Indol EH160 EcoHeat Refrigerant Heat Pump Instruction Manual

June 13, 2024
INDOL

Indol EH160 EcoHeat Refrigerant Heat Pump

EH160

Product Information

Product Name: EH160 EH200 EH260
Manufacturer: Indol AB
Installation and User Manual: EH 160 – 200 – 260
Contents: Introduction, General indications, Safety notes, Condensate drain, Air connection, Equipment’s serial number, Maintenance, End of the equipment’s life cycle

Product Usage Instructions

Introduction

  • The product is manufactured by Indol AB according to the quality standards set by the European Union.
  • It incorporates top-quality materials and has undergone testing before leaving the facilities.
  • Carefully read the installation and start-up manual before handling the product.

General indications:

  1. Follow the instructions provided to avoid accidents or equipment malfunctions.
  2. Do not alter any permanent instructions, labels, or warning plates attached to the equipment.

Safety notes:

  • Incorrect or inappropriate use of the product can lead to hazardous situations, causing damage or injuries.
  • Follow the instructions provided to avoid any risks.
  • Install the minimum safety devices indicated in the manual (electrical and hydraulic) for proper equipment operation.

Condensate drain :
Refer to the specific instructions in the manual regarding the condensate drain.

Air connection :
Refer to the specific instructions in the manual regarding the air connection.

Equipment’s serial number:
The filling of the equipment’s serial number by technical staff is recommended.

Maintenance:
Refer to the maintenance section in the manual for detailed instructions on how to properly maintain the equipment.

End of the equipment’s life cycle:
Refer to the specific instructions in the manual regarding the end of the equipment’s life cycle.

Note : The information included in this document may be subject to modification by Indol AB without prior notice.

If you have any doubts or need assistance, please contact technical support.

Introduction
You have just acquired a product manufactured by Indol AB, we appreciate the trust placed in our company. This product has been manufactured following the quality standards set by the European Union, incorporating top-quality materials, and its proper functioning has been tested before leaving our facilities.

Through this installation and start-up manual, you will be guided for the correct setup of this product. It is essential to carefully read this manual before any handling to avoid issues arising from improper use of the product. The company Indol AB reserves the right to modify the information included in this document at any time without prior notice

General indications
The following instructions must be followed to avoid any accidents or equipment malfunctions. Please refer to them again if in doubt or contact technical support. Do not alter any permanent instructions, labels, or warning plates attached to the equipment.

Safety notes
The incorrect or inappropriate use of this product could lead to hazardous situations, causing damage or injuries to the user, third parties or even to the product itself or material goods. Follow these instructions to avoid any risks.

  • The installation of the minimum safety devices indicated in this manual (electrical and hydraulic) is necessary for proper equipment operation. The absence of any device may cause burns or other injuries in the event of a failure.
  • As a safety measure, earthing verification is also necessary. The earthing must comply with the applicable installation standards. Failure to implement this measure may result in accidents or death.
  • It is the responsibility of the installer to inform the user about the function and location of the safety devices installed on the equipment.
  • The water temperature at the equipment outlet may reach up to 70°C (depending on the model). Do not touch the pipes during operation to avoid the risk of burns.
  • The equipment must not be operated by minors or individuals with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, without supervision, unless they have been instructed on the safe use of the device and understand the associated risks.
  • Only perform the operations referred to in these operating instructions

Safety indications for refrigerant R134a
The R134a refrigerant in the heat pump circuit contains fluorinated greenhouse gases regulated by the Kyoto Protocol, making it harmful to the environment. It must not be released into the atmosphere, soil, or water system.

It is a non-flammable and non-explosive refrigerant under appropriate ambient temperature and pressure conditions. However, when pressurized with air or oxygen, or when mixed with other HFC fluids, the mixture can become flammable or reactive under certain conditions.

