Wellue Portable Mesh Inhaler User Manual

June 12, 2024
Wellue

Wellue Portable Mesh Inhaler

Wellue-Portable-Mesh-Inhaler-
product

Product Information

The product is a portable mesh inhaler with several features:

  • Two inhalation modes: manual mode and ultrasonic mode
  • Adjustable intensity for inhalation
  • Removable medicine container
  • Automatic cleaning technology
  • Non-stop operation for up to 60 minutes
  • Low weight and noise

Product Usage Instructions

  1. Consult your doctor before using the device and consult them about using a specific inhalation solution.
  2. If the device is used by children, they should be supervised.
  3. Do not use the device if it has been damaged or has come into contact with water.
  4. Keep the equipment clean and do not pour tap water into the device.
  5. The equipment is delivered disassembled. Follow the provided pictures to assemble it.
  6. Add the inhalation solution as directed by your doctor before switching on the device. Be careful not to spill the solution when opening the lid.
  7. The device is charged using a USB cable and charger (not included). Use a charger with specifications of DC 5.0V 1.0A.
  8. A flashing flash diode indicates low battery status. The charging time is approximately two hours, and the operating time on the battery is approximately 60 minutes.
  9. To switch on the device, press the power button for three seconds. The green light will flash to indicate the inhalation modes are activated.
  10. In manual mode, the green light shines continuously. Use the + and – buttons to adjust the intensity of the inhalation. In ultrasonic mode, the green light amplifies and dims its intensity.
  11. You can inhale in three ways: straight, through the mask, or through the mouthpiece.
  12. The device is set to allow a maximum inhalation time of 10 minutes before automatically switching off. If you need to continue inhaling, turn the device back on. To perform a manual shutdown, press the power button briefly.
  13. After inhalation, discard the remaining inhaled solution, disassemble the device components, and clean them.
  14. After each use, clean and disinfect the apparatus and its components. Do not clean while the device is on or charging. Only reassemble the device when each component is completely dry. Avoid submerging or soaking the main unit in water. Use a damp cloth or similar for cleaning.
  15. Dispose of the product at an electrical waste collection point as it contains batteries and/or recyclable electrical waste.

Product Description
Portable mesh inhaler with two inhalation modes, adjustable intensity, removable medicine container, automatic cleaning technology, non-stop operation for up to 60 minutes and low weight and noise..

Safety instructions

  • Consult your doctor about using the device.
  • Consult your doctor about using a particular inhalation solution.
  • If the devices are used by children, they should be supervised.
  • Do not use the device if it has been damaged or has come into contact with water.
  • Keep equipment clean.
  • Do not pour tap water into the device.

Product Description

  • 1 – spray unit
  • 2 – Cap
  • 3 – Medicine container
  • 4 – On
  • 5 – main part of the device
  • 6 – USB charging
  • 7 – Mask
  • 8 – mouthpiece
  • 10 – Adjustment of intensityWellue-Portable-Mesh-Inhaler-fig- \(1\)

Mounting

The equipment is delivered disassembled. Follow the pictures when assembling.

Wellue-Portable-Mesh-Inhaler-fig- \(2\)

Before switching on the device, add the inhalation solution to it as directed by your doctor. When opening the lid afterwards, be careful not to spill the solution.

Wellue-Portable-Mesh-Inhaler-fig- \(3\)

Charging

  • The device is charged using a USB cable and charger (not included). Charger specifications should be DC 5.0V 1.0A.
  • Low battery status is indicated by a flashing flash diode (approx. it stops after 5 minutes of flashing).
  • The charging time is approximately two hours. The operating time on the battery is approximately 60 minutes.
  • While charging, the flash diode flashes when the device is fully charged, the flashing stops.

Instructions for use

  • Green light on – manual mode
  • Green light changes intensity – ultrasonic mode
  • Green light flashes three times – mode switching indication (must hold on the button for 3 seconds)
  • Blue light flashes five times – low battery capacity
  • The orange light flashes ten times – the inhalation solution is missing and the device is switched off
  • Blue light blinks – charging
  • Blue light on – fully charged
  • Green light flashes 10 times – end of the 10-minute mode

The device offers two inhalation modes, press the power button for three seconds to switch them on. Switching is indicated by a flashing green light. In manual mode, the green light shines continuously, using the + and – buttons to change the intensity of the inhalation. In ultrasonic mode, the green light amplifies and dims its intensity.

You can inhale in three ways as shown in the picture. Straight, through the mask, and through the mouthpiece.

Wellue-Portable-Mesh-Inhaler-fig- \(4\)

  • The device is set to allow a maximum inhalation time of 10 minutes, then switched off. If you need to continue inhaling, turn the device back on.
  • To do manual shutdown, press the power button briefly.
  • Discard the remainder of the inhaled solution after inhalation, disassemble the pieces of the device (see picture) and clean them.Wellue-Portable-Mesh-Inhaler-fig- \(5\)

Cleaning

  • After each use, the apparatus and its component parts must be cleaned and disinfected. Do not clean while the device is on or charging. Only reassemble the device if each component is completely dry.
  • Never submerge or soak the main unit in water. Use a damp cloth, etc., for cleaning.

Disposal

The product contains batteries and/or recyclable electrical waste. In order to protect the environment, do not dispose of the product with conventional waste, but hand it over for recycling at an electrical waste collection point.

Declaration of Conformity

By doing so, the importer, Satomar, s.r.o., declares that the equipment complies with all the essential requirements of the EU directives that apply to it.

  • The complete text of the Statement of Conformity can be downloaded at http://www.satomar.cz.
  • Copyright © 2020 Satomar, s. r. o. All rights reserved.
  • Appearances and specifications can be changed without notice. Printing errors reserved. The most up-to-date version of the manual can be found at www.mobilnipodpora.cz.

References

Read User Manual Online (PDF format)