ZURN 950XL Double Check Valve Installation Guide

June 13, 2024
ZURN

ZURN 950XL Double Check Valve

ZURN-950XL-Double-Check-Valve-PRODUCT

Product Information

  • Model: 950XL
  • Product: Double Check Valve Assembly
  • Application: Designed for installation on water lines to protect against both back siphonage and backpressure of polluted water into the potable water supply. Assembly provides protection where a potential health hazard does not exist.
  • Materials:
    • Main valve body: Cast Bronze ASTM B 584
    • Access covers: Cast Bronze ASTM B 584
    • Internals: Stainless Steel, 300 Series
    • Elastomers: Silicone (FDA approved)
    • Polymers: Buna Nitrile (FDA approved)
    • Springs: NorylTM
  • Options:
    • with full port QT ball valves (standard)
  • Accessories:
    • Repair kit (rubber only)
    • Thermal expansion tank (Model XT)
    • QT-SET Quick Test Fitting Set
  • Features:
    • Sizes: 3/4, 1, 1 1/2, 2
    • Maximum working water pressure: Not specified
    • Maximum working water temperature: Not specified
    • Hydrostatic test pressure: Not specified
    • End connections: Threaded

Product Usage Instructions

Local codes shall govern installation requirements. To be installed in accordance with the manufacturer’s instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12″ (305mm) and a maximum of 30″ (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

Ensure that the direction of flow is correctly indicated during installation. For outdoor installations, a protective enclosure should be provided by others.

Capacity through Schedule 40 Pipe:

Pipe Size| Capacity at 5 ft/sec| Capacity at 7.5 ft/sec| Capacity at 10 ft/sec| Capacity at 15 ft/sec
---|---|---|---|---
1/8″| 3| 5| 9| 14
1/4″| 25| 40| 70| 95
3/8″| 167| | |
1/2″| 1| 1| |
3/4″| 2| 2| |
1″| 2| 3| |
1 1/4″| 2| 4| |
1 1/2″| 2| 6| |
2″| 3| 8| |

Note: The product manual does not provide specific information on maximum working water pressure, maximum working water temperature, or hydrostatic test pressure. Please refer to additional documentation or contact the manufacturer for this information.

Application
Designed for installation on water lines to protect against both back siphonage and backpressure of polluted water intothe potable water supply. Assembly shall provide protection where a potential health hazard does not exist.

Standards Compliance

(All sizes approved horizontal. Vertical approvals as listed below.)

  • ASSE® Listed 1015 ( vertical 3/4”, 1 1/2” & 2”)
  • cUPC® Listed (vertical 1 1/2”, 2”)
  • CSA® Certified B64.5 ( vertical 3/4”, 1 1/2” & 2”)
  • AWWA Compliant C510 (vertical 3/4”)
  • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (vertical 3/4”)
  • City of Los Angeles Approved (vertical 1 1/2″, 2″)
  • NYC MEA 426-89-M VOL 3

Options

(Suffixes can be combined)

  • with full port QT ball valves (standard)

Materials

  • Main valve body: Cast Bronze ASTM B 584
  • Access covers: Cast Bronze ASTM B 584
  • Internals: Stainless Steel, 300 Series
  • Elastomers: Silicone (FDA approved) Buna Nitrile (FDA approved)
  • Polymers: Noryl™
  • Springs: Stainless steel, 300 series

Accessories

  • Repair kit (rubber only)
  • Thermal expansion tank (Model XT)
  • QT-SET Quick Test Fitting Set

Features

Sizes: 3/4″, 1″, 1 1/2″, 2″

  • Maximum working water pressure: 175 PSI
  • Maximum working water temperature: 180°F
  • Hydrostatic test pressure: 350 PSI
  • End connections Threaded: ANSI B1.20.1ZURN-950XL-Double-Check-Valve-FIG-1

Dimensions

MODEL SIZE

| DIMENSIONS (approximate)|
---|---|---
A| B LESS BALL VALVES| C| D| E| F| WITH BALL VALVES
in.| mm| in.| mm| in.| mm| in.| mm| in.| mm| in.| mm| in.| mm| lbs.| kg
3/4| 20| 11 1/4| 286| 7| 178| 1 1/2| 38| 3| 76| 3 1/2| 89| 3| 76| 7| 3.2
1| 25| 12 1/4| 311| 7| 178| 1 1/2| 38| 3| 76| 3 1/2| 89| 3| 76| 12| 5.4
1 1/2| 40| 17 1/8| 435| 10 9/16| 268| 2| 51| 3 1/2| 89| 4 1/2| 114| 4 1/2| 114| 22| 10
2| 50| 18 1/4| 460| 10 9/16| 268| 2| 51| 3 1/2| 89| 4 1/2| 114| 4 1/2| 114| 28| 12.7

  • Size 1-1/4″ Discontinued

Flow Characteristics

  • Rated Flow (established by approval agencies)

MODEL 950XL 3/4″, 1″, 1 1/2″ & 2″ (STANDARD & METRIC)ZURN-950XL-Double-
Check-Valve-FIG-2

Typical Installation

Local codes shall govern installation requirements. To be installed in accordance with the manufacturer’s instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12” (305mm) and a maximum of 30” (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

Capacity thru Schedule 40 Pipe

Pipe size| 5 ft/sec| 7.5 ft/sec| 10 ft/sec| 15 ft/sec
1/8″| 1| 1| 2| 3
1/4″| 2| 2| 3| 5
3/8″| 3| 4| 6| 9
1/2| 5| 7| 9| 14
3/4″| 8| 12| 17| 25
1″| 13| 20| 27| 40
1 1/4″| 23| 35| 47| 70
1 1/2″| 32| 48| 63| 95
2″| 52| 78| 105| 167

OUTDOOR INSTALLATIONZURN-950XL-Double-Check-Valve-
FIG-3

INDOOR INSTALLATION

Specifications

The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be Noryl™ and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the device from the line. The Double Check Valve Backflow Preventer shall be a ZURN WILKINS Model 950XL.