INTELLINET IIS-4G02POE-240W Industrial 4 Port Gigabit Ethernet PoE++ Switch with 2 SFP Ports Instructions
- June 2, 2024
- INTELLINET
Table of Contents
INTELLINET IIS-4G02POE-240W Industrial 4 Port Gigabit Ethernet PoE++
Switch with 2 SFP Ports
For additional benefits:
Scan to register your product warranty or go to: register.intellinet-
network.com/r/508995
The Intellinet Industrial 4-Port Gigabit Ethernet PoE++ Switch with 2 SFP
Ports offers an array of time-saving, cost-effective features while providing
superior network throughput. No configuration is required and installation is
plug and play.
Features
- Provides power and data connections for up to four PoE network devices
- IP40 slim-type metal housing to withstand harsh industrial conditions
- Wide operating temperature: -20 – 75°C (4 – 167°F)
- Option for DIN-rail installation
- Two small form-factor pluggable GBIC module slots (SFP)
- Two redundant DC inputs (48 – 57 V) with I/O terminal block
With a backplane speed of 12 Gbps, plenty of performance is available for your computers, servers and other networking devices. Each of the ports automatically senses the link speed of the connected network device and adjusts to 10, 100 or 1000 Mbps for compatibility and maximum performance. This PoE switch is designed to provide compatible devices with enough power when needed. It offers up to 95 watts of power per port until its power budget of 240 watts is reached. For specifications, visit intellinetnetwork.com. Register your product at register. intellinet-network.com/r/508995 or scan the QR code on the cover.
Placement
Desktop Installation
Prior to use, place/position the switch:
- on a level surface that can support the weight of the switch and that offers at least 25 mm (approx. 1”) of clearance for ventilation;
- away from sources of electrical noise: radios, transmitters, broadband amplifiers, etc.;
- within 100 m (approx. 328’) of network devices it’s to be connected to.
DIN-Rail Installation
- With DIN-rail bracket attached to device with screws, angle bracket onto DIN rail.
- Push device in till it clicks into place.
Power
Chassis Ground Column
Located on the side of the power supply connector, a grounding terminal
connector is used to provide proper grounding for your Intellinet Network
Solutions switch. It should be wired to an object that provides earth ground.
Terminal Block Installation
NOTE: Ensure all power is off/disconnected before beginning!
- Loosen appropriate screws.
- Insert bare power-supply wires into appropriate terminals (positive wire into positive terminal; negative wire into negative terminal).
- Tighten appropriate screws to secure wires. (If desired, repeat steps 1 – 3 on second input pair.)
- Install block into the device and tighten screws.
Front Panel
LED| Color| Status| Status Description|
---|---|---|---|---
PWR| Green| On| Power on|
Off| Power off|
Link 1 – 4| Yellow| On| Valid port connection|
Blinking| Sending or receiving data|
SFP 1 & 2| Green|
Off| No link established.|
PoE 1 – 4| Green| On| The connected Powered Device (PD) is receiving
power.|
Off| No PD is linked.|
Cat5e/6/6a/8.x UTP/STP cables provide optimal performance; if a status LED doesn’t indicate a link or activity, check the corresponding device for proper setup and operation.
WASTE ELECTRICAL & ELECTRONIC EQUIPMENT
DISPOSAL OF ELECTRIC AND ELECTRONIC EQUIPMENT
(Applicable In The European Union And Other European Countries With Separate
Collection Systems)
This symbol on the product or its packaging means that this product must not
be treated as unsorted household waste. In accordance with EU Directive
2012/19/EU on Waste Electrical and Electronic Equipment (WEEE), this
electrical product must be disposed of in accordance with the user’s local
regulations for electrical or electronic waste. Please dispose of this product
by returning it to your local point of sale or recycling pickup point in your
municipality.
WARRANTY INFORMATION
REGULATORY STATEMENTS
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of Federal Communications Commission
(FCC) Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions may cause harmful interference to
radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: reorient or relocate
the receiving antenna; increase the separation between the equipment and the
receiver; connect the equipment to an outlet on a circuit different from the
receiver; or consult the dealer or an experienced radio/TV technician for
help.
CE
This device complies with the requirements of CE 2014/30/EU and / or
2014/35/EU. The Declaration of Conformity for is available at:
support.intellinet-network.com/barcode/508995 All trademarks and trade names are the property of
their respective owners.
References
- Intellinet Network Solutions - Provider of PoE and Data Center Product
- Intellinet Network Solutions - Provider of PoE and Data Center Product – Intellinet Solutions
- DropCatch.com
- Intellinet Network Solutions Account and Product Registration
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>