PUSH PLATE FAMILY Stainless Steel Push Plates Instruction Manual
- June 13, 2024
- PUSH PLATE FAMILY
Table of Contents
PUSH PLATE FAMILY Stainless Steel Push Plates
DESCRIPTION
Images shown below are “Text & Logo” versions.
See table “Push Plate Models” on the following page for all available varieties.
-
4.5” ROUND
-
4.5” SQUARE
-
4.75” SQUARE
-
6” ROUND
-
6” SQUARE
-
JAMB
(with and without microswitch) -
SINGLE GANG
-
VESTIBULE
ACCESSORIES
-
BOLLARDS
-
BOXES
-
BRACKETS
-
TRANSMITTERS & RECEIVERS
-
TRANSMITTER, RECEIVER, LOGIC
-
LOGIC MODULE
| 4.5″ ROUND| 4.5″ SQUARE| 4.75″ SQUARE| 6″
ROUND| 6″ SQUARE| SINGLE GANG| VESTIBULE| J
AMB| JAMB (NARROW) W/MICROSWITCH| JAMB (W I DE)
W/MICROSWITCH
---|---|---|---|---|---|---|---|---|---|---
dimensions:| W: 4 ½”
H: 4 ½”
D: 5/s”| W: 4 ½”
H: 4 ½”
D: 5/s”| W: 4 ¾”
H: 4¾”
D: 5/s”| W:6″ H 6″
D: 5/s”| W: 6″
H: 6″
D: W’| W:2¾”
H: 4 ½”
D: 3/s”| W:4¾”
H: 4 ¾”
D: %”| W: 1 ½”
H: 4 ¾”
D: ¾”| W: 1 ½”
H: 4 ¾”
D: ¾”| W: 1 ¾”
H: 4 ½”
D: ½”
switch rating:| SPOT (1SA@ 125 or 250 VAC)| SPST (1A@ 120 VAC / 28 VDC)
“PUSH TO OPEN”| 10PBR45| 1OPBS45| 10P BS|
10PBR
|
10PBS6
| | | 10PBJ| |
“PRESS TO OPERATE DOOR”| | 10PBS45POD| | | | | | | |
“PUSH TO SLOW” W / BRAILLE (WH I TE TEXT
ON B L UE PLATE)| | | | | | | | 10PBJSREV| |
TEXT & **LOGO| 10PBR451| 10PBS451| 1OPBS1| 10 PBR1| 10PBS61| 10PB0
24 1| 10PBDGP1| 1Oe.BJ 1| 1 OPBJM1| 10PBJMS1 (hard-wired )
TEXT & **A L TERNATE LOGO| | 10PBS451 Al| 1OPBS1AL|
10PBR1AL| | | | | |
LOGO ONLY| 10PBR45LL| 10PBS45LL| 10PBSLL| 10PBRLL| 10PBS6LL| 10PB024L| |
10PBJLL| 10PBJML| 10PBJMSLL (hard-wired)
PLAIN FACE| 10PBR4510| 10PBS4510| 1OPBS10| 1OPBR10| 10PBS610| 10PB0 24
10| | 10PBJ10| |
WHITE TEX T ON BLUE PLATE| | 10PBS458| | | | | | | |
BLUE TEXT ON SATIN BRASS PLATE| | | 10PBS1S8| | | | | | |
WHITE T EXT & **LOGO ON BLUE PLATE| | 10PBS4518| 1OPBS1B|
| | | | 10PBJ1B| |
“PUSH TO EXIT”**| | | 10PBSE| | | 10PB024E| | 10PBJE| |
READ BEFORE BEGINNING INSTALLATION/PROGRAMMING/SET-UP
PRECAUTIONS
- Shut off all power going to header before attempting any wiring procedures.
- Maintain a clean and safe environment when working in public areas.
- Constantly be aware of pedestrian traffic around the door area.
- Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
- ESD (electrostatic discharge): Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board, ensure you dissipate your body’s ESD charge.
- Always check placement of all wiring before powering up to ensure that moving door parts will not catch any wires and cause damage to equipment.
- Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
- DO NOT attempt any internal repair of the components. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair:
- May jeopardize personal safety and may expose one to the risk of electrical shock.
- May adversely affect the safe and reliable performance of the product resulting in a voided warranty
The door control system and the header cover profile must be correctly grounded.
Only trained and qualified personnel are recommended to install and set up the sensor.
Always test the proper operation of the installation before leaving the premises.
The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel.
MOUNTING & WIRING
-
Mark and drill the appropriate holes for mounting.
10PBJMS (4-stud) plate: jigsaw required for the hole
10PBS45: face plate must be removed before wiring (using Phillips screwdriver) -
Wire the push plate to the door controller or radio-controlled transmitter using the NO and COM contacts.
If installing the Jamb with Microswitch (10PBJM1, 10PBJMS1, 10PBJML, or 10PBJMLL), wire-nut the microswitch to the door controller using the NO and COM contacts.
NOTE: The following accessories must be installed before securing push plate to the box:- adapter plate (10BRINGC for double-gang boxes and 50.5016 for vestibule plates)
- bracket (10PBRACKET or 10PBRACKETCA for surface-mounting)
- weather ring (10WRSQ475, 10WRRND45, 10WRRND6)
-
For all push plates except the 4.5” square, thread each hex-head screw 3
⁄4 of the way into the electrical enclosure. Leave about 1
⁄2” of the screw unthreaded. See note below for type of screw to use
The 4.5” plate (see image, right) requires #6 Phillips screws for both single- and double-gang installations. Once the back plate is secured, the face plate must be reattached. -
Install the push plate onto the box (see image, right), aligning the applicable keyholes with the hex screws. Slide the push plate down, and then secure the push plate to the box by tightening the screws using the provided hex key.
-
Test for proper push-plate activation.
MAINTENANCE
Clean the push plates using only a damp, non-abrasive cloth.
Regular cleaning with harsh solvents or abrasive materials may cause deterioration of the paint or coating
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect
installations or incorrect adjustments of the sensor/device; therefore, BEA,
Inc. does not guarantee any use of the sensor/ device outside of its intended
purpose.
BEA, Inc. strongly recommends that installation and service technicians be
AAADM-certified for pedestrian doors, IDA certified for doors/gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk
assessment following each installation/service performed, ensuring that the
sensor/device system performance is compliant with local, national, and
international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the
door/gate shall be performed per the door/gate manufacturer’s recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry
practices. Safety inspections must be performed during each service call –
examples of these safety inspections can be found on an AAADM safety
information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and
International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are
in place.
Visit website for available languages of this document.
CUSTOMER SUPPORT
Tech Support & Customer Service:
1-800-523-2462
General Tech Questions: techservices-us@BEAsensors.com | Tech Docs:
www.BEAsensors.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>