algam MB100 100W LED Beam Moving Head User Manual

June 13, 2024
algam

algam logo MB100
100W LED BEAM MOVINGHEAD User Manualalgam MB100 100W LED Beam
Moving Head - Symbols 1

Thank you for choosing one of our Algam Lighting products. Please read this user’s manual carefully and follow the instructions to avoid danger or damage to the unit due to mishandling. Keep this user’s guide for future reference.

SAFETY INSTRUCTIONS

The symbols shown above are internationally accepted symbols to warn of potential hazards related to the use of electrical dangers associated with the use of electrical equipment. If any of these symbols are present on your device, please read the following instructions:

| ATTENTION !
Before using your equipment, we recommend that you read all the instructions in this manual.
---|---
| ATTENTION !
This device produces an intense and powerful light. Risk to the eyes. Do not look directly into the beam.
| DANGER !
Hazardous voltage, risk of electric shock. Do not open the product. To reduce the risk of electric shock do not expose this equipment to rain or moisture.
| ATTENTION !
Risk of burns. The exterior of the unit can become very hot. Do not touch within 10 minutes of use.
| ATTENTION !
Fire hazard. Keep all combustible and flammable materials away from the materials away from the unit during operation.
| DANGER !
Safety hazard. This appliance presents a significant risk of injury. Follow the safety instructions.
| Place the unit at least 50cm away from flammable materials and walls.

INSTALLATION

  • Unpack and check carefully for transport damage before using the product. Never put a damaged product into operation.

  • This product must be installed with strong hooks of adequate size for the weight carried. The product must be screwed to the hooks and tightened properly to prevent it from falling due to vibrations. Also check that the structure (or hanging point) can support at least 10X the weight of the hanging unit. The device must be installed by a qualified person and must be placed out of reach of the public. It is necessary to use a secondary hanging system (safety sling) approved for the weight of the device.

  • This unit is intended for indoor use only. Exposing the unit to rain or moisture may result in electric shock or fire.

  • Do not place the unit, speakers or any other object on top of the power cord and make sure it is not pinched.

  • For proper protection against electric shock, the unit must be connected to earth (ground). The electrical supply circuit must be equipped with a fuse or circuit breaker and a differential protection device.

  • Power Disconnection Notice: To disconnect the device from the power source, the power plug must be removed from the power outlet. For this reason, the device must be placed in a position that allows constant, unobstructed access to the power outlet. This way, in case of an emergency, you can disconnect the power plug immediately.

  • The unit should only be installed in a well ventilated area. Make sure that no ventilation slots are blocked. To ensure adequate ventilation, leave at least 20 cm of free air space around the sides and top of the unit.
    USAGE

  • This appliance must not be used by persons (including children) with limited physical, physiological or mental capabilities or lack of experience and/or knowledge, unless they are supervised by a person responsible for their safety or are instructed by that person in the operation of the appliance.

  • Never leave this equipment unattended.

  • If you experience any problems with the unit, stop using it immediately. Do not attempt to repair it yourself. Contact your dealer or an authorized service center. There are no user replaceable parts.

  • NEVER use the unit under the following conditions:

    In areas subject to vibration or bumps,
    In places where the ambient temperature is above 45 ° C or below 2 ° C.
    In areas exposed to excessive dryness or humidity (ideal conditions: between 35% and 80%).

  • Never use the unit near flames, flammable or explosive materials or hot surfaces. Doing so may cause a fire.

  • The exterior of the unit can become very hot. It is important to avoid contact with the unit during operation and for at least 10 minutes after use.

  • It is important to use the supplied power cable (grounded cable).

  • Before turning on the power, make sure that the voltage and frequency of the power supply match the power requirements of the unit, as described in this manual.

  • Never cut or tamper with the power cord or plug. If a power cord is provided with a ground wire, it is required for safe operation! Risk of fatal electric shock!

  • Always hold the power cord by the plug. Do not pull on the cord itself and never touch the power cord with wet hands as this may cause a short circuit or electric shock.

  • Do not connect this device to a dimmer pack

  • DO NOT allow liquids or objects to enter the unit. If liquid is spilled on the unit, immediately UNPLUG the power supply to the unit and contact customer service.

  • You must ensure that the power cord never gets wet during operation. Before a thunderstorm and/or a lightning storm, unplug the unit from the mains.

  • Under no circumstances should you open the housing of the device. If you do, your safety will not be assured. There are no operational components inside, only dangerous voltages that can give you a fatal shock!