  • Do not bring flames or flammable sources near or inside the equipment.
  • Smoking is forbidden in the proximity and inside the installation compartment.
  • Do not expose the equipment to environments that can reach extremely high temperatures to avoid the risk of explosion due to increased internal pressure.
  • Avoid the accumulation of electrostatic charge.
  • Do not damage the pipes of the refrigeration circuit.
  • Do not consume polluted water with refrigerant.
  • There is a risk of freezing upon contact with the refrigerant.
  • In case of contamination with the refrigerant, wash with plenty of water. This water should be collected and stored separately for later disposal. In the case of detecting a leak, you should be aware of its danger and consider the following indications:
  • Do not inhale vapours or gases emanating from refrigerant circuit leaks. The refrigerant has a smell similar to ether.
  • Avoid the risk of injury from contact with refrigerant.
  • Do not bring any open flames near the area where the leak occurred, do not operate electrical appliances, and refrain from smoking.
  • Leave the contaminated enclosure and prevent third parties from entering.
  • Take off contaminated clothing before entering lunch areas.
  • In case of gas leakage or penetration into water bodies, soil, or sewage system, inform the authorities in charge.
  • Contact after-sales service.

The appliance is supplied with 950 g of R134a refrigerant gas inside the equipment. The device is provided with a charging or recharging valve to perform these operations if necessary. In any case, refill can only be carried out by the manufacturer or qualified professionals.

It is not a toxic product under normal conditions for human health. However, avoid skin and eye contact with the refrigerant at all costs. In case of an accident, here are some first-aid steps you can take:

Symptom Step

Inhalation| Remove the affected person from the enclosure and take them outdoors. Keep them in a resting position.

Administer oxygen if necessary.

Consult a doctor immediately.

---|---
Ingestion| Do not induce vomiting. Rinse the mouth with water and drink 200- 300 ml of water. Seek medical attention immediately.
Contact with skin| Rinse thoroughly with lukewarm water.

Do not remove clothes, which can stick to the skin.

If burns, blisters, or any other skin irritation appear, seek medical attention immediately.

Contact with

eyes

| Rinse with plenty of water or use an eyecup, with the eyelids open for at least 10 minutes. Consult an ophthalmologist immediately.

There are also the following health consequences due to improper use of the refrigerant:

  • Burns
  • Hearth rhythm disturbances
  • Death

In the event of a fire, the appropriate extinguishing means are:

  • Water
  • Carbon dioxide, CO2 (for example: fire extinguisher)

Collect the contaminated water used to extinguish the fire separately. Do not pour it into the sewage system. Firefighting personnel must wear appropriate respiratory equipment before acting.

Package contents
The ECOHEAT system comprises the following components:

  • ECOHEAT unit
  • Safety valve (6 bar) Bedöms denna vara för låg byt till max 9 bar
  • Silent-blocks
  • Drainage nozzle
  • Blockage for the condensate drain on the heat pump tray
  • User manual

Instructions for transportation and unpacking

  1. The unit is supplied packed into a wooden pallet properly secured to prevent damage during transport.
  2. The material used to the packing are recyclables, so dispose it in an appropriate container. Be careful when using knives or cutters to open the cardboard box so as not to damage the equipment.
  3. Use a forklift or hand pallet truck to transport the unit to the installation site, always introducing the forks into the bottom of the pallet being careful not to damage or knock over the unit.Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(3\)

In case of manual transport, it is forbidden to carry equipment with an inclination greater than 15º to the vertical for long period of time. Otherwise, the equipment should be in this position only for the necessary time. After transportation in this way, the equipment needs to remain still in a vertical position for at least 6 hours to ensure the proper return of oil within the equipment. All manual operations must always be carried out by minimum 2 people to prevent accidents.

In case you identify any damage at the time of the reception of the unit, it is mandatory to register it in the reception note of the transport company, and then, submit the complaint. For this reason, it is recommended to make a thorough visual inspection of the goods before signing the reception note

Technical information
All relevant technical information about the equipment is provided in this manual. However, according to regulations, Indol AB is available to provide additional information about the equipment if required.

The ECOHEAT equipment has been designed and manufactured in compliance with all applicable current regulations.

