Zigbee ROB_200-015-0 RGBW LED Driver Instruction Manual
- June 14, 2024
- zigbee
Table of Contents
- Zigbee ROB_200-015-0 RGBW LED Driver
- Product Usage Instructions
- Function introduction
- Product Data
- Operation
- TouchLink to a Zigbee Remote
- Factory Reset Manually
- Factory Reset through a Zigbee Remote (Touch Reset)
- ZigBee Clusters the device supports are as follows
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Zigbee ROB_200-015-0 RGBW LED Driver
Zigbee Smart Plug
- Important: Read All Instructions Prior to Installation
Function Introduction
- 70110005
- Program button : Short press to switch on/off load
Product Data
- Zigbee profile : 0x0104 (ZHA)
- Device ID : 0x000A (Plug-in Unit)
- Radio Frequency : 2.4GHz
- Input Voltage: AC200-240V, 50/60Hz
- Max. Load : Load power > 2200W
- Over Current Protection : Definition (16.1A Over Current)
- Operating Temperature: N/A
- Relative Humidity : N/A
- Dimensions : N/A
- LED Indicator
- Flashes red slowly
- Stays solid orange
- Stays solid yellow
- Stays solid green
- Stays solid cyan
- Stays solid blue
- Flashes purple slowly
- Stays solid white at a low brightness
Product Usage Instructions
To switch on/off the load
- Locate the program button on the Zigbee Smart Plug.
- Short press the program button to switch on/off the load connected to the plug.
Important: Read All Instructions Prior to Installation
Function introduction
Product Data
Zigbee profile | 0x0104(ZHA) |
---|---|
Device ID | 0x000A(Plug-in Unit) |
Radio Frequency | 2.4GHz |
Input Voltage | AC200-240V, 50/60Hz |
Max. Load | 16A |
Over Current Protection | 16.1A |
Operating temperature | 0 to 40°C |
Relative humidity | 8% to 80% |
Dimensions | 114.8×54.8×74.7(mm) |
LED Indicator State | Definition (16.1A Over Current) |
--- | --- |
Flashes red slowly | Over current |
Stays solid orange | Load power > 2200W |
Stays solid yellow | Load power 2001-2200W |
Stays solid green | Load power 1501-2000W |
Stays solid cyan | Load power 1001-1500W |
Stays solid blue | Load power <= 1000W |
Flashes purple slowly | Firmware updating via OTA |
Stays solid white at a low brightness | Load switched off |
- ZigBee smart plug based on latest ZigBee 3.0 protocol
- Enables to control ON/OFF of the load, supports max. 16 scenes
- Supports find and bind mode to bind a ZigBee remote
- Supports zigbee green power and can bind max. 20 zigbee green power switches
- Supports temperature measurement
- Supports over current protection and power metering, enables to report power consumption to gateway
- ZigBee end device that supports Touchlink commissioning
- Waterproof grade: IP20
Safety & Warnings
- DO NOT install with power applied to device.
- DO NOT expose the device to moisture.
Operation
- Plug the smart plug into AC power source.
- This ZigBee device is a wireless receiver that communicates with a variety of ZigBee compatible systems. This receiver receives and is controlled by wireless radio signals from the compatible ZigBee system.
- Zigbee Network Pairing through Coordinator or Hub (Added to a Zigbee Network)
- Step 1 : Remove the device from previous zigbee network if it has already been added to, otherwise pairing will fail. Please refer to the part “Factory Reset Manually”.
- Step 2 : From your ZigBee Controller or hub interface, choose to add lighting device and enter Pairing mode as instructed by the controller.
- Step 3 : Short press “Program” button 5 times continuously to set the device to network pairing mode, LED indicator will flash white fast.
TouchLink to a Zigbee Remote
- Step 1 : Short press “Prog” button 4 times (Or re-power on the device 4 times) to start Touchlink commissioning, 180S timeout. Once timeout, repeat the operation.
Note
- Directly TouchLink (both not added to a ZigBee network), each device can link with 1 remote.
- TouchLink after both added to a ZigBee network, each device can link with max. 30 remotes.
- To control by both gateway and remote, add remote and device to network first then TouchLink.
- After TouchLink, the device can be controlled by the linked remotes.
- Removed from a Zigbee Network through Coordinator or Hub Interface
Factory Reset Manually
- Step 1 : Short press the “program” button 5 times continuously, the plug will enter into network pairing mode.
Factory Reset through a Zigbee Remote (Touch Reset)
Note: Make sure the device already added to a network, the remote added to the same one or not added to any network.
- Step 1 : Re-power on the device to start TouchLink Commissioning, 180 seconds timeout, repeat the operation.
Find and Bind Mode
Note: Make sure both the device and remote are added to the same gateway
that supports find and bind.
- Step 1: Short press “Prog.” button 3 times to start Find and Bind mode (LED indicator flashes white slowly) to find and bind target node, 180 seconds timeout, repeat the operation.
- Learning to a Zigbee Green Power Switch
- Step 1 : Short press “Program” button 4 times to start Learning to GP switch mode (LED indicator flashes twice), 180 seconds timeout, repeat the operation.
- Delete Learning to a Zigbee Green Power Switch
- Step 1 : Short press “Program” button 3 times to start delete Learning to GP switch mode (LED indicator flashes slowly), 180 seconds timeout, repeat the operation.
- Setup a Zigbee Network & Add Other Devices to the Network (No Coordinator Required)
- Step 1 : Short press “Program” button 4 times to enable the device to setup a zigbee network (LED indicator flashes white twice) to discover and add other devices, 180 seconds timeout, repeat the operation.
- Step 2 : Set another device or remote or touch panel into network pairing mode and pair to the network, refer to their manuals.
- Step 3 : Pair more devices and remotes to the network as you would like, refer to their manuals.
- Step 4 : Bind the added devices and remotes through Touchlink so that the devices can be controlled by the remotes, refer to their manuals.
Note
- Each added device can link and be controlled by max. 30 added remotes.
- Each added remote can link and control max. 30 added devices.
ZigBee Clusters the device supports are as follows
Input Clusters
- 0x0000 : Basic
- 0x0003 : Identify
- 0x0004 : Groups
- 0x0005 : Scenes
- 0x0006 : On/off
- 0x0402 : temperature measurement
- 0x0702 : Simple Metering
- 0x0b04 : Electrical Measurement
- 0x0b05 : Diagnostics
- 0x1000 : ZLL Commissioning
Output Clusters
- 0x0003 : Identify
- 0x0019 : OTA
OTA
The device supports firmware updating through OTA, and will acquire new
firmware from zigbee controller or hub every 10 minutes automatically.
Read User Manual Online (PDF format)
Loading......