TELTONIKA TRB142 Industrial Rugged LTE RS232 Gateway User Guide

June 4, 2024
teltonika

TELTONIKA TRB142 Industrial Rugged LTE RS232 Gateway

OVERVIEW

TELTONIKA-TR-142-Industrial-Rugge-dLTE-RS232-Gateway-
FIG-1

DB9 CONNECTOR PINOUT

  1. Not used.
  2. Received Data (RX) – output.
  3. Transmitted data (TX) – input.
  4. Not used.
  5. Ground (GND).
  6. Not used.
  7. Request data to send (RTS) – input.
  8. Clear data to send (CTS) – output.
  9. Not used.

POWER SOCKET PINOUT

HARDWARE INSTALLATION

  1. Unscrew two back panel hex bolts and remove the back panel.
  2. Insert your SIM card into the SIM socket.
  3. Attach the panel and tighten the hex bolts.
  4. Attach the mobile antenna (max torque 0.4 N·m / 3.5 lbf·in) and connect the USB cable.

DEVICE CONFIGURATION

  1. Power on the device and connect the USB cable to your computer.
  2. Allow the gateway to boot up. This might take up to 30 seconds.
  3. Your computer’s OS should detect the USB device and install the driver.
  4. To enter the gateway’s Web interface (WebUI), type http://192.168.2.1 into the URL field of your Internet browser.
  5. Use login information shown in image A when prompted for authentication.
  6. After logging in pay attention to the Signal Strength indication displayed in the Mobile widget (image B). To maximize the cellular performance try adjusting the antennas or changing the location of your device to achieve the best signal conditions.

TELTONIKA-TR-142-Industrial-Rugge-dLTE-RS232-Gateway-
FIG-5

TECHNICAL INFORMATION

TELTONIKA-TR-142-Industrial-Rugge-dLTE-RS232-Gateway-
FIG-6

  • Order code dependent.
  • Higher gain antenna can be connected to compensate for cable attenuation when a cable is used. The user is responsible for compliance with the legal regulations.

SAFETY INFORMATION

TRB142 gateway must be used in compliance with any and all applicable national and international laws and with any special restrictions regulating the utilization of the communication module in prescribed applications and environments. Hereby, TELTONIKA NETWORKS declares that this TRB142 is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.

Instruction Manual:
Connect the power adapter to turn on the device. Open 192.168.2.1 in your web browser to configure it. More information on https://wiki.teltonika- networks.com/