Operating principle

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(4\)

Parts of the unit

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(5\) Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig-
\(6\)

  1. Front cover
  2. EVCO touch control
  3. Plastic top cover
  4. Air filter
  5. Back cover
  6. Side covers
  7. Silent-blocks
  8. Electric heater 1500 W
  9. DHW probe NTC1
  10. PVC protective cover
  11. Low pressure switch
  12. High pressure switch
  13. Compressor
  14. Evaporator
  15. Solenoid valve
  16. Expansion valve
  17. Air box part 1
  18. Air box part 2
  19. Fan
  20. Drain fitting
  21. Air temperature probe NTC2
  22. Filter drier
  23. Heat pump tray
  24. Drain fitting (plugged)
  25. Fan capacitor
  26. Compressor capacitor
  27. Safety thermostat
  28. Terminal strip

Dimension drawings

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(7\)

  • EH160
  • EH200
  • EH260
A B C D E F
584 600 1311 91 541 219
584 600 1540 216 546 194
584 600 1907 216 913 194

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(8\)

G El: 230/50-1 (levereras med stickpropp) L Varmvatten ut: ¾“
H : Æ20 mm M Vatten in: ¾“
I Elpatron 1500 W / Temperatur sensor N Varmvatten cirkulation, ¾“
J Æ 150/160/200 mm O monteras innan uppfyllning
K Æ 150/160/200 mm

Technical data

Model                                                       EH160 EH200| EH260
---|---
Cylinder
Capacity (l)| 160| 200| 260
Maximum operating pressure (bar)| 9
Heat pump data
Load profile| L| L| XL
Heating capacity range (W)| 1100 – 1841
Power input range (W)| 496 – 600
Water heating energy efficiency, average climate (%)| 107| 107| 112
COP (average climate, 7ºC)| 2.56| 2.57| 2.72
COP (warm climate, 14 ºC)| 2.80| 3.10| 3.00
Energy efficiency class| A| A| A
Ambient temperature range (ºC)| -12 / 40
DHW temperature range (ºC)| 35 / 60
Maximum DHW temperature with HP (ºC)| 55
Refrigerant / Charge (g)| R134a / 950
Sound power (dB(A))| 53
Sound pressure at 1 m / 2 m (dB(A))| 45 / 39
Auxiliary electric heater
Electrical heater power (W)| 1500
Maximum absorbed power (W)| 2100
Maximum water temperature with electrical heater

(ºC)

| 70
Air data
Maximum air flow rate

3

(m /h)*

| Low speed| 264
High speed| 370
Maximum available static

pressure (Pa)

| Low speed| 70
High speed| 100
Connection diameter (mm)| 150 / 160 / 200
Connections
Power supply (V/ph/Hz)| 230 / 1 / 50
Inlet/outlet/recirculation water connections (inch)| ¾ M

Nameplate
The nameplate contains product details and important information:

  • Type of product
  • Date of production
  • Serial number (also available in this manual)
  • Power supply
  • Operating pressure
  • Electrical supply
  • IP class
  • Type of refrigerant

The nameplate must always be accessible and remain legible throughout the equipment’s entire lifespan. If it becomes damaged or illegible, replace it immediately. Never remove or cover the nameplate or labels affixed to the heat pump equipment

Installation steps

Before starting the installation, the installer must check the availability of all the necessary components and tolls:

  • Drill
  • Screwdriver
  • Hydraulic installation components
  • Electric installation components

Once it has been checked that it is available all the necessary components and tools, the installer should follow the next steps:

  1. Placing the ECOHEAT
  2. Hydraulic installation
  3. Air connections
  4. Electric installation
  5. Commissioning

The original design allows easy removal of the casing, the front cover, to make easier access during installation, inspection and maintenance tasks.

If the electrical supply to the dwelling and the product is interrupted during an extended absence, request a specialized installer to protect it from frost to prevent fatal damage to the product.Before starting the installation, the installer must check the availability of all the necessary components and tolls:

  • Drill
  • Screwdriver
  • Hydraulic installation components
  • Electric installation components

Once it has been checked that it is available all the necessary components and tools, the installer should follow the next steps:

  1. Placing the ECOHEAT
  2. Hydraulic installation
  3. Air connections
  4. Electric installation
  5. Commissioning

The original design allows easy removal of the casing, the front cover, to make easier access during installation, inspection and maintenance tasks. If the electrical supply to the dwelling and the product is interrupted during an extended absence, request a specialized installer to protect it from frost to prevent fatal damage to the product.

