INTELLINET 561969 IPS-54GM06-10G 450W 54 Port L2 Fully Managed PoE Switch Instructions
- June 13, 2024
- INTELLINET
Table of Contents
INTELLINET 561969 IPS-54GM06-10G 450W 54 Port L2 Fully Managed PoE Switch
- This guide presents the basic steps to set up and operate this device.
- For the user manual and specifications, visit intellinet-network.com.
- Register your product at register.intellinet-network.com/r/561969 or scan the QR code on the cover.
Placement
Prior to use, it is recommended that the switch be placed/positioned:
- on a level surface that can support the weight of the switch (and any other items that need to be considered);
- with a minimum of 25 mm (approx. 1”) of clearance on the top and sides for adequate ventilation;
- away from sources of electrical noise: radios, transmitters, broadband amplifiers, etc.;
- where it cannot be affected by excessive moisture;
- within 100 m (approx. 328’) of network devices it’s to be connected to.
The switch includes brackets and screws for optional rack mounting.
- Disconnect any cables from the switch.
- Position a bracket over the mounting holes on one side of the switch and secure it in place with screws.
- Repeat Step 2 on the other side of the switch.
- Position the switch in the rack and screw the brackets to the rack.
- Reconnect any cables.
Chassis Ground Column
Located on the side of the power supply connector, a grounding terminal
connector is used to provide proper grounding for your Intellinet Network
Solutions switch. If you use the chassis grounding screw, it should be wired
to an object that provides earth ground. In rackmount installations, grounding
is typically provided by the metal frame of the mounting rack.
Connections
- All ports on the switch support Auto-MDI/MDI-X functionality, so you can use straight or crossover UTP/STP cables to connect the RJ45 ports to PCs, routers, hubs, other switches, etc.
- Cat5e/6/6a/8.x UTP/STP cables provide optimal performance; if a status LED doesn’t indicate a link or activity, check the corresponding device for proper setup and operation.
- Use the included power cable to connect the receptacle on the back of the switch to a power outlet.
LED | Color | Status | Operation |
---|---|---|---|
PWR | Green | Flashing | The LEDs of ports 1 – 48 are showing PoE status. |
Off | The LEDs of ports 1 – 54 are showing Link status. | ||
RUN | Green | Flashing | The system is booting. |
On | The system has been booted successfully. |
1–48
**Link/ PoE***
|
Green
| On| Valid port connection. / The connected device (PD) is receiving power.
Flashing| Data transmitted/received.
Off| No link was established. / No powered device (PD) is connected to the
port.
49S–54S (SFP+)|
Green
| On| Valid port connection.
Flashing| Data transmitted/received.
Off| No link was established.
NOTE: Press the CTRL button to alternate between Link or PoE Status.
Basic Web-Based Browser Management
- Open your Web browser.
- Enter http:// and the IP address of the switch in the Address field. The default management IP address is 192.168.2.1.
- Press Enter to display the login screen. In the Username field, enter admin; in the Password field, enter the serial number on the bottom of the switch. Click OK.
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
DISPOSAL OF ELECTRIC AND ELECTRONIC EQUIPMENT (Applicable In The European Union And Other European Countries With Separate Collection Systems)
- This symbol on the product or its packaging means that this product must not be treated as unsorted household waste.
- In accordance with EU Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE), this electrical product must be disposed of in accordance with the user’s local regulations for electrical or electronic waste.
- Please dispose of this product by returning it to your local point of sale or recycling pickup point in your municipality.
WARRANTY
IN MEXICO: Intellinet Network Solutions Guarantee Policy — Data of the
importer and person responsible
before the consumer • IC Intracom México, S.A.P.I. of C.V. • Av. Interceptor
Poniente # 73, Col. Parque
Industrial La Joya, Cuautitlán Izcalli, State of Mexico, C.P. 54730, Mexico. •
Tel. (55)1500-4500 This warranty covers the following products against any
manufacturing defect in materials and workmanship.
- A: We guarantee cleaning products, compressed air, and consumables, for 60 days from the delivery date, or for the time in which it is completely sold out its content by its own function of use, whichever comes first.
- B: We guarantee products with moving parts for 3 years.
- C: We guarantee other products for 5 years (products without moving parts), under the following conditions:
- All products referred to in this guarantee cover their physical change, without any charge to the consumer.
- The marketer does not have service workshops, because the products that are guaranteed do not have repairs or spare parts, since their guarantee is for physical change.
- The warranty covers exclusively those parts, equipment or sub-assemblies that have been installed at the factory and does not include in any case additional equipment or any that have been added to it by the user or distributor.
To make this guarantee effective, it will be enough to present the product to the distributor at home. where it was acquired or at the address of IC Intracom México, S.A.P.I. de C.V., along with accessories contained in its packaging, accompanied by your policy duly filled out and sealed by the house seller (the stamp and date of purchase are essential) where it was purchased, or the invoice or receipt of original purchase clearly mentioning the model, serial number (when applicable) and date of acquisition. This guarantee is not valid in the following cases: If the product has been used in conditions other than normal; if the product has not been operated in accordance with the instructions for use; or if the product has been altered or attempted to be repaired by the consumer or third parties.
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Any changes or modifications made to this equipment without the approval of the manufacturer could result in the product not meeting the Class A limits, in which case the FCC could void the user’s authority to operate the equipment.
- This device complies with the requirements of CE 2014/30/EU (UKCA Electromagnetic Compatibility Regulations 2016) and/or 2014/35/EU (UKCA Electrical Equipment [Safety] Regulations 2016). The Declaration of Conformity is available at:
- support.intellinet-network.com/barcode/561969
CONTACT
North America
- IC Intracom America
- 550 Commerce Blvd.
- Oldsmar, FL 34677 USA
Asia & Africa
- IC Intracom Asia
- 4-F, No. 77, Sec. 1, Xintai 5th Rd.
- Xizhi Dist., New Taipei City 221, Taiwan
Europe
- IC Intracom Europe
- Löhbacher Str. 7, D-58553
- Halver, Germany
All trademarks and trade names are the property of their respective owners.
All trademarks and trade names are the property of their respective owners. ©
IC Intracom. All rights reserved.
Intellinet Network Solutions is a trademark of IC Intracom, registered in the
U.S. and other countries.
Scan to register your product warranty
- or go to: register.intellinet-network.com/r/561969
References
- Intellinet Network Solutions - Provider of PoE and Data Center Product
- Intellinet Network Solutions Account and Product Registration
- Intellinet Network Solutions Account and Product Registration
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>