Product Information
- Product Name : HCTV5, H, HR, HCVAC7 Vacuum Series
- Series: High Capacity Series
- Approvals: CE Approved, RoHS2 Compliant, EAC
- Caution : Do not dump and re-use filter. This will damage the vacuum and void the warranty.
- Warning : Do not use on any wet material in a wet environment. This unit is designed for dry products only.
Important Safety Instructions
When using an electrical appliance, basic precautions should always be followed, including the following:
- Do not leave the appliance plugged in. Unplug from outlet when not in use and before servicing.
- Do not use it outdoors or on wet surfaces.
- Do not allow to be used as a toy. Close attention is necessary when used by or near children.
- Use only as described in this manual. Use only the manufacturer’s recommended attachments.
- Do not use with a damaged cord or plug. If the appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped in water, return it to a service center.
- Do not pull or carry by cord, use the cord as a handle, close the door on the cord, or pull the cord around sharp edges or corners. Do not run the appliance over the cord. Keep the cord away from heated surfaces.
- This appliance should not be used by individuals with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Grounding Instructions
This appliance must be grounded. If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This appliance is equipped with a cord having an
equipment-grounding conductor and grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded by all
local codes and ordinances.
Warning: Improper connection of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlet is properly grounded. Do
not modify the plug provided with the appliance – if it will not fit the
outlet, have a proper outlet installed by a qualified electrician.
These models are for use on a nominal 120-volt circuit and have a grounding
plug. Make sure that the appliance is connected to an outlet having the same
configuration as the plug. No adapter should be used with this appliance. 230V
models are available upon request.
Assembly of the High-Capacity Vacuum
- Remove all parts from the shipping container.
- The filter is shipped already attached to the motor bulkhead.
- Insert either end of the hose into the vacuum intake. Any accessory may be used at this time.
- Insert the detachable power cord into the vacuum head and insert the other end into the grounded wall outlet.
- The High Capacity Vacuum is now ready for use.
- Assemble the roller base and use for extra mobility.
Caution : do not dump and re-use the filter. This will damage the vacuum,
and void the warranty.
High Capacity Fine Particle Vacuum (This unit is intended for commercial
use only. Read all instructions before using this appliance.)
Warning : Do not use on any wet material in a wet environment. This unit
is designed for dry products only.
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be
followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK OR INJURY
- Do not leave the appliance when plugged in. Unplug from outlet when not in use and before servicing.
- Do not use it outdoors or on wet surfaces.
- Do not allow to be used as a toy. Close attention is necessary when used by or near children.
- Use only as described in this manual. Use only the manufacturer’s recommended attachments.
- Do not use with a damaged cord or plug. If the appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped in water, return it to a service center.
- Do not pull or carry by cord, use cord as a handle, close the door on the cord, or pull cord around sharp edges or corners. Do not run the appliance over the cord. Keep the cord away from heated surfaces.
- Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
- Do not handle plug or appliances with wet hands.
- Do not put any objects into openings. Do not use any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
- Keep hair, loose clothing, fingers, and all parts of the body away from opening and moving parts.
- Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.
- Do not use without a filter in place.
- Turn off all controls before unplugging
- Use extra care when cleaning on stairs.
- Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
- Connect to a properly grounded outlet. See grounding instructions.
- Do not attempt to dump and re-use filters, this will damage the filter media, and will cause damage to result to your vacuum cleaner.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
GROUNDING INSTRUCTIONS
This appliance must be grounded. If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This appliance is equipped with a cord having an
equipment-grounding conductor and grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Warning : Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualified electrician or
service person if you are in doubt as to whether the outlet is properly
grounded. Do not modify the plug provided with the appliance-if it will not
fit the outlet, have a proper outlet installed by a qualified electrician.
These models are for use on a nominal 120-volt circuit and has a grounding
plug. Make sure that the appliance is connected to an outlet having the same
configuration as the plug. No adapter should be used with this appliance. 230V
models are available upon request.
GENERAL INFORMATION
ASSEMBLY OF THE HIGH-CAPACITY VACUUM
- Remove all parts from the shipping container.
- Filter is shipped already attached to motor bulkhead.
- Insert either end of the hose into the vacuum intake. Any accessory may be used at this time.
- Insert the detachable power cord into the vacuum head and insert other end into the grounded wall outlet.
- The High Capacity Vacuum is now ready for use.
- Assemble roller base and use for extra mobility.
FILTER REPLACEMENT
- Remove the power cord from the power source.
- Unfasten retaining clips (3) from the vacuum head. Lift the vacuum head off of the filter.
- Place filter lid securely on the filter. The filter is now ready for disposal.
- Apply new filter below vacuum head and fasten (3) retaining clips.
- Plug the power cord in the power source.
- Dispose of the filter cartridge in an appropriate manner compliant with all local, state, and federal laws.
NOTE : These vacuums have a factory-installed resettable Thermal Cutout (TCO) for added operator and motor safety. If the unit gets too hot, the vacuum will shut down for approx. 20 minutes. Turn the on/off switch to the off position, and turn back on in approximately 20 minutes. Your hose may be clogged, or it may be time to install a new filter.
WARRANTY
WARRANTY SERVICE INFORMATION:
For warranty service information, please contact your local distributor. The
warranty period for the High Capacity Series is 18 months. When using the
standard Atrix filter for removing toner, developer, dirt, dust and other NON-
hazardous waste, the vacuum can be serviced. When using the Atrix HEPA filter
for removing lead or other hazardous waste, the vacuum CANNOT be serviced.
Field replacement parts will be made available to the user for the duration of
the warranty period. This warranty is in lieu and exclusive of any warranty of
merchantability, and/or quality, and any application for use for a particular
purpose. No other warranties expressed or implied are granted or acknowledged
by Atrix International.
EXCLUSIVE TO WARRANTY:
Accessories, filters, motor brushes, and damage to the vacuum caused by
accident, misuse or negligence are not covered by the above warranty. Filters
and replacement filters are intended for single use only. Attempting to re-use
the filter by dumping the contents may cause damage to the vacuum, and will
void the warranty. Atrix shall not be liable for special or coincidental
damages such as loss of other property or equipment, loss of revenue, personal
injury, death or inconvenience, but not limited to the above examples. Atrix
assumes only liability for the cost of its vacuum systems and what is
expressly stated in this warranty
Standard/Replacement Parts
- Vacuum Head (Power Unit) 421-000-100 (120 Volt) 421-000-101 (230 volt)
- Filter Replacement, toner, developer, dust and dirt-5 Gallon 421-000-002
- Filter Replacement, HEPA-5 Gallon 421-000-005
- Detachable Power Cord 10’ office machine end, 110V 31651
- ESD Safe Round Dusting Brush 31653
- 8’2” European Power Cord, 230V 66021A
- 8’2” U.K. Power Cord, 230V 66097A
- Vacuum Roller Base 421-000-105
- Toner proof Stretch hose, 10’ ESD Safe 31671
- Toner Proof Stretch Hose, 16’ ESD Safe 31681
- Clear Hose, 9’ AVPA009
- Hose adapter, connect two hoses for longer length ESD Safe SCHENG600
- Utility Nozzle AVPA011
- Utility Nozzle Brush AVPA017
- Crevice Tool ESD Safe 31654
- Crevice Tool Brush, brush that fits in the crevice tool 31652
- Rubber Flex Neck, 16” long, angled neck, soft rubber ESD Safe 31657
- Foot Switch, for hands free operation (110V only) 420-000-013
Accessory kit, allows user to vacuum floors and large areas ATIVACACC Includes: (Two 20” straight wands, 11” curved neck, 10” carpet wand, 10” horsehair floor brush, vinyl accessory caddy) Non-ESD Safe
To Register your Warranty
Visit : www.atrix.com
ATRIX INTERNATIONAL, INC. 1350 Larc Industrial Boulevard Burnsville, MN
55337-1412
Telephone: 952-894-6154
800-222-6154
Fax : 952-894-6256
Manual : 999403
E-mail: Sales@Atrix.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>