Placing ECOHEAT
The place where the system will be installed should allow an easy access in order to make maintenance work or inspection; It is recommended to meet the following minimum distances in the enclosure:

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(10\)

The equipment has been designed for indoor installation. The enclosure must be equipped with the following minimum requirements:

  • Minimum temperature 7 ºC.
  • Adequate water and electricity supplies.
  • Drainpipes to discharge water in case of emptying the tank, using the safety valve or breaking the hydraulic circuit; in addition, for the condensation water outlet connection.
  • For potential major water leaks, a containment system or procedure.
  • Sufficient illumination.
  • Volumetric capacity not less than 30 m3. Otherwise, adequate minimum ventilation must be ensured.
  • Dry and protected from frost.

The air outlet temperature of the device is approximately 5-10°C below the inlet temperature.  So, in case that the exhaust air would not be ducted, the room temperature will be considerably reduced. Besides these factors, it is important to consider the following guidelines regarding the location:

  • The surface where the unit will be installed must be capable of supporting its weight. Moreover, it should be flat or have a maximum inclination of 2º.
  • Since the equipment may cause vibrations or noise, it is recommended to install it away from resting areas.
  • Installer must install the supplied Silent blocks to avoid the transmission of vibration.

There are other possible connection options; as some examples below:

  • Connection to recirculation
  • Connection to thermal solar installation
  • Connection to support existing DHW equipment (heater, boiler, etc.)

In case the recirculation connection, it is recommended to install a timer on the return recirculation pump. Once the hydraulic connections are made, vent the circuit to avoid the air inside the installation.

Condensate drain
The condensation in the evaporator could produce a constant water flow that has to be drained properly; also, to avoid unwanted odours of equipment in ambient air. The condensate drain is in the back or in the front of the system. (Illustration 5, H). Connect the condensate drain to the wastewater network making a siphon through a flexible tube with inner diameter 20 mm. Ensure that water can flow freely

Air connection
The ECOHEAT unit has two air connections located on the top cover of the equipment. There are different connection possibilities, as shown below, which can be installed in compliance with the current regulations. However, the cold air outlet must always be ducted to the outside of the enclosure, except when it is in technical room.

60-EcoHeat-Refrigerant-Heat-Pump-fig- \(12\)

There is the possibility of ducting the cold air to a specific area for cooling. Through a damper, it can be redirected outside when cooling that area is not necessary. The ECOHEAT design provides the option to choose between 3 different pipe diameters for air ducting. The selection of the pipe size to be used is at the discretion of the installer/technician responsible for the design and calculation of the installation.

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(13\)

When ducting air connection, the tube which will be used for must be rigid PVC or a material with similar stability.

For the accessories, the following table is provided with the equivalent distance of pressure drop. The values are calculated for the total length of suction and air discharge ducts. Special attention should be given when installing the following elements and their pressure drop:

  • Corrugated pipe for air conduction
  • Anti-insect grids on the end of air inlet and outlet tubes

Accesories

|  | Equivalent distance of pressure drop (m)
---|---|---
Æ 150| Æ 160| Æ 200
Maximum available length| V1| 11| 15| 30
V2| 16| 30| 50
Elbow 90º| V1| 1.5| 2.0| 2.5
V2| 1.5| 2.5| 3
Vertical tube (1 m)| V1| 1| 1| 1
V2| 1| 1| 1
Flexible/corrugated pipe| V1| 5| 5| 5
V2| 5| 5| 5
Anti-insect grid

(at air inlet and outlet)

| V1| 5| 5| 5
V2| 5| 5| 5

To prevent condensation, it is recommended to insulate the air evacuation pipes and air duct connections with a vapor-tight thermal coating.

Suction filter
The system includes in the air inlet a filter for the protection of all the elements of the refrigeration circuit.If you notice that the system does not heat up, check the condition of the filter. A clogged filter affects the life- cycle performance and hot water production of the system. The filter can be removed and cleaned as indicated in the Maintenance section.

Electrical connection
The power supply of the system is 230 V /1 PH /50 Hz. The unit must be connected to minimum a 10 A power socket with proper earthing. The connections are lodged in a sealed electrical box according to regulations for isolated containment of the electrical components of the refrigerant. The electric strip is an element that can be manipulated inside the electrical box. Before performing any wiring work on the electrical circuit, disconnect the power supply and ensure that there is no residual energy in it. An incomplete earthing connection can cause malfunction or electrical shock. Before making the electrical connections, follow the instructions below to verify it:

  1. Check the socket and connector are dry,
  2. Plug in and leave the equipment connected to the supply for half an hour.
  3. Disconnect the equipment and check the status of the It should not be too hot (+50 ºC).
  4. If it does not work well, you should change the socket or connect the unit in a different one..

The electrical connections must always be made without voltage, only by authorized installers and in compliance with the current national electrical regulations.  If the power cord supplied with the appliance is damaged, it must be replaced by the manufacturer, their authorized service agent or a person with equivalent experience to avoid any potential hazards.

The connection scheme is shown in the following picture:

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(14\)

PV Photovoltaic connection VS Solenoid valve
LPS Low pressure switch R Electrical heater
HPS High pressure switch K Compressor
NTC1 Water temperature probe F Fan
NTC2 Air temperature probe 230 VAC Power supply
D Display  

Commissioning. Controller
Before starting the ECOHEAT, the tank must be filled with water prior to turning on the equipment. The electric heating element may be damaged if the equipment operates without water. The heating time to reach hot water temperature in the equipment will depend on the outside  weather.

User interface description

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(15\)

1. Confirm / key lock 4. Up
2. ON / Stand-by / Escape 5. Defrost / Mode change
3. Down 6. Anti-legionella

Meaning of the icons on the screen:Indol-EH160-EcoHeat-Refrigerant-Heat-
Pump-fig- \(16\)

Use

Switching on/off
When the equipment is plugged, the screen will only display the inscription “oFF”. To turn on the equipment, press and hold the key for 2 seconds. The screen Will illuminate with all the icons.

  • Plug the equipment into the electrical supply. 2 s
  • The display always shows the water temperature.

To switch off the equipment, do the same procedure: press and hold down the key for 2 seconds.

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(19\)

Unlocking the keypad
After 30 seconds of inactivity, the screen locks for safety. To unlock, press and hold any key for 1 second until the “UnL” message appears

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(20\)

Displaying the operating mode
At first power-on of the unit is set to Eco mode by default. By touching one time the key, the current operation mode Will be shown on the screen:

  • Eco mode: Heating only by heat pump technology.
  • Auto mode : Heating by heat pump and electric heater, only if the water temperature falls drastically.
  • Overboost mode : Simultaneously heating by heat pump and electrical heater to achieve the temperature setpoint as quickly as possible.
  • Ventilation mode: The fan provides better air circulation through a special function. It has 2 settings.
  • Defrost: The equipment is performing automatic defrosting.
  • Photovoltaics/Timer: Forced operation of the equipment due to the existence of electrical energy, excess of the photovoltaic network or by reduced tariff schedule.
  • Anti-legionella : Automatic disinfection by thermal shock in progress.

Changing operating mode
To change the operating mode, press the key once. The display will flash the selectable operating modes. Choose the mode with and keys. To confirm your choice, press ; or press to cancel this operation. Upon completion, the display will show the DHW tank temperature again.

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(35\)

Displaying/deleting compressor functioning hours

If the equipment turns off again, it is necessary to check the status of the high-temperature safety thermostat or consult with a technician.

Operating modes

Eco mode
Eco stands for economic, so maximum savings. The system heats water only by heat pump technology. This is the default mode. The water temperature setpoint in Eco mode can be changed with the “SP1” parameter.

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- 49

Modo Auto
It remains a steady temperature by the heat pump and only use the electrical heater if the temperature falls drastically. The water temperature setpoint in Auto mode can be changed with the “SP2” parameter

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- 50

Overboost mode
This mode achieves a fast heating by using simultaneously heat pump and electric heater. This mode works to get hot water quicker than using other operating modes. Once setpoint temperature has been reached, initial mode will get back:

  • If Overboost is activated while Eco mode is operating: The equipment heats up to the temperature SP1, and then returns to Eco mode.
  • If Overboost is activated while Auto mode is operating: The equipment heats  up to the temperature SP2, and then returns to Auto mode. When the Overboost mode is active, the display alternately shows the tank temperature and Obs.

Parameter “SP3” is used to select the minimum temperature at which the Overboost mode can operate:

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- 51

Ventilation mode
The ventilation mode is an additional function in ECOHEAT that allows better air circulation in the dwelling through a special setting of the fan. This mode is disabled by default.

Once configurated, 2 settings are available:

  • “FNC”: Choose the fan speed when the compressor is running.
  • “FCF”: Set ventilation mode when the compressor is not working.

In both settings 2 speeds are available: low (“LoU”) and high (“HiG”). In “FCF” settig also turning off this mode is possible (“OFF”).You can configure any of the 2 settings at any time: for example, put the “FCF” configuration when the compressor is still running. The set configuration will start to work when the equipment is started that way.

Photovoltaic input
Working on this mode, the system automatically heats the water due to electric energy surplus or by off-peak rate. The parameters of this mode can only be configured from the installer menu. Contact the technician if you want to make any modifications. The system can be combined with and photovoltaic inverter to use the surplus energy generated by the panels, by forcing the system working and storing this energy in useful hot water. The system has in the electric board two terminals to connect a zero-voltage contact.

  • When the contact is closed, the photovoltaic function (“SP6”) and the heat pump are automatically activated, and the heating element operates together until the photovoltaic setpoint temperature is reached.
  • Once the contact is open, the equipment returns to its previous operating mode.

These terminals can also be used to take advantage of reduced tariffs. Connect a time switch with a voltage-free contact to the terminals.

Anti-legionella mode
The anti-legionella feature reduces the risk of development of bacteria in the tank. The system performs a thermal shock disinfection to avoid any risk conditions that might cause the development of bacteria. The disinfection is performed automatically, reaching a temperature of 70°C.

Anti-legionella can be disabled or enabled in the installer menu, but it is highly not recommended:

  1. Press button and “Ant” will turn on the screen.
  2. Press button to start.

The anti-legionella mode cannot be cancelled once it is activated. If the equipment is disconnected from the power supply, the anti-legionella timer will reset, and the equipment will perform disinfection before the set time again.

Manual reset
In case of an electrical failure in the automatic reset of the ECOHEAT thermostat, it is possible to perform this task manually following the instructions below:

  1. Remove the front cover.
  2. Press once the button on the side of the electrical box.

Once done, the equipment should be put back into operation as usual.

Alarms y solutions

Alarms Meaning Solution

Pr1

|

Water temperature probe

| Check the temperature probe

integrity and the electrical connection.

Pr2

|

Evaporator temperature probe

| Check the temperature probe

integrity and the electrical connection.

AL| Low temperature|
AH| High temperature|

LHP

| Low pressure switch / Device is

blocked

| Switch the device off and on.
HP| High pressure switch| Switch the device off and on.

FiL

|

Compressor maintenance alarm

| By touching any key, the compressor functioning hours will

be deleted

UtL| Evaporator failure| Switch the device off and on.
Common failures and possible solutions

Failure| Reason| Solution
The controller does not turn on by pressing the power button.| The unit is disconnected.| Check if the product is connected to the power

supply.

The power supply has been interrupted.| Check that there has been no power outage and that the product is correctly connected to the electrical supply. The product will start automatically when the power supply is restored. If the error persists, contact an

authorized professional.

The heat pump has stopped working.

| The water temperature setpoint in the current operating mode has been

reached.

| Check the hot water temperature and the setpoint temperature.
The inlet air temperature is off the limits established in the technical data table.| Check that the additional energy source (electric heater) is activated. When the inlet air temperature returns to its operating range, the heat pump will

start operating again.

