THORN Freja IP44 LED Batten Instruction Manual
- June 15, 2024
- THORN
Table of Contents
THORN Freja IP44 LED Batten Instruction Manual
Installation Instructions
- Installation and commissioning may only be carried out by authorized specialists and wired in accordance with the latest IEE electrical regulations or the national standards.
- Mains power must be switched off before carrying out installation.
- The manufacturer, shall not be liable for any damage resulting from inappropriate modifications to the luminaire or faulty installation.
- Light source replaceable.
- Caution, risk of electric shock.
The control gear provides basic insulation between the DoubleSpace supply and the control circuit.
SAP Code| Product Description| Input| Wattage|
Operating temperature| L| W| H| LF| WF|
Efficiency class
---|---|---|---|---|---|---|---|---|---|---
966360| FREJA VARIOFLEX 1200 4200 830/35/40| 220-240V 50/60Hz| 15/22/29W|
-20~40℃| 1255| 170| 66| 1000| 134| C
96636006| FREJA VARIOFLEX 1500 7000 830/35/40| 220-240V 50/60Hz| 24/35/47W|
-20~40℃| 1255| 170| 66| 1200| 134| C
DIMENSION
INSTRUCTION
1 | LED Batten | X1 |
---|---|---|
2 | Plastic expansion | X4 |
3 | Screw | X4 |
4 | Flat Gasket | X4 |
5 | Rubber Gasket | X4 |
6 | Instructions | X1 |
7 | Accessory bag | X1 |
TOOLS REQURID
Thorn Lighting Limited, Durham gate, Spennymoor, Co Durham, DL16 6HL, UK Zumtobel Lighting GmbH, Schweizerstrasse 30, 6850 Durbin, Austria URL:www .thorn-eco.com