FEIT Electric WRAP-4C-840-IR-MM LED Wrap Utility Light with Motion Sensor User Guide
- June 13, 2024
- Feit Electric
Table of Contents
Model: WRAP/4C/840/IR/MM
USE AND CARE GUIDE
4 FTLED WRAP UTILITY LIGHTWITH
MOTION SENSOR AND REMOTE
READ BEFORE INSTALLATION
SAVE THESE INSTRUCTIONS
Questions, problems, missing parts? Before returning to the store, visit
feit.com/help for further assistance
REV024
THANK YOU
We appreciate the trust and confidence you have placed in Feit Electric
through the purchase of this LED utility fixture.
We strive to continually create quality products designed to enhance your
home. Visit us online to see our full line of products available for your home
improvement needs. Thank you for choosing Feit Electric.
Safety Information
For your safety, always remember to:
- Turn off the power supply at the fuse or circuit breaker box before you install the fixture.
- Double-check all connections to be sure they are tight and correct.
- Wear rubber soled shoes and work on a sturdy wooden ladder.
- Account for small parts and destroy packing material, as these may be hazardous to children.
NOTE: This fixture is designed for use in a circuit protected by a fuse
or circuit breaker. It is also designed to be installed in accordance with
local electrical codes. If you are unsure about your wiring, consult a
qualified electrician or local electrical inspector, and check your local
electrical code.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
CAUTION, IMPORTANT SAFTEY INSTRUCTIONS: This portable light-emitting-
diode (LED) luminaire has a polarized plug (One blade is wider than the other)
as a feature to reduce risk of electric shock. This plug will fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician.
Never use with an extension cord unless the plug can be fully inserted. Do not
alter the plug.
Product Specifications
- 120VAC, 60Hz, 55 Watts
- Not Dimmable with Standard Wall Dimmer
- Damp Location
WARNING: RISK OF SHOCK. House electric current can cause painful shock or
serious injury unless handled properly.
CAUTION: Turn off the main power at the circuit breaker before installing
the fixture, in order to prevent possible shock.
NOTICE: All connections must be in accordance with local electrical
standards and the National Electrical Code (N.E.C.) or Canadian Electrical
Code (C.E.C) as appropriate.
Remove the fixture and the mounting package from the box and make sure that no
parts are missing by referencing the illustrations on the installation
instructions.
IMPORTANT: This fixture is intended to be only installed directly beneath
a ceiling mounted receptacle.
Limited Warranty
This product is warrantied to be free from defects in workmanship and
materials for up to 5 years from date of purchase. If the product fails within
the warranty period, please contact Feit Electric at info@feit.com, visit
feit.com/contact-us or call 1-866-326-BULB (2852) for instructions on
replacement or refund.
REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY
APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION
OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY
EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of
incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state or province to province.
Pre-Installation
NOTE: Hardware images are for illustration purposes only. Actual product
size may vary.
TOOLS REQUIRED
PACKAGE CONTENTS
Part | Description | Quantity |
---|---|---|
AA | 6 in. Hanging Chain | 2 |
BB | V-Hook | 2 |
CC | Zip Tie | 3 |
DD | Mounting Screw | 4 |
EE | Wall Anchor | 4 |
FF | Utility Fixture | 1 |
GG | Screw Hook | 2 |
HH | Remote | 1 |
II | Double Sided Tape | |
(For remote mount) | 1 | |
JJ | Screws with Wall Anchors | |
(For remote mount) | 2 | |
KK | Remote Mount | 1 |
LL | 6 in. Hardwire Pigtail | 1 |
MM | Wire Nut | 3 |
NN | C-Channel Bracket | 2 |
OO | 5 ft. Linking Cable | 1 |
PP | 5 ft. Power Cable | 1 |
Mounting Template | 1 | |
RR | Washer | 4 |
SS | Butt Connector | 1 |
PRODUCT DIMENSIONS
WWW.FEIT.COM
Please contact 1-866-326-BULB (2852) for further assistance.
For Hanging Installation
-
Turning off the power
□ Turn the power OFF at the switch, fusebox, or circuit breaker. -
Attaching the screw hooks to a drywall ceiling
□ Mark the location for the wall anchors (EE) using the mounting template (QQ). The spacing between the wall anchors (EE) should be 40 inches.
□ Screw in the screw hooks (GG) into the wall anchors (EE).
□ For wood ceilings, screw in the screw hooks (GG) directly into the wood ceiling. -
Installing the hanging chains to V-hooks
□ Press down firmly on the C-channel brackets (NN) to snap into the groove on the top of the utility fixture (FF). Slide the C-channel brackets (NN) about 40 inches apart.
□ Place the V-hook (BB) through the bottom rung of the hanging chain (AA).
□ Squeeze on the V-hook (BB) and insert it through the center of the C-channel bracket (NN). -
Attaching the hanging chains
□ Hang the hanging chains (AA) onto the screw hooks (GG) and plug in the power cord to the outlet. -
Attaching the zip tie
□ Use the zip tie (CC) to attach the cord to the hanging chain (AA). -
Turning on the power
□Turn the power ON at the switch, fusebox, or the circuit breaker.
□ Turn the fixture ON/OFF using the provided remote. -
Linking multiple fixtures (optional)
Ceiling Flush Mount Plug-In Installation
-
Turning off the power
□ Turn the power OFF at the switch, fusebox, or circuit breaker. -
Attaching the mounting screws and C-channel brackets
□ Position the mounting template (QQ) in the desired fixture location on the ceiling. Tape the four (4) corners of mounting template (QQ) to the ceiling. Mark the location for the mounting screws (DD) using the mounting template (QQ). The spacing between the mounting screws (DD) should be 1.1 inches and 40 inches apart.
□ Use the washers (RR) and mounting screws (DD) to mount the C-channel brackets (NN) to the ceiling. Use included wall anchors if ceiling is drywall or concrete. -
Securing the fixture
□ Lift the utility fixture (FF) up to the to the C-channel brackets (NN). Push firmly until the C-channel brackets (NN) snap into the lenghtwise groove on the top of the utility fixture (FF). Plug in the power cord to the outlet. -
Turning on the power
□Turn the power ON at the switch, fusebox, or the circuit breaker.
□Turn the fixture ON/OFF using the provided remote. -
Linking multiple fixtures (optional)
Hardwire Fixture Installation
-
Turning off the power
Turn the power OFF at the switch, fusebox, or circuit breaker. -
Attaching the mounting screws and C-channel brackets
□ Position the mounting template (QQ) in the desired fixture location on the ceiling. Tape the four (4) corners of mounting template (QQ) to the ceiling. Mark the location for the mounting screws (DD) using the mounting template (QQ). The spacing between the mounting screws (DD) should be 1.1 inches and 40 inches apart.
□ Use the washers (RR) and mounting screws (DD) to mount the C-channel brackets (NN) to the ceiling. Use included wall anchors if ceiling is drywall or concrete. -
Wiring power supply to the fixture
□ Connect supply wires to the 6 inch hardwire pigtail (LL).
Connect the 120V live (black) wire to the black wire.
Connect the neutral (white) wire to the white wire.
Connect the ground wire to the ground wire.
Tuck the wires into the J-box. -
Plugging the pigtail into the fixture
□ Plug the hardwire pigtail (LL) into the socket on top of the fixture (FF). -
Securing the fixture
Lift the utility fixture (FF) up to the to the C-channel brackets (NN). Push firmly until the C-channel brackets (NN) snap into the lenghtwise groove on the top of the utility fixture (FF). -
Linking multiple fixtures (optional)
□Linking multiple fixture flush mounted using a single junction box (optional).
□ Link up to 6 using linking cable (OO) or butt connector (SS).
Using the Wireless Remote
Group Programming
- ** Group Programming
□Program multiple fixtures at once by pressing down and holding a light setting.
□While holding the desired light setting, walk closer towards the fixture until it flashes.
□ The fixture will flash to verify the new setting has been received.
NOTE:** If the fixture did not flash, it did not receive new light setting.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- onsult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly
approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
RF Exposure Information
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body.
ISED Statement
English:This device contains licence-exempt transmitter(s)/receiver(s) that
comply with Innovation, Science and Economic Development Canada’s licence-
exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may
cause undesired operation of the
device.
The digital apparatus complies with Canadian CAN ICES‐3 (B)/NMB‐3(B).
References
- Energy Saving Light Bulbs, Light Fixtures | CFL, LED & More
- Contact Us - Feit Electric
- Energy Saving Light Bulbs, Light Fixtures | CFL, LED & More
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>