HUBBELL LP015039026T Unheated Insulated Enclosure Instructions

June 13, 2024
Hubbell

HUBBELL LP015039026T Unheated Insulated Enclosure

Product Information

The Hot Box Enclosures are designed to provide reliable protection for various devices and equipment in outdoor environments. With a wide range of enclosures available, Hot Box offers versatility, quality, and performance in their products. The enclosures are constructed using different materials such as aluminum, fiberglass, and HDPE (Plastic) PEZ, each with its own unique features and benefits.

Aluminum Enclosures
The aluminum enclosures are manufactured from corrosion and UV resistant stucco embossed aluminum. They feature a durable, industrial-style riveted construction, with the option of Mill Finish and Marine Grade aluminum. These enclosures are commonly used for larger projects and can be easily customized. The bonded foam insulation ensures long-lasting durability and prevents sagging or delamination from the walls.

Fiberglass Enclosures
Reinforced fiberglass enclosures have revolutionized the Hot Box industry by reducing installation time and cost. These lightweight enclosures are available in different models to protect backflow, pump, air release valve, or any other equipment that needs protection from the elements. Fiberglass enclosures are easy to install, often requiring only one person, which helps reduce labor costs.

HDPE (Plastic) PEZ Enclosures
Polyethylene (HDPE) enclosures are designed to efficiently protect up to two devices. These enclosures are commonly specified by irrigation suppliers and landscape architects. Available in green or beige, the PEZ enclosures combine easily recycled materials with a lightweight and cost-effective design. They offer an attractive look and long-lasting durability.

Hot Rok and PolyRok
Hot Rok and PolyRok are camouflaging enclosures used by irrigation contractors and landscape architects to blend in with the natural environment. These enclosures provide both protection and aesthetic appeal.

ASSE Performance Requirements
The Hot Box enclosures meet or exceed the test provisions of the ASSE 1060 standard, which ensures their performance and quality. Hot Box enclosures undergo various independent material and product performance tests to achieve ASSE 1060 certification. The enclosures are tested for air inlet, structural integrity, access for testing and maintenance, hinged access panel restraints, drainage performance, freeze protection capability, and security/locking mechanism.

ASSE Standard 1060 Classes
Hot Box offers ASSE certified enclosures that meet different class requirements. When specifying or installing a Hot Box enclosure, engineers, architects, and contractors can have confidence in the safety and quality of the enclosure, bringing peace of mind and integrity to the entire project.

Product Usage Instructions

  1. Determine the type of enclosure required for your specific application – aluminum, fiberglass, or HDPE (Plastic) PEZ.
  2. Select the appropriate size and style of the enclosure based on your project requirements.
  3. Prepare the installation site by ensuring a level and stable surface.
  4. For aluminum enclosures, customize the enclosure if necessary before installation.
  5. Position the enclosure at the desired location, ensuring it is securely placed.
  6. Follow the manufacturer’s guidelines for connecting devices or equipment to the enclosure.
  7. For fiberglass enclosures, one person can typically install the enclosure easily. Follow the manufacturer’s instructions for proper installation.
  8. For HDPE (Plastic) PEZ enclosures, ensure they are aligned properly and securely in place. When installing Hot Rok or PolyRok enclosures, position them in a way that blends with the natural environment.
  9. Regularly inspect the enclosure to ensure it remains in good condition and provides adequate protection.
  10. Follow any additional maintenance or care instructions provided by the manufacturer for optimal performance and longevity.

HOTBOX®

ENCLOSURES

THE ENGINEERED ENCLOSURE

HOTBOX® ENCLOSURES
Hot Box® Enclosures have been trusted since 1986, and requested by name. Leading the industry with innovative designs, Hot Box enclosures are built to speed the installation and maintenance of backflow prevention, pump and sprinkler assemblies, pressure vacuum breakers, and air release valves. These enclosures facilitate an installation in the most economical, safe, and accessible location – outside and above ground. More and more designers, utilities, and contractors are putting the backflow preventer at the curb to eliminate costly problems encountered in equipment rooms. Features such as heater sizing, drain-sizing, service access, and rigid construction make Hot Box enclosures the ultimate solution for protecting outdoor infrastructure and piping systems.
2 Hubbell Utility Solutions

hubbellpowersystems.com

Hot Box® Enclosures
Hot Box offers the broadest range of enclosures in the industry with multiple material types, styles, and sizes. All are built with the same attention to quality and performance that you know and expect from Hot Box. Our comprehensive product offering is designed to ensure that your application requirements are met, and your expectations are exceeded.

Aluminum Enclosures
Manufactured from corrosion and UV resistant stucco embossed aluminum, these enclosures have a highly durable, industrial style, riveted construction (optional Mill Finish and Marine Grade aluminum available). Commonly used for larger projects due to its ability to be easily customized, aluminum provides both versatility and strength. Bonded foam insulation will not sag or delaminate from the walls, unlike glued or tacked board insulation.

Fiberglass Enclosures
Reinforced fiberglass revolutionized the Hot Box industry by reducing both installation time and cost. With different fiberglass models to protect your backflow, pump, air release valve, or anything that needs to be protected from the elements, fiberglass is often chosen due to its lightweight nature. For applications, typically one person can easily install a Hot Box on their project, thus reducing your labor costs.

HDPE (Plastic) PEZ Enclosures
Polyethylene enclosures can efficiently provide protection for up to a 2″ device. Commonly specified by irrigation suppliers and landscape architects, the PEZ enclosures are available in green or beige. Combining easily recycled materials with a lightweight, cost effective design, our PEZ product line has both an attractive look and the long lasting durability the industry expects.
Fiberglass Hot Rok® & Plastic PolyRok® Enclosures
Hot Rok and PolyRok are camouflaging enclosures. They are commonly used by irrigation contractors and landscape architects to blend in with the natural environment.
4 Hubbell Utility Solutions

Overview/ASSE-Performance Requirements

ASSE Performance Requirements
ASSE Standard 1060
In 1996, The American Society of Sanitary Engineering (ASSE) developed the ASSE 1060 industry standard for outdoor enclosures to cover fluid conveying components. Born from the organization’s philosophy of “prevention rather than cure,” the ASSE 1060 seeks to protect public health and safety by providing performance requirements to safeguard equipment from freezing, tampering, and vandalism. As a result, the ASSE 1060 standard has been adopted by utilities and Water Authority departments across the nation. To this day, the ASSE 1060 remains the water industry’s gold standard.
Hot Box® ASSE 1060 Certified
All Hot Box standard enclosures meet or exceed the test provisions of the ASSE 1060 standard and proudly bear the ASSE 1060 seal. To achieve the certification, Hot Box enclosures must pass numerous independent material and product performance tests. Laboratory Test Requirements for ASSE 1060 2006:
Section 3.1 Air Inlet Test (Class I-V, II-V and II-V)
Section 3.2 Structural Test (All Classes)
Section 3.3 Access for Testing and Maintenance (All Classes)
Section 3.4 Hinged Access Panel Restraints Test
Section 3.5 Drainage Performance Test (All Classes)
Section 3.6 Freeze Protection Capability Test (Class I and I-V)
Section 3.7 Security/Locking Mechanism Test
ASSE Standard 1060 Classes-Which One Do You Need?
Class I – Freeze Protection Enclosures (Heated): Designed and constructed to maintain a minimum internal temperature of 40°F with external temperatures as low as -30°F. Class II – Freeze Retardant Enclosures (Insulated Non-Heated): Designed and constructed to be installed in locations with minimum external temperatures of 33°F. Class III – Non-Freeze Protection Enclosures (Uninsulated Non-Heated): Designed and constructed to provide system security for components when freezing temperatures are not a consideration.
Hot Box®- Reduced Liability…Increased Credibility
Hot Box is the #1 trusted outdoor protection enclosure manufacturer in the industry. Our enclosures undergo rigorous physical, environmental, and internal equipment testing. When an engineer, architect, or contractor specifies or installs an ASSE certified Hot Box enclosure, they know the safety and quality of the enclosure will bring peace of mind and integrity to the entire project.

Look for the Seal

to Know it’s Real!
hubbellpowersystems.com 5

ASSE Performance Requirements
6 Hubbell Utility Solutions

Code & Specification Requirements
The following are samples of building codes and manufacturer’s specifications that demonstrate the need for an enclosure to protect infrastructure from freezing temperatures:

Code and Specification Requirements

ASSE STANDARD #1060 Outdoor Enclosures for Fluid Conveying Components
Section 3.2.1: Enclosure is capable of supporting a minimum vertical load of 100 lb./sf.
Section 3.3.1: Enclosure has been designed to be accessed and provide sufficient room for monitoring, testing, maintenance, repair or replacement of the component located inside the enclosure.
Section 3.5.1: Depth of water within the enclosure does not exceed 8 inches during full flow of the backflow prevention assembly relief discharge, and that the depth of the water does not exceed 1/4″ after full flow has ceased.
Section 3.6.1: Enclosures shall contain a heat source capable of maintaining the temperature of the component and associated piping at 40°F (4.4°C) inside the enclosure when subjected to -30°F (-34.4°C ) outside air temperature.
AMERICAN SOCIETY OF PLUMBING ENGINEERS-ASPE
Data Book:
Reduced pressure principle devices, double check valves and vacuum breakers installed in regions subject to freezing must be protected by the insulation of the units in above-ground, heated structures.
INTERNATIONAL PLUMBING CODE® 2015
Section 608.14.1: Outdoor enclosures for backflow prevention devices shall comply with ASSE 1060.
AWWA M-14
A reduced pressure backflow assembly must be protected from freezing temperatures, and a double check (backflow) valve assembly must be protected from freezing temperatures.
FEBCO
The backflow prevention assembly must be protected from freezing.
WATTS
In an area where freezing conditions can occur, the backflow prevention assembly should be installed in a properly insulated utility building or shelter.

NFPA 13
8.16.4.1.3: Where aboveground waterfilled supply pipes, risers, system risers, or feed mains pass through open areas, cold rooms, passageways, or other areas exposed to temperatures below 40°F (4°C), the pipe shall be permitted to be protected against freezing by insulated coverings, frost proof casings, or other means capable of maintaining a minimum temperature between 40-120°F (4-49°C).
PLUMBING-HEATING-COOLING CONTRACTORS ASSOCIATION (PHCC) National Standard Plumbing Code
Freezing: The plumbing system shall be protected from freezing or overheating. The following conditions shall be met:
In areas with seasonal freezing temperatures, all waste, vent and water supply piping in exterior walls and other areas shall be protected from freezing.
THE COUNCIL OF AMERICAN BUILDING OFFICIALS (C.A.B.O.) One and Two Family Dwelling Code
Freezing: Water, soil, or waste pipe shall not be installed or permitted outside of a building or in an exterior wall unless adequate provision is made to protect such pipe from freezing where necessary.
THE SOUTHERN BUILDING CODE CONGRESS International (S.B.C.C.I) Standard Plumbing Code
Freezing: A water, soil, or waste pipe shall not be installed or permitted outside of a building or concealed in outside walls or on any place where they may be subject to freezing temperature, unless adequate provision is made to protect them from freezing.
THE BUILDING OFFICIALS & CODE ADMINISTRATORS International, In. (B.O.A.C.) National Plumbing Code
In climates with freezing temperatures, plumbing piping in exterior walls or areas subject to freezing temperatures shall be protected against freezing by insulation or heat or both.
NATIONAL BUILDING CODE OF CANADA
Where piping may be exposed to freezing conditions it shall be protected from frost.
hubbellpowersystems.com 7

Enclosure Selection
With hundreds of Hot Box® Enclosures available, you may be asking yourself, which enclosure should I choose? Below is a guide to help you choose from our many different options:
HOT BOX® SELECT SIX (See pages 12-13)
Select enclosures designed to accommodate common standard and N-pattern pipe sizes up to 10″ diameter: Six nominal sizes accommodate standard and N-pattern pipe sizes from 2 ½” to 10″ dia. Reduced lead times. Protects against freezing conditions with optional, wall-mounted heaters that offer better
performance and safety with the heater raised above the discharge point. Available in Stucco, Mill Finish or Federal Brown aluminum.
STANDARD SIZE ENCLOSURES (See pages 14-21 & 26-44)
Hot Box® has a wide variety of standard enclosure sizes available in different styles and material types to meet your needs: Better fit with standard sizes ranging from 6″W x 20″L x 22″H to 87″W x 172″L x 85″H. Dura Fold® and Designer SeriesTM Enclosures are the industry benchmarks. These models
provide both ease of installation and accessibility. Other traditional enclosure styles include: flip-top fiberglass, sectional aluminum, and
drop over. Material types: aluminum, fiberglass, and high density polyethylene (HDPE) . Various options, such as vents, fans, lights, and alarms are available to modify any standard
enclosure. See pages 45-49 for details.
CUSTOM SIZE ENCLOSURES (See pages 22-25)
Hot Box® offers custom sized sectional and Dura Fold® aluminum enclosures which can be manufactured to an engineer’s exact specifications depending on the application:
Best fit with dimensions manufactured to engineer’s specifications . Peace of mind with ASSE 1060 certified enclosures up to 172″L x 87″W x 85″H
(larger enclosures built with same design and quality). Special configurations, like wall-mounted enclosures, available upon request. Various material thicknesses available depending on specification requirements. Various options, such as vents, fans, lights, and alarms are available to modify any custom
sized enclosure. See pages 46-50 for details.
8 Hubbell Utility Solutions

Hot Box® Select-A-Box Tool
Selecting a standard Hot Box® enclosure for your application is easy. Our Select-A-Box tool quickly shows all available styles of Hot Box® enclosures to fit your specific backflow device. Once you select the style of enclosure desired, the tool will provide a drawing, piping layout diagram, specification, and installation instructions.

1

4

5

3

Step # 1

Select your manufacturer, model, valve type

and clearance requirement from the drop-down

2

menus provided1, then hit next2.

Notes: 1) Helpful notes3 2) You can hit reset4 at any time to start over. 3) If you hit “Submit” early, then it will indicate which “Required”5 piece of information is missing.

Enclosure Selection

1

1

2

2

3

1

Step # 2
The Select-A-Box tool will display all available styles of Hot Box®. Please click on the heated or unheated part# of your preferred style to proceed1. Your project specifications are viewable below the table for verification2. If you need to make changes, then simply select the “Previous” button3.
3
Step # 3
4
The Product Results page with Piping Layout1 will be displayed. Click on the available PDF’s for drawings2, specifications3, or installation instructions4.
Visit www.hpsapps.com/hotbox/ or scan the QR code to select a Hot Box® Enclosure today.
hubbellpowersystems.com 9

Enclosure Selection-By Pipe Size
If you only know your pipe size because the valve manufacturer and type has yet to be determined, the chart below can help you select a Hot Box® Enclosure. Please note that the Hot Box Select-A-Box tool can potentially provide a better fit, and one of the Hot Box Select Six can cover a wider range of pipe sizes and valves types.

Pipe Size 0.75″-1″ 1.25″-2″
Pipe Size 2.5″-3″
4″ 6″ 8″ 10″

Material Fiberglass Aluminum
Plastic Fiberglass Aluminum
Plastic Material Fiberglass
Aluminum
Fiberglass
Aluminum
Fiberglass Aluminum Fiberglass Aluminum
Aluminum

Backflow Preventer (Straight) Sizing Guide by Pipe Size

Standard HotBox Enclosure 12″ Bottom Clearance

Quarter Turn

HF013027023, HE014027026

HD013027023, HJ013026023

HP010026023G, HP010026023T

HF013039028, HJ013038026

HD013039028, HJ015047028

HP015039026G, HP015039026T

NRS

OS&Y

HF026070045, HF026070045, HE026070045 HE026070045

HD026070045, HA026070055, HK026070045

HD026070045, HA026070055, HK026070045

HF029083062 HF029083062

HD032090050, HA032090050, HK036088055

HD032090057, HA032090057, HK036088055

HF036100075 HF036100075

HA036105053 HK036100064

HA036105053 HK036100064

HF036115075

HF036115075

HA040118058 HK038118080

HA040118074 HK038118080

HA042142065 HK038142080

HA042142085 HK038142080

Standard HotBox Enclosure 18″ Bottom Clearance

Quarter Turn

HF013027035

HD013027035

N/A

HF013039036

HD013039036

N/A

NRS

OS&Y

HF026070045, HE026070045 HF026070055

HD026070045, HA026070055, HK026070045

HD026070055, HA026070055, HK036088055

HF029083062 HF029083062

HD032090050, HA032090050, HK036088055

HD032090057, HA032090057, HK036088055

HF036100075 HF036100075

HA036105053 HA036105064 HK036100064 HK036100064

HF036115075 HF036115075

HA040118058 HK038118080

HA040118074 HK038118080

HA042142085 HK038142080

HA042142085 HK038142080

Standard HotBox Enclosure 30″ Centerline

Quarter Turn

HF013027035

HD013027035

N/A

HF013039036

HD013039036

N/A

NRS

OS&Y

HF026070045, HE026070045

HF026070055

HD026070045, HA026070055, HK026070045

HD026070055, HA026070055, HK036088055

HF029083062

HF029083062

HD032090057, HA032090057, HK036088055

HD032090057, HA032090057, HK036088055

HF036100075

HF036100075

HA036105053 HK036100064

HA036105064 HK036100064

HF036115075

HF036115075

HA040118058 HK038118080

HA040118074 HK038118080

HA042142085 HK038142080

HA042142085 HK038142080

Pipe Size 2.5″-3″
4″
6″ 8″ 10″

Material Fiberglass Aluminum Fiberglass
Aluminum
Fiberglass Aluminum Aluminum
10″ Aluminum

Backflow Preventer (Straight) Sizing Guide by Pipe Size

Standard HotBox Enclosure 12″ Bottom Clearance

Standard HotBox Enclosure 18″ Bottom Clearance

Standard HotBox Enclosure 30″ Centerline

NRS

OS&Y

NRS

OS&Y

NRS

OS&Y

HM041041045,

HM041041045,

HM041041045,

HM041041045,

N/A

N/A

HL035045035 HF044046050 HF044046050 HF044046050

HD041041045

HD041041045

HD041041045

HD041041045

N/A

N/A

HM041041045,

HM041041045,

HM047047049, HM047047049,

HF044046050 HF044046050 HF044046050 HF044046050

N/A

N/A

HD041041045

HD041041045

HD047047049, HA047047049

HD047047049, HA047047049

N/A

N/A

HM053053056, HM053053056, “HM053053056, HM053053056,

N/A

N/A

HF060060060 HF060060060 HF060060060 HF060060060

HD053053056

HD053053056

HD053053056

HD053053056

N/A

N/A

HA045072060 HA065072060

HA051096067

HA051096067

N/A

N/A

Aluminum

HA045082062

HA071105064

HA071105064 HA071105064

N/A

HA042142065 HK038142080

HA042142085 HK038142080

HA042142085 HK038142080

HA042142085 HK038142080

HA042142085 HA042142085 HK038142080 HK038142080

Part numbering system:

Prefix Definition: (digits 1 & 2) HA Heated Sectional Aluminum HD Heated Durafold Aluminum HK Heated Aluminum Modular HJ Heated Aluminum Drop Over

HE Heated Fiberglass Drop Over HF Heated Fiberglass Flip-top HM Heated Designer Series Fiberglass HP Heated HDPE Drop Over LA Unheated Sectional Aluminum

Prefix x Width x Length x Height

LD Unheated Durafold Aluminum LK Unheated Aluminum Modular LJ Unheated Aluminum Drop Over LE Unheated Fiberglass Drop Over LF Unheated Fiberglass Flip-top

LM Unheated Designer Series Fiberglass
LP Unheated HDPE Drop Over

Note: The enclosure recommendations above will work for most of the backflow devices for each pipe size. Sizing verification is ultimately the responsibility of the customer. Customers are also responsible for verifying the clearances meet all local code requirements.

10 Hubbell Utility Solutions

Enclosure Selection-Manual Sizing

HOW TO SIZE A HOT BOX ENCLOSURE
i——-Enclosure Length——
—- —- —- —- —,–+-WC

Enclosure

BW

Width

WC —¥—– —- —- —- —·-+–

EL——-BL—–i–EL

Enclosure Selection

BTH

+-
CH
l_,

Formulas:

4X I
4 1/2-J

BW WC + WC

Backflow Width Width Clearance Width Clearance

=Enclosure Width

BL Backflow Length
EL Elbow Length
EL Elbow Length
LC Leng th Clearance
+ =LCL=eng'”””th_Cl=ea=rance
=Enclosure Length

BH Backflow Height

BTH

BC HC

Backflow Clearance Height Clearance

OR

CH HC

=Enclosure Height

w/ bottom clearance

Backflow Top Height Centerline Height Height Clearance =Enclosure Height
w/ centerline

Enclosure Height

Size

Elbow Leng th

Elbow Style

0.50 0.75 1.00 1.50 2.00 2.50 3.00 4.00 6.00 8.00 10.00 12.00

3.25 3.75 4.06 5.13 5.75 8.50 9.25 11.00 13.50 15.75 19.00 21.50

Thre ad ed Thre ad ed Thre ad ed Thre ad ed Thre ad ed Flang ed Flang ed Flang ed Flang ed Flang ed Flang ed Flang ed

The elbow length on threaded elbows include a 2″ pipe nipple for ease of attachment.

See the backflow manufacturers website for the backflow dimensions.
Hot Box suggests a minimum 3″ clearance (each side) for 2″ pipe and smaller and 6″ clearance (each side) for 2 1/2″ pipe and larger. These clearances can be adjusted to better fit a particular Hot Box enclosure.

hubbellpowersystems.com 11

Hot Box® Select Six
SPECS MADE SIMPLE
Hot Box® Select Six Enclosures are six enclosure sizes designed to accommodate standard and N-pattern pipe sizes from 2 ½” to 10″ diameter. Reduced Lead Times – A few enclosure sizes fit a variety of backflows. Durable and strong – The aluminum enclosure is corrosion and UV resistant. Fast Access – Dura Fold® design allows fast access via hinged and removable sections. Reliable Insulation – will not sag or delaminate from the walls dues to its strong chemical
bond to the aluminum. Safe Freeze Protection – Wall-mounted heaters above the discharge point provide better
performance and safety. Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength,
drainage capacity, material construction, equipment access, and functional design are met. Finish Options – Stucco embossed aluminum is standard. See page 51 for additional colors
and finishing options.
12 Hubbell Utility Solutions

Hot Box® Select Six

Hot Box® – Dura Fold®

Backflow Type
Standard Standard N-Pattern N-Pattern

Inside Dimensions (inches)

Pipe Dia. Width Length Height

2 ½” – 3″ 26

70

45

4″ – 6″

32

90

57

2 ½” – 4″ 38

38

45

6″ – 8″

53

53

53

Weight (lbs) 144 201 109 185

Pad Size (in)
38 X 82 44 X 102 50 X 50 65 X 65

N-Pattern

10″

62

68

58

248

74 X 80

For unheated units, replace the “H” in the part# with an “L”.

Heater(s)
(1) 1000W (1) 2000W (1) 1000W (1) 1500W (1) 1000W (1) 1500W

Part Number
HD026070045 HD032090057 HD038038045 HD053053053
HD062068058

Hot Box® Select Six

Hot Box® Sectional

Inside Dimensions (inches)

Backflow Type
Standard

Pipe Dia.
8″ – 10″

Width 36

Length 118

Height 80

Weight (lbs)
333

For unheated units, replace the “H” in the part# with an “L”.

Pad Size (in)
48 X 130

Heater (s) (2) 1500W

Part Number HA036118080

hubbellpowersystems.com 13

Hot Box® Aluminum Enclosures
Aluminum Hot Box® Enclosures are crafted from industrial stucco embossed aluminum (smooth mill finish optional). Aluminum is highly durable, and has a riveted construction for added strength. Commonly used for larger projects due to easy customization, aluminum provides both versatility and strength. You can be confident that your insulation will provide the premium level of freeze protection needed in the field. Optional wall-mounted heaters provide the safest and most effective prevention against freezing conditions. All standard models are ASSE 1060 certified, so you can specify and install a product that has been tested by 3rd party engineers. Benefits include: Superior Strength – Riveted construction provides superior strength and durability. Reliable Insulation – Whether spray up foam or boardstock. Wall-Mounted Heaters – Ensures economical performance and safety by keeping the heater
off the ground and above discharge point. Customizable Options – Built to fit your needs. Custom sizes and components such as vents,
fans, and alarms are available.
14 Hubbell Utility Solutions

Aluminum Enclosures

Hot Box® Aluminum Enclosures
Hot Box® offers the broadest range of aluminum enclosures in the industry with many different styles and standard sizes. All are built with the same attention to quality and performance that you know and expect from a Hot Box Enclosure. Our comprehensive product offering is designed to ensure that your application requirements are met, and your expectations are exceeded.
Dura Fold® Enclosures
Save time and money with quick installation and easy access via hinged access panels and a hinged lid for future testing and maintenance. Dura Fold Enclosures also include all the inherent benefits of our aluminum enclosures, like corrosion and UV resistance, bonded foam insulation, and wall mounted heaters.
Modular Enclosures
Needing a unit on the go? Hot Box Modular features prepackaged components and accessories for on the job assembly. This flat pack design makes for a quick and easy installation while utilizing a smaller shipping and storage footprint compared to pre-assembled units.
Single Aluminum Enclosures
Save time and money during installation with either a lightweight drop over or by connecting multi-sections for assembly of your Hot Box.
Dual Aluminum Enclosures
Wider design to accommodate dual and tandem installations, with all the same benefits of our sectional aluminum enclosures.
Custom Aluminum Enclosures
Innovative custom enclosures by Hot Box are built to fit your specific project. If your project requires pumps, meter bypasses, FDC hookup, custom sizing or custom colors, Hot Box has a full staff of design engineers ready to assist.
hubbellpowersystems.com 15

Dura Fold® Aluminum Enclosures

Dura Fold® Enclosures feature an innovative design that helps you save time and money. Unique design features facilitate quick installation and easy access for future testing and maintenance. Key benefits include:

Quick Installation & Easy Access – Dura Fold® Enclosures ship assembled to allow quick installation. The design includes hinged walls, as well as front and top lids, to provide easy access. Also the front wall is easily removed to provide unobstructed access for equipment testing and maintenance after installation.

Corrosion & Scratch Resistant – Stucco embossed aluminum sheeting provides a corrosion proof and scratch resistant finish that looks good and stands up to the elements.

Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.

Superior Protection – Insulation will not sag or delaminate from the walls due to the strong chemical bond between the aluminum and the insulation. Heaters and/or heat trace tape can provide proven freeze protection.

Bottom-line, when time and money matter, install a Dura Fold® Enclosure every time!

For unheated units, replace the “H” in the part# with an “L”. Pad size=inside Dimensions + 12″.

Catalog Part Number
HD011019022 HD013027023 HD013027035 HD013039028 HD013039036 HD013047028 HD013047036 HD021033024 HD022060030 HD022060042 HD024039032 HD025053032 HD026070045 HD026070055 HD026083045 HD026083055 HD029060037 HD032037035 HD032090050 HD032090057 HD033053044 HD037043040 HD041041045 HD042052044 HD043053036 HD047047049 HD048063050 HD053053056 HD053062042 HD054062056

Model Number
DF.75H DF1H DF1TH DF2H DF2TH DF2SH DF2STH DF1.5H DF2.5H DF2.75H DF2000H DF2100H DF3NH DF3EH DF3NSH DF3ESH DF3000H DFS4FOH DF4NH DF4EH DF4000H DFS6FOH DF4FEH DFS8FOH DF2200H DF6FEH DFS10FOH DF8FEH DF3100H DF10FEH

Inside Width (in)
11 13 13 13 13 13 13 21 22 22 24 25 26 26 26 26 29 32 32 32 33 37 41 42 43 47 48 53 53 54

Inside Length (in)
19 27 27 39 39 47 47 33 60 60 39 53 70 70 83 83 60 37 90 90 53 43 41 52 53 47 63 53 62 62

Inside Height (in)
22 23 50.5 57.5 50.5 57.5 36 24 30 42 32 32 45 55 45 55 37 35 50.5 57.5 44 40 45 44 36 49 50.5 56 42 56

Heater(s)
30W 60W 60W 90W 90W 90W 90W 60W (2)-90W (2)-90W 90W 1000W 1000W 1500W 1500W 1500W 1000W 1000W 1900W 1900W 1000W 1000W 1000W 1500W 1000W 1500W 1900W 1500W 1500W 1900W

Weight #
27 35 44 48 56 54 64 46 78 96 65 77 118 135 133 154 85 93 163 201 107 108 104 138 127 128 175 179 164 194

16 Hubbell Utility Solutions

DURA FOLD® Aluminum Enclosures

Dura Fold® Aluminum Enclosures
hubbellpowersystems.com 17

Modular Enclosures
Quick & Easy Installation – Hot Box Modular features prepackaged components and accessories for easy on the job assembly.
Easy Access – Lightweight, insulated panels and roof make for quick and easy assembly in the field.
Peace of Mind – All components meet the necessary requirements set forth by ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access and functional design are met.
Superior Freeze Protection – Wall mounted heaters provide better long term performance when compared to slab mounts.
Finish Options – Stucco embossed finish allows for longer lasting visual appeal hiding any imperfections as a result of the elements.

For unheated units, replace the “H” in the part# with an “L”. Pad size=inside Dimensions + 12″.

Catalog Part Number
HK026070045

Model Number HBM3E

Pipe Size

Inside Width (in)

Inside Length (in)

Inside Height (in)

2.5 – 3″

26

70

45

Heaters (1) 1500W

Doors Weight #

2

110

HK036088055

HBM4E

4″

36

88

55

(1) 1900W

2

163

HK036100055

HBM6N

6″

36

100

55

(1) 1900W

2

177

HK036100064

HBM6E

6″

36

100

64

(2) 1500W

2

210

HK038118080

HBM8E

8″

38

118

80

(2) 1500W

4

280

HK038142080 HBM10E

10″

38

142

80

(2) 1500W

4

319

LK026070045

LBM3E

2.5 – 3″

26

70

45

Unheated

2

98

LK036088055

LBM4E

4″

36

88

55

Unheated

2

151

LK036100055

LBM6N

6″

36

100

55

Unheated

2

165

LK036100064

LBM6E

6″

36

100

64

Unheated

2

186

LK038118080

LBM8E

8″

38

118

80

Unheated

4

256

LK038142080

LBM10E

10″

38

142

80

Unheated

4

295

For unheated units, replace the “H” in the part# with an “L”. Pad size=inside Dimensions + 12″.

18 Hubbell Utility Solutions

Modular Enclosures
hubbellpowersystems.com 19

Modular Aluminum Enclosures

Single Aluminum
Quick & Easy Installation – Modular design with a maximum of 4 tongue and groove sections.
Easy Access – Lightweight removable doors can easily be removed by one person (sizes 3″ and up).
Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.
Superior Freeze Protection – Depending on the size, quality boardstock or foam insulation protect equipment from freezing. Where applicable wall-mounted heaters are installed above the discharge point to provide better long-term performance and safety.
Finish Options – Stucco embossed aluminum is standard. Also available in a smooth mill finish aluminum or optional colors (see page 51 for details).

Catalog Part Model

Inside

Inside

Inside

Number

Number Width (in) Length (in) Height (in)

HA026070055 HB3E-AL

26

70

55

HA026083055 HB3ES-AL

26

83

55

HA032090050

HB4N

32

90

50.5

HA032090057

HB4E

32

90

57.5

HA032102050

HB4NS

32

102

50.5

HA032102057

HB4ES

32

102

57.5

HA033053044 HB4000AN

33

53

44

HA036105053

HB6N

36

105

53

HA036105064

HB6E

36

105

64

HA036105080

HB6ET

36

105

80

HA036125053

HB6NS

36

125

53

HA036125064

HB6ES

36

125

64

HA039062046 HB6000AN

39

62

46

HA040118058

HB8N

40

118

58

HA040118074

HB8E

40

118

74

HA040142058

HB8NS

40

142

58

HA040142074

HB8ES

40

142

74

HA042142065

HB10N

42

142

65

HA042142085

HB10E

42

142

85

HA042172065

HB10NS

42

172

65

HA042172085

HB10ES

42

172

85

HA044053044 HB4000AE

44

53

44

HA045072052 HB8000AN

45

72

52

HA045072060 HB8000ANT

45

72

60

HA047047049 HB6FE-AL

47

47

49

HA053053056 HB8FE-AL

53

53

56

HA053062046 HB6000AE

53

62

46

HA054062056 HB10FE-AL

54

62

56

HA065072052 HB8000AE

65

72

52

HA065072060 HB8000AET

65

72

60

Heater(s)
(1) 1500W (1) 1500W (1) 1900W (1) 1900W (1) 1900W (1) 1900W (1) 1000W (1) 1900W (2) 1500W (2) 1500W (2) 1500W (2) 1500W (1) 1500W (2) 1500W (2) 1500W (2) 1500W (2) 1900W (2) 1500W (2) 1900W (2) 1900W (2) 1900W (1) 1000W (2) 1000W (2) 1000W (1) 1500W (1) 1500W (1) 1500W (1) 1900W (2) 1000W (2) 1000W

Sections
2 2 2 2 2 2 2 2 2 2 4 4 2 2 2 4 4 4 4 4 4 2 2 2 2 2 2 2 2 2

For unheated units, replace the “H” in the part# with an “L”. Pad size=inside Dimensions + 12″.

Weight #
152 168 178 192 192 209 121 209 238 278 266 299 155 266 312 311 363 342 404 392 469 147 197 235 149 183 175 197 224 244

20 Hubbell Utility Solutions

Single Aluminum
hubbellpowersystems.com 21

Single Aluminum Enclosures

Dual Aluminum

Wider design for dual or tandem installations. Doors on both sides of the enclosure improve access. Key benefits include (see page 51 for finish and color options):

Quick & Easy Installation – Modular design with a maximum of 4 tongue and groove sections.

Easy Access – Lightweight removable doors can easily be removed by one person.

Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.

Superior Freeze Protection – Insulation will not sag or delaminate from the walls due to the strong chemical bond between the aluminum and insulation. Wall-mounted heaters are installed above the discharge point to provide better long-term performance and safety.

For unheated units, replace the “H” in the part# with an “L”. Pad size=inside Dimensions + 12″.

Catalog Part Number
HA055074057 HA055085057 HA067090050 HA067090057 HA067102050 HA067102057 HA071105053 HA071105064 HA071125053 HA071125064 HA083123058 HA083123074 HA083145058 HA083145074 HA087144065 HA087144085 HA087172065 HA087172085 HA038060043 HA038060048 HA038080043 HA038080048 HA040066045 HA040066051 HA040085045 HA040085051 HA045082051 HA045082062 HA045106051 HA045106062 HA051096054 HA051096067 HA051124054 HA051124067 HA054112059 HA054112075 HA054153059 HA054153075

Model Number HB3E-D HB3E-DS HB4N-D HB4E-D HB4N-DS HB4E-DS HB6N-D HB6E-D HB6N- DS HB6E-DS HB8N-D HB8E-D HB8N-DS HB8E-DS HB10N-D HB10E-D HB10N-DS HB10E-DS HB3FN-D HB3FN-DT HB3FE-D HB3FE-DT HB4FN-D HB4FN-DT HB4FE-D HB4FE-DT HB6FN-D HB6FN-DT HB6FE-D HB6FE-DT HB8FN-D HB8FN-DT HB8FE-D HB8FE-DT HB10FN-D HB10FN-DT HB10FE-D HB10FE-DT

Inside Width (in)
55 55 67 67 67 67 71 71 71 71 83 83 83 83 87 87 87 87 38 38 38 38 40 40 40 40 45 45 45 45 51 51 51 51 54 54 54 54

Inside Length (in)
74 85 90 90 102 102 105 105 125 125 123 123 145 145 144 144 172 172 60 60 80 80 66 66 85 85 82 82 106 106 96 96 124 124 112 112 153 153

Inside Height (in)
57.5 57.5 50.5 57.5 50.5 57.5 53 64 53 64 58 74 58 74 65 85 65 85 43 48 43 48 45 51 45 51 51 62 51 62 54.5 67 54.5 67 59.5 75 59.5 75

Heater(s)

Sections Weight #

(2) 1000W

2

(2) 1000W

2

(2) 1500W

2

(2) 1500W

2

(2) 1500W

2

(2) 1500W

2

(2) 1500W

4

(2) 1500W

4

(2) 1500W

4

(2) 1500W

4

(2) 1900W

4

(2) 1900W

4

(2) 1900W

4

(2) 1000W (2) 1500W

4

(2) 1500W (1) 1900W

4

(4) 1500W

4

(2) 1500W (1) 1900W

4

(4) 1500W

4

(1) 1500W

2

(1) 1500W

2

(1) 1500W

2

(1) 1500W

2

(1) 1500W

2

(1) 1500W

2

(1) 1900W

2

(1) 1900W

2

(2) 1000W

2

(2) 1000W

2

(2) 1000W

2

(1) 1000W (1) 1500W

2

(1) 1000W (1) 1500W

2

(2) 1500W

2

(2) 1500W

4

(1) 1500W (1) 1900W

4

(2) 1500W

2

(1) 1500W (1) 1900W

2

(2) 1900W

4

(2) 1900W

4

223 239 251 270 275 291 338 375 373 415 452 519 491 564 571 674 651 766 145 155 194 200 159 171 207 222 229 256 260 296 269 307 325 366 317 365 394 453

22 Hubbell Utility Solutions

Dual Aluminum Enclosures

Dual Aluminum
hubbellpowersystems.com 23

Hot Box® Custom Enclosures
Do you have a unique project or application? Hot Box® Enclosures have you covered!
Innovative custom Hot Box® Enclosures can be built to fit your specific project. If your project requires pumps, meter bypasses, FDC hookup, custom sizing, options, or custom colors, a full staff of design engineers are available to assist.
For a quote on a custom enclosure, please fill out the checklist on the opposite page and forward it to your area sales representative. The minimum information needed to quote a custom enclosure is: 1) Size of the enclosure 2) Heat required 3) Ventilation required.
Standard options include: vents, exhaust fans, alarm and lighting packages, and special colors (see pages 45-49 for details).
Specialized options include: penetrations, FDC boots, stainless steel anchors, hinged doors, acrylic windows, extra insulation, sound insulation, special voltage heaters, explosion proof heaters/equipment, and different material types like 3003 Mill Finish (.05″) or 5052 Marine Grade aluminum (.050″ or .125″). Contact your representative for details or any other special requirements.
Please Note: Orders for custom enclosures cannot be cancelled once production has begun. In addition, custom enclosures are non-returnable.

Custom Enclosure – Boeing

Custom Enclosure – NASA
24 Hubbell Utility Solutions

Custom Enclosure Gainesville Speedway

Custom Aluminum Enclosures

Custom Enclosure Backflow Prevention Equipment Checklist

Please fill out completely and send to your local manufacturer representative or customer service representative:

Installation Type: Installation Height: Pipe Size:

Valve Type:

Backflow Manufacturer:

Single Line Dual (Manifold) Tandem (2 Separate) Pump (see below)*
Other:

12″ Bottom Clearance 18″ Bottom Clearance 30″ Center line
Other:

1/4″

1/2″

3/8″

5/8″

3/4″

1″

1-1/4″ 1-1/2″ 2″

2-1/2″ 3″

4″

6″

8″

10″

12″

14″

16″

QT OS&Y NRS Butterfly Valves
Other:

Ames Apollo/Conbraco Febco Watts Wilkins
Model #:

18″

20″

24″

Varies (please explain)

Other:

Other:

Please continue for meters or additional backflow device:

Valve Type:
QT OS&Y NRS Butterfly Valves
Other:

Backflow Manufacturer:
Ames Apollo/Conbraco Febco Watts Wilkins Model #:
Other:

Meter Manufacturer:

Meter Type:

Badger Elster Hersey Master Meter

Metron Farnier Neptune Sensus/Omni

Compound Fire Line Turbine

Model #:

Other:

Strainer Type:
Wye Plate Basket None

Additional Equipment:

Altitude Valve Check Valve

FDC (Siamese) Meter Bypass

PRV

Solenoid

Test Tee

Wafer Check Valve

Other: Model #:

Additional Requirements
(Please be specific):
Pump Enclosures:
*Note: If quoting to enclose a pump or pumps, please include pump dimensions or attach specifications to this form. Also, please include clearances.

Job Name: Engineer/Contractor: Distributor: Representative:

Phone: Phone: Phone:

Job Location: Fax: Fax: Fax:

e-mail: e-mail: e-mail:
hubbellpowersystems.com 25

Hot Box® Fiberglass Enclosures
Hot Box® Fiberglass Enclosures are hand crafted to a yacht quality finish to ensure they remain both aesthetically pleasing and meet the needs of your project. The enclosures are built from only the highest quality fiberglass and gelcoat material. The design incorporates bonded foam insulation, and is built to enclose most backflows available on the market. Offering the most comprehensive line of heated and unheated sizes in the market, all standard fiberglass enclosures meet the latest ASSE 1060 performance standards–ensuring that you are purchasing from a dependable source. Benefits include: Enduring Quality – Yacht quality finish with a UV stabilized marine grade gelcoat provides
years of protection for your equipment. Reliable Insulation – All Hot Box models come with spray foam insulation. Spray foam
promotes 100% bonding with the interior wall of the enclosure, preventing deformation in freeze/thaw conditions. Unlike board foam insulation, spray foam insulation will not delaminate and remains firmly affixed to the enclosure’s walls. Better Choices – Many different styles and sizes of fiberglass models are available to quickly meet your needs. Optional Accessories- Add a vent, fan, or alarm to your fiberglass enclosure to make it suitable for a pump or other equipment that needs to be kept cool.
Installation photos of model HB1 with Glass PadTM mounting base
26 Hubbell Utility Solutions

Hot Box® Fiberglass Enclosures
Hot Box® offers the broadest range of fiberglass enclosures in the industry with many different styles and standard sizes. All are built with the same attention to quality and performance that you know and expect from Hot Box. Our comprehensive product offering is designed to ensure that your application requirements are met, and your expectations are exceeded.
Designer SeriesTM Enclosures
Save time and money with quick installation and easy access via hinged access panels, and an opening lid which makes future testing and maintenance easy. Designer Series Enclosures also come with all the other inherent benefits of our fiberglass enclosures, like corrosion and UV resistance, bonded foam insulation, and wall-mounted heaters.
Flip-Top Fiberglass Enclosures
A convenient flip-top lid provides fast and easy backflow access. Weatherproof and vandal resistance is built in with its overlapping lid design.
Vent Guard® & Valve CoverTM Enclosures
Vent Guard is a protective enclosure designed specifically for the air release valves found in many public water supply systems. Valve Cover hinged enclosures are a good choice for landscape and irrigation applications where ease of access for future maintenance is desired.
EZ Box® Enclosures
This economical one piece drop-over design allows quick and easy installation. Ideal for landscape and irrigation applications where future access needs are limited. (See pages 35 & 38)
hubbellpowersystems.com 27

Fiberglass Enclosures

Designer SeriesTM Enclosures
Designer SeriesTM Enclosures are innovative fiberglass enclosures that are perfect when ease of installation and full equipment access are top priorities. Unique design features facilitate quick installation and easy access for future testing and maintenance. Key benefits include:
Quick Installation & Easy Access – Designer SeriesTM Enclosures require minimal installation time. They incorporate easily removable hinged front and rear doors, as well as top lid with gas shock supports. This design provides instant, unobstructed access for equipment testing and maintenance.
Corrosion & UV Resistant – Yacht quality fiberglass with a smooth, UV resistant gelcoat provides a corrosion proof finish that both looks good and stands up to the elements.
High Security – Lockable top lid and internal locks are on both the front and rear doors. Interior steel anchors secure the enclosure to the concrete slab.
Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.
Superior Freeze Protection – Insulation will not sag or delaminate from the walls due to the strong chemical bond between the fiberglass and the insulation. Wall-mounted heaters are installed above the discharge point to provide better long-term performance and safety.
Note: Standard fiberglass color is beige (optional colors are available-see page 51 for details).

Catalog Part Number
LM041041045 LM047047049 LM053053056 LM054062056 HM041041045 HM047047049 HM053053056 HM054062056

Model Number

Inside

Inside

Inside

Width (in) Length (in) Height (in)

LB4FEM

41

41

44

LB6FEM

47

47

48

LB8FEM

52

52

55

LB10FEM

52

63

55

HB4FEM

41

41

44

HB6FEM

47

47

48

HB8FEM

52

52

55

HB10FEM

52

63

55

Heater (if required)
Unheated Unheated Unheated Unheated
1000W 1500W 1500W 1900W

Pad size=inside Dimensions + 12″.

Weight #
241 287 352 389 253 299 364 401

28 Hubbell Utility Solutions

DESIGNER SERIESTM Enclosures

Designer SeriesTM Enclosures
hubbellpowersystems.com 29

Flip-Top Fiberglass Enclosures

Easy Maintenance Access – Flip top lid design provides quick access.
Weatherproof & Vandal Resistance Overlapping lid seam design helps keep vandals and mother nature out. Also includes a lockable top and steel anchors (padlocks are not included).
Durable & Corrosion Resistant – Reinforced fiberglass with a smooth, UV resistant gelcoat provides a corrosion proof finish that both looks good and stands up to the elements.
Superior Freeze Protection – Wall-mounted heater or self-regulating heat trace tape provides freeze protection.
Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.
Note: Standard fiberglass color is beige (optional colors are available-see page 51 for details). Also available as uninsulated enclosures (see page 35).

Catalog Part Number
HF011019022 HF013027023 HF013027035 HF013039028 HF013039036 HF013047028 HF013047036 HF021033025 HF025039028 HF025039036 HF025047028 HF025047036 HF026070045 HF026070055 HF026083045 HF026083055 HL035045035 HL044053044 HF29083062 HL052061052 HF044046050 HF036100075 HF060060060 HF036115075

Model Number
HB.75 HB1 HB1T HB2 HB2T HB2S
HB2ST HB1.5 HB2-D HB2-DT HB2-DS HB2-DST HB3N HB3E HB3NS HB3ES HB3000 HB4000 HBF4E HB5000 HBF4500 HBF6E HBF6000 HBF8E

Inside

Inside

Inside

Width (in) Length (in) Height (in)

Heater(s)

Glass Pad Weight #

10

18

23

30W

GG019027005

28

13

26

23

60W

GG021035005

32

13

26

36

60W

GG021035005

57

13

38

29

90W

GG021047005

54

12

38

36

90W

GG021047005

65

10

44

28

90W

N/A

64

13

47

36

90W

N/A

98

21

33

25

60W GG029042005

55

25

39

28

(2) 90W

N/A

124

25

39

36

(2) 90W

N/A

148

25

47

28

(2) 90W

N/A

139

25

47

36

(2) 90W

N/A

168

27

70

46

1000W

N/A

241

26

70

55

1500W

N/A

322

26

83

45

1500W

N/A

308

26

83

55

1500W

N/A

374

35

44

35

1000W

N/A

170

44

53

45

1000W

N/A

251

29

83

62

(1) 1900W

N/A

277

52

61

51

1500W

N/A

320

44

46

50

(1) 1500W

N/A

192

36

100

75

(1) 1900W

N/A

370

60

60

60

(1) 1900W

N/A

248

36

115

75

(2) 1500W

N/A

441

For unheated units, replace the “H” in the part# with an “L”. Pad size=inside Dimensions + 12″.

30 Hubbell Utility Solutions

Flip-Top Fiberglass Enclosures

Flip-Top Fiberglass Enclosures
hubbellpowersystems.com 31

Vent Guard® Enclosures
Durable & Fast Installation Lightweight enclosure and reinforced exterior mounting flange make installation a breeze (optional interior mounting plates available).
Easy Maintenance – Quick access without removal of entire unit via hinged lid.
Maximum Air Flow – Vent holes are designed to provide proper air flow for air release valves.
Durable & Corrosion Resistant Reinforced fiberglass with a smooth, UV resistant gelcoat provides a corrosion proof finish that both looks good and stands up to the elements.
Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, material construction, equipment access, and functional design are met.
Note: Standard fiberglass color is beige (optional colors are available-see page 51 for details).

Catalog Part Number LV018018024 LV020020036 LV020020041 LV022022040 LV024024048 LV036036048 LV048048048

Model Inside Width Inside Length Inside Height

Number

(in)

(in)

(in)

AVG1824

18

18

24

AVG2036

20

20

36

AVG2041

20

20

41

AVG2240

22

22

40

AVG2448

24

24

48

AVG3648

36

36

48

AVG4848

48

48

48

Glass Pad
N/A N/A N/A N/A N/A N/A N/A

Pad size=inside Dimensions + 12″.

Weight #
43 71 77 90 108 180 210

32 Hubbell Utility Solutions

Vent Guard® Enclosures

hubbellpowersystems.com 33

Valve CoverTM Enclosures
Durable & Fast Installation Lightweight enclosure and reinforced exterior mounting flange make installation a breeze.
Easy Maintenance – Quick access without removal of entire unit via hinged lid.
Durable & Corrosion Resistant Reinforced fiberglass with a smooth, UV resistant gelcoat provides a corrosion proof finish that both looks good and stands up to the elements.
Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.
Note: Standard fiberglass color is beige (optional colors are available-see page 51 for details). Also available as uninsulated enclosures (see page 35).

Catalog Part Number
LC009018018 LC009018024 LC012026020 LC012026028 HC009018018 HC009018024 HC012026020 HC012026028

Model Number

Inside

Inside

Inside

Width (in) Length (in) Height (in)

VC1

9

18

19

VC1T

9

18

26

VC2

12

27

21

VC2T

12

27

27

VCH1

9

18

19

VCH1T

9

18

26

VCH2

12

27

21

VCH2T

12

27

27

Pad size=inside Dimensions + 12″.

Heater
Unheated Unheated Unheated Unheated
30W 30W 60W 60W

Weight #
32 41 47 55 33 42 48 56

34 Hubbell Utility Solutions

Valve Guard® Uninsulated Enclosures
Valve Guard® Enclosures are constructed with the same quality and attention to detail as our standard enclosures, only uninsulated and provide no resistance to freezing temperatures. They are intended for improved aesthetics and security purposes only, not for freeze protection (ASSE Class III). Order insulated and heated enclosures for colder climates (see page 5 for details):
Class III – Non-Freeze Protection Enclosures (Uninsulated Non-Heated): Designed and constructed to provide system security for components when freezing temperatures are not a consideration.

VALVE GUARD® Enclosures

EZ
VE012017021500 VE014021024500
VE006020022 VE014027026 VE012038028 VE013047027 VE026070045 VE035045035 VE044053044 VE052061050

Model Number
VGEZLV.75 VGEZLV1 VGEZ.75
VGEZ1 VGEZ2 VGEZ2S VGEZ3 VGEZ3000 VGEZ4000 VGEZ5000

Enclosure Size (Inside – in)

Mounting Pad

Glass Pad

14W x 19L x 22.5H

29 x 24

N/A

16W x 19L x 25H

33 x 26

N/A

8.5W x 22L x 23H

32 x 16

N/A

16W x 29L x 27H

38 x 25

GG026040005

14W x 40.5L x 29H 48 x 22

GG022056005

15W x 49L x 28H

59 x 22

N/A

29W x 73L x 46H

82 x 38

N/A

38W x 48L x 36H

57 x 47

N/A

47W x 56L x 45H

65 x 56

N/A

55W x 64L x 51H

74 x 64

N/A

Shipping Weight
25# 28# 16# 31# 44# 49# 215# 175# 240# 400#

Valve Guard
VF011019022 VF013027023 VF013027023 VF021033025 VF013039028 VF013039036 VF013047028 VF013047028 VL035045035 VL044053044 VL052061052

Model Number
VG.75 VG1 VG1T VG1.5 VG2 VG2T VG2S
VG3N VG3000 VG4000 VG5000

Enclosure Size (Inside)
13W x 21L x 23H 15W x 29L x 24H 15W x 29L x 36H 23W x 35L x 26H 15W x 41L x 29 15W x 41L 37H 15W x 49L x 29H 29W x 73L x 46H 38W x 48L x 36H 47W x 56L x 45H 55W x 64L x 53H

Mounting Pad
28 x 20 36 x 22 36 x 22 44 x 32 50 x 24 50 x 24 58 x 24 82 x 38 57 x 47 65 x 56 74 x 64

Glass Pad
GG019027005 GG021035005 GG021035005 GG029042005 GG021047005 GG021047005
N/A N/A N/A N/A N/A

Shipping Weight
21# 31# 41# 46# 45# 56# 51# 270# 220# 270# 410#

Glass Roks
VR006015019 VR010026022 VR015040030 VR021067043

Model Number
VGGLR.75 VGGLR1 VGGLR2 VGGLR3

Enclosure Size (Inside)

Mounting Pad

09W x 18L x 20H 13W x 29L x 22H 18W x 43L x 31H 24W x 70L x 44H

27 x 21 40 x 30 51 x 26 90 x 40

Glass Pad
N/A N/A N/A N/A

Valve Cover
VC009018018 VC009018024 VC012026020 VC012026028

Model Number
VGVC1 VGVC1T VGVC2 VGVC2T

Enclosure Size (Inside)
11W x 20L x 19H 11W x 20L x 25H 14W x 28L x 21H 12W x 26L x 28

Mounting Pad Size
27 x 19 27 x 19 35 x 21 35 x 21

Glass Pad
GG019027005 GG019027005 GG021035005 GG021035005

Fiberglass enclosures are constructed of polyester resin with chopped glass. Mounting and access hardware is rust resistant and all enclosures are lockable.

Shipping Weight
20# 41# 75# 310#
Shipping Weight
25# 28# 30# 35#

hubbellpowersystems.com 35

Drop Over Enclosures
Quick & Easy Installation ­ Drop-over design is quick and easy to install.
Affordable ­ Cost effective design is ideal for applications requiring limited access.
Variety of Options ­ Drop-overs are available in Aluminum, Fiberglass or HDPE (Plastic) allowing you to select the best option for your application.
Durable & Reliable – No matter what material is selected, all are built with quality materials which stand up to harsh outside elements.
Superior Freeze Protection ­ Wall-mounted heater or self-regulating heat trace tape provides freeze protection.
Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.
Note: Aluminum enclosures are offered standard with a stucco embossed finish. Smooth mill finish or additional color options are available (see page 51 for details). Standard fiberglass color is beige. HDPE is available in beige or green.

Catalog Part Number

Model

Inside

Inside

Inside

Number Width (in) Length (in) Height (in)

Heater(s)

Glass Pad

Weight #

Material

HJ013026023

AEZ.75H

13

26

23

HJ013038026

AEZ1SH

13

38

26

HJ015047028

AEZ2SH

15

47

28

HE012017021

HEZLVX.75

13

18

21

HE012038028

HEZ2

16

42

29

HE013047028

HEZ2S

13

47

28

**HE026070045

HEZ3

27

70

46

**HE026083045

HEZ3S

26

83

45

**HE035045035

HEZ3000

35

44

35

**HE044053044 HEZ4000

44

53

44

**HE052061050

HEZ5000

52

61

51

HN026070045

NCHEZ3

26

70

45

HN035045035 NCHEZ3000

35

44

35

HN044053044 NCHEZ4000

44

53

44

HN052061050 NCHEZ5000

52

61

51

HP010026023G

PEZ1

10

26

23

HP010026023T

PEZ1

10

26

23

HP015039026G

PEZ2

15

39

26

HP015039026T

PEZ2

15

39

26

90W 90W 90W 30W 90W 90W (2) 90W 1500W 1000W 1000W 1500W (2) 90W 1000W 1000W 1500W 60W 60W 90W 90W

PH25401026A3S 30 Aluminum

PH25401026A3S 34 Aluminum

N/A

38 Aluminum

N/A

29 Fiberglass

GG022056005

33 Fiberglass

N/A

44 Fiberglass

N/A

183 Fiberglass

N/A

310 Fiberglass

N/A

122 Fiberglass

N/A

173 Fiberglass

N/A

238 Fiberglass

N/A

183 Fiberglass

N/A

122 Fiberglass

N/A

173 Fiberglass

N/A

238 Fiberglass

PH25401026A3S 24

HDPE

PH25401026A3S 24

HDPE

PH25401026A3S 35

HDPE

PH25401026A3S 35

HDPE

For unheated units, replace the “H” in the part# with an “L”. Pad size=inside Dimensions + 12″. Some styles also available as uninsulated enclosures (see page 35).
**Catalog Part# LE026070045 through LE052061050 without doors are not ASSE Certified.

36 Hubbell Utility Solutions

AEZ® Aluminum Enclosures
ONLY INCLUDE THE DROP GE BRACKET DRAWING ECHANISIM CALL OUT.

Drop Over Enclosures

X
CLOSURES”

TURN PAGE VERTICAL. ONLY INCLUDE THE DROP OVER 3D DRAWING, HINGE BRACKET DRAWING BELOW AND LOCKING MECHANISIM CALL OUT.
X

hubbellpowersystems.com 37

EZ® Fiberglass Enclosures
38 Hubbell Utility Solutions

Poly EZ Box® (Plastic) Enclosures

Drop Over Enclosures

ANCHOR BRACKET SLOT (1 EACH END)

3/16 X 2 3/4 LG. CONCRETE SCREWS

PAD LOCK LOCATION

Z-BRACKET (HINGE POINT)
SLOT THROUGH THE ENCLOSURE FLANGE
HINGE BRACKET W/ MOUNTING HARDWARE

PAD LOCKABLE BRACKET
LOCKING DETAIL
PAD LOCK (BY OTHERS)

OPEN POSITION

PEZ BRACKET W/ MOUNTING HARDWARE
CLOSED POSITION
hubbellpowersystems.com 39

Fiberglass Hot Rok® Enclosures

Enhances Landscape – Natural rocklike texture and colors are visually appealing.
Quick & Easy Installation – Drop-over design with optional hinge for ease of maintenance on larger Roks.
Durable & Corrosion Resistant Reinforced fiberglass with UV stable gelcoat exterior provides a corrosion proof finish that both looks good and stands up to the elements.
Superior Freeze Protection – Selfregulating heat trace tape provides proven freeze protection.
Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.
Note: Also available as uninsulated enclosures (see page 35).

Catalog Part Number

Model Number

Style

HR006015019E GHR.75 Lift Off

HR006015019N GHR.75 Lift Off

HR010026022E

GHR1 Lift Off

HR010026022N

GHR1 Lift Off

HR010026022500 GHR1 Hinged

HHRR00C1C015o0o02ll4o6o00rr02S3S20p5pE0ee1cciiffiicGcGaaHHtRtRii2o1onn

Hinged Lift Off

HR015040030N

GHR2

Lift Off

HR015040030500 GHR2 Hinged

HR015040030501 GHR2 Hinged

HR021067043E

GHR3 Hinged

HR021067043N

GHR3

Hinged

Color
Brown Granite Brown Granite Brown Granite Brown Granite Brown Granite Brown Granite

Inside Width A
(in) 8 8 10 10 10 10 15 15 15 15 21 21

For unheated units, replace the “H” in the part# with an “L”.

Inside Length B
(in) 16 16 24 24 24 24 40 40 40 40 73 73

Inside Height C
(in) 19 19 19.5 19.5 19.5 19.5 30 30 30 30 43 43

Heater

Weight #

30W

25

30W

25

60W

50

60W

50

60W

50

60W

50

90W

80

90W

80

90W

80

90W

80

2-90W 365

2-90W 365

Available Colors:

“F/GBRroowksn only” “FC/oGloRr ocoksdeon=lyE”
40 Hubbell Utility Solutions

“F/GGRraonkisteonly” “FC/oGloRr ocoksdeon=lyN”

Fiberglass Hot Rok® Enclosures

HotRok® Fiberglass Enclosures

Installation:

1. Provide applicable GFI protected power, UL STND. 943-NEMA 3R, inside enclosures requiring heat. Mount at least 8″ above any discharge point and near the pipe riser on the enclosure access side or install per local code.
2. Pour a full concrete pad 4″ thick around valve, allowing a minimum 1″ radial space between riser and pad or install on a “Glass PadTM”.
3. Place Hot Rok® Enclosure over the valve onto the pad or footer.
4. Use a masonry bit to drill through anchor hinge. Insert concrete screws and bolt firmly to concrete.

5. Mark and mount locking hasp.
6. Mark and mount support rod anchor.
7. For heated enclosures using a self regulating heat trace tape, secure tape to valve with pipe ties or fiberglass/electrician’s tape. No pipe insulation is necessary. The Hot Rok® Enclosure provides the necessary insulation.
8. Plug the heat source into the specified circuit/receptacle, after verifying proper voltage.
9. Lower and secure hasp to staple via pad lock (padlock not included).

hubbellpowersystems.com 41

PolyRok® (Plastic) Enclosures
Enhances Landscape – Natural rocklike texture and colors are visually appealing.
Quick & Easy Installation – Drop-over design is quick and easy to install.
Affordable – Cost effective plastic enclosures ideal for landscape and irrigation applications.
Weed Eater Resistant Anti-chipping plastic construction.
UV & Corrosion Resistant – UV stabilized plastic provides a corrosion proof enclosure that looks good and stands up to the elements.
Freeze Protection – Self-regulating heat trace tape provides proven freeze protection.
Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.

Catalog Part Model

Number

Number

LQ010026022E PLR1
CCLoLoQQllo00o11r0r200SS42pp63e00ec22ci27ifNEfiiccaattPiPioLLoRnRn21
LQ012043027N PLR2 HQ010026022E PHR1 HQ010026022N PHR1 HQ012043027E PHR2 HQ012043027N PHR2

Color
Brown Granite Brown Granite Brown Granite Brown Granite

Inside Inside Inside

Width A Length B Height C

(in)

(in)

(in)

Heater

10

26

22

Unheated

10

26

22

Unheated

12

43

27

Unheated

12

43

27

Unheated

10

26

22

60W

10

26

22

60W

12

43

27

90W

12

43

27

90W

Glass Pad
GG027036005 GG027036005 GG022056005 GG022056005 GG027036005 GG027036005 GG022056005 GG022056005

Weight #
17 17 24 24 18 18 26 26

Available Colors:

“F/GBRroowkns only” “FC/oGloRr ockosdeon=lyE”

“F/GGRraonkitseonly” “FC/oGloRr ockosdeon=lyN”

42 Hubbell Utility Solutions

PolyRok® (Plastic) Enclosures

PolyRok® Enclosures

Installation:
1. Provide applicable GFI protected power, UL STND. 943-NEMA 3R, inside enclosures requiring heat. Mount at least 6″ above any discharge point and near the pipe riser on the enclosure access side or install per local code.
2. Pour a full concrete pad 4″ thick around valve, allowing a minimum 1″ radial space between riser and pad or install on a “Glass PadTM”.
3. Place PolyRok® Enclosure over valve and onto the pad or footer.
4. Mark locking staple. Position on concrete.

5. Use a masonry bit to drill through anchor hinge. Insert concrete screws and bolt firmly to concrete.
6. For heated enclosures using a self regulating heat trace tape, secure tape to valve with pipe ties or fiberglass/electrician’s tape. No pipe insulation is necessary. The PolyRok® Enclosure provides the necessary insulation.
7. Plug the heat source into the specified circuit/receptacle, after verifying proper voltage.
8. Lower and secure staple via pad lock (padlock not included).

hubbellpowersystems.com 43

Pump Guard Enclosures

Extended Pump Life – Vented enclosures are designed to keep pumps cool and protected from the elements.
Reduce Noise – Keep neighbors happy by dampening the sound with standard insulated models (optional soundproof insulation available).
Vandalism & Theft Deterrent Secure lockable enclosures can reduce unwanted access.
Peace of Mind – ASSE 1060 certification ensures that requirements for structural strength, drainage capacity, material construction, equipment access, and functional design are met.
Increased Cooling Performance – Optional fans and thermostatically controlled louvers can improve cooling performance (see page 46 for details).
Note: Available in all Designer Series, Flip-Top, and aluminum enclosures (popular models below). Standard fiberglass color is beige (optional colors are available-see page 51 for details).

Catalog Part Number

Model Number

Access Type

Inside

Inside

Inside

Width (in) Length (in) Height (in)

Heater

Weight #

HF013027023AAV PG1000H Flip-Top

13

27

23

60W

40

HF021033025AAV PG1500H Flip-Top

21

33

25

60W

60

HL035045035AAV PG3000H Flip-Top

35

45

35

1000W

250

HL044053044AAV PG4000FH Flip-Top

44

53

44

1000W 300

HL052061052AAV PG5000H Flip-Top

52

61

52

1500W

440

HM041041045AAV

PG4000H

Top, Front & Back

41

41

45

1000W

280

HM047047049AAV

PG6000H

Top, Front & Back

47

47

49

1500W

300

HM053053056AAV

PG8000H

Top, Front & Back

53

53

56

1500W

335

HM054062056AAV

PG10000H

Top, Front & Back

54

62

56

1900W

485

For unheated units, replace the “H” in the part# with an “L”. Pad size=inside Dimensions + 12″.

44 Hubbell Utility Solutions

Pump Guard Enclosures
MODEL NUMBERS PG4000H PG6000H PG8000H PG10000H

Pump GuardTM Enclosures

MODEL NUMBERS PG1000H PG1500H

MODEL NUMBERS PG4000FH PG5000H
hubbellpowersystems.com 45

Glass PadTM Mounting Bases
Mounting Pads for Backflow Enclosures
Save Time & Money – No forms to build or concrete to pour.
Quick Installation – One trip to install Glass Pad and enclosure with no waiting for concrete to cure.
Aesthetically Pleasing – Professional looking installation with matching enclosure and pad.

Catalog Part Model Inside

Inside

Inside Weight

Number Number Width (in) Length (in) Height (in) #

For Enclosure Model Number

Material

GG019027005 GP.75

19

27

4

16

(HB, LB, VG) .75 + (VC, VGVC) 1 & 1T

Fiberglass

(HB, LB, VG, PEZ) 1 & 1T

GG021035005 GP1

22

36

4

20

+ (VC, VGVC) 2 & 2T + Fiberglass

PG1000

GG021047005 GP2

21

47

4

25 (HB, LB, VG, PEZ) 2 & 2T Fiberglass

GG022056005 GPPR2

23

57

4

27

(PHR, PLR, VGPLR) 2 + (EZ, VGEZ) 2

Fiberglass

GG026040005 GPEZ1

26

40

4

26

(EZ, VGEZ) 1

Fiberglass

GG027036005 GPPR1

27

36

5

22

(PHR, PLR, VGPLR) 1 Fiberglass

GG029042005 GP1.5

30

42

4

30 (HB, LB, VG) 1.5 + PG1500 Fiberglass

PH25401026A3S 25

40

PH31551336A3S

31

54.5

3.25

10×26

80

AEZ.75H, AEZ.75L, PEZ1

Polymer Concrete

3.25

13×36

137

AEZ1SH, AEZ1SL, PEZ2

Polymer Concrete

46 Hubbell Utility Solutions

Glass PadTM Mounting Bases Enclosures

Options: General & Vents
Hot Box® Enclosures can be modified to meet your specific project requirements. Below are many of the options that are available:
Standard options include: vents, exhaust fans, alarm and lighting packages, and special colors (see pages 45-49 for details).
Specialized options include: penetrations, FDC boots, stainless steel anchors, hinged doors, acrylic windows, extra insulation, sound insulation, special voltage heaters, explosion proof heaters/equipment, and different material types like 3003 Mill Finish (.05″) or 5052 Marine Grade aluminum (.050″ or .125″). Contact your representative for details or other special requirements.
Vent Features:
4″ diameter aluminum fixed blade wall vent with foam rubber winter cover that is sized to be pushed inside the vent itself. It is pliable and soft, molding into the opening without resistance.
12″ x 12″ aluminum fixed blade wall vent with integrated insect screen.
Winter covers are included to help prevent heat loss in the winter. They slide against the back side of the vent and are constructed of the same stucco embossed aluminum as the enclosure (non-insulated).
Vent location and quantities vary depending on the size of the enclosure.
Vents come fully installed.
Vent Maintenance:
Install the winter covers when temperatures hold at 40°F or less for any prolonged period of time.
When temperatures rise above 40°F, remove winter covers. Winter covers must be removed when a fan is in use.

4″ Diameter Round Vent

12″ x 12″ Square Vent (Outside)

12″ x 12″ Square Vent-Inside without Winter Cover

12″ x 12″ Square Vent-Inside with Winter Cover
hubbellpowersystems.com 47

Options: Exhaust Fan

Features:
10″ diameter 5 blade exhaust fan Adjustable thermostat Automatic gravity shutter Wire fan guard 10″ diameter 5 blade exhaust fan Totally enclosed motor UL listed for US and Canada Fixed blade wall vent(s) & winter cover(s)
to prevent heat loss in cold weather

Technical Specs:

120 volt single phase

60 Hz 1/30 hp motor

Complete Exhaust Fan (Interior View)

1550 rpm

585cfm @ .00-In. SP

Maximum 1.5 amps

Maximum Ambient Temp. 104 degrees F

Fan location, vent size, and quantity of fan(s) can vary, based on the size of the enclosure

Installation:
Contractors other than Hot Box® are responsible for the installation of the G.F.I. protected 15 amp, 120v, single phase service and receptacle. All installations to be in accordance with local and national codes.
Plug the fan into the receptacle.
Adjust the thermostat to the desired temperature.

Maintenance:
Install the winter covers into the vents when temperatures hold at 40°F or less for any prolonged period of time. When the weather warms again, and the temperatures consistently reaches 40°F at night, winter covers must be removed.
Keep the area around the automatic shutter free of objects that could impede air flow.
Lubricate the motor sleeve bearings annually using S.A.E. 20 (non detergent) oil.

48 Hubbell Utility Solutions

Options & Accessories

Options: Alarm Packages
Power Loss Alarm
Power Loss & Low Temperature Alarm

PLAHBO Audible Power Loss Alarm – The alarm consists of the cabinet, battery, battery charger, relays, 95-decible horn, six foot power cord and plug. The alarm is designed to activate the horn if the enclosure loses electrical power.

PLAHBOS Visual Power Loss Alarm – The alarm consists of the cabinet, battery, battery charger,

relays, ambeelrecstrticraol pboewelrigorhiftth, estiexmpfoeraotutrepfoallws beerlowcothredseat “naddjusptalbuleg” .teTmhpeeraatulrae rm is designed to activate the strobe light if the enclosure loses electrical power.

electrical power or if the temperature falls below the set “adjustable” temperature
PLAHBO-T AsuuredloisbesleelePctoricwaleporwLeroosr sif tahentdemLpeorawtureTfealmls bpeelowrathteusreet “aAdljuasrtamble”-teTmhpeeraatulraerm consists of the cabinet, battery, battery charger, relays, 95-decible horn, temperature sensor, six foot power cord and

ptesluumrgep.loeTsrehaseteualerlecatrrficmaalllspisobwdeeerlosoiwrgifntthehedetetsmoeptae”rcaattduivrjeautfsaetllastbhbeleelo”hwottehrmenspieftet”rhaadetjuuesrtnaebc.lleo” steumrepelroatsueres

electrical

power

or if the
“adjustable”

PLAHBOS-T Visual Power Loss and Low Temperature Alarm – The alarm consists of the cabinet, battery, battery charger, relays, amber strobe light, temperature sensor, six foot power cor”addjaunstdable” plug. The alarm is designed to activate the strobe light if the enclosure loses electrical power or if the temperature falls below the set “adjustable” temperature.
PLAHBOT-S Audible and Visual Power Loss and Low Temperature Alarm – The alarm consists of the cabinet, battery, battery charger, relays, 95-decible horn, amber strobe light, temperature sensor, six foot power cord and plug. The alarm is designed to activate both audible and visual notifications if the enclosure loses electrical power or if the temperature falls below the set “adjustable” temperature. Note: With a fully charged battery the alarm should activate for a minimum of six hours or until deactivated. Alarms operate on 120V, single phase service and plugs into a G.F.I. receptacle.

Installation:

Contractors other than Hot Box® are responsible for the installation of the G.F.I. protected 20 amp, 120V, single phase service and receptacle. Alarm and Heater must be supplied by the same electrical service. All installations to be in accordance with the local and national codes.

Simply plug the alarm into the receptacle and turn the switch to the on position.

For low temperature alarms, adjust the thermostat to desired temperature (34°-38°F recommended).

hubbellpowersystems.com 49

Options: Lighting Packages

Increased Visibility – Lighting illuminates equipment for easier maintenance.

Peace of Mind – UL listing for wet & damp locations ensures safety.

Packages:

Single Light Package – One 24″ fluorescent light fixture in a water tight enclosure and hardwired to a single electrical switch.
Double Light Package – Two 24″ fluorescent light Sfiinxgtluerleigshtinpawckaatgeer: tOigneht24e”nflculooressucreenst laignhdt fhixaturrdewiniraewdatteor tight a single electrical switch.
DQouubaledliLgihgt hpatcPkaagcek:aTgweo -24F”ofluorr2es4c”enfltulioghret sfixcteunretslinghwtater tight fixtures in water tight enclosures and hardwired to Qauasdinlgiglhet pealeckcatgriec:aFlosuwr 2it4c”hfl.uorescent light fixtures in water tight Note: The light package required will vary depending on the size of the enclosure.

Single Light Package (Installed)

Technical Specs:
24″ fluorescent T8 bulb 17 watts (each) 120 volt single phase

Ins24t”afllulaorteisocenn:t T8 bulb
Contractors other than Hot Box are responsible for the installation of the G.F.I. protected 120v, single phase service to the switch. All installations to be in accordance with the local and
national codes.
After enclosure installation is complete, plug in each light in tandem to the next light (if multiple lights are supplied).

50 Hubbell Utility Solutions

Options & Accessories

Options: Colors
Standard Colors:
All standard Aluminum Enclosures come with a stucco embossed aluminum finish. No color code is required for the stucco embossed aluminum finish. If a mill finish is required, please specify by adding an “L” in the 12th digit of the part number.
All fiberglass enclosures come standard with a beige gelcoat (color code not required).
All plastic Poly EZ Box® Enclosures are available in beige (T) or dark green (G) only. Please add color code suffix.
All fiberglass Hot Rok® Enclosures are available in brown (E), granite (N) only. Please add color code suffix.
All plastic PolyRok® Enclosures are available in brown (E) or granite (N). Please add color code suffix.
Optional Colors:

Beige Color code = T

Federal Brown Color code = M

Dark Green Color code = G

Black Color code = B

White (Sail) Color code = W

Grey Color code = C

Brown “F/G Roks only” Color code = E

Granite “F/G Roks only” Color code = N

Notes:

If non-standard color is required, please specify the color code in the 12th digit of the part number.

The above shown colors may not be an accurate representation of the actual color. If needed, please request a sample from your local Hot Box representative before ordering. Customer approval is required prior to processing the order.

Custom colors not shown above will require a color sample, Federal Standard color, Munsell color or Sherwin Williams color number.

Aluminum/Prep Procedure:
Preparation of the exterior of the enclosure to accept paint involves sanding the aluminum and applying a solvent to remove dust and aluminum filings. A Mopoxy high build epoxy primer (Lead and Chromate free) is then applied to allow a Mothane Polyurethane enamel paint (Lead and Chromate free) to adhere properly. Prefinished aluminum sheets are used for the beige and federal brown colors.

Fiberglass Gelcoat:
Any special gelcoat color will be applied at a thickness of 18 mils.

hubbellpowersystems.com 51

Standard Drawings

ACCESS DOOR WITH LOCKING HANDLE ACCESS DOOR WITH LOCKING HANDLE

PAD LOCKABLE HANDLE PAD LOCKABLE HANDLE
) )
PAD LOCKABLE HANDLE

ACCESS DOOR WITH LOCKING HANDLE

LIFTING HANDLE
PREFABRILCIFATTINEGD HSANEDCLTEIONAL PREFABRICATED SECTIONAL

DRAINPORT (TYPICAL) DRAINPORT (TYPICAL)

LIFTING HANDLE
PREFABRICATED SECTIONAL

DRAINPORT (TYPICAL)

)

ACCESS DOOR WITH LOCKING HANDLE ACCESS DOOR WITH LOCKING HANDLEDRAINPORT
(TYPICAL) DRAINPORT (TYPICAL)
ACCESS DOOR WITH LOCKING HANDLE
DRAINPORT (TYPICAL)

ALUMINUM MODULAR ALUMINUM MODULAR

HINGED TOP PANEL HINGED TOP PANEL
HINGED TOP PANEL

ALUMINUM MODULAR

DRAINPORT (TYPICAL) DRAINPORT (TYPICAL)

DRAINPORT (TYPICAL)

DURAFOLD DURAFOLD
DURAFOLD

HEATER (IF REQUIRED) HEATER (IF REQUIRED)
HEATER (IF REQUIRED)
FOLD DOWN PANEL FOLD DOWN PANEL
FOLD DOWN PANEL

52 Hubbell Utility Solutions

Standard Drawings

Standard Drawings
hubbellpowersystems.com 53

Frequently Asked Questions
Are Hot Box® Enclosures ASSE 1060 certified?
Yes, standard Hot Box® Enclosures have been lab tested and ASSE 1060 certified for vertical roof load (100 lbs/ft2) capacities, freeze protection, drainage aptitude and material construction.
Custom enclosures are not certified to the ASSE 1060 standard due to the timeline required to qualify a new unit. However, custom enclosures are manufactured with the same quality materials and methods as our standard units which meet the necessary requirements set forth by ASSE 1060.
Do I need a heated or unheated enclosure, or what ASSE class enclosure do I need?
This question is best answered by comparing the lowest average winter temperature at your location to the definition of the ASSE Class ratings. See below:
Class I – Freeze Protection Enclosures (Heated): Designed and constructed to maintain a minimum internal temperature of 40°F with external temperatures as low as -30°F.
Class II – Freeze Retardant Enclosures (Insulated Non-Heated): Designed and constructed to be installed in locations with minimum temperature of 33°F.
Class III – Non-Freeze Protection Enclosures (Uninsulated Non-Heated): Designed and constructed to provide system security for components when freezing temperatures are not a consideration.
Can you manufacture custom size enclosures? If so, what are the maximum dimensions?
We can create custom sizes with our aluminum sectional and Dura Fold® Enclosures. Please speak with your area sales representative for dimensions.
Custom sectional aluminum enclosures are limited to a maximum interior width of 117″ and a maximum interior height of 106.5″ with the length being unlimited.
Custom Dura Fold® Enclosures are limited to a maximum top surface area of 22 sq ft (3168 sq in) or less and a maximum interior length of 90″ and height of 66″.
What is the largest removable access panel?
Due to weight constraints set by ASSE 1060 3.3.3 specification, 44″ W x 77 ½” H is the largest removable access panel.
When a wider opening is required two 36″ W x 72 ½” H dual hinged access doors will give you a 72″ W x 72 ½” H opening.
Will field penetrations affect the structural integrity or freeze protection of the enclosure?
The structural integrity will not be affected when putting holes in an enclosure (maximum size of 12″ diameter). However, it is important to not modify any of the corners or seams of a Hot Box (where two different surfaces meet), since this will reduce the structural integrity of a Hot Box® Enclosure. When in doubt or for special requirements, please contact our Customer Service Team.
To minimize heat loss it is recommended you make the hole ½” larger than the pipe diameter. Then after installation apply expanding foam (found at any hardware store) around the perimeter of the penetration.
54 Hubbell Utility Solutions

Frequently Asked Questions
Is it necessary to have 3″ insulation (R19) in the roof or the walls?
Hot Box® Heaters and 1 ½” (R10) insulation are more than sufficient to maintain an interior temperature of 40°F (4.4°C) and protect equipment from external temperatures as low as -30°F (-34.4°C) in accordance with ASSE 1060 3.6.1-3.
Some competitors require 3″ of insulation due to the use of less efficient slab mounted heaters.
If desired, 3″ (R19) insulation is available for an additional fee.
What is the recommended slab size for Hot Box® Enclosures?
The slab should be 12″ larger than the interior dimensions of the enclosure. The minimum recommended slab thickness is 4″.
What are the standard heater electrical connection recommendations?
Contractors other than Hot Box® are responsible for the installation of the G.F.I. protected service and receptacles (mounted a min. of 9″ above the slab).
We recommend that each heater be on separate 20 amp circuits. Separate circuits help provide redundancy in the event that one circuit fails.
All installations must be in accordance with local and national codes.
What is the wind load rating for Hot Box enclosures?
All standard fiberglass enclosures are suitable for wind speeds up to 120 mph.
All standard Sectional Aluminum, Dura Fold® and Modular Enclosure sizes up to 36″W x 105″L x 64″H inside dimensions (i.e., LA036105064) and smaller are suitable for speeds up to 120 mph. Standard sizes larger than 36″W x 105″L x 64″H are suitable for use in areas where the design wind speed is 80 mph or less.
Hot Box® Enclosures have not been certified to meet the wind-borne debris impact requirements in areas within a few miles of the coast (e.g. Florida Building Code).
Does Hot Box have three phase and explosion-proof heater options?
Hubbell can provide a three phase and explosion-proof heater comparable to the conventional heater in the standard Hot Boxes. Longer time lead times and higher costs will apply compared to the regular units. Please contact your local representative or the Hubbell Water Market Customer Service team for further detail.
Is there a Stainless Steel Hot Box option?
No. We provide Aluminum, Fiberglass, and Plastic options.
Is there a marine aluminum Hot Box option?
Yes, we can make an aluminum Hot Box with 5052 Marine Grade aluminum (.050″ or .125″). Please contact your local representative or the Hubbell Water Market Customer Service team for further details.
Can Hot Box be used for non-backflow applications?
Yes, Hot Boxes can be used for many applications including but not limited to Pumps (See Pump Guard Enclosures), Water Tanks, and other valves and fluid conveying devices.
Are Hot Box enclosures water-tight?
No, ASSE 1060 requires backflow preventer enclosures not be water-tight so any excess water coming from the backflow can drain through the built in drain ports as necessary. Hot Box enclosures provide the protection needed from the elements.
hubbellpowersystems.com 55

Frequently Asked Questions

Installation Guide for Sectional Enclosures
1. Remove the access panels from the sections and place aside. This will lighten the sections for an easier installation.
2. Place the sections as close to their final positions as possible. The order of installation is always “Rear” left to right and then “Front” left to right regardless of the number of sections your enclosure has (4 section shown).
3. Each section has a male and a female edge. Lift each section (10″-12″) and position over the mating edge and carefully lower the section into position keeping it flush against the opposing section’s edge until it seats properly.
4. Place the enclosure in its final position. Do not tear the gasket on the enclosure base or around the male/female edges while sliding the sections together or positioning the enclosure.
5. The enclosures must be squared and leveled to assure proper fit of the sections. The anchor pads within the enclosure double as levelers. If needed, loosen the bolts attaching the anchor pads to the enclosure. Each pad is slotted for vertical movement. When level, tighten the pad bolts to the enclosure wall.
6. Once the enclosure is level and square, set the access panels in place. If the fit is not right or if light may be seen through any seam, the square of the enclosure is incorrect and must be reassessed.
7. After all is in place, remove the access panels once more. Install the interior anchors to secure the enclosure. Anchors and drill bit are included.
56 Hubbell Utility Solutions

Installation Guides

Installation Guide for Sectional Enclosures
8. Determine if your enclosure has Beam clamp or Cam-locks (see diagram above). Only one type should exist per enclosure.
9. For Beam clamp style enclosures: tighten the Beam clamp eyebolts and wing nuts (located at the top seam inside the enclosure).
10. For Cam-lock style enclosures: fully engage the Cam-locks (located on the exterior walls along the seams) using the supplied allen wrench tool. Place the plastic plugs in the keyholes for protection.
11. Enclosures larger than 72″ wide (inside) will be supplied with 2 x 1 support channels. They are attached with the supplied hardware to the underside of the horizontal roof bracing. Use a ratchet and a 1/2″ deep socket to attach.
12. In some cases the size of the enclosure (typically 4 sections and larger) may cause a slight leaking during inclement weather. To prevent this, Aluminum tape has been provided (for 4 sections and larger). We recommend that the contractor lay a bead of silicon caulking in all seams and tape over the entire seam on the top of the enclosure. This is for situations where the enclosure is to be a “permanent” structure.
13. For enclosures with four or more sections, square cap plates have been supplied to cover the areas where the four corners of the sections come together on the top of the enclosure. Place the caps over the intersection and screw into place.
14. Hang the heater(s) on the heater plate(s) and plug into the receptacle(s). 15. Place the access panels in their respective openings and insert padlocks (not included) through
the handles. Warning! A ground fault circuit interrupting device shall be installed in the electrical supply circuit to the heater(s). Failure to do so may result in injury or death. The interior of this enclosure can be a damp location. Contractors other than Hot Box® are responsible for the installation of the G.F.I. protected service and receptacles (ref. UL 943, NEMA 3R). When multiple heaters are required it is recommended that each heater be on a separate 20 amp circuit. Separate circuits help provide redundancy in the event that one circuit fails. Consult local and national codes for electrical connections.
hubbellpowersystems.com 57

Installation Instructions for Durafold Enclosures
Installation Guide for Standard Dura Fold® Enclosures
In most cases, Dura Fold® Enclosures are shipped assembled. If so, please skip to step 3. *Note: The receptacles and the concrete slab should be prepared and fully cured before the enclosure is uncrated. 1. Position the “B” Panels around the installed valve maintaining clearance between the enclosure
and the installed valve. Do not tear the gasket on the enclosure base while positioning or joining the enclosure panels. 2. Secure Panel “A” to Panel “B” using 5/16″ wing nuts. 3. The enclosure must be squared and leveled. The L-shaped anchor pad brackets supplied with the enclosure double as levelers. If needed, loosen the bolts attaching the anchor pads to the enclosure. Each pad is slotted for vertical movement. When level, tighten the pad bolts to the enclosure wall. If the enclosure is not properly squared and leveled, then the lids may not close properly. Do not force lids closed as this may cause damage. 4. To install the concrete anchors in the slab, drill through the anchor pads and drive each concrete anchor into each drilled hole. Place the washer and nut on the top of the anchor and tighten. Concrete anchors and a drill bit are included. 5. If applicable, mount the heater to the heater plate using the supplied screws. If using heat trace tape, wrap the heat tape in a spiral or straight line (depending on length) around the pipe risers and backflow device. Avoid overlapping the heat tape. Secure on 12″ centers using glass cloth tape or plastic cable ties. Restrain the plug end of the cord to provide proper strain relief and plug into a G.F.I. protected receptacle. 6. When vents are present, install the winter cover (according to the season). 7. Raise hinged front and back panels into place, and latch the internal latches inside. 8. Close the lid and hang a padlock on each hasp and staple to secure (padlock not included). Warning! A ground fault circuit interrupting device shall be installed in the electrical supply circuit to the heater(s). Failure to do so may result in injury or death. The interior of this enclosure can be a damp location. Contractors other than Hot Box® are responsible for the installation of the G.F.I. protected service and receptacles (ref. UL 943, NEMA 3R). When multiple heaters are required it is recommended that each heater be on a separate 20 amp circuit. Separate circuits help provide redundancy in the event that one circuit fails. Consult local and national codes for electrical connections.
58 Hubbell Utility Solutions

Installation Guides

Installation Guide for Double Dura Fold® Enclosures
In most cases, Dura Fold® Enclosures are shipped assembled. If so, please skip to step 4. *Note: The receptacles and the concrete slab should be prepared and fully cured before the enclosure is uncrated. 1. Position “L” and “R” panels against the installed valve. Do not tear the gasket on the enclosure
base while positioning or joining the enclosure panels. 2. Secure Panel “F” to Panel “L” and “R” using 5/16″ wing nuts. 3. Secure Panel “B” to Panel “L” and “R” using 5/16″ wing nuts. 4. The enclosure must be squared and leveled. The L-shaped anchor pad brackets supplied with
the enclosure double as levelers. If needed, loosen the bolts attaching the anchor pads to the enclosure. Each pad is slotted for vertical movement. When level, tighten the pad bolts to the enclosure wall. If the enclosure is not properly squared and leveled, then the lids may not close properly. Do not force lids closed as this may cause damage. 5. To install the concrete anchors in the slab, drill through the anchor pads and drive each concrete anchor into each drilled hole. Place the washer and nut on the top of the anchor and tighten. Concrete anchors and a drill bit are included. 6. If applicable, mount the heater to the heater plate using the supplied screws and plug into a G.F.I. protected receptacle. 7. When vents are present, install the winter cover (according to the season). 8. Raise hinged front and back panels into place, and latch the internal latches inside. 9. Close the lid and hang a padlock on each hasp and staple to secure (padlock not included). Warning! A ground fault circuit interrupting device shall be installed in the electrical supply circuit to the heater(s). Failure to do so may result in injury or death. The interior of this enclosure can be a damp location. Contractors other than Hot Box® are responsible for the installation of the G.F.I. protected service and receptacles (ref. UL 943, NEMA 3R). When multiple heaters are required it is recommended that each heater be on a separate 20 amp circuit. Separate circuits help provide redundancy in the event that one circuit fails. Consult local and national codes for electrical connections.
hubbellpowersystems.com 59

Anchor Installation & Specification
Single and Double Anchor Kit:
Used on Sectionalized Aluminum, Modular Aluminum, Dura Fold®, Designer SeriesTM and F/G Flip-Top Enclosures.
Note: Anchor type and quantity will vary depending on the type of the enclosure.
Technical information:
Ultimate strength of wedge anchor: Pull out: 2,300lbs – Shear: 2,400lbs.
Installation:
1. Locate the Anchors. Mark and drill 3/8″ diameter holes x 1 3/4″ – 2″ deep with the supplied bit. 2. Drive the anchor into the hole, place the anchor pad over the anchor and tighten the washer
and nut.
EZ Anchor Kit:
Used on Fiberglass EZ Box® & Hot Rok® and AEZ.75 Aluminum Enclosures”
Installation:
1. Locate the brackets. Mark and drill 5/32″ diameter holes x 3″ deep with the supplied bit. 2. Attach the brackets with the supplied concrete screws. Screws will be hidden under the flange
of the enclosure.
60 Hubbell Utility Solutions

Installation Guides

Anchor Installation & Specification
PEZ Anchor Kit:
Used on HDPE PEZ, Plastic PolyRok® and Aluminum AEZ1S and AEZ2S Enclosures.
Installation:
1. Locate the brackets. Mark and drill 5/32″ diameter holes x 3″ deep with the supplied bit. 2. Attach the brackets with the supplied concrete screws. Screws will be hidden under the flange
of the enclosure.
Drive Anchor Kit:
Used on Vent Guard® and Valve CoverTM Enclosures.
Note: Anchor quantity is typically four per enclosure.
Installation:
1. Locate the holes in the flange. Mark and drill 1/4″ diameter holes x 2 1/2″ deep with the supplied bit.
2. Place the anchor through the enclosure flange and into the drilled hole, then hit with a hammer. Warning! A ground fault circuit interrupting device shall be installed in the electrical supply circuit to the heater(s). Failure to do so may result in injury or death. The interior of this enclosure can be a damp location. Contractors other than Hot Box® are responsible for the installation of the G.F.I. protected service and receptacles (ref. UL 943, NEMA 3R). When multiple heaters are required it is recommended that each heater be on a separate 20 amp circuit. Separate circuits help provide redundancy in the event that one circuit fails. Consult local and national codes for electrical connections.
hubbellpowersystems.com 61

Features:

Adjustable thermostat

Standard Convection 100cfm fan (factory lubricated) Quiet operation

Heaters

Freeze Protection

Rev 4/19

Durability & long life
BeFanset afintdseaasny dinsFtaellaatitoun raends:maintenance
Factory coated beige finish

6′ power cord and plug Better Freeze Protection – Heater is thermostatically controlled to maintain an interior

Sttaenmdaprdesr:ature of 40°F (4.4°C) to protect equipment from external temperatures as low as

^ET-L30lis°teFd(,(-te3s4t^e.4d°fCor)wient/ZadacmcoprlodcaaZnticone,sw)ithASSE 1060 1.2.2.1.

^TtehmBepermetrt,oaestutrartPe^icseaarllfsyolcorowmntaarZosnll- ce3de0°taoFnm(-d3Za4iSn.4taa°,fiCne)taynini-natcWecroiaorlrdl- atemnmcoepuewrnaitthtueArdeSodSfEe4s01i°0gF6n0(4e1.4l.e2°.Cv2a).1ta.ensd phreoatetcetreqaubipomveendt firsocmheaxrtgeernaploint.

FAedajutsuDtraeibFeslel:aetschtterircamnVodsotlatEat gaesyWiItnhssttaanldlaTteisotn(S-e6ct’iopno4w4.e0rocf tohredUaLn4d99pSlutagn.dard & Section 6.4 of the CAN/CReSv 4A/19C22.2, No. 88

Featu10re0sc:fmstafannda(fradc)t.ory lubricated)

Rev 4/19

A1Q0du0jiuecsQFDtfmtrouaueprbiefeaealzetbrnGaeoailtriph(trtPdQifyooeear)urnor.&cuamnttetoilidooeocrnisytnntitgoalgunOltibCferpiocenartteiandut )itoynTe-sFt (aScetcotiroyn 4lu5b.1riocfathteedUL104909cSftmandfaarnd.& Section 6.5 of the CAN/CSA C22.2, No. 88 stand-

FDruereazFFbeaailiscMtPyttorao&renytedlecocoenttiaagostsnelyidfoeinbrsetiaEglelaxfticinoineshaendd msaSintteananndceards:

FFaasctto6ar’nypdcooweaaetsrEeycdToinbLrsdetialgilnseladtfteiipnodlinusgha(ntdesmtaeindtefnoarncwe et/damp locations).

6SE’tTapLnoSETtlwdeishtTameateLrernpdrdcmldeisso(rao:ttarreesTe1dtdd0utsqahsatr(et6e:neuitcdesd0raispafmlptolesy1lmrud.olc2wogofeswo.en2tnrtt/aa.rwdt1ost .aelfli- metc3r/ddo0paa°tmllomFolycmp(-ae3acltox4iioonc.t4antnea°tsiiCtro)nrnn)aosani)lnllienattdceecrmoitorordpateemnmrcaaepteiwnuraittrhtaueArisenSoaSafsEn401lo°i0nFw6t0(e41a.r4.si2°o.C2-r).31at0.ned°mFprpo (et-e3rcat4te.uq4ur°iepCmo)efnint4fr0aocm°cFeox(rt4edr.na4an°l cCe)

and protect with ASSE

TtehmeprmDsetiraoeansltedutacartterricdisDca)a .VlilesyollctoeaowcgnettarrosWilcl-ei3thdV0s°ttooFalnm(td-a3aT4gine.e4tsa°tiCW n(S)aeinitcnhtiinaostcnetcra4oio4nrrd.0datenomTcf eetpheswertaiUtht(LuSAr4eeS9ocS9ftES4iot01a°0nnF6d04a(4r14d.4.2.&°0C.2S).oe1ac.fntidtohnper6o.t4UecoLtf

ethqeuCipAmNe/nCtSfrAomC2e2x.t2e,rNnaol. 88
499 Standard & Section

6.4

of

the

DieleGctrroicunVdoiCnltgaAgCeNoWn/tCiinthSusiAttyanTCdes2Tt2e(Ss.2te(,cStNieocnoti4.o5n8.1844os.f0tthaoefntUdhLea4Ur9dL9)4S.9ta9nSdtaarndd&arSde&ctSioenc6ti.o5no6f .t4heofCtAheN/CCASNA/CCS22A.2C, 2N2o..28, 8Nost.a8n8d-

standaardrd).).

Grounding CGonrtoinuunitydTinesgt (CSeocntiotnin4u5i.t1yofTtehestU(LS4e99ctSitoannd4ar5d.&1 oSfectthioen 6U.5Lo4f t9he9CSAtNa/CnSdAarCd22&.2,SNeoc. t8i8osnta6nd.5- of the CAN/

ard).

CSA C22.2, No. 88 standard).

HoMt Boodxel

Wattage

3A6C2I1100In0d-1u2s0trial Par1k00D0rive

Lenoir City, TN37771

ACI1500-120

1500

Voltage
120 120

Phase
1 1

ACI2000-120

2000

120

1

Btu/Hr

Weight Lb.

3412

12

5118 1

12

6824

12

Recommended Circuits
20 AMP 20 AMP 20 AMP

Plug ContaTcthIenrfomrmosattiaotn NEMAP5h-2o0npe: (800)In3t4er6n-a3l062
[email protected] NEMA 5-20pwww.hoInt-tbeornxa.lcom

NEMA 5-20p

Internal

ACI1000R-120

1000

120

1

3412

12

20 AMP

NEMA 5-20p

Remote

ACI1500R-120

1500

120

1

5118

12

20 AMP

NEMA 5-20p

Remote

ACI2000R-120

2000

120

1

6824

12

Hot Box

20 AMP

NEMA 5-20p

Contact Information

Remote

362A1CInI1d0u0s0tr-i2a0l 8P/a2r4k0Driv8e67/1000 208-240

1

2957/3412

12

Lenoir City, TN37771

20 AMPPhone: (80N0E)M3A465-3-2006p2 [email protected]

Internal

Hot Box ACI1500-208/240 1300/1500 208-240

1 1 4436/5118

12

20 AMP Conwtawcwt N.IhnEofMot-rAbmoax5t.-ci2oo0nmp

Internal

3621 Industrial Park Drive

Lenoir CAitCyI,2T0N0037-270781/240 1733/2000 208-240

1

5914/6824

12

Phone: 800-346-3062 20 [email protected]

Internal

Contractors other than Hot Box are responsible for the1installation of the G.F.I. protected service and rewcewpwta.hcolets-.bWoxe.creocmommend that each

heater be on separate 20 amp circuits so in the event a circuit fails, all other circuits will reman powered. We recommend that all installations

be in accordance with the local and national codes.

62 Hubbell Utility Solutions

Heater and Heat Trace Tape

Standard Convection Heaters
Installation:
Instal1la. tioCno: ntractors other than Hot Box® are responsible for the installation of the G.F.I. protected service and receptacles (ref. UL 943, NEMA 3R). When multiple heaters are required it is recommended that each heater be on a separate 20 amp circuit. Separate circuits help provide redundancy in the event that one circuit fails. All installations to be in accordance with local and national codes.
2. Locate the aluminum heater plate(s) inside the enclosure and hang the heater(s) on the provided hangers.
3. Plug the heater into the ground fault circuit protected outlet. Note: The heater assembly may be installed on any vertical wall no closer than 2 inches from the adjacent box wall or seam.
Maintenance:
MaintPenerafnocrem: the following maintenance prior to installation and at least once per season, preferably before energizing the system, or immediately after any work has taken place on the piping system: Check to be sure heater power cord is free from mechanical or thermal damage (cuts or nicks in the cable insulation from utility knife, use of metal clamps, solder or overheating). To test heaters with adjustable thermostats, the thermostat should be turned clockwise until the heater activates and then reset to the minimum setting (40-45°F) by turning the knob counter-clockwise, after testing is completed. To test heaters with older pre-set thermostats, spray CO2 on the thermostat bulb to simulate cold temperature until the heater activates. Vacuum occasionally using standard vacuum attachments.
The heaters are intended to keep the equipment from freezing and are not to be used as a climate control device. RNuonten:inTghethheehaetaetresrsarfeorinetxetennddeeddtpoekreioedpstohfetiemqeuaipbmoveen4t 5fr°oFmwifllresehzoirntegnahnedaaterrelinfeo.t to be used as a
climate control device. Running the heaters for extended periods of time above 45°F will shorten Warnihnega!ter life.
Warning! – A ground fault circuit interrupting device shall be installed in the electrical supply circuit to the heater(s). Failure to do so may result in injury or death. The interior of this enclosure can a Warnidnagm! p location. WarniWnga!rning! – Hazard of severe shock, disconnect all power before servicing. WarniWnga!rning! – Do not block air flow in any way. Warning! – Avoid contact. The heater surface is HOT. For replacement heaters please contact your local Hot Box Representative.
hubbellpowersystems.com 63

Heat trace tape
Heat Trace Tape
FeaBtuerense: fits and Features:
Energy Efficient & Self-Regulating – The electrical resistance of the heat trace tape varies with temperature. As the process temperature drops the heat output increases; as the process temperature rises the heat output decreases.
Fast and Easy Installation – Single overlap cable and 3′ power cord and plug. 3′ poweFr rceoerdzeanPdrpoltuegction – Protects equipment from external temperatures as low as -30°F (-34.4°C).
Durable – Commercial grade design suitable for wet environments. Note: Heat trace tape does not respond to a drop in ambient temperature. It responds to abject cooling of surfaces such as tNheopteip:inHgeraistetrrsacaendtabpacekdfloowespnreovtenretisopnodnedvictoe. aItddrooepsinnoat mhebaiteanltontegmthpeeernattiruerec.aIbtlereastpoonnedtismteo. Tabhejetcatpe uses a secnosoolriyngbuolbf asnudrfaiscseeslfsruecghulaatsintgh,ehepaiptininggornilsyetrhsoasendsebcaticonksfloowf tappreevtheanttaiorenrdeqeuviirceed. tIot dwoarems nthoetchoeoaletd portions of thaelopnipgintgheriseenrstiraendcabbaclekfalotwopnreevteimnteio. nThdeevticaep.eSueseetsheaMseaninsteonryanbcuelbseacntiodnisfosretelfsrtienggu. lating, heating
only those sections of tape that are required to warm the cooled portions of the piping risers and backflow prevention device.
StanSdtaarndds:ards:
UL Listed CSA Certified for commercial/residential pipe freeze protection applications
Contact Hot Box if you do not see the heat trace tape you are looking for.
64 Hubbell Utility Solutions

Heater and Heat Trace Tape

Heat Trace Tape
Installation:
1. Contractors other than Hot Box® are responsible for the installation of the G.F.I. protected service and receptacles (ref. UL 943, NEMA 3R). When multiple heaters are required it is recommended that each heater be on a separate 15 amp circuit. Separate circuits help provide redundancy in the event that one circuit fails. All installations to be in accordance with the local and national codes.
2. Wrap heat trace tape in a spiral or straight line (depending on length of the heat tape) about the pipe risers and backflow device. Avoid overlapping the heat tape.
3. Secure heat trace tape on 12″ centers using only glass cloth tape or plastic cable ties. Restrain the plug end of the cord to provide proper strain relief.
4. Pipe insulation is not a requirement. If insulating the pipe, use only a fire resistant thermal insulation, such as fiberglass pipe wrap.
5. Plug cable into 120V ground fault circuit protected outlet.
Maintenance:
Perform the following maintenance prior to installation and at least once per season, preferably before energizing the system, or immediately after any work has taken place on the piping system: Check to be sure heating cable is free from mechanical or thermal damage (cuts or nicks in
the cable insulation from utility knife, use of metal clamps, solder or overheating). Use Megohmmeter to test each circuit (see below).
Megohmmeter Testing Procedure (Use only 2500VDC megohmmeter for this test):
Check insulation resistance between each lead of the heating cable and the round ground lug on the power cord plug.
Perform the test by placing one lead of the megohmmeter on the round ground lug and the other on one of the rectangular power lugs. You should read 1000 megohms minimum.
Perform the test again by checking the opposite rectangular power lug. Again the reading should be 1000 megohms minimum.
Note: If you read less than 1000 megohms on either lead, the cable needs to be replaced. Do not attempt to repair the unit. Replace with new product. The megohm readings along with the test date should be recorded.
Warning! – A ground fault circuit interrupting device shall be installed in the electrical supply circuit to the heater(s). Failure to do so may result in injury or death. The interior of this enclosure can be a damp location.
Warning! – Hazard of severe shock, disconnect all power before servicing.
Warning! – Avoid contact. The heater surface is HOT.
For replacement heaters please contact your local Hot Box Representative.
hubbellpowersystems.com 65

Hot Box Order Form
66 Hubbell Utility Solutions

Typical Winterization
hubbellpowersystems.com 67

Order Form & Typical Winterization

Typical Installation-Single
68 Hubbell Utility Solutions

Typical Installation Examples

Typical Installation-Single w/ Meter
hubbellpowersystems.com 69

Typical Installation-Dual
70 Hubbell Utility Solutions

Typical Installation Examples

Typical Installation-Tandem
hubbellpowersystems.com 71

BACKFLOW PREVENTION ASSEMBLY ENCLOSURE SPECIFICATION – DURA FOLD®

GENERAL
1.1 WORK INCLUDED
A. Provide and install manufactured backflow prevention assembly enclosure.
1.2 QUALITY ASSURANCE
A. Qualifications: The backflow prevention assembly enclosure manufacturer shall be a company specializing in the manufacture of backflow prevention assembly enclosures with at least 29 years of successful experience designing and selling enclosures to various customers in different climatic regions.
1.3 STORAGE AND HANDLING
A. Store products in shipping containers and maintain in dry place until installation.
1.4 ACCEPTABLE MANUFACTURERS
A. Hot Box® or Engineer approved equal.
1.5 REFERENCES
A. ASTM B209.
B. ASTM B221.
C. ASSE 1060 – Performance Requirements for Outdoor Enclosures for Backflow Prevention assemblies.
PRODUCTS
2.1 DURA FOLD® ENCLOSURES
A. Dura Fold® Enclosures ship assembled to allow quick installation by securing to the concrete pad with the supplied anchor pads and wedge anchors. The design includes hinged walls, as well as front and top lids, to provide easy access. Also the front wall is easily removed to provide unobstructed access for equipment testing and maintenance after installation.
B. Drain ports are sized for full port backflow discharge and are designed for a one way operation allowing backflow discharge but not allowing wind, debris and small animals to enter the enclosure.
C. Standard enclosures shall be designed to support a minimum vertical load of 100 lb/sf.
D. Standard enclosures shall be designed to support wind speeds up to 80 mph.
E. Standard enclosures are ASSE 1060 certified.
F. Custom Dura Fold Enclosures are designed and constructed in the same manner as standard certified enclosures, but have not been lab tested and listed by ASSE.
2.2 MATERIALS OF FABRICATION
A. Aluminum sheeting shall be 3003 aluminum

(.050″/16 gauge), stucco embossed finish and shall meet ASTM B209. Stucco embossed finish reduces the glare and helps hide surface scratches or imperfections received in the field.

B. Bracing shall be 6063-T52 aluminum and shall meet ASTM B221

C. No wood or particle board should be used in the construction of the enclosure.

D. Anchor pads shall be galvanized steel. 3/8-16 unc x 2 ¾ long zinc plated wedge anchors are supplied.

E. Insulation shall be approximately 1.5″ unicellular, non-wicking, polyisocyanate foam sprayed in place that forms a monolithic bond between the aluminum bracing and aluminum sheeting.

F. The Insulation shall have the following properties:

· R-Value: · Dimensional Stability: · Compressive Strength: · Flame point: · Water absorption: · Porosity:

10 <2% linear change 51 psi 325 degrees .037 psf
91%

3.1 HEATING EQUIPMENT (ASSE 1060 Class I-Required; ASSE 1060 Class II- Optional)
A. Heating equipment will protect the piping and equipment from exterior temperatures to -30F. ETL listed thermostatically controlled wall mounted air forced heaters or UL listed self regulating cable(s) shall be furnished and designed by the manufacturer of the enclosure to maintain the equipment at +40F, In accordance with ASSE 1060 1.2.2.1.
B. Heating equipment shall be wall mounted to the supplied heater plates and a minimum 8″ above the slab unless it is UL or ETL certified and NEC approved for submersion.
C. Power source shall be protected with a GFI receptacle, U.L. 943, NEMA 3R. Mounted a minimum of 8″ from the bottom of the receptacle to the top of the slab.
D. Separate 20 amp circuits are recommended for each heater, so in the event a circuit fails all other circuits will remain powered. Installations must be in accordance with the local and national codes.
E. The heaters shall be ETL listed for wet/damp locations.

4.1 RECOMMENDED SLAB SIZE & INSTALLATION
A. The recommended slab size shall be 12″ larger than the interior dimensions of the enclosure and a minimum of 4″ thick.
B. The enclosure shall be assembled per the manufacturer’s instructions provided with the enclosure.

72 Hubbell Utility Solutions

BACKFLOW PREVENTION ASSEMBLY ENCLOSURE SPECIFICATION – MODULAR

Product Specifications

GENERAL
1.1 WORK INCLUDED
A. Provide and install manufactured backflow prevention assembly enclosure.
1.2 QUALITY ASSURANCE
A. Qualifications: The backflow prevention assembly enclosure manufacturer shall be a company specializing in the manufacture of backflow prevention assembly enclosures with at least 30 years of successful experience designing and selling enclosures to various customers in different climatic regions.
1.3 STORAGE AND HANDLING
A. Store products in shipping containers and maintain in dry place until installation.
1.4 ACCEPTABLE MANUFACTURERS
A. Hot Box® or Engineer approved equal.
1.5 REFERENCES
A. ASSE 1060-Performance Requirements for Outdoor Enclosures for Backflow Prevention assemblies.
B. ASTM B209.
PRODUCTS
2.1 MODULAR ENCLOSURE
A. The roof, walls and access panels shall be constructed of 3003 aluminum (.050/18 gauge), stucco embossed finish to reduces glare, finger prints and help hide surface scratches. Insulation shall be 1.5″ (9.0 “R” value) thick.
B. The wall panels shall be securely fastened together with self-tapping screws.
C. The walls of the enclosure shall be securely mounted to the concrete slab with interior concrete anchors.
D. The roof panel shall be securely fastened to the walls with self-tapping screws on the outside and mounting clips on the inside.
E. The access panels shall have a two point locking system with pad lockable handle and be completely removable.
F. Drain ports shall be sized for full port backflow discharge and designed for a one way operation allowing backflow discharge but not allowing wind, debris and small animals to enter the enclosure.
2.2 MATERIALS OF FABRICATION
A. Aluminum sheeting shall be 3003 aluminum (.050/16 gauge), stucco embossed finish and shall meet ASTM B209. Stucco embossed finish reduces the glare, finger prints and helps hide any surface scratches or imperfections received in the field.
B. Insulation shall be 1.5″ thick polyisocyanurate foam laminated to a glass fiber reinforced facer on each side.

C. The Insulation shall have the following properties:

· R-Value: · Dimensional Stability:
· Compressive Strength: · Water absorption: · Product Density:
· Flame spread · Service Temperature

9 < 2% linear change, ASTM D 2126 20psi, ASTM D1621 < 1%, ASTM C209 Nominal 2.0 pcf, ASTM D1622 25, ASTM E 84 -100°F to 250°F

D. No wood or particle board to be used in the construction.

2.3 HEATING EQUIPMENT (ASSE 1060 Class I-Required; ASSE 1060 Class II- Optional)

A. Heating equipment shall protect the piping and equipment from exterior temperatures to -30°F. ETL listed thermostatically controlled wall mounted air forced heaters shall be furnished and designed by the enclosure manufacturer to maintain the equipment at +40°F, in accordance with ASSE 1060 1.2.2.1.

B. Heating equipment shall be wall mounted to the supplied heater plates and a minimum of 8″ above the slab unless it is UL or ETL certified and NEC approved for submersion.

C. Power source shall be protected with a GFI receptacle, U.L. 943, NEMA.3R. Mounted a minimum of 8″ from the bottom of the receptacle to the top of the slab.

D. Separate 20 amp circuits are recommended for each heater, so in the event a circuit fails all other circuits will remain powered. Installations must be in accordance with the local and national codes.

E. The heaters shall be ETL listed for wet/damp locations.

2.4 INSTALLATION HARDWARE
A. Threaded fasteners shall be stainless steel and provided by the manufacturer.
B. Concrete anchors shall be wedge type anchors and provided by the manufacturer.
C. Masonry drill bit & Hex nut driver for threaded fasteners shall be provided by the manufacturer.

2.5 RECOMMENDED SLAB SIZE & INSTALLATION
A. The recommended slab size shall be 9″ larger than the enclosures exterior dimensions and a minimum of 4″ thick.
B. The enclosure shall be assembled and mounted to concrete pad per the manufactures instructions provided with the enclosure.
C. Enclosure shall be assembled and mounted to concrete pad in such a way that it will remain locked and secured to the pad even if outside screws are removed.

hubbellpowersystems.com 73

BACKFLOW PREVENTION ASSEMBLY ENCLOSURE SPECIFICATION-SECTIONAL ALUMINUM

GENERAL
1.1 WORK INCLUDED
A. Provide and install manufactured backflow prevention assembly enclosure.
1.2 QUALITY ASSURANCE
A. Qualifications: The backflow prevention assembly enclosure manufacturer shall be a company specializing in the manufacture of backflow prevention assembly enclosures with at least 29 years of successful experience designing and selling enclosures to various customers in different climatic regions.
1.3 STORAGE AND HANDLING
A. Store products in shipping containers and maintain in dry place until installation.
1.4 ACCEPTABLE MANUFACTURERS
A. Hot Box® or Engineer approved equal.
1.5 REFERENCES
A. ASTM B209.
B. ASTM B221.
C. ASSE 1060 – Performance Requirements for Outdoor Enclosures for Backflow Prevention assemblies.
PRODUCTS
2.1 SECTIONALIZED ALUMINUM ENCLOSURES
A. Sectionalized enclosures are factory assembled with tongue and grooved sections that slide together and are then secured to the concrete pad with the supplied anchor pads and wedge anchors.
B. Access panels have a four point locking system with pad lockable handle and are completely removable.
C. Drain ports are sized for full port backflow discharge and are designed for a one way operation allowing backflow discharge but not allowing wind, debris and small animals to enter the enclosure.
D. Standard enclosures shall be designed to support a minimum vertical load of 100lb/sf.
E. Standard enclosures up to 36″W x 105″L x 64″H shall be designed to support wind speeds up to 120 mph, all larger sizes shall be designed to support wind speeds up to 80 mph.
F. Standard enclosures are ASSE 1060 certified.
G. Custom enclosures are designed and constructed in the same manner as standard certified enclosures, but have not been lab tested and listed by ASSE.

2.2 MATERIALS OF FABRICATION

A. Aluminum sheeting shall be 3003 aluminum (.050/16 gauge), stucco embossed finish and shall meet ASTM B209. Stucco embossed finish reduces the glare and helps hide any surface scratches or imperfections received in the field.

B. Bracing shall be 6063-T52 aluminum and shall meet ASTM B221.

C. No wood or particle board should be used in the construction of the enclosure.

D. Anchor pads shall be galvanized steel. 3/8-16 unc x 2 ¾ long zinc plated wedge anchors are supplied.

E. Insulation shall be approximately 1.5″ unicellular, non-wicking, polyisocyanate foam sprayed in place that forms a monolithic bond between the aluminum bracing and aluminum sheeting.

F. The Insulation shall have the following properties:

· R-Value: · Dimensional Stability: · Compressive Strength: · Flame point: · Water absorption: · Porosity:

10 <2% linear change 51 psi 325 degrees .037 psf
91%

3.1 HEATING EQUIPMENT (ASSE 1060 Class I-Required; ASSE 1060 Class II- Optional)
A. Heating equipment will protect the piping and equipment from exterior temperatures to -30F. ETL listed thermostatically controlled wall mounted air forced heaters shall be furnished and designed by the manufacturer of the enclosure to maintain the equipment at +40F, In accordance with ASSE 1060 1.2.2.1.
B. Heating equipment shall be wall mounted to the supplied heater plates and a minimum of 8″ above the slab unless it is UL or ETL certified and NEC approved for submersion.
C. Power source shall be protected with a GFI receptacle, U.L. 943, NEMA 3R. Mounted a minimum of 8″ from the bottom of the receptacle to the top of the slab.
D. Separate 20 amp circuits are recommended for each heater, so in the event a circuit fails all other circuits will remain powered. Installations must be in accordance with the local and national codes.
E. The heaters shall be ETL listed for wet/damp locations.

