Introduction

There are many considerations when selecting Honeywell’s Board Mount Pressure Sensors to determine the specific series for the application. This Selection Guide will provide an overview as to when to select:

TruStability™

  • RSC Series (High Resolution, High Accuracy, Compensated/Amplified)
  • HSC Series (Compensated/Amplified)
  • SSC Series (Compensated/Amplified)
  • TSC Series (Compensated/Unamplified)
  • NSC Series (Uncompensated/Unamplified)
    TruStability™

Basic

  • ABP Series (Compensated/Amplified)
  • TBP Series (Compensated/Unamplified)
  • NBP Series (Uncompensated/Unamplified)
    Basic Series
    Basic Series

MicroPressure

  • MPR Series (Compensated/Amplified)
    MicroPressure Series

24PC (Uncompensated/Unamplified)

  • 24PC Series
  • 24PC Flow-Through Series
    24PC Series

26PC (Compensated/Unamplified)

  • 26PC Series
  • 26PC Flow-Through Series
    26PC Series

Board Mount Pressure Sensors Portfolio Cross Reference

Characteristic TruStability™
RSC Series HSC Series
Series NSC Series
Signal conditioning amplified
Calibrated yes
Temperature compensated yes
Pressure range ±1.6 mbar to ±10 mbar
inH2O to ±150 psi ±60 mbar to ±10 bar
psi ±2.5 mbar to ±10 mbar
Device type absolute, differential, gage

absolute, differential, gage
Output| 24-bit digital SPI| analog (Vdc), digital (I2C, SPI)| analog (mV)
Total Error Band| as low as ±0.25 %FSS depending on pressure range (after customer auto-zero)| ±1 %FSS to ±3 %FSS depending on pressure range| ±2 %FSS to ±4 %FSS depending on pressure range| —
Accuracy| ±0.1 %FSS BFSL| ±0.25 %FSS BFSL| ±0.25 %FSS BFSL
Mounting| DIP, SMT| DIP, SIP, SMT| DIP, SIP, SMT
Compensated temperature range| -40°C to 85°C [-40°F to 185°F]| 0°C to 50°C [32°F to 122°F]| -20°C to 85°C [-4°F to 185°F]| 0°C to 85°C [32°F to 185°F]| —
Operating temperature range| -40°C to 85°C [-40°F to 185°F]| -20°C to 85°C [-4°F to 185°F]| -40°C to 85°C [-40°F to 185°F]
Approvals| REACH, RoHS| RoHS, WEEE
Summary|

  • Industry-leading long-term stability, Total Error Band, accuracy and flexibility
  • High burst pressures and working pressure ranges
  • Excellent repeatability
  • High 24-bit resolution

|

  • Industry-leading long-term stability, total error band, accuracy and flexibility
  • High burst pressures and working pressure ranges
  • Excellent repeatability
  • Liquid media compatible on port 1

|

  • Industry-leading long-term stabilit
  • Allows customers the flexibility of sensor self-calibration
  • Liquid media compatible on port 1
  • High burst pressures and working pressure ranges

Characteristic| Basic Pressure| MicroPressure| 24PC| 26PC
---|---|---|---|---
ABP Series| TBP Series| NBP Series| MPR Series| ****

