VALCOM VIP-422A-SA Lay In Talkback IP Ceiling Speaker User Manual
- June 4, 2024
- Valcom
Table of Contents
VIP-422A-SA
Syn-Apps® Compliant
LAY-IN TALKBACK IP CEILING SPEAKER
INTRODUCTION
The VIP-422A-SA is a Syn-Apps Compliant Lay-In Talkback IP Ceiling Speaker to enable voice access to a single zone of paging over an IP-based network. This allows a page zone extension anywhere on the network. The speaker output level is controlled by the Syn-Apps server. The lay-in ceiling speaker grille is made of steel with a white baked enamel finish. The VIP-422A-SA replaces a 2’ x 2’ ceiling tile. Power is provided to the unit via a Power over an Ethernet (PoE) switch meeting the 802.3af specification.
SPECIFICATIONS
Access Methods
- Syn-Apps Revolution Server
- SIP–enabled telephone system
- Valcom M Cast Page Group
Features
- RJ-45 network connection
- Power over Ethernet (PoE) 802.3af compliant
- High-Efficiency Class-D Amplifier
Environment
Temperature: | 0 to +40° C |
---|---|
Humidity: | 0 to 85% non-precipitating |
These products are intended for use with a UL Listed power source marked “Class 2” or “LPS” rated 24VDC, or 48VDC (PoE). PoE and all interconnected ITE are intended for intra-building.
Dimensions/Weight
- 23.75” L x 23.75” W x 3.75” D (60.33 cm) x (60.33 cm) x (9.53 cm)
- Weight: 5.5 lbs. (2.49kg)
FCC Information
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates uses, and can radiate radio frequency energy if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense.
IMPORTANT SAFETY INFORMATION
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with dry cloth.
- Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
- Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.
- Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade and the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
- Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
- Only use attachments/accessories specified by the manufacturer.
- Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
- Unplug this apparatus during lightning storms or when unused for a long period of time.
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way. Such as when the power supply cord or plug is damaged, liquid has been spilled, objects have fallen into the apparatus or the apparatus has been exposed to rain or moisture and does not operate normally or has been dropped.
CAUTION: To reduce the risk of electric shock,
Do not remove cover (or back).
No user-serviceable parts inside.
Refer servicing to qualified service personnel.
This symbol indicates that dangerous voltage constituting a risk of electric
shock is present within this unit.
**** This symbol indicates that there are important operating and maintenance
instructions in the literature accompanying this unit.
INSTALLATION CONNECTIONS
Network Connection
The VIP-422A-SA has one RJ-45 network connector on the rear panel. Use a
standard Ethernet patch cable to connect the unit to an Ethernet switch.
Call Switch Connection
For IP Speakers using Talkback functionality, a call switch input via screw
terminals is provided. Connect a momentary contact switch to Switch 1 and
Ground.
-10 dB Line Level Out Connection
The -10dBm Line Level Out may be connected to up to 40 Valcom Self Amplified
Speakers in order to provide additional sound reinforcement in an area.
IP SPEAKER CONNECTIONS
Mute Out Connection
The Mute Out may optionally be connected to the mute input of Valcom audio
management systems in order to suspend locally originated audio during
intercom announcements. (See Figure 1)
LED 1 and LED 2 Connection
LED 1 (+) and LED 2 (-) is a current limited outputs designed to illuminate an
optional LED. The LED is intended to provide a visual indication of call
progress. The LED illumination will flash when the call switch is pressed and
will continue to flash until the call is answered. The LED illumination will
be solid when a connection to the unit is established.
Setup
The VIP-422A-SA will automatically acquire an IP address (using DHCP) and
connect to the Syn-Apps server when connected to the network and powered up.
Information specific to your application will need to be programmed into the
Syn-Apps server. Refer to the Syn-Apps documentation for further information.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being supplied to the unit and that there are no broken connections. If a spare unit is available, substitute a spare unit for the suspected defective unit.
Assistance in troubleshooting is available from the factory. Call 540-563-2000 and press 1 for Technical Support or via email at support@valcom.com. When requesting assistance, you should include all available information. It is strongly suggested that you go to the web site and review the information at www.valcom.com.
Valcom equipment is not field repairable. Valcom, Inc. maintains service facilities in Roanoke, VA. Should repairs be necessary, attach a tag to the unit clearly stating your company name, address, phone number, contact person, and the nature of the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
WARRANTY
Warranty information may be found on our website at
www.valcom.com/warranty.
References