THERMAL ZONE TZALAH1524AJNA Air Conditioners Instruction Manual

June 13, 2024
THERMAL ZONE

THERMAL ZONE TZALAH1524AJNA Air Conditioners

Product Information

  • Product Name: iM Air Conditioners
  • Model: TZALAH15
  • Cooling Efficiencies: up to 15.2 SEER2/9.8 EER2
  • Nominal Sizes: 2 to 5 Ton [7.0 to 17.6 kW]
  • Cooling Capacities: 22.8 to 56.0 kBTU [6.68 to 16.4 kW]
  • Manufacturer: Thermal ZoneTM
  • Manufactured in: Philadelphia, PA
  • Form Number: ATZ-336 REV. 3

Features and Benefits

  • 3-speed operation when installed with a 24V two-stage thermostat
  • Provides precise temperature control, advanced humidity control, and greater efficiency

Model Number Identification

TZALAH15

  • TZ – Thermal Zone
  • A – Air Conditioners
  • L – R-410A Refrigerant
  • A – All Region Type
  • H – 3+ Stage
  • 15.2 SEER2 – Major Series
  • 24 – 24,000 BTU/HR [7.03 kW] – Capacity
  • A – 1st Design
  • J – 208/230/1/60 Voltage
  • N – Non-Communicating Controls
  • A – 1st Design Minor Series

General Data

  • Model No.: TZALAH15
  • Nominal Tonnage: 2.0 to 5.0
  • Valve Connections: 3/8 to 7/8
  • Number of Blades: 3 to 24
  • Motor hp: 1/5 to 1/2
  • CFM: 2908 to 5274
  • RPM: 1075
  • Watts: 170 to 370

Electrical Data

  • Line Voltage Data (Volts-Phase-Hz): 208/230-1-60
  • Rated Load Amps: 10 to 25
  • Locked Rotor Amps: 65 to 119

Accessories

  • Compressor crankcase heater*
  • Low ambient control
  • Compressor sound cover
  • Low pressure control
  • High pressure control
  • Liquid Line Solenoid (24 VAC, 50/60 Hz)
  • Solenoid Valve Solenoid Coil
  • Liquid Line Solenoid (120/240 VAC, 50/60 Hz)
  • Solenoid Valve Solenoid Coil

Weighted Sound Power Level (dBA)

Unit Size Voltage, Series Standard Rating (dBA) Low Speed/High Speed
TZALAH1524 208/230-1-60 63.3 71.7
TZALAH1536 208/230-1-60 35.9 46.1
TZALAH1548 208/230-1-60 47.9 59.1
TZALAH1560 208/230-1-60 55.3 63.2

Note:

Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

Product Usage Instructions

  1. Ensure the air conditioner is properly installed and connected to the power supply.
  2. Set the desired temperature on the thermostat.
  3. If you have a 24V two-stage thermostat, you can take advantage of the 3-speed operation for enhanced temperature control.
  4. The air conditioner provides advanced humidity control for added comfort.
  5. The air conditioner operates with high efficiency, helping to save energy and reduce costs.

TZALAH15
Cooling Efficiencies up to: 15.2 SEER2/9.8 EER2
Nominal Sizes: 2 to 5 Ton [7.0 to 17.6 kW] Cooling Capacities: 22.8 to 56.0 kBTU [6.68 to 16.4 kW]

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks is under license.
Other trademarks and trade names are those of their respective owners.

Features and Benefits

  • Diagnostics & Bluetooth®1 Connectivity: With the BlueArch™ Contractor App, built-in technology makes advanced set-up, monitoring, troubleshooting and repairing the product easier than ever before
  • Variable Speed Twin Rotary Compressor & Inverter Drive:
    • Features Inverter operation from 40 to 70% capacity or 100% capacity via line voltage with the Smart Thermostat
    • 3-speed operation when installed with a 24V two-stage thermostat
    • Provides precise temperature control, advanced humidity control and greater efficiency
  • Swept Wing Fan Technology: Features quieter operation and improved unit acoustics
  • 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
  • Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space—provides a minimum working area of 27-square inches for easier access
  • Triple Service Access: 15 in. wide, industry leading corner service access, two fastener, removeable corner and individual louver panels–makes repairs easier and faster

Air Conditioners

THERMAL-ZONE-TZALAH1524AJNA-Air-Conditioners-1

Designates Metric Conversions

Available Models Description
TZALAH1524AJNA 2 ton 3+ Speed iM Air Conditioner – 208/230/1/60
TZALAH1536AJNA 3 ton 3+ Speed iM Air Conditioner – 208/230/1/60
TZALAH1548AJNA 4 ton 3+ Speed iM Air Conditioner – 208/230/1/60
TZALAH1560AJNA 5 ton 3+ Speed iM Air Conditioner – 208/230/1/60

Standard Equipment

R-410A Refrigerant
Variable Speed Twin Rotary Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays
General Data

Model No.| TZALAH1524| TZALAH1536| TZALAH1548| TZALAH1560
Nominal Tonnage| 2.0| 3.0| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 91| 119| 130| 154
Compressor Type| Twin Rotary
Outdoor Coil|
Net face area – Outer Coil| 11.79| 14.4| 16.42| 17.88
Net face area – Inner Coil| —| —| —| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276
Number of rows| 1| 1| 1| 1
Fins per inch| 24| 24| 24| 24
Outdoor Fan|
Diameter – in.| 20| 24| 24| 26
Number of blades| 3| 3| 3| 3
Motor hp| 1/5| 1/5| 1/3| 1/2
CFM| 2908| 4138| 4529| 5274
RPM| 1075| 1000| 1075| 1075
watts| 170| 267| 294| 370
Shipping weight lbs.| 174| 198| 230| 251
Operating weight lbs.| 167| 191| 223| 244
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60| 208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 30| 40| 50
Minimum circuit ampacity³| 12| 20| 25| 32
Compressor|
Rated load amps| 10| 15| 20| 25
Locked rotor amps| 65| 70| 96| 119

Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
²HACR type circuit breaker of fuse.
³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Accessories

Model No.| TZALAH1524| TZALAH1536| TZALAH1548| TZALAH1560
---|---|---|---|---
Compressor crankcase heater*| N/A| N/A| N/A| N/A
Low ambient control| 47-102709-10| 47-102709-10| 47-102709-10| 47-102709-10
Compressor sound cover| 68-23427-27| 68-23427-28| 68-23427-29| 68-23427-29
Low pressure control| 47-103454-01| 47-103454-01| 47-103454-01| 47-103454-01
High pressure control| 47-103669-02| 47-103669-02| 47-103669-02| 47-103669-02
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V

Crankcase Heater recommended with Low Ambient Kit.

Weighted Sound Power Level (dBA)

Unit Size – Voltage, Series| Standard Rating (dBA) Low Speed/ High Speed| TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)| Sound Power Level [dB(A)] with Sound Blanket
---|---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
TZALAH1524| 63.3| 35.9| 47.9| 55.3| 53.2| 50.4| 47.1| 43.8| ****



Sound Blankets – Standard

71.7| 46.1| 59.1| 63.2| 60.8| 58.7| 56.5| 47.9
TZALAH1536| 61.4| 38.5| 48.0| 53.8| 49.2| 45.9| 47.0| 47.4
72.9| 47.5| 59.5| 64.9| 60.7| 62.6| 57.0| 49.6
TZALAH1548| 63.8| 42.3| 45.9| 53.5| 48.9| 45.8| 59.1| 36.4
76.2| 49.4| 61.4| 68.1| 53.9| 60.8| 57.4| 48.5
TZALAH1560| 65.7| 39.7| 49.0| 58.2| 54.5| 52.2| 53.8| 41.3
76.7| 49.3| 64.6| 68.1| 65.1| 62.6| 58.6| 53.0

NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)

Unit Dimensions


Model No.

| Operating| Shipping
---|---|---
H (Height)| L (Length)| W (Width)| H (Height)| L (Length)| W (Width)
Inches| mm| Inches| mm| Inches| mm| Inches| mm| Inches| mm| Inches| mm
TZALAH1524| 27.00| 686| 29.75| 756| 29.75| 756| 28.50| 724| 32.38| 822| 32.38| 822
TZALAH1536| 27.00| 686| 33.75| 857| 33.75| 857| 28.50| 724| 36.38| 924| 36.38| 924
TZALAH1548| 31.00| 787| 33.75| 857| 33.75| 857| 32.50| 826| 36.38| 924| 36.38| 924
TZALAH1560| 31.00| 787| 35.75| 908| 35.75| 908| 32.50| 826| 38.38| 975| 38.38| 975

THERMAL-ZONE-TZALAH1524AJNA-Air-Conditioners-2

Designates Metric Conversions

CLEARANCES

THERMAL-ZONE-TZALAH1524AJNA-Air-Conditioners-3

NOTE: NUMBERS IN () = mm

IMPORTANT: When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re- circulation of discharge air.

Control Wiring

THERMAL-ZONE-TZALAH1524AJNA-Air-Conditioners-4

Application Guidelines

  1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
  2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C).
  3. Maximum outdoor operating air temperature is 125°F (51.7°C).
  4. For reliable operation, unit should be level in all horizontal planes.
  5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
  6. Do not apply capillary tube indoor coils to these units.
  7. Factory-supplied filter drier must be installed.

Refrigerant Line Size Information

15/16 SEER2 Variable Speed Air Conditioners




Unit Size

| ****


Allowable Liquid Line Size

| ****


Allowable Vapor Line Size

| Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Feet)
< 25| 26- 50| 51- 75| 76- 100| 101- 125| 126- 150
Maximum Vertical Separation/Capacity Multiplier



2.0 Ton*

SEE NOTE 3

| 1/4″| 5/8″| 25 / 1.00| 50 / 0.99| 32 / 0.98| 40 / 0.97| NR| NR
5/16″| 5/8″| 25 / 1.00| 50 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96| 50 / 0.95
3/8″| 5/8″| 25 / 1.00| 50 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96| 50 / 0.95
1/4″| 3/4″| 25 / 1.00| 50 / 1.00| 32 / 0.99| 40 / 0.99| NR| NR
5/16″| 3/4″
| 25 / 1.00| 50 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.99| 50 / 0.98
3/8″| 3/4″**| 25 / 1.00| 50 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.99| 50 / 0.98



3 Ton

| 5/16″| 5/8″| 25 / 0.99| 50 / 0.97| 50 / 0.95| 50 / 0.93| 37 / 0.91| NR
3/8″| 5/8″| 25 / 0.99| 50 / 0.97| 50 / 0.95| 50 / 0.93| 50 / 0.91| NR
5/16″| 3/4″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 37 / 0.97| 22 / 0.96
3/8″| 3/4″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96
1/2″| 3/4″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96



4 Ton

| 3/8″| 3/4″| 25 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96| 50 / 0.94| 50 / 0.93
1/2″| 3/4″| 25 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96| 50 / 0.94| 50 / 0.93
3/8″| 7/8″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 50 / 0.98| 50 / 0.97
1/2″| 7/8″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 50 / 0.98| 50 / 0.97



5 Ton

| 3/8″| 3/4″| 25 / 0.99| 50 / 0.97| 50 / 0.95| 50 / 0.93| 50 / 0.91| NR
1/2″| 3/4″| 25 / 0.99| 50 / 0.97| 50 / 0.95| 50 / 0.93| 50 / 0.91| NR
3/8″| 7/8″| 25 / 1.00| 50 / 0.99| 50 / 0.98| 50 / 0.98| 50 / 0.97| 38 / 0.96
1/2″| 7/8″| 25 / 1.00| 50 / 0.99| 50 / 0.98| 50 / 0.98| 50 / 0.97| 50 / 0.96
15/16 SEER2 Variable Speed Air Conditioners




Unit Size

| ****


Allowable Liquid Line Size mm [in.]

| ****


Allowable Vapor Line Size mm [in.]

| Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Meters)
< 25| 26- 50| 51- 75| 76- 100| 101- 125| 126- 150
Maximum Vertical Separation/Capacity Multiplier



2.0 Ton*

SEE NOTE 3

| 6.35 [1/4]| 15.88 [5/8]| 8 / 1.00| 15 / 0.99| 10 / 0.98| 10 / 0.97| NR| NR
7.94 [5/16]| 15.88 [5/8]| 8 / 1.00| 15 / 0.99| 15 / 0.98| 15 / 0.97| 15 / 0.96| 15 / 0.95
9.53 [3/8]| 15.88 [5/8]| 8 / 1.00| 15 / 0.99| 15 / 0.98| 15 / 0.97| 15 / 0.96| 15 / 0.95
6.35 [1/4]| 19.05 [3/4]| 8 / 1.00| 15 / 0.99| 10 / 0.99| 12 / 0.99| NR| NR
7.94 [5/16]| 19.05 [3/4]
| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.99| 15 / 0.99| 15 / 0.98
9.53 [3/8]| 19.05 [3/4]**| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.99| 15 / 0.99| 15 / 0.98



3 Ton

| 7.94 [5/16]| 15.88 [5/8]| 8 / 0.99| 15 / 0.97| 15 / 0.95| 15 / 0.93| 11 / 0.91| NR
9.53 [3/8]| 15.88 [5/8]| 8 / 0.99| 15 / 0.97| 15 / 0.95| 15 / 0.93| 15 / 0.91| NR
7.94 [5/16]| 19.05 [3/4]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 11 / 0.97| 7 / 0.96
9.53 [3/8]| 19.05 [3/4]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 15 / 0.97| 15 / 0.96
12.70 [1/2]| 19.05 [3/4]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 15 / 0.97| 15 / 0.96



4 Ton

| 9.53 [3/8]| 19.05 [3/4]| 8 / 0.99| 15 / 0.98| 15 / 0.97| 15 / 0.96| 15 / 0.94| 15 / 0.93
12.70 [1/2]| 19.05 [3/4]| 8 / 0.99| 15 / 0.98| 15 / 0.97| 15 / 0.96| 15 / 0.94| 15 / 0.93
9.53 [3/8]| 22.23 [7/8]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 15 / 0.98| 15 / 0.97
12.70 [1/2]| 22.23 [7/8]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 15 / 0.98| 15 / 0.97



5 Ton

| 9.53 [3/8]| 19.05 [3/4]| 8 / 0.99| 15 / 0.97| 15 / 0.95| 15 / 0.93| 15 / 0.91| NR
12.70 [1/2]| 19.05 [3/4]| 8 / 0.99| 15 / 0.97| 15 / 0.95| 15 / 0.93| 15 / 0.91| NR
9.53 [3/8]| 22.23 [7/8]| 8 / 1.00| 15 / 0.99| 15 / 0.98| 15 / 0.98| 15 / 0.97| 12 / 0.96
12.70 [1/2]| 22.23 [7/8]| 8 / 1.00| 15 / 0.99| 15 / 0.98| 15 / 0.98| 15 / 0.97| 15 / 0.97

NOTES:

  1. Do not exceed 150 ft. linear line length.
  2. *Do not exceed 50 ft. vertical separation if outdoor unit is above indoor unit.
  3. **3/4″ suction line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
  4. Always use the smallest liquid line allowable to minimize refrigerant charge.
  5. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  6. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.

Additional Oil, Oz.

Lineset Length| 50| 60| 70| 80| 90| 100| 110| 120| 130| 140| 150
2T| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6| 7
3T| N/A| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6
4T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A
5T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A

Performance Data @ AHRI Standard Conditions – Cooling

Designated Tested Combination (DTC)

Outdoor Unit| Air Handler| Total Capacity BTU/H [kW]| Net Sensible BTU/H [kW]| Net Latent BTU/H [kW]| SEER2| EER2| Indoor CFM [L/s]
TZALAH1524| TZHHLVST2417| 22,800 [6.7]| 17,600 [5.2]| 5,200 [1.5]| 15.2| 9.8| 750 [354.0]
TZALAH1536| TZHHLVST3617| 34,200 [10.0]| 26,600 [7.8]| 7,600 [2.2]| 15.2| 9.8| 1,125 [530.9]
TZALAH1548| TZHHLVST4821| 45,500 [13.3]| 35,500 [10.4]| 10,000 [2.9]| 15.2| 9.8| 1,425 [672.5]
TZALAH1560| TZHHLVST6024| 55,500 [16.3]| 43,000 [12.6]| 12,500 [3.7]| 15.2| 9.8| 1,675 [790.5]

NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.

Designates Metric Conversions

GENERAL TERMS OF LIMITED WARRANTY

Thermal Zone™ will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.

For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.

Conditional Parts
(Registration Required)……………………………… Ten (10) Years

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal,State, Provincial, and Local codes, regulations, and practices.
“In keeping with its policy of continuous progress and product improvement, Thermal Zone reserves the right to make changes without notice.”

PRINTED IN U.S.A. 4/23 QG FORM NO. ATZ-336 REV. 3