MAINTENANCE / SERVICE

  • Never attempt to disassemble, repair or modify the unit yourself. Otherwise, the warranty becomes void. Repairs by unqualified persons may result in damage or malfunction. Please contact the nearest authorized service center. The light source contained in this fixture should only be replaced by the manufacturer or its service agent or a person of equivalent qualification.
  • Screens, lenses or UV filters should be replaced if they are visibly damaged to an extent that compromises their effectiveness, such as by deep cracks or scratches.
  • The lamp should be replaced if it has been damaged or deformed by heat.
  • Disconnect the unit from the mains before servicing.
  • If the cable or flexible outer cord of this fixture is damaged, it must be replaced with a special cable or cord from the manufacturer or its service agent only.
  • Never immerse the unit in water or any other liquid. Wipe only with a slightly damp cloth.

PRODUCT INSTALLATION

POWER SUPPLY
Please use the attached power, note that power voltage and frequency are the same as the marked voltage and frequency of device when connecting power. Every device’s power should be connected separately, so that device can be controlled individually.
DMX CONNECTION
Connection between laser lights and DMX must use the shield cable of diameter more than 0.5mm. Please use the attached pin XLR plug/socket to connect the DMX output/input interface. The connection between sokcet and cable as below (note the plug/socket’s 3 pin number and position).algam MB100 100W LED Beam
Moving Head - CONNECTIONWhen using standard DMX512 control signal, the last device’s output interface must be connected to a DMX plug.
This plug is putting a 120 ohm resistance between “canon” plug’s 2 pin and 3 pin. Showing as below pic. Sticking this plug into the last device’s signal output interface, it will avoid the interference during the process of signal transmission.

INSTALLATION – RIGGING

This fixture can be installed on the floor on a flat and stable surface. It can be clamped to a struss or similar rigging structure in any orientation.
Check that the rigging structure can support at least 10 times the weight of all fictures and equipment which are installed on it. When installing the fixture on truss, it is recommanded to use half-coupler clamp (see below). One or two pieces OMEGA ( depends on the version) brackets are supplied with the fixture . Fix the rigging clamp with self-locking nuts to the OMEGA . OMEGA brackets are locked to the fixture with 1/4 turn fast lock screw system.
SECURE WITH SAFETY CABLE !
Secure the fixture with safety cable.

PRODUCT PRESENTATION

algam MB100 100W LED Beam Moving Head - PRESENTATION

FONCTION DESCRIPTION
1 LED error indicator Flashes to indicate that there is an error message
2 LED DMX indicator Lights ON when the DMX signal is received
3 LCD display Menu and function display
4 Keyboard For menu and sub-menu navigation
5 Mains switch Power switch ON/OFF
6 Protection fuse Electric fuse protection
7 Power OUT connector To connect more fi xtures . Load max. 960W
8 Power IN connector Power input. Use incuded power lead
9 DMX OUTXLR connector DMX signal output
10 DMX IN XLR connector DMX signal input

algam MB100 100W LED Beam Moving Head - CONTROLSUse buttons and to navigate in main menu. Press to confi rm your selection.
Man MANUAL CONTROL

Manual

1. Pan| 0
2. Pan Fine| 0
3. Tilt| 128
4. Tilt Fine| 0

Use and to navigate into menu and sub-menu.Yellow arrow indicates selected line.
Press key to enter into edit status, the value becomes RED, then use et to select , then press to validate.
Press ** to come back into previsou function or menu.
Set SETTINGS**

Setting

Run Mode| DMX
DMX Address| 1
Sensitivity| 1
Channel Mode| 16CH

DMX
Slave status: Receive DMX signals from the console or Master
AUTO1 Auto run ;
AUTO2
Random Master status: Auto run and send
DMX signal to slave
Sound

DMX ADDRESS| 001-512| Press  key enter into edit status, then press to change DMX address.
press   key save and exit edit status.
---|---|---
CHANNEL MODE| 16CH
20CH| Standard 16 Channel Mode, 17-20CH No Function
Extend 20 Channel Mode, 17-20CH for speed control.
(please check the detail on Channel table.)
TOP LAMP TEMP| 0-110| Affichage de la température de la LED (en °C)
INVERT PAN| ON
OFF| ON for starting and ending , the default is OFF.
INVERT TILT| ON
OFF| ON for starting and ending , the default is OFF.
PAN-TILT SWAP| ON
OFF| Exchange Pan/Tilt channel (include Pan/Tilt Fine)
PAN-TILT ENCODER| ON
OFF| Use encoder (optocoupler) to determine out of step and automatically correct position
Correct position without encoder (optocoupler)
DMX SIGNAL| KEEP
CLEAR| Continue running as it is
All motors return to the position and stop running.
LINEAR COLOR| ON
OFF| Color liner change
Color nonlinear change, half color change
LOAD DEFAULT| OK| Press the  button to see the confirmation dialog, press again The key restores the default settings

Sys SYSTEM PARAMETERS

System

V T108A-LED100-A001
Reset cal|
Sensor Monitor|
System Errors|
VERSION NO.(V)| Version No.
---|---
RESET
CALIBRATION| Pan Calibration
Tilt Calibration
Color Calibration
Gobo Calibration
Focus Calibration
Prism1 Calibration
Prism2 Calibration
Rainbow Calibration
Frost Calibration| After entering the subinterface,
you can adjust the motor such as
X-axis and Y-axis.
Reset position to compensate for
errors in hardware installation,
Adjustment range – 128~+127, +0
means no adjustment.
SENSOR MONITOR| Pan Hall
Tilt Hall
Color Hall
Gobo Hall
Focus Hall
Prism1 Hall
Prism2 Hall
Panwheel State
Tiltwheel State
Panwheel Step
Tiltwheel Step| 0 when magnetic is detected, otherwise 1
2 digits, each corresponding to a photoelectric switch in the encoder disc
When walking in the positive direction, the step value should increase, when going back,
SYSTEM ERRORS| (See common mistakes Rear)| If the red ERR indicator is lit, the luminaire is running.
An error can be made by going to the sub-interface for details. After viewing, you can press the “Clear” button to clear the error record.
DMX MONITOR| | This enters the subinterface and displays the channel values as values for viewing.

ERRORS

MT BOARD CONNECTION FAILED| The driver board did not respond. Serial communication line connecting display
panel and driver board There is a problem, or there is a problem with the driver board.
---|---
PAN RESET FAILED| X-axis photoelectric switch, or problem with X-axis motor
TILT RESET FAILED| Y-axis photoelectric switch, or problem with Y-axis motor
PAN HALL FAILED| Pan Hall have problem
TILT HALL FAILED| Tilt Hall have problem
COLOR WHEEL RESET FAILED| Color Wheel Hall , or Color Wheel motor have problem
GOBO WHEEL RESET FAILED| Gobo Wheel Hall , or Gobo Wheel motor have problem
FOCUS RESET FAILED| Focus Hall , or Focus motor have problem

DMX PROTOCOL

CHANNEL FUNCTION VALUE EFFECT
CH1 Pan 0-255 Pan 540 degree scan
CH2 Pan Fine 0-255 Pan 1.2 degree scan
CH3 Tilt 0-255 Tilt 270 degree scan
CH4 Tilt Fine 0-255 Tilt 1.2 degree scan
CH5 Dimmer 0-255 From dark to bright
CH6 Strobe 000-003 OFF
004-251 Strobe from slow to fast
252-255 ON > (control by dimmer channel)
CH7 Color Wheel 000-004 White
005 -009 White + Colon
010 – 014 Color 1
015 – 019 Color 1 + Color 2
020 – 024 Color 2
025 – 029 Color 2 + Color 3
030 – 034 Color 3
035 – 039 Color 3 + Color 4
040 – 044 Color 4
045 – 049 Color 4 + Color 5
050 – 054 Color 5
055 – 059 Color 5 + Color 6
060 – 064 Color 6
065 – 069 Color 6 + Color 7
070 – 074 Color 7
075 – 079 Color 7+ Color 8
080 – 084 Color 8
085 – 089 Color 8 + Color 9
090 – 094 Color 9
095 – 099 Color 9 + White
100 -177 Positive flow (from fast to slow)
178 – 255 Reverse flow(from slow to fast)

algam MB100 100W LED Beam Moving Head - COLOR

CHANNEL FUNCTION VALUE EFFECT
CH8 Gobo Wheel 000-004 White
005 -009 Gobo 1
010 – 014 Gobo 2
015 – 019 Gobo 3
020 – 024 Gobo 4
025 – 029 Gobo 5
030 – 034 Gobo 6
035 – 039 Gobo?
040 – 044 Gobo 8
045 – 049 Gobo 9
050 – 054 Gobo 10
055 – 059 Gobo 11
060 – 064 Gobo 12
065 – 069 Gobo 13
070 – 074 Gobo 14
075 – 079 Gobo 15
080 – 084 White shake(from slow to fast)
085 – 089 Gobo 1 shake(from slow to fast)
090 – 094 Gobo 2 shake (from slow to fast)
095 – 099 Gobo 3 shake (from slow to fast)
100 -104 Gobo 4 shake (from slow to fast)
105 -109 Gobo 5 shake (from slow to fast)
110 – 114 Gobo 6 shake (from slow to fast)
115 -119 Gobo 7 shake (from slow to fast)
120 -124 Gobo 8 shake (from slow to fast)
125 -129 Gobo 9 shake (from slow to fast)
130 -134 Gobo 10 shake (from slow to fast)
135 -139 Gobo 11 shake (from slow to fast)
140 -144 Gobo 12 shake(from slow to fast)
145 – 149 Gobo 13 shake (from slow to fast)
150 -154 Gobo 14 shake (from slow to fast)
155 -159 Gobo 15 shake (from slow to fast)
160 – 207 Positive flow If rom fast to slow)
208 – 255 Reverse flow (f rom slow to fast)
CHANNEL FUNCTION VALUE EFFECT
--- --- --- ---
C1-I9 Prism 1 000-127 Prism 1 out
128-255 Prism 1 in
CH10 Prism 1 Rotation 000-127 Prism angle adjustment
128-190 Reverse rotation (from fast to slow)
191-192 Stop
193-255 Forward rotation (from slow to fast)
CH11 Prism 2 000-127 Prism 2 out
128-255 Prism 2 in
CH12 Prism 2 Rotation 000-127 Prism angle adjustment
128-190 Reverse rotation (from fast to slow)
191-192 Stop
193-255 Forward rotation (from slow to fast)
CH13 Focus 0-255 Pattern definition from far to near
CH14 7-Color Effect 000-127 7-Color Effect out
128-255 7-Color Effect in
CH15 Frost 000-127 Frost out
128-255 Frost in
CH16 Reset 000-049 No Function
050-099 Small Motor Reset
100-199 Big Motor(Pan/Tilt) Reset
200-255 All Motor Reset

EXTEND CHANNEL

CANAL FONCTION VALEUR EFFET
CH17 Pan/Tilt Speed 000-255 Speed from fast to slow
CH18 Color Wheel Speed
CH19 Dimmer-Prism-Frost Speed
CH2O Gobo Wheel Speed

SPECIFICATIONS

Lighting source 100W WHITE LED
Average Lifetime 50 000 hours
Color temperature 7000k – 7500k
Brightness 123000lux@4m
Color wheel 9 colors+white, rotation with variable direction and speed
Gobo wheel 15 gobos+open, wheel rotation and shake effect
Shutter Strobe effect, pulse effect
Prism Dual prism 8 and 16 facets with vaiable speed rotation
Frost Motorized
Focus Motorized 100% linear
Dimmer 0-100% linear curve
PAN 540° with fine control and position calibration and position auto-

correction
TILT| 270° with fine control and position calibration and position auto- correction
Beam angle| 2°
Control system| DMX-512 USITT
DMX channels| 16 or 20
Setting and addressing| Control panel with large LCD display
Manual control| All functions can be manually controlled via control panel
Auto controls| AUTO1, AUTO2, random and sound
Installation| 2x OMEGA brackets with 1/4 tuen lock
Protection| IP20
Power supply| Lock connector for IN and OUT power
DMX input| 3 pin XLR connectors for IN and OUT
Power supply voltage| 100-240V~ 50/60Hz auto ranging
Power consumption| 120W
Max load| 960W from POWER OUT connector
Net weight| 11,8kg
Dimensions| 280mm x 215mm x 510mm

SPECIAL INSTRUCTIONS

  • During the reset process, press and hold the 5 seconds button to interrupt the reset.

  • Press and hold the key during power-on to interrupt the reset process and enter test mode.
    SIGNAL INDICATOR

  • The ERR red indicator flashes to indicate that there is an error message and enters the “System Information” > System Error” view information.

  • DMX green indicator light, steady light indicates that the DMX signal is received, and frequent off indicates no DMX signal.

This product is subject to the European Waste Electrical and Electronic Equipment Directive (WEEE) in its currently valid version.
Do not dispose with your normal household waste.
Dispose of this device through an approved waste disposal arm or through your local waste facility.
When discarding the device, comply with the rules and regulations that apply in your country.
If in doubt, consult your local waste disposal facility.
This Algam Lighting product is compliant to all required UE certifications and conformed to following standard and UE directives:
LVD Directive 2014/35/EU :
EMC Directive 2014/30/EU :
RoHS 2 Directive 2011/65/EU
The UE DECLARATION OF CONFORMITY is available, if you need it, please just ask for it at : [email protected]algam MB100 100W
LED Beam Moving Head - Notesalgam MB100 100W LED Beam
Moving Head - Fig

ALGAM
2 Rue de Milan, 44470 Thouaré-sur-Loire, FRANCE
NL user manuals also available, please contact: [email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

algam User Manuals

Related Manuals