THERMAL ZONE TZALNS13 iM Air Conditioners TZALNS13
Cooling Efficiencies up to: 15.2 SEER2/12 EER2
Nominal Sizes: 1.5 to 5 Ton [5.3 to 17.6 kW]
Cooling Capacities: 17.1 to 55.5 kBTU [5.0 to 16.3 kW]

Manufactured for
Thermal Zone™
Philadelphia, PATHERMAL ZONE TZALNS13 iM Air Conditioners -
Icon

*Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.

Features and Benefits

  • 7 mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
  • Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space—provides a minimum working area of 27-square inches for easier access
  • Triple Service Access: 15 in. wide, industry leading corner service access, two fastener, removeable corner and individual louver panels – makes repairs easier and faster

Model Number Identification

Air Conditioners

TZ| A| L| N| S| 13| 18| A| J| N| A| LHP
---|---|---|---|---|---|---|---|---|---|---|---
Brand| Product Category| Refrigerant| Region| Stages| SEER2| Capacity BTUIHR| Major Series| Voltage| Controls| Minor Series| Option Code
TTZ-Thermal Zone| A – Air Conditioners| L – R-410A| N – North| S – Single Stage| 13 -13.4 SEER2| 18 – 18,000 [5.28 kW] 24 – 24,000 [7.03 kW] 30 – 30,000 [8.79 kW] 36 – 36,000 [10.55 kW] 42 – 42,000 [12.31 kW] 48 – 48,000 [14.07 kW] 60 – 60,000 [17.58 kW]| A – 1st Design| J – 1ph. 208-230/60| N – Non- Communicating| A – 1st Series| LHP – W/HLPC
[ ] Designates Metric Conversions Available Models| Description
---|---
TZALNS1318AJNA| 1 1/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
TZALNS1318AJNALHP| 1 1/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
TZALNS1324AJNA| 2 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
TZALNS1324AJNALHP| 2 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
TZALNS1330AJNA| 2 1/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
TZALNS1330AJNALHP| 2 1/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
TZALNS1336AJNA| 3 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
TZALNS1336AJNALHP| 3 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
TZALNS1342AJNA| 3 1/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
TZALNS1342AJNALHP| 3 1/2 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
TZALNS1348AJNA| 4 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
TZALNS1348AJNALHP| 4 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
TZALNS1360AJNA| 5 ton 13.4 SEER2 Single-Stage iM Air Conditioner-208/230/1/60
TZALNS1360AJNALHP| 5 ton 13.4 SEER2 Single-Stage iM Air Conditioner w/ High/Low Pressure-208/230/1/60
Standard Equipment

R-410A Refrigerant
Scroll Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Optimized Venturi Airflow
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays

General Data/Electrical Data

General Data

Model No.| TZALNS1318| TZALNS1324| TZALNS1330| TZALNS1336| TZALNS1342| TZALNS1348| TZALNS1360
Nominal Tonnage| 1.5| 2.0| 2.5| 3.0| 3.5| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 3/4| 3/4| 7/8| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 70| 78| 86| 106| 126| 121| 186
Compressor Type| Scroll
Outdoor Coil|
Net face area – Outer Coil| 10.9| 13.3| 13.3| 13.3| 14.3| 23.5| 28.4
Net face area – Inner Coil| —| —| —| 12.9| 13.9| —| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276| 0.276| 0.276| 0.375
Number of rows| 1| 1| 1| 2| 2| 1| 1
Fins per inch| 24| 24| 24| 24| 24| 24| 22
Outdoor Fan|
Diameter – in.| 20| 24| 24| 24| 24| 26| 26
Number of blades| 2| 3| 3| 3| 2| 3| 3
Motor hp| 1/7| 1/6| 1/6| 1/6| 1/5| 1/5| 1/5
CFM| 1765| 3439| 3439| 2957| 2830| 4095| 4189
RPM| 1075| 825| 825| 825| 825| 850| 850
Watts| 154| 197| 197| 188| 145| 203| 204
Shipping weight – lbs.| 148| 166| 170| 193| 224| 251| 279
Operating weight – lbs.| 141| 159| 163| 186| 217| 244| 272
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 25| 30| 30| 40| 50| 50
Minimum circuit ampacity5| 12| 16| 19| 18| 25| 33| 34
Compressor|
Rated load amps| 9| 12| 14| 13| 19| 25| 26
Locked rotor amps| 43| 60| 68| 83| 110| 120| 150
Condenser Fan Motor|
Full load amps| 0.8| 0.8| 0.8| 0.8| 0.8| 1.0| 1.0
Locked rotor amps| 1.5| 1.5| 1.5| 1.7| 1.5| 2.4| 2.4

¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Accessories/Weighted Sound Power

Accessories

Model No.| TZALNS1318| TZALNS1324| TZALNS1330| TZALNS1336| TZALNS1342| TZALNS1348| TZALNS1360
---|---|---|---|---|---|---|---
Compressor crankcase heater*| 44-17402-44| 44-17402-44| 44-17402-44| 44-17402-44| 44-17402-45| 44-17402-45| 44-17402-45
Low ambient control| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08| RXAD-A08
Compressor sound cover| 68-23427-26| 68-23427-26| 68-23427-26| 68-23427-26| 68-23427-25| 68-23427-25| 68-23427-25
Compressor hard start kit| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1| SK-A1
Compressor time delay| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01| RXMD-B01
Low pressure control| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07| RXAC-A07
High pressure control| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07| RXAB-A07
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V
Top Cap w/Label| 91-101123-36| 91-101123-36| 91-101123-36| 91-101123-36| 91-101123-36| 91-101123-36| 91-101123-36

*Crankcase Heater recommended with Low Ambient Kit.
Weighted Sound Power Level (dBA)

Unit Size – Voltage, Series| Standard Rating (dBA)| TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
TZALNS1318| 70| 46.7| 54.5| 60.8| 59.9| 58.2| 53.4| 46.9
TZALNS1324| 71| 46.3| 58.4| 62.7| 59.0| 58.0| 52.4| 47.3
TZALNS1330| 71| 47.0| 62.4| 62.6| 59.3| 57.2| 55.7| 47.1
TZALNS1336| 71| 45.5| 58.4| 63.9| 59.2| 56.6| 52.1| 47.7
TZALNS1342| 68| 46.4| 53.7| 59.7| 55.9| 55.3| 53.6| 50.3
TZALNS1348| 71| 49.2| 56.2| 62.3| 59.5| 57.9| 49.9| 40.7
TZALNS1360| 76| 49.1| 58.7| 68.7| 65.2| 63.5| 60.1| 55.7

NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

Unit Dimensions

Unit Dimensions

**Model No.** OPERATING SHIPPING
H (Height) L (Length) W (Width)
(Length)** W (Width)
INCHES mm INCHES
mm INCHES mm
TZALNS1318 25.00 635

822
TZALNS1324| 25.00| 635| 33.75| 857| 33.75| 857| 26.50| 673| 36.38| 924| 36.38| 924
TZALNS1330| 25.00| 635| 33.75| 857| 33.75| 857| 26.50| 673| 36.38| 924| 36.38| 924
TZALNS1336| 25.00| 635| 33.75| 857| 33.75| 857| 26.50| 673| 36.38| 924| 36.38| 924
TZALNS1342| 27.00| 686| 33.75| 857| 33.75| 857| 28.50| 724| 36.38| 924| 36.38| 924
TZALNS1348| 39.00| 991| 35.75| 908| 35.75| 908| 40.50| 1029| 38.38| 975| 38.38| 975
TZALNS1360| 45.00| 1143| 35.75| 908| 35.75| 908| 46.50| 1181| 38.38| 975| 38.38| 975

THERMAL ZONE TZALNS13 iM Air Conditioners - Low[ ] Designates Metric Conversions

Clearance

Clearance

THERMAL ZONE TZALNS13 iM Air Conditioners - WALL

Control Wiring/Application Guidelines

Control Wiring

THERMAL ZONE TZALNS13 iM Air Conditioners - Control
Wiring

Application Guidelines

  1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
  2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
  3. Maximum outdoor operating air temperature is 125°F (51.7°C).
  4. For reliable operation, unit should be level in all horizontal planes.
  5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  6. Do not apply capillary tube indoor coils to these units.
  7. Factory-supplied filter drier must be installed.

Refrigerant Line Size Information

13.4 SEER2 Single-Stage Air Conditioners

**Unit Size| ****Allowable Liquid Line Size| ****Allowable Suction Line Size| Apply Long Line Guidelines if Linear Line Length Exceeds Those Shown Below (Feet)| Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150| 151-175| 176-200| 201-225| 226-250
TZALNS13| Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier
**
1.5 Ton  **SEE NOTE 3| 1/4″| 5/8″| N/A| 25 / 1.00| 50 / 0.99| 62 / 0.98| 43 / 0.98| 24 / 0.97| 5 / 0.97| NR| NR| NR| NR
5/16″| 5/8″| N/A| 25 / 1.00| 50 / 0.99| 75 / 0.98| 98 / 0.98| 93 / 0.97| 88 / 0.97| 83 / 0.96| 78 / 0.96| 73 / 0.95| 68 / 0.94
3/8″| 5/8″| 178| 25 / 1.00| 50 / 0.99| 75 / 0.98| 100 / 0.98| 100 / 0.97| 100 / 0.97| 100 / 0.96| 100 / 0.96| 100 / 0.95| 100 / 0.94
1/4″| 3/4″| N/A| 25 / 1.00| 50 / 1.00| 62 / 0.99| 43 / 0.99| 24 / 0.99| 5 / 0.99| NR| NR| NR| NR
5/16″| 3/4″
| N/A| 25 / 1.00| 50 / 1.00| 75 / 0.99| 98 / 0.99| 93 / 0.99| 88 / 0.99| 83 / 0.99| 78 / 0.98| 73 / 0.98| 68 / 0.98
3/8″| 3/4″| 178| 25 / 1.00| 50 / 1.00| 75 / 1.00| 100 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.98| 100 / 0.98
**
2 Ton| 1/4″| 5/8″| N/A| 25 / 0.99| 50 / 0.98| 21 / 0.97| NR| NR| NR| NR| NR| NR| NR
5/16″| 5/8″| 213| 25 / 0.99| 50 / 0.98| 75 / 0.97| 87 / 0.96| 77 / 0.95| 69 / 0.94| 61 / 0.93| 53 / 0.92| 45 / 0.91| 37 / 0.90
3/8″| 5/8″| 142| 25 / 0.99| 50 / 0.98| 75 / 0.97| 100 / 0.96| 100 / 0.95| 100 / 0.94| 98 / 0.93| 95 / 0.92| 92 / 0.91| 89 / 0.90
1/4″| 3/4″| N/A| 25 /1.00| 50 / 1.00| 21 / 0.99| NR| NR| NR| NR| NR| NR| NR
5/16″| 3/4″| 213| 25 /1.00| 50 / 1.00| 75 / 0.99| 87 / 0.99| 77 / 0.98| 69 / 0.98| 61 / 0.98| 53 / 0.97| 45 / 0.97| 37 / 0.96
3/8″| 3/4″| 142| 25 / 1.00| 50 / 1.00| 75 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.98| 98 / 0.98| 95 / 0.97| 93 / 0.97| 90 / 0.96
** 2.5 Ton| 5/16″| 5/8″| N/A| 25 / 0.99| 50 / 0.98| 75 / 0.96| 70 / 0.94| 59 / 0.93| 48 / 0.91| 36 / 0.90| NR| NR| NR
3/8″| 5/8″| 142| 25 / 0.99| 50 / 0.98| 75 / 0.96| 100 / 0.94| 98 / 0.93| 94 / 0.91| 90 / 0.90|
NR| NR| NR
5/16″| 3/4″| 213| 25 / 1.00| 50 / 0.99| 75 / 0.99| 70 / 0.98| 59 / 0.98| 48 / 0.97| 36 / 0.96| 25 / 0.96| 13 / 0.95|
NR
3/8″| 3/4″| 142| 25 / 1.00| 50 / 0.99| 75 / 0.99| 100 / 0.98| 98 / 0.98| 94 / 0.97| 90 / 0.96| 86 / 0.96| 82 / 0.95| 78 / 0.95
**
3 Ton| 5/16″| 5/8″| N/A| 25 / 0.99| 50 / 0.97| 66 / 0.94| 49 / 0.92| 32 / 0.90| NR| NR| NR| NR| NR
3/8″| 5/8″| 108| 25 / 0.99| 50 / 0.97| 75 / 0.94| 95 / 0.92| 89 / 0.90| NR| NR| NR| NR| NR
5/16″| 3/4″| N/A| 25 / 1.00| 50 / 0.99| 66 / 0.98| 49 / 0.98| 32 / 0.97| 15 / 0.96| NR| NR| NR| NR
3/8″| 3/4″| 108| 25 / 1.00| 50 / 0.99| 75 / 0.98| 95 / 0.98| 89 / 0.97| 84 / 0.96| 78 / 0.95| 72 / 0.94| 67 / 0.93| 61 / 0.93
1/2″| 3/4″| 54| 25 / 1.00| 50 / 0.99| 75 / 0.98| 100 / 0.98| 100 / 0.97| 100 / 0.96| 100 / 0.95| 100 / 0.94| 100 / 0.93| 100 / 0.93
5/16″| 7/8″| N/A| 25 / 1.00| 50 / 1.00| 66 / 1.00| 49 / 0.99| 32 / 0.99| 15 / 0.99| NR| NR| NR| NR
3/8″| 7/8″| 108| 25 / 1.00| 50 / 1.00| 75 / 1.00| 95 / 0.99| 89 / 0.99| 84 / 0.99| 78 / 0.98| 72 / 0.98| 67 / 0.98| 61 / 0.97
1/2″| 7/8″| 54| 25 / 1.00| 50 / 1.00| 75 / 1.00| 100 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.98| 100 / 0.98| 100 / 0.97
** 3.5 Ton| 3/8″| 3/4″| 150| 25 / 0.99| 50 / 0.98| 75 / 0.97| 88 / 0.96| 80 / 0.95| 72 / 0.94| 65 / 0.92| 57 / 0.91| 49 / 0.90| NR
1/2″| 3/4″| 75| 25 / 0.99| 50 / 0.98| 75 / 0.97| 100 / 0.96| 100 / 0.95| 100 / 0.94| 100 / 0.92| 100 / 0.91| 100 / 0.90|
NR**
3/8″| 7/8″| 150| 25 / 1.00| 50 / 1.00| 75 / 0.99| 88 / 0.99| 80 / 0.99| 72 / 0.98| 65 / 0.97| 57 / 0.97| 49 / 0.96| 42 / 0.96
1/2″| 7/8″| 75| 25 / 1.00| 50 / 1.00| 75 / 0.99| 100 / 0.99| 100 / 0.99| 100 / 0.98| 100 / 0.97| 100 / 0.97| 100 / 0.96| 100 / 0.96

NOTES:

  1. Do not exceed 61m linear line length.
  2. *Do not exceed 30m vertical separation if outdoor unit is above indoor unit.
  3. **19.05mm suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

13.4 SEER2 Single-Stage Air Conditioners

**Unit Size| ****Allowable Liquid Line Size| ****Allowable Suction Line Size| Apply Long Line Guidelines if Linear Line Length Exceeds Those Shown Below (Feet)| Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150| 151-175| 176-200| 201-225| 226-250
TZALNS13| Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier
**
4 Ton| 3/8″| 3/4″| 148| 25 / 0.99| 50 / 0.98| 75 / 0.96| 77 / 0.95| 67 / 0.93| 57 / 0.92| 46 / 0.91| NR| NR| NR
1/2″| 3/4″| 74| 25 / 0.99| 50 / 0.98| 75 / 0.96| 100 / 0.95| 100 / 0.93| 100 / 0.92| 100 / 0.91| NR| NR| NR
3/8″| 7/8″| 148| 25 / 1.00| 50 / 0.99| 75 / 0.99| 77 / 0.98| 67 / 0.97| 57 / 0.97| 46 / 0.96| 36 / 0.96| 26 / 0.95| 15 / 0.95
1/2″| 7/8″| 74| 25 / 1.00| 50 / 0.99| 75 / 0.99| 100 / 0.98| 100 / 0.97| 100 / 0.97| 100 / 0.96| 100 / 0.96| 99 / 0.95| 97 / 0.95
3/8″| 3/4″| 78| 25 / 0.99| 50 / 0.97| 75 / 0.94| 61 / 0.92| 46 / 0.90| NR| NR| NR| NR| NR
1/2″| 3/4″| 39| 25 / 0.99| 50 / 0.97| 75 / 0.94| 100 / 0.92| 100 / 0.90| NR| NR| NR| NR| NR
** 5 Ton| 3/8″| 7/8″| 78| 25 / 1.00| 50 / 0.99| 75 / 0.98| 61 / 0.97| 46 / 0.96| 32 / 0.95| 18 / 0.94| NR| NR| NR
1/2″| 7/8″| 39| 25 / 1.00| 50 / 0.99| 75 / 0.98| 100 / 0.97| 100 /0.96| 100 / 0.95| 97 / 0.94| 95 / 0.94| 92 / 0.93| 89 / 0.92
3/8″| 1-1/8″| 78| 25 / 1.01| 50 / 1.01| 75 / 1.00| 61 / 1.00| 46 / 0.99| 32 / 0.99| 18 / 0.99|
NR| NR| NR**
1/2″| 1-1/8″| 39| 25 / 1.01| 50 / 1.01| 75 / 1.00| 100 /1.00| 100 / 0.99| 100 / 0.99| 97 / 0.99| 95 / 0.99| 92 / 0.99| 89 / 0.98

NOTES:

  1. Do not exceed 61m linear line length.
  2. *Do not exceed 30m vertical separation if outdoor unit is above indoor unit.
  3. **19.05mm suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Performance Data

Performance Data @ AHRI Standard Conditions – Cooling

13.4 SEER2 Single-Stage Air Conditioners


**Unit Size**

| **Allowable Liquid Line Size mm [in.]| ****Allowable Suction Line Size mm [in.]| Apply Long Line Guidelines if Linear Line Length Exceeds Those Shown Below (Meters)| Equivalent Length (Meters)
< 8| 8-15| 16-23| 24-30| 31-38| 39-46| 47-53| 54-61| 62-69| 70-76
TZALNS13| Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) * / Capacity Multiplier
**
5.3 KW [1.5 Ton]

**SEE NOTE 3

| 6.35 [1/4]| 15.88 [5/8]| N/A| 8 / 1.00| 15 / 0.99| 19 / 0.98| 13 / 0.98| 7 / 0.97| 2 / 0.97| NR| NR| NR| NR
7.94 [5/16]| 15.88 [5/8]| N/A| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.98| 28 / 0.97| 27 / 0.97| 25 / 0.96| 24 / 0.96| 22 / 0.95| 21 / 0.94
9.53 [3/8]| 15.88 [5/8]| 54| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.98| 30 / 0.97| 30 / 0.97| 30 / 0.96| 30 / 0.96| 30 / 0.95| 30 / 0.94
6.35 [1/4]| 19.05 [3/4]| N/A| 8 / 1.00| 15 / 1.00| 19 / 0.99| 13 / 0.99| 7 / 0.99| 2 / 0.99| NR| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]
| N/A| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 28 / 0.99| 27 / 0.99| 25 / 0.99| 24 / 0.98| 22 / 0.98| 21 / 0.98
9.53 [3/8]| 19.05 [3/4]| 54| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.98| 30 / 0.98
**
7.0 KW [2 Ton]| 6.35 [1/4]| 15.88 [5/8]| N/A| 8 / 0.99| 15 / 0.98| 6 / 0.97| NR| NR| NR| NR| NR| NR| NR
7.94 [5/16]| 15.88 [5/8]| 65| 8 / 0.99| 15 / 0.98| 23 / 0.97| 27 / 0.96| 23 / 0.95| 21 / 0.94| 19 / 0.93| 16 / 0.92| 14 / 0.91| 11 / 0.90
9.53 [3/8]| 15.88 [5/8]| 43| 8 / 0.99| 15 / 0.98| 23 / 0.97| 30 / 0.96| 30 / 0.95| 30 / 0.94| 30 / 0.93| 29 / 0.92| 28 / 0.91| 27 / 0.90
6.35 [1/4]| 19.05 [3/4]| N/A| 8 / 1.00| 15 / 1.00| 6 / 0.99| NR| NR| NR| NR| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]| 65| 8 / 1.00| 15 / 1.00| 23 / 0.99| 27 / 0.99| 23 / 0.98| 21 / 0.98| 19 / 0.98| 16 / 0.97| 14 / 0.97| 11 / 0.96
9.53 [3/8]| 19.05 [3/4]| 43| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.98| 30 / 0.98| 29 / 0.97| 28 / 0.97| 27 / 0.96
** 8.8 KW [2.5 Ton]| 7.94 [5/16]| 15.88 [5/8]| N/A| 8 / 0.99| 15 / 0.98| 23 / 0.96| 21 / 0.94| 18 / 0.93| 15 / 0.91| 11 / 0.90| NR| NR| NR
9.53 [3/8]| 15.88 [5/8]| 43| 8 / 0.99| 15 / 0.98| 23 / 0.96| 30 / 0.94| 30 / 0.93| 29 / 0.91| 27 / 0.90|
NR| NR| NR
7.94 [5/16]| 19.05 [3/4]| 65| 8 / 1.00| 15 / 0.99| 23 / 0.99| 21 / 0.98| 18 / 0.98| 15 / 0.97| 11 / 0.96| 8 / 0.96| 4 / 0.95|
NR
9.53 [3/8]| 19.05 [3/4]| 43| 8 / 1.00| 15 / 0.99| 23 / 0.99| 30 / 0.98| 30 / 0.98| 29 / 0.97| 27 / 0.96| 26 / 0.96| 25 / 0.95| 24 / 0.95
**
10.6 KW [3 Ton]| 7.94 [5/16]| 15.88 [5/8]| N/A| 8 / 0.99| 15 / 0.97| 20 / 0.94| 15 / 0.92| 10 / 0.90| NR| NR| NR| NR| NR
9.53 [3/8]| 15.88 [5/8]| 33| 8 / 0.99| 15 / 0.97| 23 / 0.94| 29 / 0.92| 27 / 0.90| NR| NR| NR| NR| NR
7.94 [5/16]| 19.05 [3/4]| N/A| 8 / 1.00| 15 / 0.99| 20 / 0.98| 15 / 0.98| 10 / 0.97| 5 / 0.96| NR| NR| NR| NR
9.53 [3/8]| 19.05 [3/4]| 33| 8 / 1.00| 15 / 0.99| 23 / 0.98| 29 / 0.98| 27 / 0.97| 26 / 0.96| 24 / 0.95| 22 / 0.94| 20 / 0.93| 19 / 0.93
12.70 [1/2]| 19.05 [3/4]| 17| 8 / 1.00| 15 / 0.99| 23 / 0.98| 30 / 0.98| 30 / 0.97| 30 / 0.96| 30 / 0.95| 30 / 0.94| 30 / 0.93| 30 / 0.93
7.94 [5/16]| 22.23 [7/8]| N/A| 8 / 1.00| 15 / 1.00| 20 / 1.00| 15 / 0.99| 10 / 0.99| 5 / 0.99| NR| NR| NR| NR
9.53 [3/8]| 22.23 [7/8]| 33| 8 / 1.00| 15 / 1.00| 23 / 1.00| 29 / 0.99| 27 / 0.99| 26 / 0.99| 24 / 0.98| 22 / 0.98| 20 / 0.98| 19 / 0.97
12.70 [1/2]| 22.23 [7/8]| 17| 8 / 1.00| 15 / 1.00| 23 / 1.00| 30 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.98| 30 / 0.98| 30 / 0.97
** 12.3 KW [3.5 Ton]| 9.53 [3/8]| 19.05 [3/4]| 46| 8 / 0.99| 15 / 0.98| 23 / 0.97| 27 / 0.96| 24 / 0.95| 22 / 0.94| 20 / 0.92| 17 / 0.91| 15 / 0.90| NR
12.70 [1/2]| 19.05 [3/4]| 23| 8 / 0.99| 15 / 0.98| 23 / 0.97| 30 / 0.96| 30 / 0.95| 30 / 0.94| 30 / 0.92| 30 / 0.91| 30 / 0.90|
NR**
9.53 [3/8]| 22.23 [7/8]| 46| 8 / 1.00| 15 / 1.00| 23 / 0.99| 27 / 0.99| 24 / 0.99| 22 / 0.98| 20 / 0.97| 17 / 0.97| 15 / 0.96| 13 / 0.96
12.70 [1/2]| 22.23 [7/8]| 23| 8 / 1.00| 15 / 1.00| 23 / 0.99| 30 / 0.99| 30 / 0.99| 30 / 0.98| 30 / 0.97| 30 / 0.97| 30 / 0.96| 30 / 0.96

NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.
[ ] Designates Metric Conversions
Notes

GENERAL TERMS OF LIMITED WARRANTY*

Thermal Zone™ will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
*For complete details of the Limited and Conditional Warra nties, includingapplicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required) ……………………………Ten (10) Years
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.
“In keeping with its policy of continuous progress and product improvement, Thermal Zone reserves the right to make changes without notice.”

PRINTED IN U.S.A. 3/23 QG FORM NO. ATZ-338 REV. 3

Documents / Resources

| THERMAL ZONE TZALNS13 iM Air Conditioners [pdf] User Manual
TZALNS1318AJNA, TZALNS1318AJNALHP, TZALNS1324AJNA, TZALNS1324AJNALHP, TZALNS1330AJNA, TZALNS1330AJNALHP, TZALNS1336AJNA, TZALNS1336AJNALHP, TZALNS1342AJNA, TZALNS1342AJNALHP, TZALNS1348AJNA, TZALNS1348AJNALHP, TZALNS1360AJNA, TZALNS1360AJNALHP, TZALNS13 iM Air Conditioners, TZALNS13, iM Air Conditioners, Air Conditioners, Conditioners
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

THERMAL ZONE User Manuals

Related Manuals