Fame Audio C05 Condenser Microphone User Manual

June 13, 2024
Fame Audio

Fame Audio logo

C05 Condenser Microphone
User Manual

C05 Condenser Microphone

Important safety instructions!
Please read before connection!

DANGER! (Electrical shock due to high voltages in the device)
The housing must not be removed! There are no parts to be maintained in the device.
Inside the unit there are components which are under high electrical voltage.

Before each use, check the device for damage or the absence of components, protective
devices or housing parts. If this is the case, the device must not be used!
Leave maintenance and repair work to a qualified service workshop or contact your dealer. In the case of a malfunction of the device, operation must also be stopped immediately until the device has been repaired by a specialist!

DANGER! (Electric shock due to short circuit)
Modifications to the power cord or plug are prohibited. If the power cord is damaged, it
must be replaced immediately with an original spare part from the manufacturer.
Always make sure that the grounding of the device is maintained. Only use the supplied power cables and always maintain the earthed protective contacts on the side. Make sure that the sockets used have a properly functioning protective earth.
Failure to do so may result in fire or death due to electric shock!

DANGER! (For babies and children)
Dispose of or store any packaging material properly! Packaging material must be kept out of the reach of babies and children due to the risk of suffocation.
Ensure that children never use the appliance unattended! In addition, make sure that children do not remove (small) parts from the device, as they could suffocate by swallowing parts!

Hint! (Fire hazard due to overheating)
The maximum permissible ambient temperature of this device is 40°C.
Ensure that the unit is placed in a well-ventilated location away from direct heat sources, naked flames, combustible materials, and liquids. A minimum distance of 1 m is required.
Do not tape or cover the ventilation slots of the unit, or insert objects into the unit.

Hint! (Operating conditions)
Due to its structural characteristics, the device is designed for indoor operation (IP20).
Never expose the unit to rain, moisture or liquids as this may cause damage.
Vibrations, dust or sunlight can also cause damage, avoid them!

Hint! (Power supply)
This large diaphragm condenser microphone is operated with phantom power. According to DIN 45596, phantom power is a positive voltage of 12, 24 or 48 volts on both AF lines compared to the cable shielding.
The phantom power usually comes from mixing consoles, sound cards or microphone amplifiers, sometimes also from batteries.
If you do not use your device for a long period of time or carry out maintenance work, disconnect the device from the power source in order to minimize danger. Never pull the cable while phantom power is active!

Hint! (Condensation)
To avoid condensation in the unit, the unit should adapt to the ambient temperature before commissioning.

Hint! (Unwanted odours)
A new product can sometimes lead to unwanted odours. This reaction is normal and disappears after a few minutes.

Hint! (Damage to loudspeaker diaphragms due to feedback)
Avoid feedback by keeping the microphone away from activated speakers that are simultaneously listening to the signal. If necessary, turn off the speakers completely.

Hint! (Sensitive microphone capsule)
To avoid damage to the microphone capsule – never open the microphone basket!

Hint! (Sound pressure level/noise level to noise distance)
Observe the specified sound pressure level/noise level spacing to prevent destruction of the diaphragm caused by extreme levels.

Symbols on device and packaging:

The lightning flash symbol warns the user of uninsulated voltages and the risk of electric shock
The exclamation mark symbol draws the user’s attention to important maintains and operating instructions in the manual
**** The lightning warns you of dangerous voltage accessible from the outside. A connection to any terminal marked with this symbol may only be made with a ready-made cable that complies with the manufacturer’s recommendations or with cables installed by   qualified personnel

Only suitable for indoor use

Read the manual

Please read and follow the warnings and recommendations carefully to ensure safe and trouble-free use.

Congratulations on your new FAME Audio Studio CO5 microphone!
Thank you for choosing a FAME Audio product. Through efficient development and economical production, FAME Audio enables high quality products at a fantastic price.

Please read the instruction manual carefully to learn about all the features of this product and keep it for future use.
Have fun with your new product!

Your FAME Audio Team

Guarantee:

The current general terms and guarantee conditions of the Music Store professional GmbH apply.

You can view it at: www.musicstore.de

If you have any questions or suggestions, please contact us:

Music Store professional GmbH
Istanbulstr. 22-26
51103 Cologne
Managing Director: Michael Sauer
WEEE-Reg.-No. DE 41617453

Tel: +49 221 8884-0
Fax: +49 221 8884-2500
info@musicstore.de

Intended use:

The product FAME Audio Studio CO5 was designed for use as a microphone. The device may only be used for this purpose and in accordance with the operating instructions. Other purposes as well as operation under other operating conditions are expressly not  intended and can lead to damage to property or personal injury! No liability is assumed for damage resulting from improper use.

It must be ensured that the device is operated exclusively by trained and competent users who are in full possession of their mental, physical and sensory abilities. The use of other persons is expressly only permitted at the request of a person responsible for their  safety, who instructs or supervises the use.

Scope of delivery:

Content Quantity
FAME Audio Studio CO5 1
Elastic mounting 1
Case 1
Manual 1

Installation:

Be sure to check the unit for damage before use. Use the original packaging or a suitable transport or storage packaging to protect the product from dust, moisture, etc. when not in use.

Equipment and use:

This large diaphragm condenser microphone has a three-pin XLR connector and comes with a matching bracket. Due to its characteristics, the FAME Audio Studio C05 is used for miking vocals, speech, guitar and percussion.

Commissioning:

All connections of the device should be made before switching on. Only use high-quality, undamaged and as short cables as possible for the connections.

Configuration of the 3-pin XLR connector:

Fame Audio C05 Condenser Microphone - KLR connector

Directional characteristics:

Microphones have one or more directional characteristics in order to achieve better sound recording results, depending on the application. Sound arriving at the basket and capsule from certain angles can be erased, attenuated or not influenced at all. How  strong or weak these effects are depends on the microphone. The main characteristics are omnidirectional, eight and club, while the cardioid, wide cardioid, supercardioid and hypercardioid characteristics are mixed.
Example application 1: Omnidirectional
Since the omnidirectional characteristic has no extinctions due to the design of the microphone, sound from all directions can be picked up almost uniformly.
Example application 2: Cardioid
Sound hitting the rear is extinguished/dampened by the cardioid characteristic. The focus here is on the direct signal.

FAME Audio Studio CO5 – Cardioid characteristic:

The FAME Audio C05 features a cardioid characteristic that effectively cancels or attenuates sound coming from the rear (at 180° or below). This microphone is ideal for recording vocals, speech, guitar and percussion.

(Drawing is for general illustration only and may vary by microphone)

Specifications:

Model Studio CO5
Sound conversion principle FET Condenser Microphone
Membrane size 1 inch large diaphragm, gold plated
Directional characteristic Cardioid
Frequency range 20 Hz – 20 kHz
Field transmission factor 12 mV/Pa (at 1 kHz)
Output impedance 250 Ohm
Equivalent noise level 22 dB (A-weighted)
Sound pressure level limit for K <0.5% 125 dB
Signal-to-noise ratio 79 dB
Power supply Phantom power +48 V
Connection XLR 3 pin

Troubleshooting:

The following overview serves as an aid for quick troubleshooting. If you are unsure, contact the manufacturer, the dealer or the corresponding specialist personnel.

Symptom Troubleshooting
No tone Check the cable for damage (cuts, extreme kinks, etc.) and replace

if necessary.
Check the wiring. Connectors must be fully inserted and snap into  place!
Check if the 48V phantom power is switched on at the  console/interface.
Check the setting of the preamplifier on the console/interface/etc.
Delayed tone| Change the buffer size in the DAW settings. The lower the number,  the lower the latency. (Note: with a low buffer size, the machine requires higher performance. Depending on the computer, this can  lead to higher performance losses).  For more information, please  refer to the manual of each digital audio workstation.

If the specified corrections have not led to success, please contact our service staff. The contact details can be found at www.musicstore.de

Cleaning:

Regular cleaning of the device from dirt and dust increases the shelf life of the product. Always disconnect the device from the power supply before cleaning it! Never clean the appliance wet! A dry microfibre cloth is best.
Ventilation grilles and openings should always be cleaned of dust and dirt. Suitable compressed air sprays are recommended for this application.

Envrionmental protection:

The company MUSIC STORE professional GmbH always strives to reduce the burden of packaging to a minimum. The use of environmentally friendly and recyclable materials is of fundamental importance to us. Please dispose of and recycle the packaging  components after use properly.

Disposal of packaging:
Ensure that paper packaging, plastic materials, etc. are separately recycled. Observe the corresponding disposal instructions on the packaging.
Disposal of batteries:
Batteries do not belong in the garbage! Please keep batteries in accordance with the official collection points or disposal stations in accordance with the specifications.
Disposal of your old device:
Do not dispose of the device with household waste! This device is subject to the WEEE Directive (Waste Electrical and Electronic Equipment) in its currently valid version.

The device will be disposed of by an approved waste disposal company or your local waste disposal office. The regulations valid in your country must be observed!

Manufacturer: MUSIC STORE professional GmbH,
Istanbulstraße 22-26,
51103 Cologne, Germany

Notes____

Fame Audio logo
MS ID:
REC0008047-000
02/2023

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals