hours

for each session.

FCC Statement
FCC ID: 2ADXK-3613
This device complies with section 15 of the FCC Rules.
Its operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to section 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur due to a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference with one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the retailer or an experienced radio/TV technician for assistance.

The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.

Contact us: service@getwellue.com
Website: www.getwellue.com
PN: 255-02654-00
Model: ER1
Version: E
Date: Nov.2022

Shenzhen Viatom Technology Co., Ltd.
4E, Building 3, Tingwei Industrial Park, No.6 Liufang Road, Block 67, Xin’an Street, Baoan District, Shenzhen, 518101, Guangdong, China

Prolinx GmbH
Brehmstr 56, 40239, Duesseldorf, Germany
Tel:0049 211 3105 4698
E-mail:eu@eulinx.eu

Prolinx Global LTD
27 Old Gloucester Street, London, WC1N 3AX, UK
Tel: 0044 20 39661193
Email: eu@eulinx.eu

Contents of this manual are subject to change without prior notice.
©Copyright 2018 Shenzhen Viatom Technology Co., Ltd. All rights reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals