westfalia 945307 2 in 1 Digital Hygro Thermometer with Mold Alert Instruction Manual
- June 13, 2024
- Westfalia
Table of Contents
Westfalia 945307 2 in-1 Digital Hygro Thermometer with Mold Alert
Product Information
The Hygro-/Thermometer with Mold Alert (Article No. 94 53 07) is a device that measures and displays the temperature and humidity levels in the indoor environment. It also features a mold alert function that warns users when the humidity reaches a certain threshold. The device has a display screen that shows various information such as the current temperature, humidity percentage, comfort index, and alarm status. It is powered by two LR03 (AAA)batteries and comes with a suspension opening for wall mounting.
Key Features:
- Temperature and humidity measurement
- Mold alert function
- Comfort index indication
- MAX/MIN temperature and humidity display
- Graphical representation of humidity levels
- Battery status indication
- Alarm signal with LED indicator
Product Usage Instructions
Setup and Installation
- Choose an appropriate location for the device, avoiding direct sunlight and adverse environmental conditions.
- If wall mounting, ensure there are no electrical cables or gas pipes behind the chosen spot.
- Insert two new LR03 (AAA) batteries into the battery compartment.
Humidity Alarm Setup
To set the humidity alarm:
- Press the SET button to enter the alarm setting mode.
- Use the appropriate buttons to adjust the desired humidity value.
- Once the desired value is set, press the SET button again to confirm.
Activating/Deactivating the Humidity Alarm
To activate or deactivate the humidity alarm:
- Press and hold the ON/OFF button for the alarm.
- The alarm will be activated or deactivated, as indicated by the LED alarm signal.
Note: The alarm will blink for 1 minute when activated. Press the ON/OFF button again to stop the alarm.
Temperature Display Setting
To switch between Celsius and Fahrenheit temperature units:
Press the MAX/MIN button to toggle between the temperature units.
Mold Alert Setup
To set the mold alert value:
The default mold alert value is 65% humidity.
- Enter the mold alert setting mode.
- Adjust the desired humidity value using the appropriate buttons.
- Press the SET button to confirm the setting.
Graphical Representation of Humidity
The device provides a graphical representation of humidity levels over a 12-hour period.
Comfort Index
The comfort index indicates the comfort level based on the relative humidity:
- Too wet: 81% to 90%
- Wet: 61% to 80%
- Comfort: 41% to 60%
- Dry: 31% to 40%
- Too dry: 20% to 30%
Additional Information
The device also displays the dew point temperature, which indicates the temperature at which condensation occurs. It is important to maintain a healthy indoor environment.
The Hygro-/Thermometer with Mold Alert has the following technical specifications:
- Batteries: 2x LR03 (AAA)
- Humidity deviation: +/- 5%
- Dimensions: 120 x 86 x 21 mm
- Weight (without batteries): 102 g
For more detailed usage instructions and safety information, please refer to the user manual.
Dear Customers
Instruction manuals provide valuable hints for using your new device. They enable you to use all functions, and they help you avoid misunderstandings and prevent damage. Please take the time to read this manual carefully and keep it for future reference.
Overview
1 | Display | Display |
---|---|---|
2 | SET-Taste | SET Button |
3 | ON/OFF-Taste für Alarm | ON/OFF Button for Alarm |
4 | Alarmsignal | Alarm Signal |
5 | °C/°F-Taste | °C/°F Button |
6 | MAX/MIN-Taste | MAX/MIN Button |
7 | Standfuß | Stand |
8 | Aussparung f. Wandbefestigung | Suspension Opening |
9 | Batteriefach | Battery Compartment |
Safety Notes
Please note the following safety notes to avoid malfunctions, damage or physical injury:
- Use the device only indoors.
- This device may be used by children 8 years of age or older and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been supervised or instructed in the safe use of the device and understand the hazards arising therefrom.
- Children are not allowed to play with the device.
- Do not immerse the device in water or other liquids.
- Remove the batteries from the battery compartments if they are empty or if you are not using the device for an extended period.
- When changing batteries ensure correct polarity (+/-).
- Do not expose the article to direct sunlight, humidity, dust, extreme heat, hot light sources or strong magnetic fields.
- Avoid strong mechanical stresses and do not press on the LC display. Do not expose the unit to strong vibrations.
- Remove the batteries from the battery compartment if you do not intend to use it for a longer period of time.
- Do not disassemble, burn, or short-circuit batteries. Do not mix fresh batteries and spent batteries.
- Do not disassemble the unit and do not try to repair it yourself. In case of problems or questions turn to our customer service.
Batteries and rechargeable batteries do not belong in household garbage. For battery disposal, please check with your local council.
Operation
Before first Use
Remove it from the packaging and check it for damage in transit.
Remove the foil from the surfaces!
Keep packaging materials out of reach of small children. There is
risk of suffocation!
Location
- Select a setup location in a closed room.
- Handle the article with care. It can be damaged by impacts, blows, or accidental drops, even from a low height. Avoid strong vibrations and magnetic fields (in the vicinity of machinery or loudspeakers).
- Avoid unfavorable conditions when installing the article, such as: excessive humidity or dampness (e.g. bathroom), extreme cold or heat, dust, flammable gases, fumes or solvents.
- When mounting the article on a wall make sure to check for electric wires, gas or water pipes inside the wall. Otherwise, there is a danger of electric shock when drilling the holes.
- The article comes with a fold-out foot on the rear and a slot for wall mounting.
- If possible select a position in which the article is not exposed to direct sunlight.
- For easier handling and operation set the article up on ist foot(7). Open the foot carefully.
Intended Use
The article is intended to measure temperature and humidity inside rooms. The
article is only intended for domestic use and not for commercial operation.
Inserting the Batteries
- Open the battery compartment (9) at the rear side of the unit and insert two new 1.5 V batteries of the type LR03 (AAA) into the battery compartment. Pay attention to the proper polarity of the batteries. All available icons appear for several seconds on the display for confirmation and you will hear a signal sound.
- Close the battery compartment with the cover. Replace both batteries if the display gets weaker.
Setting the Humidity Alarm
Press and hold the SET Button| Symbols ALERT and appear in the
Display and the Humidity Display flashes
---|---
Press or| Set the upper Threshold Value in 5% Steps
Press the SET Button| Symbols ALERT and appear in the Display and the
Display flashes
Press or| Set the lower Threshold Value in 5% Steps
Press the SET Button and wait for 10 Sec| The display returns to normal
Mode
Press the ON/OFF Button| Activate or deactivate the Humidity Alarm
- As soon as the humidity rises over or falls under the threshold values set by you the respective symbol and the red LED alarm signal flash simultaneously.
- The alarm flashes for 1 minute. To end the alarm press any button.
- To deactivate the humidity alarm briefly press the ON/OFF buttons. The symbols disappear. To activate the alarm press the ON/OFF Buttons again.
Setting the Temperature Display
- Press the °C/°F button to switch between degrees centigrade and degrees Fahrenheit.
Setting the Mold Alarm
Press and hold
°C/°F
| MOLD ALERT Appears in the Display and the Humidity Display flashes
---|---
Press or| Set a value for the upper Mold Threshold (can be set from 60
to 75 %)
Press °C/°F for 3 Sec and wait for 10 Sec| Display returns to normal Mode
- As soon as the humidity rises over the value set by you the symbols MOLD ALERT appear in the display and the red LED alarm signal flashes.
- To end the alarm press any button.
- The symbols MOLD ALERT remain on the display until the detected humidity drops under the set values.
- The factory setting for the mold alert value is 65%.
Read and reset MIN-/MAX Values
- To read the MIN and MAX values of temperature respectively relative humidity, briefly press the MAX/MIN Button.
- Hold the MAX/MIN button to reset the respective values and start a new recording.
Graphic Display of the Humidity
- In the graphic display mode, you can very easily read the recorded relative humidity and perceived level in the room within the last 12 hours.
The Influence of Humidity on Health
- Excessive humidity indoors furthers the growth of undesired organisms. Humidity between 30 % an 50 % indoors prevents the growth of fungi, mold, and mites.
- Residence in rooms with mold infestations can damage the human immune system and further allergies and infections of the respiratory system.
- Excessively dry air indoors can dry out the skin, irritate the sinuses and throat and contribute to infections.
- In very dry rooms relative humidity can be increased with a humidifier.
- Active heating and ventilation contribute to a comfortable interior climate.
Dew Point Temperature
- Briefly press the SET button (2) to have the dew point temperature displayed.
- Press the SET button (2) again to have the room temperature displayed again.
- The dew point temperature (also known as dew point) is the temperature that must fall below, given constant pressure, to make water vapor fall out as fog or dew. At the dew point the relative humidity is 100 % and the air is loaded with water vapor. The more water vapor the air contains the higher is thedew point. Therefore the dew point can be used to determine the absolute humidity.
- Usual indoor air commonly perceived as comfortable of 22° Cand 40 % humidity has a dew point of approx. 8° C.
- The dew point temperature range of the hygrometer ranges from 0° C to 50° C.
- If the dew point temperature is over 50° C “HH.H” will be displayed, if the temperature is under 0° C “LL.L” will be displayed.
Cleaning and Storing
- Wipe the unit with a dry or lightly moistened cloth. Do not clean the housing of the weather station with abrasives or aggressive chemicals in order not to damage the surfaces.
- While cleaning, do not strongly press on the LC display.
- Store the weather station indoors in a dry place that is protected from dust, dirt and extreme temperatures.
- Store the unit out of reach of children and persons in need of supervision.
- Remove the batteries from the unit if you do not intend to use it for a longer period of time.
Technical Data
Batteries | 2x LR03 (AAA) |
---|---|
Temperatur Measuring Range | 0° – +50° C |
Temperature Resolution | 0,1° C |
Deviation | +/- 1° C |
Dew Point Measuring Range | 0° – +50° C |
Relative Humidity | 20 – 95 % |
Relative Humidity Resolution | 1 % |
Deviation Humidity | +/- 5 % |
Dimensions | 120 x 86 x 21 mm |
Weight (without Batteries) | 102 g |
Features of the Article
Indoor Temperature Display | in °C resp. °F |
---|---|
Dew Point Temperature Display | in °C resp. °F |
Indoor Relative Humidity Display | in % |
Selectable Temperature Display | in °C resp. °F |
MAX-/MIN Display of Temperature and Relative Humidity | Yes |
Graphic Display of Relative Humidity | for the last 12 h |
Mold Alarm with Warning Symbol and flashing LED Alarm Signal
Selectable Threshold Values
| Illumination Duration 1 Minute
60 %, 65 %, 70 %, 75 %
Humidity Alarm with Warning Symbol and flashing LED Alarm for upper and lower relative Humidity
Selectable Threshold Values
| Illumination Duration 1 Minute
30 – 95 % in 5 % Steps
Easy to read, coloured Comfort Index| Yes
Operation via Sensor Buttons| Yes
Large LC-Display| 67 x 62 mm
EC Declaration of Conformity
declare by our own responsibility that the product
- Hygrometer/Thermometer with Mold Alert
- Artikel Nr. 94 53 07
- Article No. 94 53 07
is according to the basic requirements, which are defined in the European Directives and their amendments.
- 2011/65/EU
- Restriction of the Use of certain hazardous Substances in electrical and electronic Equipment (RoHS)
- 2014/30/EU
- EN IEC 55014-1:2021, EN IEC 55014-2:2021
The technical documentation are on file at the QA department of the Westfalia Werkzeug company
Customer Services
- Deutschland
- Westfalia
- Werkzeugstraße 1
- D-58093 Hagen
- Telefon: (0180) 5 30 31 32
- Telefax: (0180) 5 30 31 30 Internet: www.westfalia.de.
Österreich
- Westfalia
- Moosham 31
- A-4943 Geinberg OÖ
- Telefon: (07723) 4 27 59 54
- Telefax: (07723) 4 27 59 23
- Internet: www.westfalia-versand.at.
Schweiz
- Westfalia
- Wydenhof 3a
- CH-3422 Kirchberg (BE)
- Telefon: (034) 4 13 80 00
- Telefax: (034) 4 13 80 01
- Internet: www.westfalia-versand.ch.
Disposal
Dear Customer,
- Please help avoid waste materials.
- If you at some point intend to dispose of this article, then please keep in mind that many of its components consist of valuable materials, which can be recycled.
- Please do not discharge it in the rubbish bin, but check with your local council for recycling facilities in your area.
- © Westfalia 04/23
References
- Westfalia Versand Österreich | Werkzeug ✓ Garten ✓ Technik ✓ & mehr
- Westfalia Versand Schweiz | Werkzeug ✓ Garten ✓ Technik ✓ & mehr
- Westfalia Versand Deutschland | Werkzeug ✓ Garten ✓ Technik ✓ & mehr
Read User Manual Online (PDF format)