Lack of hot water.| A larger amount of hot water is being consumed than the

tank’s capacity.

| Wait until the hot water tank has enough hot water again.
The programmed running time (if it’s set up) of the heat

pump is too short.

| Increase the running time.
The setpoint temperature is too low.| Increase temperature. (SP1, SP2: consult Commissioning. Controller

section)

Suction filter is dirty.| Clean the filter as indicated.
Heat loss in the hydraulic system.| Check the entire hydraulic installation and possible leaks.

Failure| Reason| Solution
There’s water around the equipment.| The condensate evacuation hose is partially or

completely blocked.

| Check the condensate evacuation hose.
---|---|---
The condensate discharge hose is bent and forms a

depression.

The condensate discharge hose is not installed.| Contact authorized

installation personnel who did the installation.

Activation of the safety valve due to excess pressure in the water inlet and improper or

poorly installed piping.

| Contact authorized installation personnel who did the installation.
Other failures|  | Contact authorized

installation personnel.

Maintenance

To perform maintenance and cleaning tasks on the equipment, it is recommended to turn it off. Once a year, it is recommended to perform a technical inspection to verify the proper functioning of all parts of the equipment. Please consider the following instructions regarding maintenance for the correct operation of the ECOHEAT:

  • Do not use any means to accelerate the defrosting process. The equipment handles this  procedure automatically.
  • Check the stability of the equipment on the support surface periodically

Unit’s part                                                      Maintenance duty

Air system

| Maintain a ventilated environment.|

Indol-EH160-EcoHeat-Refrigerant-Heat-Pump-fig- \(47\)

Illustration 14: Cleaning of the suction filter

Periodically check for obstructions in the openings that allow air circulation in the

location where the equipment is installed.

Check the suction filter every 6 months to ensure it has not become clogged. If it is,

replace it with a new one.

Remove the filter from the suction duct and check if the channels allow air to pass through. If not, wash the filter with water or replace it with a new one.

Hydraulic system

| Verify the proper functioning of the safety valve by manually activating it, at

least once every 6 months.

Check that there is no obstruction to the flow of water towards the safety

valve.

Verify that the pressure at the equipment’s inlet is lower than 6 bar.
Check that the air pressure in the expansion vessel has the indicated nominal

pressure by the manufacturer.

Check the proper drainage of the drain tube: Look for blockages in the equipment’s drain openings and in the pipes leading to the drain.

If there is an obstruction, remove it by inserting a rod or blowing intensely

through the pipeline.

Electric system

| Verify the good condition of the internal wiring of the equipment and the

electrical supply.

Clean the dust and accumulated dirt on the electrical components with a dry

cloth.

For cleaning the equipment’s covers, use a damp cloth with a little soap. Do not use aerosols, abrasive products, polishers, or cleaning products containing solvents or chlorine.

If you need to move and reinstall the equipment, contact qualified personnel to avoid incorrect installation that may lead to significant risks such as leaks, fires, or electrical shocks

End of the equipment’s life cycle
If the equipment reaches the end of its life cycle, all the refrigerant must be removed before proceeding with its final disposal. For the replacement/disposal of refrigerants and oils, contact the manufacturer to provide the relevant instructions to minimize emissions and environmental contamination.

Do not dispose of the product with household waste. It must be handled according  to the proper waste treatment procedure in compliance with current regulations. Please take the equipment to the nearest recycling centre that collects used electrical or electronic appliances. Under no circumstances burn or puncture the equipment

List of spare parts
The components referenced in this table are in the Components of the Equipment chapter (page 11).

Reference number Part Unit Reference code
1. Front cover 1 Consult manufacturer
2. EVCO touch control 1 R10269
3. Plastic top cover 1 R10254
4. Air filter 1 R10025
5. Back cover 1 Consult manufacturer
6. Side covers 2 Consult manufacturer
7. Silent-blocks 4 R10042
8. Electric heater 1500 W 1 R10026
9. DHW probe NTC1 1 R10041
10. PVC protective cover 1 R10266
11. Low pressure switch 1 Consult manufacturer
12. High pressure switch 1 Consult manufacturer
13. Compressor 1 Consult manufacturer
14. Evaporator 1 Consult manufacturer
15. Solenoid valve 1 Consult manufacturer
16. Expansion valve 1 Consult manufacturer
17. Air box part 1 1
18. Air box part 2 1
19. Fan 1 Consult manufacturer
20. Drain fitting 1 R10261
21. Air temperature probe NTC2 1 R10041
22. Filter drier 1 Consult manufacturer
23. Heat pump tray 1 Consult manufacturer
24. Drain fitting (plugged) 1 R10270
25. Fan capacitor 1
26. Compressor capacitor 1
27. Safety thermostat 1 R10260 / R10271
28. Terminal strip 1

Warranty

Component Warranty period
Stainless steel 2205 tank 5 years
Stainless steel 444 tank 3 years
Electrical, electronic and mechanical removable components 2 years

MANUFACTURER WARRANTY CONDITIONS
The warranty exclusively covers productions faults of the product, excluding any liability for any material damage or injury that results directly or indirectly from the use of this product.

It is important to keep the purchase invoice and other documents related to the installation in a safe place. The warranty takes effect from the moment that the system is installed, perfectly justified via the commissioning file correctly completed and sent to the factory within 2 months, or in absence of this justification, the date that shall be take into consideration is the invoice date. The installer or distributor of the product is the solely responsible for compliance with the installation rules given by the manufacturer.

Failures or incidences due to the following reasons are excluded from the warranty:

  • Handling or repair the product by unauthorised personnel.
  • Damage caused by impact or fall during handling the product after it leaves the factory.
  • To exceed the maximum accumulation temperature. The maximum accumulation temperature in all buffer tanks, unless otherwise indicated by Indol, is 85 ºC. The most restrictive operating temperature range of those indicated in this document, data sheet, equipment manual and identification label will always prevail, contrary indication expressed by Indol.
  • Damage to the tank, result of malfunction from the overpressure limiting valve. Maximum 3 bars in the secondary, 9 bars in the primary and 9 bars in consumption and failing that indicated in the identification label of the equipment, applying as maximum pressure of each circuit the most restrictive.
  • Location of the product at any place subject to high temperature, humidity, inclemency, frost, aggressive environment…
  • Fault caused by an erroneous installation, which makes the product work out of its design conditions.
  • Faults caused by not having installed the supplied security group or incorrect installation thereof.
  • Overvoltage power supply (grid, beam…).
  • Faulty electrical connection, insufficient wire section, non-compliance with electrical schemes…
  • Use water within any of the following criteria.

Stainless steel 2205 tank Stainless steel 444 tank

800 mg/L total of chlorine derivatives

chlorides

| > 250 mg/L total of chlorine derivatives

chlorides

---|---
Calcium carbonate (CaCO3) content > 200

mg/L

| Calcium carbonate (CaCO3) content >

200 mg/L

50 mg / L free carbon dioxide| > 50 mg / L free carbon dioxide
Water pH less than 6 and greater than 8.5| Water pH less than 6 and greater than 9
Electrical conductivity (25 °C) > 500 µS/cm| Electrical conductivity (25 °C) > 750

µS/cm

Saturation index below -1 and over 0,8 (65

°C)

| Saturation index below -1 and over 0,8

(80 °C)

In general, any condition that exceeds the maximum allowed values

  • Fault due to galvanic corrosion result from direct connection of copper pipes without electrolytic sleeve.
  • Installation of the product in a manner not in accordance with the operating  instructions.
  • Damages result from problems that could not be detectable due to the location of the system (hardly accessible place) and that could have been avoided by a prompt reparation of the product.
  • Switch on the heating system without filling the tank (dry heating).
  • Any modification of the product without prior agreement with the manufacturer or use  spare parts non-authorized or non-supplied by the manufacturer.Based on these considerations, the warranty comprises in replacing the faulty component to the Installer or Distributor. Transport cost, labour or any compensation are excluded from the warranty.

The fault in single components never comprises the replacing of the product. The installer or distributor is responsible of the changing or reparation of the defective part. The warranty of the replaced spare part has the same vigour as the product, shall not entail hence the warranty period to be extended or a new warranty period to commence

After-sales service sheet

Indol AB. This company reserves the right to modify the information contained herein without prior notice.

V1REV0ES0823