24PC Series

| 24PC Flow-Through Series| 26PC Series| 26PC Flow-Through Series
Signal conditioning| amplified| unamplified| amplified| unamplified
Calibrated| yes| no| yes| no| yes
Temperature compensated| yes| no| yes| no| yes
Pressure range| ±60 mbar to ±10 bar | ±6 kPa to ±1 MPa | ±1 psi to ±150 psi| 60 mbar to 2.5 bar | 6 kPa to 250 kPa | 1 psi to 30 psi| SIP, DIP: 0.5 psi to 250 psi SMT: 1 psi to 15 psi| 1 psi to 100 psi| SIP, DIP: 1 psi to 250 psi SMT: 1 psi to 15 psi| 1 psi to 100 psi
Device type| differential, gage| gage| absolute, gage| absolute, gage| absolute, differential, wet-wet differential, gage| flow-through gage| differential, wet-wet differential, gage| flow-through gage
Output| digital (I2C, SPI) analog (Vdc)| analog (mV)| digital (I2C, SPI)| analog (mV)
Total Error Band| ±1.5 %FSS BFSL| —| as low as ±1.5 %FSS (after customer auto-zero)| —
Accuracy| ±0.25 %FSS BFSL| ±0.25 %FSS BFSL| linearity and hysteresis: 0.5% typ.| linearity and hysteresis: 0.75% typ.| linearity and hysteresis: 0.5% typ.| linearity and hysteresis: 0.35% typ.
Mounting| DIP, SMT, leadless SMT| leadless SMT| DIP, SIP, SMT| SIP| DIP, SIP, SMT| SIP
Compensated temperature range| 0°C to 50°C [32°F to 122°F]| 0°C to 85°C [32°F to 185°F]| —| 0°C to 50°C [32°F to 122°F]| —| 0°C to 50°C [32°F to 122°F]
Operating temperature range| -40°C to 85°C [-4 0 °F to 185°F]| -40°C to 125°C [-40°F to 257°F]| -40°C to 85°C [-4 0 °F to 185°F]| -40°C to 85°C [-40°F to 185°F]
Approvals| RoHS, WEEE, NSF-169, BPA Free, LFGB| REACH, RoHS, NSF-169, BPA Free, LFGB| RoHS, WEEE
Summary|

  • Designed to provide a simple, cost- effective, basic performance, high quality solution for those medical and industrial applications where high performance, stability, and accuracy are not as critical
  • Liquid media compatible on ports 1 and 2

|

  • Designed to provide a simple, cost- effective, basic performance, high quality solution for those medical and industrial applications where high performance, stability, and accuracy are not as critical
  • Liquid media compatible on ports 1 and 2

|

  • Designed to meet the requirements of higher volume medical (consumer and non-consumer) devices and commercial appliance applications
  • Low power consumption
  • Liquid media compatible

|

  • Miniature package
  • Operable after exposure to frozen conditions
  • Choice of termination for gage sensors
  • SMT: pick-up feature; maximum peak reflow temperature of 260°C [500°F]
  • End-point calibration; elastomeric construction
  • Media flow-through port option

Low Pressure* Selection Guide

Key Features

RSC Series, HSC Series, SSC Series

  • For use when:
    • Accuracy and low Total Error Band are required
    • Measuring gases
    • Ultra-low or low pressure ranges are needed
    • Performance is the key driver
  • Amplified analog
  • Digital output
  • Ease of installation
  • Many housing and port styles

RSC Series, High Resolution

  • High 24-bit resolution; analog-to-digital converter with integrated EEPROM
  • Extremely tight Total Error Band, as low as ±0.25 %FSS depending on pressure range (after customer auto-zero), due to Honeywell’s patented sense die design, in-house compensation, calibration, and mechanical package design
  • Extremely tight accuracy of ±0.1 %FSS BFSL (low power consumption, less than 10 mW, typ.)
  • Virtually insensitive to mounting orientation (±0.1 %FSS or ±0.2 %FSS, depending on pressure range) due to Honeywell’s patented sense die design.

*HSC Series (Ultra-Low Pressure Ranges)**

  • Extremely tight Total Error Band due to Honeywell’s patented sense die design, in-house compensation and calibration, and mechanical package design:
    • ±3 %FSS for 2 inH2O span
    • ±1.5 %FSS for 3 inH2O to 5 inH2O span
    • ±1 %FSS above 5 inH2O span
  • Virtually insensitive to mounting orientation (<0.15 %FSS) and very low vibration sensitivity due to Honeywell’s patented sense die design
  • High resolution (min. 0.03 %FSS analog, 12-bits digital) due to the use of sensors specifically designed for ultra-low pressures, not just amplifying higher range sensors
  • Port 1 can be exposed to non-corrosive, non-ionic liquids when the liquid media option is selected
  • Extremely tight accuracy: Inherently a linear sense die design/ diaphragm.

TSC Series

  • Compensated unamplified for those customers who require temperature compensation but want to do their own amplification
  • Back-side sensing allows for wet capability on one port; port 1 can be exposed to non-corrosive, non-ionic liquids
  • Ease of installation
  • Many housing and port styles

NSC Series

  • Uncompensated uncalibrated for those customers who want to do their own compensation, calibration, and amplification
  • Back-side sensing allows for wet capability on one port: port 1 can be exposed to non-corrosive, non-ionic liquids
  • Ease of installation
  • Many housing and port styles
Basic Pressure

ABP Series

  • Amplified and compensated, analog or digital output, single or dual ports, small package
  • Cost: Select the ABP Series if cost is a major concern and some sensor performance can be de-rated. The ABP series has fewer porting and housing options than the HSC Series and SSC Series
  • Ports 1 and 2 can be used with non-ionic liquids (wet/wet)when the liquid  media option is selected

TBP Series

  • Unamplified and compensated, analog output
  • Cost: Select the TBP Series if cost is a major concern and some sensor performance can be de-rated. The TBP series has fewer porting and housing options but does come in a smaller package.
  •  Port 1 can be used with non-ionic liquids when the wet option is selected

NBP Series

  • Unamplified and uncompensated, analog output
  • Back-side sensing allows for wet capability on one port: port 1 can be exposed to non-corrosive, non-ionic liquids
  • Cost: Select the NBP Series if, and only if, the application cannot be met with the other sensors noted above due tocost considerations; cost should be the  primary consideration when selecting the Basic NBP Series.
  • Port 1 can be used with non-ionic liquids when the wet option is selected
MicroPressure

MPR Series

  • 5 mm x 5 mm [0.20 in x 0.20 in] package footprint
  • Calibrated and compensated
  • 60 mbar to 2.5 bar | 6 kPa to 250 kPa | 1 psi to 30 psi
  • 24-bit digital I2C or SPI-compatible output
  • IoT (Internet of Things) ready interface
  • Low power consumption (<10 mW typ.), energy efficient
  • Stainless steel pressure port
  • Compatible with a variety of liquid media
  • Absolute and gage pressure types
  • Total Error Band after customer auto-zero: As low as ±1.5 %FSS
  • Compensated temperature range: 0ºC to 50ºC [32ºF to 122ºF]
  • REACH and RoHS compliant
  • Meets IPC/JEDEC J-STD-020D.1 Moisture Sensitivity Level 1
  • Available on breakout board for easier evaluation and testing
  • Select sensors available on breakout board for easy evaluation and testing
24PC, 26PC
  • 24PC: Unamplified and uncompensated
  • 26PC: Unamplified, temperature compensated and calibrated
  • Full liquid wet/wet differential sensing avoids having to use amedia isolated  sensor
  • Absolute (24PC), differential, wet-wet differential, gage
  • 0.5 psi to 250 psi (SIP, DIP); 1 psi to 15 psi (SMT)
  • Very small SMT package option
  • Many port styles
  • Fluorosilicone, EPDM, silicon and neoprene seals (DIP and SIP)
  • Pick and place features (SMT
  • Rugged mounting features
  • Proven quality and reliability
  • Ease of installation

Potential  Medical Applications

Potential Industrial and Consumer Applications

For more information

Honeywell Advanced Sensing Technologies services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor,
visit our website or call:

Asia Pacific: +65 6355-2828
Europe:   +44 (0) 1698 481481
USA/Canada: +1-800-537-6945

Honeywell Advanced Sensing Technologies
830 East Arapaho Road
Richardson, TX 75081
sps.honeywell.com/ast

Warranty

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to  Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell  be liable for consequential, special, or indirect damages.

While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

Honeywell Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals