Product Information
The product is a lighting fixture designed for professional use. It offers various features and settings that allow for customizable lighting effects. The fixture can be controlled manually using the control panel or through DMX configuration. It also has standalone configuration options, including automatic programs, sound-active mode, and manual mode.
Product Overview
The product is compact and lightweight, making it easy to transport and install. It is designed to provide high-quality lighting effects for various applications, such as stage performances, concerts, events, and installations. The fixture incorporates gobos, which add texture and patterns to the projected light. It can be mounted in different orientations and rigging options are available.
Product Dimensions
The dimensions of the product are not specified in the text extract. Please refer to the product user manual or packaging for detailed product dimensions.
Product Usage Instructions
Before You Begin
Before using the product, please ensure that you have the following:
- The product itself
- All the necessary accessories
To unpack the product, follow these instructions:
- Open the packaging carefully.
- Remove all the contents from the packaging.
- For any claims regarding missing or damaged items, please refer to the claims section in the user manual.
Introduction
- This section provides an overview of the product and its dimensions. Please refer to the user manual or product documentation for detailed information on the product’s features and specifications.
Setup
- This section covers the setup process for the product, including power connection, fuse replacement, power linking, mounting, orientation, and rigging. Please refer to the user manual for step-by-step instructions on each setup procedure.
Operation
- This section explains how to operate the product, including control panel operation, menu map, DMX configuration, gobos, DMX channel assignments and values, and standalone configuration.
- To control the product using the control panel, follow the instructions provided in the user manual.
- For DMX configuration, refer to the DMX Configuration section in the user manual for detailed instructions on setting the starting address, DMX personalities, and DMX values.
- To configure standalone operation, refer to the Standalone Configuration section in the user manual for instructions on using automatic programs, sound-active mode, sound sensitivity adjustment, and manual mode.
- Please note that these usage instructions provide a general overview. For detailed instructions on specific operations and settings, please refer to the user manual provided with the product.
Before You Begin
What Is Included
- Intimidator Scan 360
- Power cable
- Quick Reference Guide
Unpacking Instructions
- Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
Claims
- If the box or the contents (the product and included accessories) appear damaged from shipping or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate a claim. In addition, keep the box and contents for inspection.
- For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.
Text Conventions
Convention | Meaning |
---|---|
1–512 | A range of values |
50/60 | A set of values of which only one can be chosen |
Settings | A menu option not to be modified |
< ENTER> | A key to be pressed on the product’s control panel |
ON | A value to be entered or selected |
Symbols
Disclaimer
- Chauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage, or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident, or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make and does not commit to make any such revisions. Download the latest version from www.chauvetdj.com.
Intellectual Property
- The works of authorship contained in this manual, including, but not limited to, all designs, text, and images\ are owned by Chauvet.
- © Copyright 2023 Chauvet & Sons, LLC. All rights reserved.
- Electronically published by Chauvet in the United States of America.
- Chauvet, the Chauvet logo, Chauvet DJ, and Intimidator Scan 360 are registered trademarks or trademarks of Chauvet & Sons LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.
Safety Notes
ALWAYS:
- Connect to a grounded circuit.
- Connect to operating voltages as specified on the product’s spec sticker.
- Disconnect from power before replacing the fuse.
- Disconnect from its power source during periods of inactivity.
- Use a safety cable when suspending overhead.
- Heed all restrictions and warnings on the spec sticker.
- Mount in a location with at least 20 in (50 cm) of ventilation.
- Replace the fuse with the same type and rating.
- Use a clamp with a captive bolt when a single hanging bracket is used.
- In the event of a serious operating problem, stop using it immediately.
DO NOT:
- Open this product or attempt any repairs. It contains no user-serviceable parts.
- Look at the light source when the product is on.
- Use if the power cord is crimped or damaged.
- Disconnect by pulling on the power cord.
- Allow flammable materials close to the product when it is operating.
- Touch the housing when it is on.
- Block any ventilation holes/slots in the housing.
- Connect to a dimmer or rheostat.
- Carry the product with its power cord.
- Operate in temperatures higher than 104°F (40°C).
- Expose to environments that exceed the Ingress Protection (IP) rating.
- Expose to rain or moisture.
- Use outdoors.
- Expose to corrosive environmental conditions such as temperature, humidity, salinity, pressure, radiation, or shock.
- Set this product on a flammable surface.
- Keep this User Manual for future use. If the product is sold to someone else, be sure that they also receive this document.
Introduction
Product Overview
Product Dimensions
Setup
AC Power
- The Intimidator Scan 360 has an auto-ranging power supply, and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz.
- To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
- The listed current rating indicates the product’s average current draw under normal conditions.
- Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via a breaker or by unplugging it.
- Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse Replacement
- Disconnect the product from power.
- Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
- Pry the fuse holder out of the housing.
- Remove the blown fuse from the holder and replace it with a fuse of the exact same type and rating.
- Insert the fuse holder back in place and reconnect power.
Disconnect the product from the power outlet before replacing the fuse.
Power Linking
The product provides power linking via the outlets located in the back of the product. See the diagram below for further explanation.
Power Linking Diagram
- It is possible to power link up to 4 Intimidator Scan 360 products on 120 VAC or up to 7 products on 230 VAC.
- The power-linking diagram shown above corresponds to the North American version of the product ONLY! If using the product in other markets, consult with the local Chauvet distributor, as power linking connectors and requirements may differ by country or region.
Mounting
- Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.
Orientation
- The Intimidator Scan 360 may be mounted in any position; however, make sure adequate ventilation is provided around the product.
Rigging
- Before deciding on a location, always make sure there is easy access to the product for maintenance and programming.
- Make sure adequate ventilation is provided around the product.
- Make sure that the structure or surface onto which the product is being mounted can support the product’s weight (see the Technical Specifications).
- When mounting the product overhead, always use a safety cable. Mount the product securely to a rigging point, whether an elevated platform or a truss.
- When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.
- When power-linking multiple products, mount the products close enough for power-linking cables to reach.
- The rubber feet also serve as floor supports and allow for surface mounting. When mounting the product on the floor, make sure that the product and cables are away from people and vehicles.
Mounting Diagram
When using only one mounting clamp with this fixture, use a clamp with a captive bolt to prevent accidental loosening.
Operation
Control Panel Operation
To access the control panel functions, use the four buttons located underneath the display. Refer to the Product Overview to see the button locations on the control panel.
Button | Function |
---|---|
< MENU> | Press to find an operation mode or to back out of the current |
menu option
< UP>| Press to scroll up the list of options or to increase the numeric
value in a function
< DOWN>| Press to scroll down the list of options or to decrease the
numeric value in a function
< ENTER>| Press to activate a menu option or set the selected value in a
function
Menu Map
Refer to the Intimidator Scan 360 product page on
www.chauvetdj.com for the latest menu map.
Main Function | Programming Levels | Description |
---|---|---|
Address | 001–512 | Sets the DMX starting address |
Run Mode
| DMX| 8Ch| Selects DMX mode
12Ch
Slave| Sets unit to Slave mode
Auto| Sets unit to Auto mode
Sound| Sets unit to Sound-active mode
IR| Sets unit to infrared control mode
Manual
| Pan|
000–255
| Controls pan settings
Tilt| Controls tilt settings
Color| Selects color options
Gobo| Selects gobo options
Gobo Rotate| Controls gobo rotation effects
Prism| Selects prism effects
Focus| Controls focus
Dimmer| Sets dimmer value
Strobe| Controls strobe effects
Setup
| Pan Reverse| OFF| Normal pan operation
ON| Reverse pan operation
Tilt Reverse| OFF| Normal tilt operation
ON| Reverse tilt operation
Screen Reverse| OFF| Normal display
ON| Reverse display
Signal Loss
| Blackout| Turns the unit off when the DMX signal is lost
Hold| Holds the last setting when the DMX signal is lost
Auto| Sets the unit to Auto mode when the signal is lost
Sound| Sets the unit to Sound mode when the signal is lost
Sensitivity| 001–100| Sound sensitivity control
Indicator| OFF| Turns indicator on or off
ON
Flash if DMX| OFF| LED Indicator flashes when DMX is turned ON or
OFF
ON
Reset| Revert to factory settings
Sys Info
| Ver| V.| Displays software version
Running Mode| _| Displays current running mode
DMX Address| _| Displays current DMX mode
Temperature| _| Displays the product temperature in Celsius
DMX Configuration
- The Intimidator Scan 360 works with a DMX controller. Information about DMX is in the CHAUVET DMX Primer, which is available from the Chauvet website http://www.chauvetlighting.com/downloads/DMX_Primer_rev05_WO.pdf.
Starting Address
- When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses. If the starting address is set too high, access to some of the product’s channels could be restricted.
- The Intimidator Scan 360 uses up to 12 DMX channels, which defines the highest configurable address to 501. For information about the DMX protocol, download the DMX Primer from www.chauvetdj.com.
To select the starting address, do the following:
- Press
- Press
. - Use
or to select the starting address, from 001–512. - Press
.
DMX Personalities
The Intimidator Scan 360 has two DMX personalities: an 8-channel personality and a 12-channel personality. To select a DMX personality, follow the instructions below.
- Press
- Press
. - Use
or to select DMX. - Press
. - Use
or to select the DMX personality, from 8Ch or 12Ch. - Press
.
Gobos
DMX Channel Assignments and Values DMX Values
8Ch | 12Ch | Function | Value | Percent/Setting |
---|---|---|---|---|
1 | 1 | Pan | 000 ó 255 | 0–172° |
2 | 2 | Tilt | 000 ó 255 | 0–39° |
– | 3 | Pan/tilt speed | 000 ó 255 | Fast to slow |
3 | 4 | Color | 000 ó 006 |
007 ó 013
014 ó 020
021 ó 027
028 ó 034
035 ó 041
042 ó 048
049 ó 055
056 ó 062
063 ó 064
065 ó 189
190 ó 221
222 ó 223
224 ó 255
| Open Orange Lime Cyan Red Green Magenta Yello Blue White Split colors
Clockwise scroll, fast to slow Stop Counterclockwise scroll, slow to fast
4| 5| **Gobo wheel (see Gobos)| 000 ó 007**
008 ó 015
016 ó 023
024 ó 031
032 ó 039
040 ó 047
048 ó 055
056 ó 063
064 ó 071
072 ó 079
080 ó 087
088 ó 095
096 ó 103
104 ó 111
112 ó 119
120 ó 127
128 ó 189
190 ó 193
194 ó 255
| Open Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 7 shaking, slow to fast Gobo 6 shaking, slow to fast Gobo 5 shaking, slow to fast Gobo 4 shaking, slow to fast Gobo 3 shaking, slow to fast Gobo 2 shaking, slow to fast Gobo 1 shaking, slow to fast Open
Clockwise rotation, fast to slow Stop
Counterclockwise rotation, slow to fast
5| 6| Gobo rotation| 000 ó 063
064 ó 145
146 ó 149
150 ó 231
232 ó 255
| Gobo index Clockwise rotation, slow to fast Stop Counterclockwise rotation,
slow to fast Boomerang, short to long
6| 7| Prism| 000 ó 015
016 ó 127
128 ó 255
| No function Prism on (static) Clockwise rotation, slow to fast
7| 8| Focus| 000 ó 255| 0–100%
–| 9| Dimmer| 000 ó 255| 0–100%
8Ch| 12Ch| Function| Value| Percent/Setting
---|---|---|---|---
8
| ****
10
| ****
Strobe
| 000 ó 003
004 ó 007
008 ó 076
077 ó 145
146 ó 215
216 ó 255
| No function Open
Synchronized strobe, slow to fast Pulse strobe, slow to fast Random strobe, slow to fast
Open
**–| 11| Functions| 000 ó 007**
008 ó 015
016 ó 023
024 ó 031
032 ó 039
040 ó 047
048 ó 055
056 ó 095
096 ó 103
104 ó 111
112 ó 119
120 ó 127
128 ó 135
136 ó 143
144 ó 151
152 ó 159
160 ó 255
| No function Blackout on pan/tilt movement Blackout on color wheel movement
Blackout on gobo wheel movement Blackout on pan/tilt/color wheel movement
Blackout on pan/tilt/gobo wheel movement Blackout on pan/tilt/color wheel/gobo
wheel movement No function Pan reset Tilt reset Color reset Gobo reset No
function Prism reset Focus reset All reset No function
–| **12| ****Movement macros| 000 ó 007**
008 ó 023
024 ó 039
040 ó 055
056 ó 071
072 ó 087
088 ó 103
104 ó 119
120 ó 135
136 ó 151
152 ó 167
168 ó 183
184 ó 199
200 ó 215
216 ó 231
232 ó 247
248 ó 255
| No function Movement macro 1 Movement macro 2 Movement macro 3 Movement macro 4 Movement macro 5 Movement macro 6 Movement macro 7 Movement macro 8 Sound-active movement macro 1 Sound-active movement macro 2 Sound-active movement macro 3 Sound-active movement macro 4 Sound-active movement macro 5 Sound-active movement macro 6 Sound-active movement macro 7 Sound-active movement macro 8
Standalone Configuration
- Set the product in one of the standalone modes to control without a DMX controller.
- Never connect a product that is operating in any standalone mode to a DMX string connected to a DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller.
Automatic Programs
- To run the Intimidator Scan 360 in automatic mode, follow the instructions below:
- Press
- Press
. - Use
or to select Auto. - Press
.
Sound-Active Mode
To run the Intimidator Scan 360 in sound-active mode, do the following:
- Press
- Press
. - Use
or to select Sound. - Press
.
Sound Sensitivity
- To set the sound sensitivity on the Intimidator Scan 360, follow the instructions below:
- Press
- Press
. - Use
or to select Sound Sensitivity. - Press
. - Use
or to increase or decrease the sound sensitivity, from 001–100. - Press
.
The product will only respond to low frequencies of music (bass and drums).
Manual Mode
To operate the Intimidator Scan 360 manually through the menu, do the
following:
- Press
- Press
. - Use
or to select Manual. - Press
. - Use
or to select from Pan, Tilt, Color, Gobo, Gobo Rotate, Prism, Focus, Dimmer, or Strobe. - Press
. - Use
or to increase or decrease the value of the function, from 000–255. - Press
. - Repeat steps 3-6 until the product is set as desired.
Settings Configuration
Pan Reverse
To set the pan orientation on the Intimidator Scan 360, follow the instructions below:
- Press
- Press
. - Press
- Press
. - Use
or to select OFF (normal pan orientation) or ON (reverse pan orientation). - Press
.
Tilt Reverse
To set the tilt orientation on the Intimidator Scan 360, do the following:
Screen Reverse
To set the screen display on the Intimidator Scan 360, follow the instructions below:
- Press
- Press
. - Press
- Press
. - Use
or to select OFF (normal screen display) or ON (reverse screen display). - Press
.
Signal Loss
To set the action that the Intimidator Scan 360 does once the DMX signal is lost, follow the instructions below:
- Press
- Press
. - Press
- Press
. - Use
or to select Blackout (turns the unit off), Hold (retains the last setting), Auto (sets the unit to Auto mode), or Sound (sets the unit to Sound mode). - Press
.
Indicator
To enable or disable the LED indicator, do the following:
- Press
- Use
or to select Setup. - Press
. - Use
or to select Indicator. - Press
. - Use
or to select OFF (disabled) or ON (enabled). - Press
.
Flash if DMX
To enable or disable the LED indicator flashing to indicate DMX, do the following:
- Press
- Use
or to select Setup. - Press
. - Use
or to select Flash if DMX. - Press
. - Use
or to select OFF (will not indicate DMX) or ON (Will indicate DMX). - Press
.
Factory Reset
To restore the Intimidator Scan 360 to factory default settings, follow the instructions below:
- Press
- Press
. - Select Reset to revert the fixture to its default factory settings.
- Press
.
System Information
To view the system information on the Intimidator Scan 360, do the following:
- Press
- Use
or to select Sys Info. - Press
. - Select Ver (displays the fixture’s software version), Running Mode (displays the current running mode), DMX Address (displays the current DMX mode), and Temperature (displays the fixture’s current temperature in Celsius).
IRC-6 Infrared Remote Control
The Intimidator Scan 360 is compatible with the IRC-6 infrared remote control from Chauvet. To set the Intimidator Scan 360 to IR mode, follow the instructions below:
- Press
- Press
. - Press
or to select IR. - Press
.
IRC-6 Operation
Automatic Mode
- Automatic mode will enable the user to run the automatic programs on the product.
To turn on Automatic mode:
- Press
on the IRC-6.
To adjust the speed of the automatic program:
- Press
on the IRC-6. - Press <+> or <–> to increase or decrease the speed of the program.
Sound-Active Mode
- Sound-Active mode will enable the product to respond to the music.
To turn on Sound-Active mode:
- Press
on the IRC-6.
Sound Sensitivity
- To adjust the fixture’s sensitivity to sound:
- Press
on the IRC-6. - Press <+> or <–> to increase or decrease the sound sensitivity.
