PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE USER / MAINTENANCE ENGINEER FOR FUTURE REFERENCE

IMPORTANT INSTALLATION INFORMATION

  • Installation should be carried out in accordance with the latest edition of the National Wiring Regulations. If in doubt consult a qualified electrician.
  • IMPORTANT. Constant Voltage LED lamps MUST be wired in PARALLEL.
  • PLEASE NOTE :12V DC Output ­ correct polarity must be observed in order for the Constant Voltage LED Lamps to operate.
  • Ensure that ALL electrical connections are tight with no loose strands. Use the table below to assist with calculating how many LED lamps may be used with the LED
  • Driver. Simply multiply the number of lamps by their respective wattage up to a MAX of 10W. It is possible to combine lamp types :

Lamp Type| Lamp Wattage| Min Number of Lamps per LED Driver| Max Number of Lamps per LED Driver
---|---|---|---
MR8| 0.3W 2| 2| 33
MR11| 0.4W| 1| 25
MR16| 1.2W| 1| 8

INSTALLATION INSTRUCTIONS

Isolate from the mains supply before installation or maintenance.
1. The mains supply should be connected to the Primary input terminals as follows:

Black/Blue – Neutral
Red/Brown – Live
Green & Yellow – Earth| Input terminals.
Dual Live and Neutral terminals allow loop-in
loop-out wiring between LED drivers|
---|---|---

IMPORTANT Constant Voltage LED lamps MUST be wired in Parallel. Ensure the connection of the lamps to the 12V DC supply is correct. Polarity is indicated on the LED driver and on all Constant Voltage LED Lamps.

Illustration of wired in Parallel

CORRECT Installation
Keep the LED Driver away from direct sources of heat such as Low Voltage lamps
INCORRECT Installation
Do not fit the LED Driver above the luminaire
Environmental Protection (W.E.E.E.) ­ Aurora’s WEEE Reg.No. WEE/BG0130YX (the UK only)
**** Waste Electrical & Electronic Equipment Regulations (WEEE) require that any of our products showing this marking (left) must not be disposed of with other household or commercial waste. Aurora does not levy any WEEE disposal charges to its customers for affected WEEE-related products. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate any such product from other waste types and recycle it responsibly at your local facilities. Check with your Local Authority, Recycling Centre or retailer for recycling advice. If, when you purchased any Aurora product, your supplier included a WEEE disposal fee, you should then contact your supplier for advice on his take-back of the product for the correct disposal.

Warranty

See www.auroralighting.com for full details of warranties and Extended Warranty Terms and Conditions. The warranty is invalid in the case of improper use, tampering, and removal of the Q.C. date label, installation in an improper working environment or installation not according to the current edition of the National Wiring Regulations. Should this product fail during the warranty period it will be replaced free of charge, this is subject to correct installation and return of the faulty product. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in your country of purchase. Aurora reserves the right to alter specifications without prior notice.

Aurora Limited 16 Alban Park
Hatfield Road St Albans Hertfordshire AL4 0JJ
United Kingdom