Installation, Operation and Owner’s ManualEuropean Home EH MAN GS VF
072823 E Gas Stones with Fusion Basket 

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilating air must be provided. Refer to page 6.
This heater may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes. This heater is only for use with the type of gas indicated on the rating plate. This heater is not convertible for use with other gases.

INSTALLER:

Leave this manual with the heater. END USER: Retain this manual for future reference.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket -
IconReport Number 284-L-04-5
July 2023
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

IMPORTANT SAFETY INFORMATION

Read these instructions carefully before installing or trying to operate this Vent Free gas heater.

  • Any change to this heater or its controls can be dangerous.
  • Improper installation or use of the heater can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
  • Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.
  • Do not use a blower insert, heat exchanger insert or other accessory, not approved for use with this heater where applicable.

WARNING

  1. Due to high temperatures, the heater should be located out of traffic and away from furniture and draperies.
  2.  Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
  3.  Young children should be carefully supervised when they are in the same room with the heater.
  4. Do not place clothing or other flammable material on or near the heater.
  5. Any safety screen or guard removed for servicing a heater, must be replaced prior to operating the heater.
  6. Installation and repair should be done by a qualified service person.
  7. To prevent malfunction and/or sooting, an unvented gas heater should be cleaned before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways be kept clean.
  8. CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have the heater serviced as it may not be operating properly.
  9. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.l/NFPA54.
  10. This unit complies with ANSI Z21.11.2-2007 Unvented Heaters.
  11. Do not install the heater in a bathroom or bedroom.
  12. Correct installation of the ceramic stones, proper location of the heater, and annual cleaning are necessary to avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the fireplace. See stone placement instructions for proper installation.
  13. WARNING: Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into fireplace. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur.
  14. Caution: Candles, incense, oil lamps, etc. produce combustion by-products including soot. Vent Free heaters will not filter or clean soot produced by these types of products. In addition, the smoke and/or aromatics (scents) may be reburned in the Vent Free heater which can produce odors. It is recommended to minimize the use of candles, incense, etc. while the Vent Free heater is in operation.
  15. Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
  16. Unvented gas heaters are a supplemental zone heater. They are not intended to be the primary heating appliance.
  17. Unvented gas heaters emit moisture into the living area. In most homes of average construction, this does not pose a problem. In houses of extremely tight construction, additional mechanical ventilation is recommended.
  18. During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the heater; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence. The initial break-in operation should last two to three hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in period will be slight and will disappear with continued use.
  19. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level. Refer to the National Fuel Gas Code.
  20. The heater and its main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
  21. The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 kPa).
  22. Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
  23. This heater must not be used with glass doors in the closed position. This can lead to pilot outages and severe sooting outside the fireplace.
  24. Never burn solid fuels in a fireplace where an unvented room heater is installed.
  25. Always have a fireplace screen in place when the appliance is in operation and, unless other provisions for combustion air are provided, the screen must have an opening(s) for induction of combustion air.
  26. All outside air ducts and/or ash dumps in the fireplace must be permanently closed prior to the installation of the heater.
  27. This appliance is for indoor use only.
  28. This appliance has been certified by OMNI-Test Laboratories, Inc. to ANSI Z21.11.2-2007, “Standard for Gas-Fired Room Heaters, Volume II, Unvented Room Heaters.” 29. This appliance is approved for installation in the Commonwealth of Massachusetts. The Board of State Examiners of Plumbers and Gas Fitters has issued approval number G3-1117155 for this appliance.

WARNING
This appliance is for installation in a solid-fuel burning fireplace or UL 127 factory-built fireplace or in a listed ventless firebox enclosure.
Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating that it has not been tested or should not be used with unvented gas logs.

GENERAL INSTALLATION INFORMATION

CODES
Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from…
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018 or
National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269
ADEQUATE COMBUSTION AND VENTILATION AIR
This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.
The National Fuel Gas Code, (ANSI Z223.1/NFPA 54), defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8 m 3
per kw) of the aggregate input rating of all appliances installed in that space. An unconfined space is defined as a space whose volume is not less than 50 cubic feet per 1,000 BTU per hour (4.8 m 3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.
UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION WHERE…
a) walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm (6 x 1011 kg per pa-sec-m 2 ) or less with openings gasketed or sealed;
b) weather stripping has been added on operable windows and doors, and
c) caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
This appliance is equipped for natural gas. Field conversion is not permitted.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket -
Maximum

The following formula can be used to determine the maximum heater rating (per the definition of unconfined space) that is allowed in your space:

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - Maximum
1

Example A: Consider two connecting rooms with an open area between, with the following dimensions: L1 = 151/2 ft., L2 = 12 ft., W = 12 ft., H = 8 ft.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - Maximum
2

Example B: If there were a door between the two rooms the calculation would be based only on the room with the heater.
Will my space support a Gas Stones Vent Free with Fusion Basket?
Maximum BTU/hr. my space will support (use formula above) 1)


BTU/hr. of European Home Gas Stones Vent Free 2) 39,000____
If the answer to 1) is greater than 2) then your space will support the installation of the Gas Stones Vent Free; if 1) is less than 2) then your space will not support a Gas Stones Vent Free.
WARNING
If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Section 5.3 or applicable local codes.
Vision Vent Free Gas Burner Module
S/N NG-E
This appliance is equipped for Natural Gas.
Input Rating Btu/hr 39,000
Min. Input (Btu/hr) 27,000
Orifice (OMS) 6 Port #55
Manifold Press. 3.5″/0.87kPa
Min. Supply Press. 4.0″/1.0kPa
Max. Supply Press. 7.0″/1.7kPa
Type of Control Maxitrol GV60 Gas Control
us OMNlTeat Laboratories, Inc. Report #284-F-03-5 & 284-L-04-5 Manufactured by European Home Div. of Europa Ja, Inc. Middleton, MA 781-324-8383
This burner module is certified by OMNI-Test Laboratories to ANSI 221.11.2-2007 Unvented Heaters, when installed in the Vision Vent Free Gas Fireplace or the Gas Stones Vent Free With Fusion Basket.
Removal of this marking will void compliance of this heater with ANSI 221.11.2.
This appliance must be installed in accordance with local codes, if any; ff none, follow the ANSI Z223.1.
Installation and service must be performed by a qualHied installer, service agency or the gas supplier.
This appliance shall not be field converted. WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL 127 factory­ built fireplace or in a listed ventless firebox enclosure. It has been design certHied for these installations.
Exception: DO NOT install this appliance in a factory-built fireplace that includes instruction stating it has not been tested or should not be used with unvented gas logs.
WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.
WARNING: Fireplace screens must be closed while the  applianCI; is in opertion. Any glass d?ors must be completely
open while the appliance Is in operation.
This heater shall not be installed in a bedroom or bathroom.
This appliance is intended for supplemental heating.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
See instructions manual for further information.
Apply loose material per instructions manual. DO NOT apply extra material or material not supplied with the heater. Replace only with European Home Stone Kit Part Number VPK-01.
This appliance may be installed in an aflermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Refer to the owner’s information manual provided with this appliance. Installation and service must be perfonned by a qualified installer, service agency, or the gas supplier.
CAUTION
Hot while in operation. Do not touch.
• Severe burns may result. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.
WARNING ■ When used without adequate
• combustion and ventilation air, heater may give off excessive CARBON MONOXIDE, an odorless, poisonous gas.
DO NOT INSTALL HEATER UNTIL ALL NECESSARY PROVISIONS ARE MADE FOR COMBUSTION AND VENTILATION AIR. CONSULT THE WRITTEN INSTRUCTIONS PROVIDED WITH THE HEATER FOR INFORMATION CONCERNING COMBUSTION AND VENTILATION AIR. IN THE ABSENCE OF INSTRUCTIONS, REFER TO THE NATIONAL FUEL GAS CODE, ANSI Z223.1, OR APPLICABLE LOCAL CODES. This heater is equipped with a PILOT LIGHT SAFETY SYSTEM designed to turn off the heater if not enough fresh air is available. I DO NOT TAMPER WITH THE PILOT LIGHT SAFETY SYSTEM! I If heater shuts off, do not relight until you provide fresh air.
If heater keeps shutting off, have it serviced. Keep burner and control compartment clean.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH.
Early signs of carbon monoxide poisoning resemble the flu, with headache, dizziness and/or nausea. If you have these signs, heater may not be working properly. Get fresh air at once! Have heater serviced.
Listing Label for Gas Stones Vent Free Natural Gas Burner