4.1 RECOMMENDED SLAB SIZE & INSTALLATION
A. The recommended slab size shall be 12″ larger than the interior dimensions of the enclosure and a minimum of 4″ thick.
B. The enclosure shall be assembled per the manufacturer’s instructions provided with the enclosure.

74 Hubbell Utility Solutions

Product Specifications

BACKFLOW PREVENTION ASSEMBLY ENCLOSURE SPECIFICATIONS – ALUMINUM DROP OVER

GENERAL
1.1 WORK INCLUDED
A. Provide and install manufactured backflow prevention assembly enclosure.
1.2 QUALITY ASSURANCE
A. Qualifications: The backflow prevention assembly enclosure manufacturer shall be a company specializing in the manufacture of backflow prevention assembly enclosures with at least 30 years of successful experience designing and selling enclosures to various customers in different climatic regions.
1.3 STORAGE AND HANDLING
A. Store products in shipping containers and maintain in dry place until installation.
1.4 ACCEPTABLE MANUFACTURERS
A. Hot Box® or Engineer approved equal.
1.5 REFERENCES
A. ASSE 1060-Performance Requirements for Outdoor Enclosures for Backflow Prevention assemblies.
B. ASTM B209.
PRODUCTS
2.1 DROP OVER ENCLOSURE
A. Enclosure shall ship fully assembled to allow for quick installation by securing to the concrete pad with the supplied anchor brackets.
B. Enclosure shall be lockable.
C. Drain ports are sized for full port backflow discharge and are designed for a one way operation allowing backflow discharge but not allowing wind, debris and small animals to enter the enclosure.
2.2 MATERIALS OF FABRICATION
A. Aluminum sheeting shall be 3003 aluminum (.050/16 gauge), stucco embossed finish and shall meet ASTM
B209. Stucco embossed finish reduces the glare, finger prints and helps hide any surface scratches or imperfections received in the field.
B. Insulation shall be 1.5″ thick polyisocyanurate foam laminated to a glass fiber reinforced facer on each side.

C. The Insulation shall have the following properties:

· R-Value: · Dimensional Stability:
· Compressive Strength: · Water absorption: · Product Density Nominal: · Flame spread: · Service Temperature:

9 < 2% linear change, ASTM D 2126 20psi, ASTM D1621 < 1%, ASTM C209 2.0 pcf, ASTM D1622 25, ASTM E 84 -100°F to 250°F

3.1 HEATING EQUIPMENT (ASSE 1060 Class I-Required; ASSE 1060 Class II- Optional)
A. Heating equipment shall protect the piping and equipment from exterior temperatures to -30°F. UL listed self regulating cable(s) shall be furnished to maintain the equipment at +40°F, in accordance with ASSE 1060 1.2.2.1.
B. Power source shall be protected with a GFI receptacle, U.L. 943, NEMA.3R. Mounted a minimum of 8″ from the bottom of the receptacle to the top of the slab.
C. Separate 15 amp circuits are recommended, so in the event a circuit fails all other circuits will remain powered.
Installations must be in accordance with the local and national codes.
D. The heaters shall be UL or ETL listed for wet/ damp locations.

4.1 RECOMMENDED SLAB SIZE & INSTALLATION
A. The recommended slab size shall be 9″ larger than the enclosures exterior dimensions and a minimum of 4″ thick.
B. The enclosure shall be assembled and mounted to concrete pad per the manufactures instructions provided with the enclosure.
C. The enclosure shall not require assembly.

hubbellpowersystems.com 75

BACKFLOW PREVENTION ASSEMBLY ENCLOSURE SPECIFICATIONS – HDPE DROP OVER

GENERAL
1.1 WORK INCLUDED
A. Provide and install manufactured backflow prevention assembly enclosure.
1.2 QUALITY ASSURANCE
A. Qualifications: The backflow prevention assembly enclosure manufacturer shall be a company specializing in the manufacture of backflow prevention assembly enclosures with at least 30 years of successful experience designing and selling enclosures to various customers in different climatic regions.
1.3 STORAGE AND HANDLING
A. Store products in shipping containers and maintain in dry place until installation.
1.4 ACCEPTABLE MANUFACTURERS
A. Hot Box® or Engineer approved equal.
1.5 REFERENCES
A. ASSE 1060-Performance Requirements for Outdoor Enclosures for Backflow Prevention assemblies.
PRODUCTS
2.1 DROP OVER ENCLOSURE
A. Enclosure shall ship fully assembled to allow for quick installation by securing to the concrete pad with the supplied anchor brackets.
B. Enclosure shall be lockable.
C. Drain ports are sized for full port backflow discharge and are designed for a one way operation allowing backflow discharge but not allowing wind, debris and small animals to enter the enclosure.
2.2 MATERIALS OF FABRICATION
· A. Plastic shall be 1/4″ UV stabilized HDPE structural foam (beige or green color). No wood or particle board
· to be used in the construction. · B. Insulation shall be 2″ thick (R8), molded
expanded polystyrene and is not affected by heat or cold.
2.3 HEATING EQUIPMENT (ASSE 1060 Class I-Required; ASSE 1060 Class II- Optional)
A. Heating equipment shall protect the piping and equipment from exterior temperatures to -30°F. UL listed self regulating cable(s) shall be furnished to maintain the equipment at +40°F, in accordance with ASSE 1060 1.2.2.1.

B. Power source shall be protected with a GFI receptacle, U.L. 943, NEMA.3R. Mounted a minimum of 8″ from the bottom of the receptacle to the top of the slab.
C. Separate 15 amp circuits are recommended, so in the event a circuit fails all other circuits will remain powered. Installations must be in accordance with the local and national codes.
D. The heaters shall be UL or ETL listed for wet/ damp locations.
2.4 RECOMMENDED SLAB SIZE & INSTALLATION
A. The recommended slab size shall be 4″ larger than the enclosures exterior dimensions.
B. The enclosure shall be assembled and mounted to concrete pad per the manufactures instructions provided with the enclosure.
C. The enclosure shall not require assembly.

76 Hubbell Utility Solutions

Product Specifications

BACKFLOW PREVENTION ASSEMBLY ENCLOSURE SPECIFICATION-DESIGNER SERIESTM

GENERAL
1.1 WORK INCLUDED
A. Provide and install manufactured backflow prevention assembly enclosure.
1.2 QUALITY ASSURANCE
A. Qualifications: The backflow prevention assembly enclosure manufacturer shall be a company specializing in the manufacture of backflow prevention assembly enclosures with at least 29 years of successful experience designing and selling enclosures to various customers in different climatic regions.
1.3 STORAGE AND HANDLING
A. Store products in shipping containers and maintain in dry place until installation.
1.4 ACCEPTABLE MANUFACTURERS
A. Hot Box® or Engineer approved equal.
1.5 REFERENCES
A. ASSE 1060 – Performance Requirements for Outdoor Enclosures for Backflow Prevention assemblies.
PRODUCTS
2.1 DESIGNER SERIESTM ENCLOSURES
A. Enclosures shall have front and back hinged doors that are removable for full access to both sides of the equipment for maintenance and testing.
B. Enclosures shall have a removable hinged top with gas shocks to support and secure the lid in an upright position for full access to the top of the equipment for maintenance and testing.
C. Doors shall be secured from the interior of the enclosure and shall have no exterior handles or lock exposed to the elements.
D. The top is lockable to deter unauthorized entry, theft and vandalism.
E. Anchoring is supplied to secure to the concrete pad.
F. Drain ports are sized for full port backflow discharge and are designed for a one way operation allowing backflow discharge but not allowing wind, debris and small animals to enter the enclosure.
G. Standard enclosures shall be designed to support a minimum vertical load of 100 lb/sf.
H. Standard enclosures shall be designed to support wind speeds up to 120 mph.
I. Standard enclosures shall be ASSE 1060 certified.

2.2 MATERIALS OF FABRICATION

A. Fiberglass is minimum of 1/8″ thick Thixotropic polyester resin reinforced with fiberglass strand. A smooth yacht quality finish, protected with UV inhibited isophthalic polyester gel coat.

B. No wood or particle board should be used in the construction of the enclosure.

C. Anchor pads shall be galvanized steel. 3/8-16 unc x 2 ¾ long zinc plated wedge anchors and drill bit are supplied.

D. Insulation shall be 1.5″ unicellular, non-wicking, polyisocyanate foam sprayed in place to form a monolithic bond to the fiberglass and is not affected by heat or cold. No clips or fasteners shall be used.

E. The Insulation shall have the following properties:

· R-Value: · Dimensional Stability: · Compressive Strength: · Flame point: · Water absorption: · Porosity:

10 <2% linear change 51 psi 325 degrees .037 psf
91%

3.1 HEATING EQUIPMENT (ASSE 1060 Class I-Required; ASSE 1060 Class II- Optional)
A. Heating equipment will protect the piping and equipment from exterior temperatures to -30F. ETL listed thermostatically controlled wall mounted air forced heaters shall be furnished and designed by the manufacturer of the enclosure to maintain the equipment at +40F, In accordance with ASSE 1060 1.2.2.1.
B. Heating equipment shall be wall mounted to the supplied heater plates and a minimum 8″ above the slab unless it is UL or ETL certified and NEC approved for submersion.
C. Power source shall be protected with a GFI receptacle, U.L. 943, NEMA 3R. Mounted a minimum of 8″ from the bottom of the receptacle to the top of the slab.
D. Separate 20 amp circuits are recommended for each heater, so in the event a circuit fails all other circuits will remain powered. Installations must be in accordance with the local and national codes.
E. The heaters shall be ETL listed for wet/damp locations.

4.1 RECOMMENDED SLAB SIZE & INSTALLATION
A. The recommended slab size shall be 12″ larger than the interior dimensions of the enclosure and a minimum of 4″ thick.
B. The enclosure shall be assembled per the manufacturer’s instructions provided with the enclosure.

hubbellpowersystems.com 77

BACKFLOW PREVENTION ASSEMBLY ENCLOSURE SPECIFICATION – FIBERGLASS

GENERAL
1.1 WORK INCLUDED
A. Provide and install manufactured backflow prevention assembly enclosure.
1.2 QUALITY ASSURANCE
A. Qualifications: The backflow prevention assembly enclosure manufacturer shall be a company specializing in the manufacture of backflow prevention assembly enclosures with at least 29 years of successful experience designing and selling enclosures to various customers in different climatic regions.
1.3 STORAGE AND HANDLING
A. Store products in shipping containers and maintain in dry place until installation.
1.4 ACCEPTABLE MANUFACTURERS
A. Hot Box® or Engineer approved equal.
1.5 REFERENCES
A. ASTM B209.
B. ASTM B221.
C. ASSE 1060 – Performance Requirements for Outdoor Enclosures for Backflow Prevention assemblies.
PRODUCTS
2.1 FIBERGLASS ENCLOSURES
A. Available in Drop over, Flip top, Vent Guard, Valve Cover & Roks.
B. All fiberglass enclosures are lockable.
C. Anchoring is supplied to secure to the concrete pad.
D. Drain ports are sized for full port backflow discharge and are designed for a one way operation allowing backflow discharge but not allowing wind, debris and small animals to enter the enclosure.
E. Standard enclosures shall be designed to support a minimum vertical load of 100 lb/sf.
F. Standard enclosures shall be designed to support wind speeds up to 120 mph.
G. Standard enclosures are ASSE 1060 certified.
2.2 MATERIALS OF FABRICATION
A. Fiberglass is minimum of 1/8″ thick Thixotropic polyester resin reinforced with fiberglass strand. A smooth yacht quality finish, protected with UV inhibited isophthalic polyester gel coat.
B. Non molded products will utilize an Industrial exterior texture.

C. No wood or particle board should be used in the construction of the enclosure.

D. Insulation shall be 1″-1.5″ unicellular, non-wicking, polyisocyanate foam frothed or sprayed in place.

E. The Insulation shall have the following properties:

· R-Value: · Dimensional Stability: · Compressive Strength: · Flame point: · Water absorption:
· Porosity:

8 <2% linear change 51 psi 325 degrees .037 psf
91%

3.1 HEATING EQUIPMENT (ASSE 1060 Class I-Required; ASSE 1060 Class II- Optional)
A. Heating equipment will protect the piping and equipment from exterior temperatures to -30F. ETL listed thermostatically controlled wall mounted air forced heaters or UL listed self regulating cable(s) shall be furnished and designed by the manufacturer of the enclosure to maintain the equipment at +40F, In accordance with ASSE 1060 1.2.2.1.
B. Heating equipment shall be wall mounted to the supplied heater plates and a minimum 8″ above the slab unless it is UL or ETL certified and NEC approved for submersion.
C. Power source shall be protected with a GFI receptacle, U.L. 943, NEMA 3R. Mounted a minimum of 8″ from the bottom of the receptacle to the top of the slab.
D. Separate 20 amp circuits are recommended for each heater, so in the event a circuit fails all other circuits will remain powered. Installations must be in accordance with the local and national codes.
E. The heaters shall be ETL listed for wet/damp locations.

4.1 RECOMMENDED SLAB SIZE & INSTALLATION
A. The recommended slab size shall be 9″ larger than the exterior dimensions of the enclosure and a minimum of 4″ thick.
B. The enclosure shall be assembled per the manufacturer’s instructions provided with the enclosure.

78 Hubbell Utility Solutions

Terms & Conditions

HUBBELL LENOIR CITY, INC. ARMORCAST PRODUCTS COMPANY INC. TERMS & CONDITIONS OF SALES
Hubbell Lenoir City, Inc. and its affiliate to specifically include Armorcast Products Company Inc. (hereinafter called Seller) hereby gives notice of its exception to any different or additional terms and conditions other than as stated herein. All sales are expressly made conditional on Buyer’s assent to the following terms and conditions. Buyer’s acceptance of the provisions of Seller’s terms and conditions as recited herein shall be conclusively presumed upon Buyer’s receipt of the goods, or if no written objection is received by Seller within fifteen (15) days from the date on Seller’s order acknowledgment, whichever event shall first occur. These terms and conditions constitute the entire agreement between Seller and Buyer, and supersede other communications between the two parties, whether written or oral.
PRICING Refer to appropriate Price Schedule, unless otherwise quoted.
TERMS Seller’s payment terms are net 30 days. Invoices will be dated the day of shipment. A service charge of 1-1/2% per month or, if such rate exceeds the maximum lawful rate, the maximum lawful rate shall be assessed on all past due accounts and shall be payable on demand.
QUOTATIONS Unless otherwise stated in writing, Seller’s quotations are subject to acceptance by the Buyer within thirty (30) days from the date of issue.
SALES AND SIMILAR TAXES Seller’s prices do not include any sales, use, excise or similar taxes. Consequently, in addition to the price specified herein, the amount of any present or future sales, use, excise or other similar tax applicable to the sale or use of the goods hereunder, shall be paid by the Buyer, or in lieu thereof the Buyer shall provide Seller with a tax exemption certificate acceptable to the taxing authorities.
ACCEPTANCE OF ORDERS All orders are subject to acceptance by Seller at its principal office located at 3621 Industrial Park Drive, Lenoir City, TN, 37771 USA, for Hubbell Lenoir City, Inc and 9140 Lurline Avenue, Chatsworth, CA, 91311 USA for Armorcast Products Company Inc and Buyer’s assent to these Terms and Conditions of Sale. Any other terms proposed by Buyer are rejected unless expressly accepted in writing. Acceptance of any order is subject to the product’s availability and the Seller’s ability to deliver. Orders will be billed at prices in effect at the time of shipment unless otherwise agreed. Unless otherwise stated in writing, Seller reserves the right to ship plus or minus 10% of specified quality for special products made to order.
SALES BY AGENTS Sales by agents or through overseas representatives shall be at prices, terms and conditions of sale specified by Seller. All invoices will be issued by and payment remitted to Seller.
DELAY Seller will use reasonable efforts to meet shipment or delivery dates specified by Seller, but such dates are estimates only. Seller shall in no event be liable for any delay or non-delivery if such delay or non-delivery is caused directly or indirectly by Acts of God, fire, flood, strike or lockout or other labor dispute, accident, civil commotion, riot, war, governmental regulation or order, whether or not it later proves to be invalid, or from any other cause or causes (whether or not similar to any of the foregoing) beyond Seller ‘s control. In no case will Seller be liable for loss of profits or any special or consequential damages on account of any delay in delivery or non- delivery whether or not excused hereunder.
SHIPPING DEFERMENT Buyer requests for shipping deferment must be approved by Seller and are subject to price negotiation.
Effective 01/21/2022
hubbellpowersystems.com 79

Terms & Conditions

LIMITED WARRANTY Material: Seller warrants all products sold by it to be merchantable (as such term is defined in the Uniform Commercial Code) and to be free from defects in material and workmanship for a period of