To set all LEDs to full intensity:
- Press <0> on the IRC-6.
Miscellaneous Operation
- To adjust the output level of the LEDs in manual color mode:
- Press <%> repeatedly on the IRC-6.
To black out the lights:
- Press
on the IRC-6. - This will turn off all the lights until the button is pressed again.
- NOTE: The IRC-6 will not respond to any inputs when Black Out is activated. If the remote does not respond when a button is pressed, try pressing
. - Black Out might have inadvertently been activated.
Master/Slave Mode
- The Master/Slave mode allows a single Intimidator Scan 360 product (the “master”) to control the actions of one or more Intimidator Scan 360 products (the “slaves”) without the need for a DMX controller.
- The master product will be set to operate in either standalone mode or with the IRC-6, while the slave products will be set to operate in slave mode. Once set and connected, the slave products will operate in unison with the master product.
- Configure the products as indicated below.
Slave products:
- Press
- Use
or to select Run Mode. - Press
. - Use
or to select Slave. - Press
. - Connect the DMX input of the first slave product to the DMX output of the master product.
- Connect the DMX input of the subsequent slave products to the DMX output of the previous slave product.
- Finish setting and connecting all the slave products.
Master product:
- Set the master product to operate in standalone mode.
- Make the master product the first product in the DMX daisy chain.
- Configure all the slave products before connecting the master to the daisy chain.
- Never connect a DMX controller to a DMX string configured for Master/Slave operation because the controller may interfere with the signals from the master.
- Do not connect more than 31 slaves to the master.
Maintenance
Product Maintenance
- Dust build-up reduces light output performance and can cause overheating. This can lead to a reduction of the light source’s life and/or mechanical wear.
- To maintain optimum performance and minimize wear, clean all lighting products at least twice a month.
- However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:
- Unplug the product from power.
- Wait until the product is at room temperature.
- Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external surface/vents.
- Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl alcohol.
- Apply the solution directly to a soft, lint-free cotton cloth or a lens-cleaning tissue.
- Softly drag any dirt or grime to the outside of the transparent surface.
- Gently polish the transparent surfaces until they are free of haze and lint.
- Always dry the transparent surfaces carefully after cleaning them.
- Do not spin the cooling fans using compressed air because they could be damaged.
Technical Specifications
Contact Us
General Information Technical Support
- Chauvet World Headquarters
- Address: 3360 Davie Rd. Voice: 844-393-7575
- Davie, FL 33314 Fax: 954-756-8015
- Voice: 954-577-4455 Email: chauvetcs@chauvetlighting.com
- Fax: 954-929-5560
- Toll-Free: 800-762-1084 Website: www.chauvetdj.com
- Chauvet U.K.
- Address: Pod 1 EVO Park Email: UKtech@chauvetlighting.eu
- Little Oak Drive, Sherwood Park
- Nottinghamshire, NG15 0EB Website: www.chauvetdj.eu
- UK
- Voice: +44 (0) 1773 511115
- Fax: +44 (0) 1773 511110
- Chauvet Benelux
- Address: Stokstraat 18 Email: BNLtech@chauvetlighting.eu
- 9770 Kruishoutem
- Belgium Website: www.chauvetdj.eu
- Voice: +32 9 388 93 97
- Chauvet France
- Address: 3, Rue Ampère
- 91380 Chilly-Mazarin
- Email: FRtech@chauvetlighting.fr
- France Website: www.chauvetdj.eu
- Voice: +33 1 78 85 33 59
- Chauvet Germany
- Address: Bruno-Bürgel-Str. 11
- 28759 Bremen
- Email: DEtech@chauvetlighting.de
- Germany Website: www.chauvetdj.eu
- Voice: +49 421 62 60 20
- Chauvet Mexico
- Address: Av. de las Partidas 34 – 3B
- (Entrance by Calle 2)
- Email: servicio@chauvet.com.mx
- Zona Industrial Lerma Website: www.chauvetdj.mx
- Lerma, Edo. de México, CP 52000
- Voice: +52 728-690-2010
Warranty & Returns
- For warranty terms and conditions and return information, please visit our website.
- For customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.
- For customers in the United Kingdom, the Republic of Ireland, Belgium, the Netherlands, Luxembourg,
- France, and Germany: www.chauvetlighting.eu/warranty-registration.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>