INDOL EH130UV4 EcoHeat Pump User Manual

May 15, 2024
INDOL

INSTALLATION AND USER MANUAL
INDOL
EH100UV4
EH130UV4
Version 1

INTRODUCTION

This product has been manufactured according to the European Quality Standards, incorporates prime grade materials and its correct working has been tested before it leaves our facilities.
Through this Installation and User Manual, you will be guide towards the correct and safety installation of the product. It is necessary to carefully read this manual before making any handling to avoid problems arising from the misuse of the product.
The company reserves the right to modify the information included in this document at any time without prior notice.

GENERAL INDICATIONS

2.1. Safety notes
The incorrect or inappropriate use of this product could lead to hazardous situations, causing damage or injuries to the user, third parties or even to the product itself or material goods.

  • The installer has the responsibility to install the minimum safety devices (hydraulic and electrical) set out in this Manual. In case of failure, the lack of any device may cause burns or other injuries.
  • The installer has the responsibility to inform the user about the function and placement of the safety devices installed into the device and the installation.
  • The water outlet temperature could reach 70 degrees. Do not touch the pipes while the system is working to avoid any risk of burns.

2.3. Package contents
The INDOL-UV4 system comprises the following components:

  • INDOL-UV4 (according to model)
  • Silent-Blocks
  • Anchor screws
  • Safety valve
  • User Manual

2.4. Indications about transport and unpacking the unit
The unit is supplied packed into a wooden pallet properly secured to prevent damage during transport.
The materials used for packing are recyclables, so dispose it in an appropriate container.
Use a forklift or hand pallet truck to transport the unit to the installation site, always introducing the forks into the bottom of the pallet being careful not to damage the unit.
In case you identify any damage at the time of the reception of the unit, it is mandatory to register it in the reception note of the transport company, and then, submit the complaint.
For this reason, it is recommended to make a thorough visual inspection of the goods before signing the reception note.

TECHNICAL INFORMATION

3.1. Operating PrincipleINDOL EH130UV4 EcoHeat Pump -
operating

  1. The evaporator captures the thermal energy from the air through the refrigerant.
  2. The compressor compresses the refrigerant, increasing its temperature and pressure.
  3. The collected energy is transferred to water in the condenser. The accumulated water in- creases its temperature reaching up to 55 ºC.
  4. The refrigerant circulates to the expansion valve, where its pressure decreases to achieve the optimum conditions before entry into the evaporator.

3.2. Dimension drawingsINDOL EH130UV4 EcoHeat Pump -
parts

1 Hot water outlet, 3/4″ 5Exhaust air connection (160 mm)
2 Cold water inlet, 3/4 6 lntake air connection (10 mm)
3 Condensate drain 7 Electrical heater, 1500 W
4 Power spply, 230 V/ 1PH / 50 Hz

3.3. Technical data

Model EHI0OUV1                       EH130UV4

Cylinder
Capacity, L| 100130
Maximum operating pressure, bar| 10
Heat pump data|
Heating capacity range, W| 700— 1200
Input power, W| 180 — 300
Energy Efficiency Class| A+
Load profile| M
SCOP (14 °C)| 3,02| I 3,24
Refrigerant / Charge, g| RI 34a / 750
Minimum ambient temperature, ‘C Maximum water temp. HP, •C| -5
55
Maximum water temp. electrical heater, °C| 70
Electric data|
Power supply, V/ph/Hz| 230 / 1 / 50
Electric heater power, W| 1500
Maximum absorbed power, W| 1800
Air data|
Air flow, &fit| 200
Maximum pressure drop, Pa| 50
Intake/Exhaust connection, mm| 160
Other data|
Water connections, inch| 3 / 4

INSTALLATION STEPS

Before starting the installation, check the availability of all the necessary components and tools:

  • Drill
  • Screwdriver
  • Hydraulic installation components
  • Electric installation components

Once it has been checked that it is available all the necessary components and tools, the installer should follow the next steps:

  1. Placing the unit
  2. Hydraulic installation
  3. Air connections
  4. Electric installation
  5. Commissioning

PLACING INDOL-UV4 UNIT

The place where the system will be installed should allow an easy access to make maintenance work or inspection.
Air outlet of the unit is around 5-IO degrees below inlet temperature, so in case that the exhaust air would not be ducted, the room temperature will be considerably reduced.
Beside these factors, it is important to consider the following indications regards the installation site:
The system has been designed and manufactured for it indoors utilization. Install the system in a dry, frost-free room at a minimum temperature of 5 °C.
Installer must install the supplied silent blocks to avoid the transmission of vibration.
The wall where the system will be installed has to bear the weight of the system full of water.

WALL INSTALLATION

The device is designed for wall-mounting installation, therefore is supplied two brackets in the back. The installer has to fix coach screws M10x80, lock washer M10 and screw anchors 12×60.
In addition, there are two holes on each side to adjust and regulate the silent blocks supplied to the wall. INDOL EH130UV4 EcoHeat Pump -
install

AIR CONNECTION

Indol-UV4 unit has two air connections located at the top cover of the system.
There are different installations possibilities:
INDOL EH130UV4 EcoHeat Pump - CONNECTION

Since the temperature of the exhaust air is lower than the intake air flow, the user can recover this cold air to refresh a room. In this case, it is recommended to install a double duct, one to the room and other to outdoors. Using a gate, the user can stop the air  flow conducting it to outdoors when cooling isn’t needed.

IMPORTANT:

  • Do not use flexible duct! Only smooth PVC pipe is allowed.
  • Do not use anti-insect grid.

When the inlet and outlet ducting is needed, use only rigid smooth PVC be.
The pressure drop in the whole air circuit (pipes and accessories) must be lower than the static pressure of the system, 50 Pa. In the following table is shown the allowed total pipe length (intake + exhaust). The equivalent length of any accessory installed in the  circuit must be subtract to the maximum allowed pipe length:

Maximum length (PVC rigid pipe) 160 nm 14 m
Elbow 90° PVC 160 mm 3 equivalent meters
External grid 2 equivalent meters

SUCTION FILTER
The system includes in the air intake a filter for the protection of all the elements of the refrigeration circuit.
This filter should be checked every 6 months to verify that is has not been clogged. To do this, remove the filter from the suction duck and check if the channels allow air passage, Otherwise, wash it with water or replace with a new one.
If you notice_that the system does no heat up, check_the condition of the_filter.A_clogged filter gffects the life-cycle performance_and_hot water production_of the_system.INDOL EH130UV4 EcoHeat Pump -
Dimension

ELECTRICAL CONNECTION

The electrical connection of the equipment is 230 V/1/50 Hz.

PV: Photovoltaic connection
LPS: Low pressure switch
HPS: High pressure switch
NTC1: Water temperature probe
NTC2: Ambient temperature probeAND: Not used
D: Display
VS: Solenoid valve
R: Electrical heater
K: Compressor
F: Fan
230 VAC: Power supply

COMISSIONING. CONTROLLER.

10.1. User interface description

INDOL EH130UV4 EcoHeat Pump - Control

Symbol Meaning when it lights
Compressor switched on

Defrost active
Fan switched on
Alarm active
Compressor working hours exceeded
Unit in °C
Unit in “F
Electric heater switched on
Stand by

10.2. INSTALLATION. Switching on

After full installation of the water heater (power and water pipes connected) and after the water heater tank is full of water, power can be turn ON.

| 1. After filling the tank of water, connect the mains plug to the mains supply.
The screen will show the symbol.
2. Hold the key for 4 seconds. The
display will show the icons.
3. The screen will show the water temperature.
---|---

10.3. Switching OFF

To switch off the system, hold the key for 4 seconds.

10.4. Unlocking the keypad

When 30 have elapsed without the keys being pressed, the display will show the “Loc” label and the keypad will lock automatically.
Touch any key until the screen shows “Unl”, to unlock the keypad.

10.5. Displaying the operating mode
At trst imal power ON, the product goes, by default, in Eco mode. By touching one time the V key, the controller will show the mode in operation in this moment.

INDOL EH130UV4 EcoHeat Pump - install 5

10.6. Changing operating mode

INDOL EH130UV4 EcoHeat Pump - install 6

10.7. ECO Mode
ECO mode: Maximum savings. The system heats water only by heat pump technology.
This is the factory default mode.
Setting the ECO temperature setpoint
The water temperature set point in ECO mode can be changed with the SPl parameter. INDOL EH130UV4 EcoHeat Pump - eco

10.8. AUTO Mode
It maintains a steady temperature by the heat pump and only use the electrical heater if the temperature falls drastically.
Setting the AUTO temperature setpoint
The water temperature set point in AUTO mode can be changed with the SP2 parameter.

INDOL EH130UV4 EcoHeat Pump - auto

10.9. OVERBOOST Mode
Select this mode to achieve a fast heating by using simultaneously heat pump and electric heater.
This mode Works as a rapid heating. Once the setpoint temperature is reached, the system returns to the initial mode.
If Overboost mode is switched on when the system Works from ECO node. The system heats the water up to SPl, and then returns to ECO again
If Overboost mode is switched on when the system Works from Auto mode:. The system heats the water up to SP2, and then returns to Auto again
When Overboost mode is active, the display automatically changes showing the water temperature and Obs.

Cancelling the Overboost ModeINDOL EH130UV4 EcoHeat Pump -
cancelk

Parameter SP3 allows to set the minimum temperature that Overboost can be actived.
To change it value, follow the procedure:

INDOL EH130UV4 EcoHeat Pump - perameter

10.10. Photovoltaic input
Working on this mode, the system automatically heats the water due to electric energy surplus or by Off Peak rate.
The parameters of this mode can only be changed by the Installer’s Menu.
Contact with the technician for more information.
The system can be combined with and Photovoltaic Inverter to take advantage of the surplus energy generated by the panels, by forcing the system working and storing this energy in useful hot water.
The system has in the electric boar two terminals to connect a zero-voltage contact.

When the contact is closed, the system automatically changes to Photovoltaic mode and the heat pump and electric heater work to achieve the programmed temperature. When the contact is opened, the system returns to the previous mode.
This contact can be also used for Of Peak Rates. To do it, connect into the contact a timer with a zero­ voltage output.

10.11. Displaying/deleting compressor functioning hours

INDOL EH130UV4 EcoHeat Pump - Dispaly

10.12. Antilegionella
The anti-legionnella feature reduces the risk of development of bacteria in the tank.
The system performs a thermal shock disinfection to avoid any risk conditions that might cause the development of bacteria. The disinfection is made automatically once a month, reaching a temperature of 65 °C.
Anti-legionella can be disable or enable in the installer menu.

IMPORTANT: When the system is switched off from electrical supply, the internal hour-counter for antilegionella disinfection is reset. For this reason, the system will perform a thermal shock disinfection before the time expected.

10.13. Alarms

Alarms Meaning
Pr1 Water temperature probe alarm.

Check the temperature probe integrity and the electrical connection
Pr2| Water temperature probe alarm.
Check the temperature probe integrity and the electrical connection
Pr3| Evaporator temperature probe alarm.
Check the temperature probe integrity and the electrical connection
AL| Low temperature alarm
AH| High temperature alarm
LHP| Low pressure switch alarm/ Device blocked
Switch the device off and on
HP| High pressure switch alarm
Switch the device off and on
FIL| Compressor maintenance alarm
By silencing the buzzer, you delete the compressor functioning hours
Utl| Evaporator failure alarm
Switch the device off and on