INDOL EH100UV4 Heat Pump Heater User Manual

June 15, 2024
INDOL

INDOL EH100UV4 Heat Pump Heater

INDOL-EH100UV4-Heat-Pump-Heater-PRODUCT

Product Information

The INDOL-UV4 system is a wall-mounted air conditioning unit designed to capture thermal energy from the air and provide cooling. It comprises several components including the INDOL-UV4 unit, silent-blocks, anchor screws, safety valve, and a user manual. The system operates based on the following principles:

  1. The evaporator captures thermal energy from the air using refrigerant.
  2. The compressor increases the temperature and pressure of the refrigerant.
  3. The refrigerant circulates to the expansion valve, where its pressure decreases before entering the evaporator.

The unit has two air connections located at the top cover, allowing for different installation possibilities. It is recommended to install a double duct system to recover cold air and refresh a room. The electrical connection of the equipment is 230 V/1/50 Hz.

Product Usage Instructions

  1. To install the INDOL-UV4 system, follow these steps:
    • Mount the unit on the wall using the supplied brackets.
    • Secure the unit using coach screws M10x80, lock washer M10, and screw anchors 12×60.
    • Adjust and regulate the supplied silent blocks on each side of the unit.
  2. For air connection:
    • Use a double duct system to recover cold air and refresh a room.
    • Install one duct to the room and another to outdoors.
    • Use a gate to control the airflow, directing it outdoors when cooling isn’t needed.
    • Ensure the electrical connection of the equipment is 230 V/1/50 Hz.

INTRODUCTION

  • This product has been manufactured according to the European Quality Standards, incorporates prime grade materials and its correct working has been tested before it leaves our facilities.
  • Through this Installation and User Manual, you will be guided toward the correct and safe installation of the product.
  • It is necessary to carefully read this manual before making any handling to avoid problems arising from the misuse of the product.
  • The company reserves the right to modify the information included in this document at any time without prior notice.

GENERAL INDICATIONS

Safety notes
The incorrect or inappropriate use of this product could lead to hazardous situations, causing damage or injuries to the user, third parties, or even to the product itself or material goods.

  • The installer has the responsibility to install the minimum safety devices (hydraulic and electrical) set out in this Manual. In case of failure, the lack of any device may cause burns or other injuries.
  • The installer has the responsibility to inform the user about the function and placement of the safety devices installed into the device and the installation.
  • The water outlet temperature could reach 70 degrees. Do not touch the pipes while the system is working to avoid any risk of burns.

Package contents

The INDOL-UV4 system comprises the following components:

  • INDOL-UV4 (according to model)
  • Silent-Blocks
  • Anchor screws
  • Safety valve
  • User Manual

Indications about transport and unpacking of the unit

  • The unit is supplied and packed into a wooden pallet and properly secured to prevent damage during transport.
  • The materials used for packing are recyclables, so dispose of it in an appropriate container.
  • Use a forklift or hand pallet truck to transport the unit to the installation site, always introducing the forks into the bottom of the pallet being careful not to damage the unit.
  • In case you identify any damage at the time of the reception of the unit, it is mandatory to register it in the reception note of the transport company, and then, submit the complaint.
  • For this reason, it is recommended to make a thorough visual inspection of the goods before signing the reception note.

TECHNICAL INFORMATION

Operating PrincipleINDOL-EH100UV4-Heat-Pump-Heater-FIG-1
\(1\)

  1. The evaporator captures the thermal energy from the air through the refrigerant.
  2. The compressor compresses the refrigerant, increasing its temperature and pressure.
  3. The collected energy is transferred to water in the condenser. The accumulated water in- increases its temperature reaching up to 55 °C.
  4. The refrigerant circulates to the expansion valve, where its pressure decreases to achieve the optimum conditions before entry into the evaporator.

Dimension drawings

INDOL-EH100UV4-Heat-Pump-Heater-FIG-1
\(2\)INDOL-EH100UV4-Heat-Pump-Heater-FIG-1
\(28\)

Technical data

INDOL-EH100UV4-Heat-Pump-Heater-FIG-1
\(29\)

INSTALLATION STEPS

Before starting the installation, check the availability of all the necessary components and tools:

  • Drill
  • Screwdriver
  • Hydraulic installation components
  • Electric installation components

Once it has been checked that it is available all the necessary components and tools, the installer should follow the next steps:

  1. Placing the unit
  2. Hydraulic installation
  3. Air connections
  4. Electric installation
  5. Commissioning

PLACING INDOL-UV4 UNIT

The place where the system will be installed should allow easy access to maintenance work or inspection. The air outlet of the unit is around 5-10 degrees below the inlet temperature, so in case the exhaust air is not be ducted, the room temperature will be considerably reduced. Besides these factors, it is important to consider the following indications regards the installation site:

  • The system has been designed and manufactured for its indoor utilization. Install the system in a dry, frost-free room at a minimum temperature of 5 °C.
  • The installer must install the supplied silent blocks to avoid the transmission of vibration.
  • The wall where the system will be installed has to bear the weight of the system full of water.

WALL INSTALLATION

The device is designed for wall-mounting installation and, therefore is supplied with two brackets in the back. The installer has to fix coach screws M10x80, lock washer M10 and screw anchors 12×60. In addition, there are two holes on each side to adjust and regulate the silent blocks supplied to the wall.INDOL-EH100UV4-Heat-Pump-Heater-FIG-1 \(3\)

AIR CONNECTION

Indol-UV4 unit has two air connections located at the top cover of the system. There are different installations possibilities:INDOL-EH100UV4-Heat-Pump-
Heater-FIG-1 \(4\)

Since the temperature of the exhaust air is lower than the intake air flow, the user can recover this cold air to refresh a room. In this case, it is recommended to install a double duct, one to the room and the other to outdoors. Using a gate, the user can stop the airflow conducting it to outdoors when cooling isn’t needed.

IMPORTANT:

  • Do not use a flexible duct! Only smooth PVC pipe is allowed.
  • Do not use an anti-insect grid.

When the inlet and outlet ducting is needed, use only rigid smooth PVC tubes. The pressure drop in the whole air circuit (pipes and accessories) must be lower than the static pressure of the system, 50 Pa. The following table shows the allowed total pipe length (intake + exhaust). The equivalent length of any accessory installed in the circuit must be subtracted to the maximum allowed pipe length:INDOL-EH100UV4-Heat-Pump-Heater-FIG-1
\(30\)

SUCTION FILTER

  • The system includes an air intake filter for the protection of all the elements of the refrigeration circuit.
  • This filter should be checked every 6 months to verify that it has not been clogged.
  • To do this, remove the filter from the suction duck and check if the channels allow air passage. Otherwise, wash it with water or replace it with a new one.
  • If you notice that the system does not heat up, check the condition of the filter.
  • A clogged filter affects the life-cycle performance and hot water production of the system.

Plumbing

Connection suggestions

  1. Water in
  2. Shut-off valve
  3. Check valve
  4. Safety valve
  5. Drainage
  6. Hot water

When the plumbing connections are connected, ventilate the system and then fill the tank with water On the back of the unit there is a connection for condensed water from the heat pump. Connect hose 20 mm and pull to drain.

ELECTRICAL CONNECTION

The electrical connection of the equipment is 230 V/1/50 Hz.

  • PV: Photovoltaic connection
  • LPS: Low-pressure switch
  • HPS: High-pressure switch
  • NTC1: Water temperature probe
  • NTC2: Ambient temperature probe
  • AND: Not used
  • D: Display
  • VS: Solenoid valve
  • R: Electrical heater
  • K: Compressor
  • F: Fan
  • 230 VAC: Power supplyINDOL-EH100UV4-Heat-Pump-Heater-FIG-1 \(6\)

COMMISSIONING CONTROLLER

User interface descriptionINDOL-EH100UV4-Heat-Pump-Heater-FIG-1
\(7\)

INSTALLATION Switching on
After full installation of the water heater (power and water pipes connected) and after the water heater tank is full of water, power can be turn ON .INDOL-EH100UV4-Heat-Pump-Heater-FIG-1 \(8\)

Unlocking the keypad

  • When 30 have elapsed without the keys being pressed, the display will show the “Loc” label and the keypad will lock automatically.
  • Touch any key until the screen shows “UnL”, to unlock the keypad.

Displaying the operating mode
At first initial power ON, the product goes, by default, in Eco mode. By touching one time the Lay the controller will chaw, tha made in narration in this momentINDOL-EH100UV4-Heat-Pump-Heater-FIG-1
\(11\)

  • ECO Mode: Heating only by heat pump technology
  • Auto Mode: Heating by heat pump and electric heater only if the water temperature falls drastically
  • OverBoost Mode: Simultaneously heating by heat pump and electrical heater to achieve the temperature setpoint as quickly as possible
  • Defrost: Defrost cycle active
  • Photovoltaics/ Timer: Automatic working due to the existence of surplus energy from PV installation or Off-Peak Rate
  • Antilegionella: Automatic disinfection by thermal shock

Changing operating modeINDOL-EH100UV4-Heat-Pump-Heater-FIG-1
\(12\)

To change the operating mode, touch the seconds. key for The screen will show blinking the selectable operating modes. Use the and keys to select the operating mode.

  • Touch to confirm or to cancel.
  • The screen will show again the water temperature.

ECO Mode

  • ECO mode: Maximum savings. The system heats water only by heat pump technology.
  • This is the factory default mode.
  • Setting the ECO temperature setpoint
  • The water temperature set point in ECO mode can be changed with the SPI parameter.INDOL-EH100UV4-Heat-Pump-Heater-FIG-1 \(18\)
  • Touch the key and select SP1. Touch to confirm.
  • The display will show the programmed temperature.
  • Touch it to select the desired temperature.
  • Touch to confirm or to cancel.

AUTO Mode

  • It maintains a steady temperature by the heat pump and only uses the electrical heater if the temperature falls drastically
  • Setting the AUTO temperature setpoint
  • The water temperature set point in AUTO mode can be changed with the SP2 parameter.INDOL-EH100UV4-Heat-Pump-Heater-FIG-1 \(21\)
  • Touch the key and select SP2. Touch to confirm.
  • The display will show the programmed temperature
  • Touch or select the desired temperature.
  • Touch to confirm or cancel

OVERBOOST Mode
Select this mode to achieve fast heating by using simultaneously heat pump and electric heater. This mode Works as a rapid heating. Once the setpoint temperature is reached, the system returns to the initial mode.

  • If Overboost mode is switched on when the system Works from ECO mode: The system heats the water up to SPl and then returns to ECO again
  • If Overboost mode is switched on when the system Works from Auto mode: The system heats the water up to SP2 and then returns to Auto again

When Overboost mode is active, the display automatically changes showing the water temperature and Obs.INDOL-EH100UV4-Heat-Pump-Heater-FIG-1
\(22\)

Cancelling the Overboost Mode

  • Touch for 2 seconds, Obs will blink on the screen
  • Touch for 2 seconds again, Obs will blink faster
  • Touch and the mode will be changed for the initial mode.

Parameter SP3 allows to set the minimum temperature that Overboost can be advised. To change its value, follow the procedure:INDOL-EH100UV4-Heat-Pump-
Heater-FIG-1 \(24\)

  • Touch and select with and SP3. Touch to confirm.
  • The display will show the programmed temperature.
  • Touch or to select the desired temperature.
  • Touch to confirm or to cancel.

Photovoltaic input

  • Working in this mode, the system automatically heats the water due to electric energy surplus or by Off Peak rate.
  • The parameters of this mode can only be changed by the Insta seller’s Menu. Contact the technician for more information.
  • The system can be combined with and Photovoltaic Inverter to take advantage of the surplus energy generated by the panels, by forcing the system to work and storing this energy in useful hot water.
  • The system has the electric boar two terminals to connect a zero-voltage contact.
  • When the contact is closed, the system automatically changes to Photovoltaic mode and the heat pump and electric heater work to achieve the programmed temperature. When the contact is opened, the system returns to the previous mode.
  • This contact can be also used for Off Peak Rates. To do it, connect into the contact a timer with a zero voltage output.

Displaying/deleting compressor functioning hoursINDOL-EH100UV4-Heat-Pump-
Heater-FIG-1 \(26\)

Antilegionella

  • The anti-legionella feature reduces the risk of the development of bacteria in the tank.
  • The system performs a thermal shock and disinfection to avoid any risk of conditions that might cause the development of bacteria.
  • The disinfection is made automatically once a month, reaching a temperature of 65 °C.
  • Anti-legionella can be disabled or enabled in the installer menu.
    • IMPORTANT: When the system is switched off from the electrical supply, the internal hour counter for anti-legionella disinfection is reset. For this reason, the system will perform a thermal shock disinfection before the time expected.

AlarmsINDOL-EH100UV4-Heat-Pump-Heater-FIG-1 \(31\)

LADDA NER HITEMP APPEN

Documents / Resources

| INDOL EH100UV4 Heat Pump Heater [pdf] User Manual
EH100UV4 Heat Pump Heater, EH100UV4, Heat Pump Heater, Pump Heater, Heater
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

INDOL User Manuals

Related Manuals