ZKTeco MiniAC Plus Biometric Attendance System User Guide
- June 16, 2024
- ZKTECO
Table of Contents
- Overview
- Installation Environment
- Device Installation
- Standalone Installation
- Door Sensor, Exit Button & Alarm Connection
- Lock Relay Connection
- RS485 Connection
- Wiegand Reader/SRB Connection
- Power Connection
- Ethernet Connection
- User Registration
- Ethernet and Cloud Server Settings
- Records Query
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Quick Start Guide
MiniAC Plus
Version: 1.1
Due to regular upgrades of systems and products, ZKTeco could not guarantee
exact consistency between
the actual product and the written information in this manual.
Overview
Installation Environment
Please refer to the following recommendations for installation.
Device Installation
① Attach the mounting template sticker to the wall, and drill holes according
to the mounting paper. Fix the back plate on the wall using wall mounting
screws.
② Attach the device to the back plate.
③ Fasten the device to the back plate with a security screw.
Standalone Installation
Door Sensor, Exit Button & Alarm Connection
Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock.
The NO LOCK (normally opened at power on) is connected with ‘NO1’ and ‘COM’
terminals, and the NC LOCK (normally closed at power on) is connected with
‘NC1’ and ‘COM’ terminals. Take NC Lock as an example below:
RS485 Connection
Wiegand Reader/SRB Connection
Power Connection
Recommended power supply
- 12V ± 10%, at least 3000mA.
- To share the power with other devices, use a power supply with higher current ratings.
Ethernet Connection
Click [COMM.] > [Ethernet] > [IP Address] , input the IP address and click
[OK].
Note: In LAN, IP addresses of the server (PC) and the device must be in
the same network segment when connecting to ZKBioAccess software.
User Registration
When there is no super administrator set in the device, click on to enter the
menu.
After setting the super administrator, the system will request for the
administrator’s verification before entering the menu. For the security
purpose, it is recommended to register a super administrator at the first time
you use the device.
Method1: Register on the device
Click on > [User Mgt.] > [New User] to register a new user. Settings include
entering user ID and name, registering a face, palm, password, badge and user
photo, setting user role and access control role.
Method2: Register on ZKBioAccess software
Please set the IP address and cloud service server address on the device.
-
Click [Access] > [Access Device] > [Device] > [Search Device] to add the device to the software.
When the device has set the server address and port, it can be added automatically.
-
Click [Personnel] > [Person] > [New] to register users in the software.
-
Add users to access levels.
-
Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices].
For more details, please refer to the ZKBioAccess User Manual.
Method3: Register on the phone
Once ZKBioAccess software installation, users could enroll face via browser
application on their own mobile phone.
-
Click [Personnel] > [Parameters], input ‘’http://Server address:Port’’ in the QR Code UGL bar. The software will automatically generates a QR code. Scan the QR code or login onto ‘’http://Server address:Port/app/v1/adreg’’ by the mobile phone to register users.
-
The users will display in [Personnel] > [Temporary Personnel], click [Review].
Ethernet and Cloud Server Settings
Click on > [COMM.] > [Ethernet] to set the network parameters. If the TCP/IP
communication of the device is successful, the icon will be displayed in the
upper right corner of the standby interface.
Click on > [COMM.] > [Cloud Server Setting] to set the server address and
server port, that is, the IP address and port number of the server after the
software is installed. If the device communicates with the server
successfully, the icon will be displayed in the upper right corner of the
standby interface.
Access Control Settings
Click on > [Access Control] to enter the access control management interface
and set relevant parameters of access control.
Records Query
Click on > [Attendance Search] > [Attendance Record] to enter the records query interface, input the user ID and select the time range, the corresponding attendance logs will be displayed.
Note for Palm Registration and Verification
Notes:
- Place your palm within 30-50cm of the device.
- Place your palm in the palm collection area, such that the palm is placed parallel to the device.
- Make sure to keep space between your fingers.
ZKTeco Biometrics India Pvt. Ltd. Global R &D Centre
Survey No 01/01, Outer Ring Road, Mahadevpura,
Bengaluru, Karnataka – 560048
Phone: 080-68281342/48 | Email: sales@zkteco.in |
Website: www.zkteco.in
Copyright © 2021 ZKTECO CO., LTD. All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>