HUBBELL RWL1 Ratio Wall LED Light Installation Guide

June 9, 2024
Hubbell

HUBBELL RWL1 Ratio Wall LED Light

HUBBELL RWL1 Ratio Wall LED Light-fig1

READ THOROUGHLY BEFORE INSTALLATION

  • WARNING! Fixtures must be grounded and installed in accordance with the National Electrical Code and all local codes. Failure to do so may increase the RISK OF
  • PERSONAL INJURY, PROPERTY DAMAGE, FIRE AND DEATH. Install and use so fixture failures do not cause a hazard and use only in environments for which the product is specifically marked.
    • WARNING! This product contains chemicals known to the State of California to cause cancer, birth defects, and/or other reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.
  • CAUTION! Follow ALL luminaire recommendations, product markings, instructions, restrictions and warnings regarding luminaire operation and burning position. Luminaire label shows electrical and environmental requirements and restrictions.
  • All electrical work must be done by a qualified electrician.
  • Turn off electric power to all affected circuits and allow to cool before servicing.
  • A regularly scheduled maintenance program should be established to retain optimum light output and reduce heat retention. Dusting with a soft, clean, dry cloth is normally sufficient for the optical system. Any accumulation of dust or dirt should be removed regularly.
  • Carefully read these instructions before installing product. If you do not understand these instructions, before starting any work, contact your distributor or Lightingtechsupport@currentlighting.com or 864-678-1000
  • Give instructions to facility owner/manager for future reference.

NOTE:
DO NOT OPEN THIS PRODUCT UNLESS INSTRUCTED BY STEPS INCLUDED IN THESE INSTRUCTIONS OR BY CURRENT LIGHTING TECHNICAL SUPPORT PERSONNEL. FIXTURE HAS BEEN DESIGNED WITH EASY TO INSTALL MOUNTING BRACKETS.

TOOLS REQUIRED

  • 1/8″ HEX KEY WRENCH
  • PHILLIPS STYLE SCREWDRIVER
  • DRILL (IF JUNCTION BOX IS NOT PRESENT AND MOUNTING BRACKET IS MOUNTED DIRECT TO WALL) ANY ADDITIONAL TOOLS NEEDED
  • FOR APPROPRIATE WALL FASTENERS

PARTS REQUIRED:
(SUPPLIED BY OTHERS)
SILICONE CAULK, 1/4” WALL ANCHORS AND FASTENERS APPROPRIATE FOR WALL CONSTRUCTION TYPE

STEP I – MOUNTING PREPARATION

POWER MUST BE OFF.
(WIRING MUST BE PERFORMED BY A QUALIFIED ELECTRICIAN)

  • Remove fixture mounting bracket (A) from fixture by loosening the hex set screws (B).
  • Remove paper backing from gasket (C) and apply to mounting bracket (A).
  • Align holes in bracket to your matching j-box holes.
  • Secure mounting bracket to your j-box.
  • If no junction box is available, mounting plate must be securely anchored to wall (hardware NOT PROVIDED).
  • Apply caulking sealant (supplied by others) around the top and two sides of the bracket where it meets the wall .

STEP II WIRING

  • Connect service leads to fixture power leads according to local and National Electric Codes.
  • For direct wire connections, connect ground wire to the green wire. Connect black to line and white to neutral then push connections back inside J-box (See FIG. 1 for details.)

STEP III FIXTURE MOUNTING

  • Hold fixture (D) and slide over mounting bracket (A) until fixture sits flat against wall.
  • Tighten the two (2) set screws (B) securely to capture the mounting bracket (A).
  • Check to ensure secure mount.
    Energize product.

BATTERY BACK-UP (BBU) INFORMATION

FOR UNITS EQUIPPED WITH BBU:

  • Must be charged for 24 hours before use. *Once A/C power is supplied to fixture, emergency BBU will remain active, even if A/C power is removed.
  • Refer to FIG. 2 for BBU operating status and alert codes.
  • BBU units are only equipped for 120V or 277V input.
  • Maximum mounting height: 11.8 ft.

IMPORTANT SAFEGUARDS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

  • Do not mount near gas or electric heaters.
  • Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
  • The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
  • Do not use this equipment for other than intended use.

HUBBELL RWL1 Ratio Wall LED Light-fig2
READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

OPERATING STATUS INDICATOR

OFF AC OFF
GREEN ON = AC ON
BLINKING GREEN= TEST IN PROGRESs

SERVICE ALERT CODES

1 RED BLINK = BATTERY DIS CONNECTED
2 RED BLINKS BATTERY FAULT
3 RED BLINKS = CHARGER FAULT
4 RED BLINKS = LED DRIVER FAULT
5 RED BLINKS = LAMP FAULT
10 RED BLINKS = LOAD LEARN FAILURE
RED/GREEN ALTERNA TING = LOAD LEARN IN PROGRESS

Current Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • Phone: 864-678-1000
©2022 HLI Solutions, Inc. All Rights Reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under labarotory conditions.

www.beaconproducts.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Hubbell User Manuals

Related Manuals