SPECIFICATIONS and DIMENSIONS

Fuel Type: Natural Gas ONLY
Manifold Pressure: 3.5” (0.87 kPa)
Minimum Supply Pressure: 4.0” (1.0 kPa)
Maximum Supply Pressure: 7.0” (1.7 kPa)
Orifice Size: 6 Port #55 DMS
Input: High Fire – 39,000 BTU/hr.

Low Fire – 27,000 BTU/hr.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket -
DIMENSIONS

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket -
DIMENSIONS 1

MODEL A B C D
GAS STONES 24 “ 24″
[610] 12″
[305] 17″
[432] 6 13/46″

[170]
GAS STONES 30 “| 30″
[762]| 12″
[305]| 17″
[432]| 613/46″
[170]

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket -
DIMENSIONS 2

Premise gas supply should terminate within shaded area, shown on plan view, above.

FIREPLACE REQUIREMENTS

Your Gas Stones Vent Free with Fusion Basket is for installation in a solid- fuel burning fireplace or UL 127 factory-built fireplace or in a listed ventless firebox enclosure.
Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating that it has not been tested or should not be used with unvented gas logs.
When installed in a vented fireplace your Gas Stones Vent Free with Fusion Basket must sit fully inside the fireplace so that it properly drafts up the chimney flue.
In all cases, be certain that the burner of your Gas Stones Vent Free with Fusion Basket is behind the fireplace lintel. See below.
WARNING
Before installing in a solid-fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket -
DIMENSIONS 3 Note: If the fireplace has doors, they must be opened fully during operation of the appliance.
MANTEL CLEARANCES

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - MANTEL
CLEARANCES Combustible mantels may be no closer to the fireplace opening than the distances shown above.

INSTALLING THE BURNER

Place four AA batteries in the battery case and connect the battery case to the receiver as shown below. Ensure that the wiring is connected as shown at right.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket -
BURNER

GAS SUPPLY

The gas supply should terminate within three inches (3”) of the rear of the burner module. In this way the gas supply can be hidden under the Fusion Basket. Place the burner module in the center of the fireplace and connect the gas supply to the flexible gas supply connector provided with the burner. The gas supply line must terminate with a male 1/2” NPT pipe thread in the rear of the fireplace. The gas supply piping should have a separate gas shutoff valve and a 1/8” NPT plugged tapping up stream of the valve.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - GAS
SUPPLY

The Gas Stones Vent Free with Fusion
Basket and its main control valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The Gas Stones Vent Free with Fusion Basket must be isolated from the gas supply piping system by closing the main control valve during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psi (3.5 kPa). After the gas supply has been connected, open the main supply and apply a soapy water solution to all the fittings to check for gas leaks. Never use a flame to test for leaks. Ensure that the burner inlet tube is in the shutter box.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - GAS
SUPPLY 1

Place the Fusion Basket over the burner so the burner is centered in the opening in the Fusion Basket as shown. Slide the Battery Case beneath the Fusion Basket
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

STONE CONFIGURATION

The Gas Stones Vent Free with Fusion Basket can be operated with, or without, the decorative stones and/or the embers. The following is the recommended stone/ember configuration. Slight differences in the placements are acceptable.
When using the stones and embers, begin by placing one layer of the embers evenly over the entire burner top as shown.
Note: Do not overcrowd the pilot.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - GAS
SUPPLY 2

Sort your stones, by size, into sixteen small, three medium and four large. Place a row of six small stones along the rear edge of the burner as shown.European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket -
GAS SUPPLY 3

Next, place two large stones and three small stones on the burner. Then place two medium and four small stones along the front edge of the burner.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - GAS
SUPPLY 4

Finally, place the remaining two large, one medium and three small stones on top as shown below.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - GAS
SUPPLY 5

A completed installation of stones is shown below.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - GAS
SUPPLY 6

The stones installation must be per these instructions. This heater must use only the stones provided by European Home. An excess amount of stones may adversely affect the performance of the heater. All previously applied loose material must be removed prior to reapplication.

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING!
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This heater is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electric switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s  instructions
  • If you cannot reach your gas supplier, call the fire department.
    C. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

RESETTING THE SYSTEM (Synchronizing the Remote and Receiver)
Before the first fire the remote control and receiver must be synchronized. This is accomplished by resetting the system as follows:

  1. press and hold the receiver RESET button until you hear the second of two beeps then
  2. release the RESET button and, within twenty seconds,
  3. press the SMALL FLAME button on the remote until you hear a confirming beep. Release the down button.
    The receiver and remote are now each synchronized and ready for normal operation.

LIGHTING THE FIREEuropean Home EH MAN GS VF 072823 E Gas Stones with
Fusion Basket - FIRE

  1. STOP! Read the safety information above.
  2. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
  3. Push the OFF button on the remote control to insure the appliance is off.
  4. Wait five (5) minutes to clear out any gas. Then smell for gas including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas, go to the next step.
  5. Press the OFF and LARGE FLAME buttons simultaneously. Release the buttons once you hear a beeping noise. This acoustic signal tells you that the start sequence has begun. Further short signals will continue until main gas flows and the burner is lit. If the pilot or burner does not light, go back to Step 3, above.
  6. Use the LARGE FLAME and SMALL FLAME buttons to adjust the flame height.
  7. After powering off the fireplace, it can take about 45 seconds before you are able to light it again.

MAINTENANCE

A qualified service agency should conduct an annual inspection and maintenance of your Gas Stones Vent Free with Fusion Basket, the fireplace, chimney, and the installation to keep it running safely. The following procedures should be performed only by a qualified service person. The gas supply should be turned off whenever a maintenance procedure is performed. All parts of the fireplace that are removed for servicing must be replaced prior to operation.
Cleaning the Stones and Burner.
With all parts of the fireplace at room temperature, carefully remove and clean the stones with a soft bristled brush. Never use a vacuum cleaner to clean the stones. Clean the burner surface with a brush. Replace the components per the instructions in the INSTALLING THE BURNER section.
Failure to keep the primary air opening of the burner clean may result in sooting and property damage.
Inspecting the Chimney
An inspection of the chimney should be made as part of the annual service appointment. The chimney must have no blockage and be in good repair.
Replacing the Batteries
With all parts of the fireplace at room temperature, slide the Battery Case from beneath the Fusion Basket. Replace the old batteries with four, new, high quality AA alkaline batteries.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - FIRE
1

TROUBLESHOOTING

OBSERVED PROBLEM: POSSIBLE CAUSE: REMEDY:
A. No transmission (motor does not turn) 1. Receiver must learn new code.

