HALCYON R774 W34V3 LED Recessed Luminaire Light Owner’s Manual

June 10, 2024
HALCYON

HALCYON R774 W34V3 LED Recessed Luminaire Light Owner’s Manual

CLASSIFICATION SHEET / IC-F

In the vicinity of the recessed luminaire, use an insulation product that:
(a) Maintains its dimensions and structural integrity when exposed to a temperature of 90°C; and
(b) Withstands a 30-second needle flame test carried out in accordance with AS/NZS 60695.11.5 with the flame applied to all surfaces of the sample.

Rear of fitting may abut structural members and building elements.

Do not install through or directly into joist, beam, rafter or ceiling batten.

Recessed luminaires and their associated equipment may pose a risk of fire or damage to property if not installed and maintained correctly. Halcyon recommends a clearance of 25mm to
building elements for optimum lifespan.

Halcyon IC rated luminaires are completely safe to install in sarked timber ceiling linings.
Halcyon accepts no responsibility if the timber used is not treated correctly and dries out, crack or warps over time due to the constant low heat from the aforementioned “IC Rated” LED recessed lighting.

This data sheet contains information necessary to ensure compliance with the New Zealand
Electrical Code of Practice for Installation and Maintenance of Recessed Luminaires and
Associated Equipment AS/NZS 60598.2.2:2001

INSTALLATION R774 W34V3 / R774 B34V3

Installation Directions

  1. Switch off mains power supply
  2. Connect Dimmable Driver to mains voltage cable (L, N) Do not connectdownlight to driver if driver is live. Inrush current from live driver will cause instant downlight failure. Do not switch secondary side .
  3. Adjust colour temperature and/or output wattage if required.
  4. Carefully install downlight into pre-cut 0145mm hole.
  5. Turn on mains power and switch on lighting circuit.

Approved Clearances

Note: 0mm required but 25mm always recommended for optimum product lifespan through effective heat dissipation.

Example 1:

0mm Approved Height Clearance. Building element abutting rear, insulation abutting sides of fitting.

Example 2:

0mm Approved Side Clearance. Building element abutting side of fitting, insulation abutting and covering fitting.

Cutting of holes prior to receiving goods is entirely at the risk of the

installer.

10 Basalt Place, East Tamaki, Auckland, PO Box 58-501, Botany, Manukau 2163, Auckland, New Zealand
Ph (0064 9) 273-9177 Fax (0064 9) 273 9155 Email: sales@halcyon.co.nz Web: www.halcyonlights.co.nz

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HALCYON User Manuals

Related Manuals