vetus FAN12 Permanent Ventilator Instruction Manual

June 4, 2024
vetus

vetus FAN12 Permanent Ventilator

Introduction

The VETUS electric ventilator, type FAN, is intended for ventilating accommodation rooms, bedrooms and toilets and for extracting warm air from a refrigerator on board a ship. The fan is virtually silent with a very low current consumption and is fitted with a two-speed switch.

Warning
In order to prevent personal injury, the electricity should always be disconnected during installation and maintenance. Never use the fan where the ambient temperature exceeds 70º C (158 degrees F).

Take Care!
As supplied, the fan will blow air from the inside to the outside, see Drawing

  1. It is possible to reverse this airflow (from outside to inside) by turning the fan with its housing round in its plastic casing. See Drawing 2.

Installation
Fit the fan on the wall or ceiling. It can be mounted either horizontally or vertically. Drill or saw a 75 mm. (3”) diameter hole in the ceiling or wall. Glue the self-adhesive gasket supplied to the flange on the fan blade housing. Drill the holes for the bolts or screws using the fan as a guide. Fix the fan with 3 bolts or screws. Tighten up evenly, but not so tight that the plastic cap cracks. The fan can also be fitted under an (existing) Vetus deck ventilator (type Ufo, Ufo-Trans, Goofy, or Scirocco).

Electrical connections

Check the onboard voltage is the same as that stated on the fan (12 or 24 V). Connect up the fan as shown in the wiring diagram. Install the + wire and 500 mA (for 12 Volts) or 250 mA (for 24 Volts) fuse. The fan is protected against incorrect connection.

Technical data

  • Motor: 12 V or 24 V direct current
  • Speed : 3,200 rpm
  • Power : 1.7 W @ 12 V; 1.8 W @ 24 V
  • Current : 0.145 A @ 12 V; 0.073 A @ 24 V The motor is ‘ignition protected.
  • Capacity : 70 m3/hour (41 CFM) for both 12 and 24 Volts
  • Weight : 0.2 kg (0.44 lbs)

Ambient

  • temperature : -10 to +70º C (14 to 158 degrees F)
  • Static Pressure: 5 mm (0.18”) H2O
  • Operating life: 50,000 operating hours, minimumvetus-FAN12-Permanent-Ventilator-fig-1
  • Fokkerstraat 571
  • 3125 BD Schiedam
  • Holland
  • Tel.: +31 (0)88 4884700
  • sales@vetus.nl
  • www.vetus.com