2. Dead batteries.
3. The receiver is surrounded by metal, reducing the transmission range.
4. Receiver
5. Remote control
6. Wiring at valve damaged.
7. Bent pins on 8 wire connector.| 1. Reset system.
2. Replace batteries.
3. Change the position of the antenna.
4. Replace receiver and reprogram code as above.
5. Replace the remote control and reprogram code as above.
6. Replace valve.
7. Straighten pins on 8 wire connector.
B. No ignition; no tone| 1. Dead batteries.
2. Receiver| 1. Replace batteries.
2. Replace the remote control and reprogram code as above.
C. No ignition; one 5 second continuous tone (7 short beeps might be  heard prior to the 5 second tone)| 1. Loose wire.
2. Receiver
3. Bent pins on 8 wire connector.
4. Valve| 1. Secure wire.
2. Replace receiver and reprogram code as above.
3. Straighten pins on 8 wire connector.
4. Replace valve.
D. No ignition; no spark at pilot| 1. Verify spark at receiver
2. Faulty ignitor rod or     ignition wire| 1. Replace receiver if no spark
2. Replace pilot assembly
E. No pilot flame and control continues to spark| 1. Air in the pilot supply line.
2. No spark at pilot burner.| 1. Purge the line or start ignition several times.
2. Check spark gap; check wiring connection. Check
for spark in location along  cable.
E. No pilot flame and control continues to spark| 3. Valve
4. Over tightened thermocouple.
5. Receiver| 3. Replace valve. Do not over  tighten the thermocouple.
4. Replace valve and thermocouple interrupter.
5. Replace receiver and reprogram code as above.
F. Pilot is lit and control continues to spark. Valve shuts off after 10-30 seconds. Valve operates manually.| 1. Receiver| 1. Replace receiver and reprogram code as above.
G. Pilot is lit and sparking stops.
Valve shuts off after 10-60 seconds.
Valve does not operate manually.| 1. Not enough voltage generated from the thermocouple or too much resistance in the circuit.
2. Thermocouple
3. Low inlet pressure.
4. Valve| 1. Use a digital multimeter set in the mV range and measure the voltage between the spade connector closest to the thermocouple (-) and thermocouple tube (+) itself. The reading should be 21-30 mV.
2. Replace thermocouple.
3. Confirm regulator pressure and sizing. Replace if necessary.
4. Replace valve. Do not overtighten the thermocouple.
H. Three short beeps while the motor turns.| 1. Batteries are low.| 1. Replace batteries.
I.  Pilot flame lights but there is no main gas flow.| 1. Manual override knob is in MAN position.
2. Valve turned down to pilot flow.
3. Low inlet pressure.
4. Valve.| 1. Turn manual override knob to ON position.
2. Turn flame to high fire by pressing up button on remote control.
3. Confirm regulator pressure, and sizing. Replace valve if necessary.
4. Replace valve.

European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket - FIRE
2

Make a periodic visual inspection of the pilot and main burner flames. The flames should look similar to those in the picture above.

PARTS LIST

Burner Module, Vent Free, NG
Stone
Kit
Pilot  Assembly
Fusion Basket, 24”
Fusion Basket, 30”| V-VFBM-NG-01
GS-BS
Repl-V-VF-GS-PA-01
FB-BLK-24 or
FB-WHT-24
FB-BLK-30 or
FB-WHT-30
---|---

For replacement parts and customer service:
Contact your local Dealer
European Home Warranty
Vision and Gas Stones Family of Products
European Home warrants the Vision, Vision Vent Free, Gas Stones and Gas Stones Vent Free burners against defects in materials and workmanship for a period of TWO (2) YEARS from the date of original retail purchase. We warrant the Vision cabinet, Vision Vent Free cabinet, Fusion Basket and Beach Stones against defects in materials and workmanship for a period of FIVE (5) YEARS from the date of original retail purchase. If a defect exists, European Home will, at its option, either (1) repair the product at no charge, using new or refurbished replacement parts or (2) exchange the product with one which is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product. A replacement product/part assumes the remaining warranty of the original product or ninety (90) days from the date of replacement or repair, whichever provides longer coverage for you. When a product or part is exchanged, any replacement item becomes your property and the replaced item becomes the property of European Home. Nothing in the above shall be deemed to imply that this warranty shall apply to work which has been abused or neglected or shows evidence of changes or modifications by others with or without permit, damages caused by the acts of God, building settlement or moving, fire or vandalism. In addition, installation of this product that varies from the requirements stated in the instruction manual will void the warranty.

PRODUCT INSTALLATION RECORD

Installer: Please complete this form.
Customer: Please retain this information.

Purchased From|
---|---
Date of Purchase|
Installed By|
Date of Installation|
Fireplace Serial Number|
Fuel Type|

Appendix A

PROGRAMMING THE REMOTE CONTROL
Note: The system shuts off the appliance completely if there is no change in the flame height for 5 days.
Setting °C/24 Hour or °F/12 Hour Clock.
Press OFF and SMALL FLAME to toggle between °F/12 hr and °C/24 hr clock.
Setting the time.
Simultaneously press the SMALL FLAME and LARGE FLAME buttons, the display now flashes.
Press LARGE FLAME to set the hour and SMALL FLAME to set the minute.
Press OFF to return to manual mode.
Igniting the Appliance.
On the remote control, simultaneously press and hold the OFF and LARGE FLAME buttons.
An acoustic signal indicates that the start sequence has begun.
The electronic system then checks that the main gas is flowing and ignites the main burner; this may take up to 20 seconds.
NOTE: During start-up, the MANUAL knob on the gas valve cannot be in the MAN position.
Changing the Mode of Operation.
Briefly pressing the SET button changes the mode of operation in the following order:
Man – Temp – Temp – Timer – back to Man
Man – Manual Flame Height Adjustment.
You are now able to use the remote control. To increase the flame, the LARGE FLAME button should be depressed. Pressing the SMALL FLAME button on the handset will reduce the flame. The main flame may be lowered all the way down until it is off, leaving only the pilot ignited.
Fully Extinguishing the Appliance
From any heat setting, press the OFF button for a few seconds. This will cause the burner to fully extinguish.
The system has a safety interlock which will not allow the ignition until the interlock rests. This may take a few minutes.
The appliance should be shut off completely using the OFF button on the handset and not left on pilot only, except for temporary use. This resets the system and all safety features.
Temp – Daytime Temperature mode.
The appliance must be in standby mode; pilot ignited. The room temperature is measured and compared to the set temperature. The flame height is then automatically adjusted to reach the daytime set temperature.
Temp – Nighttime setback Temperature mode.
The appliance must be in standby mode; pilot ignited. The room temperature is measured and compared to the nighttime setback temperature. The flame height is then automatically adjusted to achieve the nighttime setback temperature.
Timer mode.
The appliance must be in standby mode; pilot ignited. The Timer setting allows you to set 2 burner Temp times and 2 burner Temp times every 24 hrs.
For Temp to operate as a thermostat, TEMP must be set at 4°C or higher.
If the Temp setting is decreased to – -, the motor will turn the valve to the standby position in the moon times and await the next burner Temp cycle.
Setting the Temperature.
Select either the Temp MODE or the Temp MODE by briefly pressing the SET button.
Hold the SET button until the TEMP display flashes.
Set the desired temperature with SMALL FLAME or LARGE FLAME.
Press OFF to complete the program.
Setting the Timer.
Select Timer mode by briefly pressing the SET button.
Press and hold the SET button until the P1 is displayed, and the time flashes. Set the hour by pressing LARGE FLAME and set the minutes by pressing SMALL FLAME.
Briefly press SET button for the next burner cycle time.
Once all 4 times are set, press OFF to complete the programming.

European Home Logo EUROPEAN HOME
a division of Europa Ja, Inc.
30 Log Bridge Road
Building 300 – Suite 303
Middleton, MA 01949
www.europeanhome.com
European Home EH MAN GS VF 072823 E Gas Stones with Fusion Basket  - Bar
Code Gas Stones Vent-Free Rev#07282023
IMGSVF04-181011
EuropeanHome.com

Documents / Resources

| European Home EH-MAN-GS-VF-072823-E Gas Stones with Fusion Basket [pdf] Owner's Manual
EH-MAN-GS-VF-072823-E Gas Stones with Fusion Basket, EH-MAN-GS-VF-072823-E, Gas Stones with Fusion Basket, with Fusion Basket, Fusion Basket, Basket
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals