TECHNICAL DATA

Power supply 2x AA 1,5  VOLT alkaline
Average life of the battery 1 year
Degree of protection IP 20
Frequency 433.092 MHz
Operating temp. 3 – 50 °C
Operating pressure MAX: 10  bar
Plastic materials >ABS< – >PC<

PBT GF20%<
POM<
TPE<
PA66 FG30%<

Water pressure table

Bar 0,5 1 2 2,5 3 4 5
l/min 12 17 23 25 27 30 33

GENERAL INFORMATION

Claber 8486 Tempo Select - icon 1

NO FROST| NOT SUITABLE
FOR CHILDREN| OUTDOOR

Claber 8486 Tempo Select - icon 2Claber 8486
Tempo Select 1

Always keep the cover closed

Claber 8486 Tempo Select - Tenere sempre

Use water from the mains tap or filter the water before using it

FILTERED WATER

DESCRIPTION

Claber 8486 Tempo Select - DESCRIPTION

  1. 3/4″ tap connector F with screw collar

  2. Inspect able and washable filter

  3. Protective cover

  4. 4a. 3/4” M threaded connector
    4b. click system Quick

  5. Display

  6. Run time setting key

  7. Display of watering frequency

  8. Display of watering run time

  9. Start watering Manual

  10. Frequency setting key

  11. Start programmed watering

BATTERY REPLACEMENT

Claber 8486 Tempo Select - BATTERY REPLACEMENT

battery almost flat

BATTERIES NOT INCLUDED

Only use new 1,5V Alkaline AA (LR6) batteries, with an expiry date exceeding one year and that have never been used. Replace the batteries at the beginning of each season. When the batteries are completely flat, the control unit automatically stops its functions and closes the valves. Replace the batteries within 2 minutes of removing them, otherwise programming will be lost. Every time you remove the batteries, the timer resets the current time to the time the  batteries are inserted. Never replace the batteries during irrigation, otherwise the water will continue to flow at the end of the cycle.

RAIN SENSOR (optional)

Claber 8486 Tempo Select - RAIN SENSOR

Remove the bridge connector on the timer (1). Insert the Rain Sensor connector (2A).
Irrigation will not start if the container is full (at least 5 mm of rainfall). The irrigation cycle in progress will stop within 1 minute of the container being filled. Alternatively, insert the Rain Sensor RF interface (2B). The irrigation cycle will  not start if the container is full. The irrigation cycle in progress will stop within 5 minutes of the container being filled.

INSTALLATION

Claber 8486 Tempo Select 3

Do not install the water timer inside valve boxes, below ground level or indoors. Do not use the water timer with operating pressures lower than 0.5 bar (7.3 psi) or higher than 10 bar (145psi).

MAINTENANCE

Claber 8486 Tempo Select - ENTRETIEN

CONDITIONS OF GUARANTEE

This device is guaranteed for 3 years from the date of purchase as indicated by the invoice, bill or till receipt issued at the time of the transaction, which must be kept. Claber guarantees that the product is free of material or manufacturing defects.
Within three years from the date of delivery to the consumer, Claber shall repair or replace any parts of this product found to be defective.
The warranty is void in the event of:

  • Lack of proof of purchase (invoice, receipt or cash register receipt);
  • Use or maintenance different from what is specified;
  • Disassembly or tampering by unauthorised personnel;
  • Faulty installation of the product;
  • Damages from atmospheric agents or contact with chemical agents;
    Claber accepts no liability for products that it has not manufactured, even if used in combination with its own products. The costs and the risks associated with shipment are met entirely by the owner. Assistance is provided by  Claber authorized service

USE

Insert the batteries. After a short test cycle, you will see the display as shown in Figure 1. If the display is off (1), press any button to turn on the backlighting (2). When the display is lit (programming enabled), the timer can be set.
To prolong battery life, the backlit display switches off automatically 30 seconds after the last key has been pressed.

PROGRAMMED WATERING

PROGRAMME SELECTION

Claber 8486 Tempo Select - USE 2

Press “M” repeatedly until the display shows:
– D : watering run time of the selected programme (the number of minutes watering takes place);
Press “F” repeatedly until the display shows:
– E : watering frequency (time between two successive watering cycles).

START WATERING: immediate start

Within 10 seconds of selecting the program, press the START key just once.
Once the key has been released and after 3 flashes of “0 h”, automatic watering will start immediately.

START WATERING: delayed start

Within 10 seconds from selecting the program, press the START key until the display shows C, the automatic watering start time delay of the selected line from 1 to 23 hours.

EXAMPLE OF USE

Claber 8486 Tempo Select - USE 6Claber 8486 Tempo
Select - USE 7

At 20.30 I want to program the timer to water for 10 minutes every 12 hours, starting from 21.30, I therefore:

  • Press the “M” key until the required run time has been set (eg. 10 minutes).

  • Press the “F” key until the required frequency has been set (eg. every 12 hours).

  • Press the “START” key twice within 10 seconds (to set a 2-hour delay).
    Watering:

  • will start automatically 1 hour after the key is pressed (i.e. at 21.30);

SET TO OFF

Claber 8486 Tempo Select - USE 8

To stop an irrigation cycle, press the middle button P until you reach OFF (Fig. 1), then press A or B according to the line you want to stop (Fig. 2). The programme will need to be reset.

RESET

MANUAL WATERING

Claber 8486 Tempo Select - USE 9Claber 8486 Tempo
Select - USE 10

Early stop for manual irrigation

Claber 8486 Tempo Select - USE 11

Exit manual mode

AT THE END OF WATERING CYCLES, THE FOLLOWING IS DISPLAYED:

Claber 8486 Tempo Select - USE 13

I want to modify programming. To modify programming, repeat procedure 1A or 1B. You do not need to switch to OFF.
The timer only works in manual mode, what should I do?
Check that the bridge connector on the timer or the connector on the Rain Sensor are inserted correctly.

WARNING

Read this instruction manual carefully and keep it handy for future reference. This device has been designed and manufactured exclusively for the setting of watering time by adults with experience and knowledge.
Any use other than that described in this manual is considered improper: the manufacturer acknowledges no liability for damages arising from improper use, which will also void the warranty.
Do not power the water timer with sources other than those specified. It is good policy – when the water timer is used for the first time – to make certain that the programmes run correctly. Do not use the water timer with chemicals or  liquids other than water.
At the end of the season, before the winter frosts, disconnect the timer from the tap, remove the batteries and store the timer in a sheltered place, away from damp, where the temperature does not fall below 3°C.

DISPOSAL

The symbol in question applied to the product or the packaging indicates that the product must not be considered as normal domestic waste, but must be taken to a special centre for the collection and recycling of waste electrical  and electronic equipment. Take care to dispose of this product in the proper way; this will help to avoid the negative consequences that could arise from unsorted collection or dumping. For more detailed information on the recycling of  this product, contact the municipal authority, the local refuse collection service or the dealer from whom the item was purchased.

Declaration of Conformity

****Assuming full responsibility, we declare that the product
Complies with the applicable European and British directives, as per the Declarations of Conformity accessible via the following link:

www.claber.com/conformity/

Fiume Veneto, 11/2022
Il Presidente Claber S.P.A.
Ing. Gian Luigi Spadotto

CLABER SPA – Via Pontebbana, 22 – 33080 Fiume Veneto PN – Italy
Tel. +39 0434 958836 – Fax +39 0434 957193
info@claber.comwww.claber.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals