European Home EH-MAN-GS-NV-072823-E Gas Stones with Fusion Basket Owner’s Manual

June 13, 2024
European Home

EH-MAN-GS-NV-072823-E Gas Stones with Fusion Basket

Product Information

The Gas Stones with Fusion Basket is a decorative gas appliance
designed for installation in a solid-fuel burning fireplace. It is
equipped for use with natural gas or propane and cannot be
converted to other fuel types. The appliance must be installed by a
qualified installer, service agency, or gas supplier. It is
certified by OMNI-Test Laboratories to meet safety standards.

Specifications and Dimensions

The appliance has the following specifications:

  • Input Rating Btu/hr:

    • Natural Gas: 42,000 Btu/hr (minimum input: 27,000 Btu/hr)
    • Propane: 43,500 Btu/hr (minimum input: 27,000 Btu/hr)
  • Orifice: Port #55 for natural gas, #48 for propane

  • Manifold Pressure: 4.0/1.0kPa for natural gas, 10/2.5kPa for
    propane

  • Minimum Supply Pressure: 4.0/1.0kPa for natural gas, 11/2.7kPa
    for propane

  • Maximum Supply Pressure: 7.0/1.7kPa for natural gas, 13/3.2kPa
    for propane

Product Usage Instructions

  1. Ensure that the fireplace where the Gas Stones with Fusion
    Basket will be installed is constructed of noncombustible material
    and has a working flue.

  2. Install a fireplace screen that allows for the flow of
    combustion air and keep it in place when the appliance is
    operating.

  3. Check local codes or refer to the National Fuel Gas Code (ANSI
    Z223.1) or the Canadian Installation Code (CAN/CGA B149.1) for the
    installation and provision of combustion and ventilation air.

  4. Keep the appliance area clear and free from combustible
    materials, gasoline, and other flammable vapors and liquids.

  5. Do not use the appliance if any part has been under water. Call
    a qualified service technician for inspection and replacement of
    any underwater components.

  6. Do not burn solid fuels in the fireplace where the decorative
    appliance is installed.

  7. Follow the provided instructions for connecting the appliance
    to the natural gas or propane supply.

  8. Configure the gas stones in the Fusion Basket according to the
    instructions provided.

  9. Refer to the operating instructions for information on how to
    safely operate the Gas Stones with Fusion Basket.

  10. Perform regular maintenance as outlined in the manual to ensure
    safe and efficient operation.

  11. If you encounter any issues, refer to the troubleshooting
    section of the manual for assistance.

Please refer to the complete user manual for detailed
information on maintenance, parts list, warranty, and other
important details.

GAS STONES WITH FUSION BASKET
NATURAL VENT Installation, Operation and Owner’s Manual

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Product Information Page

WHAT TO DO IF YOU SMELL GAS · Do not try to light any appliance.
· Do not touch any electrical switch; do not use any phone in your building.
· Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
· If you cannot reach your gas supplier, call the fire department.

Report #284-L-02c-5

July 2023

TABLE OF CONTENTS

Important Safety Information

4

Specifications and Dimensions

7

Before You Begin

10

Fireplace Requirements

11

Installing the Burner

13

Gas Supply

13

Stone Configuration

15

Operating Instructions

18

Maintenance

21

Troubleshooting

22

Parts List

24

Warranty

25

Gas Stones Vented Rev#07282023 3

EuropeanHome.com

IMPORTANT SAFETY INFORMATION
1. This appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.
2. A fireplace screen must in place when the appliance is operating and must provide for the flow of combustion air.
3. The installation and the provision for combustion and ventilation air must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 or the Canadian Installation Code, CAN/CGA B149.1.
4. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).
5. The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply system at test pressures equal to or less than ½ psi (3.5 kPa).
6. The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.
7. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
8. Solid fuels shall not be burned in a fireplace where a decorative appliance is installed. 9. This appliance is equipped for use with natural gas or propane and cannot be converted to the
other fuel. 10. This appliance has been certified by OMNI-Test Laboratories, Inc. to ANSI Z21.60a-2003· CSA
2.26a-2003 Decorative Appliances for Installation in Solid-Fuel Burning Fireplaces and CAN12.17-M91,Gas-Fired Appliances for Use At High Altitudes. 11. This appliance is approved for installation in the Commonwealth of Massachusetts. The Board of State Examiners of Plumbers and Gas Fitters has issued approval number G3-1209-252 for this appliance. 12. This appliance is approved for installation in New York City. The Department of Buildings has issued MEA number 25-06-E for this appliance.

Gas Stones Vented Rev#07282023 4

EuropeanHome.com

AVERTISSEMENT: Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
· Ne pas tenter d’allumer d’appareil. · Ne touchez à aucan interrupteur. Ne pas vous servir des téléphones se trouvant dans le
bâtiment où vous trouvez. · Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivezles instructions
du fournisseur. · Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incindie.
L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
AVERTISSEMENT: Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilsées.
Les dêgagements sont conformes aux codes d’installation locaux et aux exigences du fournisseur de gaz.
NE PAS UTILISER AVEC DES PORTES EN VERRE.
Ne pas se servir de cet appareil s’il a été plongé,dans l’eau, même partiellement. Faire inspecter l’appareil par un technicien qualifié et remplacer toute partie du système de commande et toute commande qui ont été plongée dans l’eau.

Gas Stones Vented Rev#07282023 5

EuropeanHome.com

Vision Gas Burner Module, Model VBM-NG-02

S/N

Vision Gas Burner Module, Model VBM-LP-02

This appliance is equipped for:
Input Rating Btu/hr Min. Input (Btu/hr) Orifice (DMS) Manifold Press. Min. Supply Press. Max. Supply Press.

Natural Gas/Gaz Naturel
42,000 27,000 6 Port #55 4.0″/1.0kPa 4.0″/1.0kPa 7.0″/1.7kPa

Propane
43,500 27,000

48 10″/2.5kPa 11″/2.7kPa 13″/3.2kPa

Cet appareil est équipé pour:
Debit Calorifique Puissance Minimum L’injecteur Press. a la Tubulure Press. D’Arrivée Min. Press. D’Arrivée Max.

These burner modules are certified by OMNI-Test Laboratories to “CSA/ANSI Z21.50-2019 / CSA 2.22-2019 Vented decorative gas appliances and CSA 2.17-2017 Gas-fired appliances for use at high altitudes” when installed in the Vision Gas Fireplace (Report #00284GL002S) and “ANSI Z21.60-2017 / CSA 2.26-2017 – Decorative gas appliances for installation in solid-fuel burning fireplaces” when installed in the Gas Stones with Fusion Basket (Report #00284GL002S).
Ces modules de brûleur sont certifiés par les laboratoires OMNI-Test (OMNI- Test Laboratories) conformes aux normes “CSA/ ANSI Z21.50-2019 / CSA 2.22-2019 pour les foyers à gaz ventilés” lorsqu’ils sont installés dans le foyer à gaz Vision (Rapport #00284GL002S) et conformes aux normes “ANSI Z21.60-2017 / CSA 2.26-2017 pour les appareil à gaz décoratifs pour une installation dans les foyers alimentés au combustible solide” lorsqu’ils sont installés dans le foyer Gas Stones with Fusion Basket (Rapport #00284GL002S).
This appliance equipped only for altitudes 0-2000 feet (0-610m) in the USA and 0-4500 feet (0-1370m) in Canada without change. Cet appareil n’est équipé que pour les altitudes de 0 à 610 m (0 à 2000 pi) aux États-Unis et 0 à 1370 m (0 à 4500 pi) au Canada sans modification.
This appliance must be installed in accordance with local codes, if any; if none, follow the ANSI Z223.1, or CSA-B149.1. Installer l’appareil selon les codes ou réglements locaux; ou, en l’absence de tels réglements, selon les codes d’installation ANSI Z223.1 ou CSA-B149.1 en vigueur.

Vision Gas Fireplace Report #00284GL002S
Gas Stones with Fusion Basket Report #00284GL002S
Manufactured by European Home div. of Europa Ja, Inc Middleton, MA 01949
781-324-8383

CAUTION: Hot while in operation. Do not touch. Severe burns
may result. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.
ATTENTION: L’appareil est chaud lorsqu’il founctionne. Ne
pas toucher l’appareil. Risque de brûlures graves surveiller les enfants. Garder les vêtements, les meubles, l’essence ou autres liquides produisant des vapeur inflammables loin de l’appareil.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

AVERTISSEMENT: Une installation, un réglage, une modification, une réparation ou un entretien mal effectué puet causer des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui accompagne l’appareil. Pour de l’aide ou des renseignements supplémentaires, consultez un installateur, un technicien agréé ou les fournisseur de gaz.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

S’assurer que le brûleur et le compartiment des commande sont propres. Voir les instructions d’installation et d’utilisation qui accompagnent

l’appareil.

IGN

Gas Stones with Fusion Basket Listing Label

Gas Stones Vented Rev#07282023 6

EuropeanHome.com

SPECIFICATIONS and DIMENSIONS

Manifold Pressure: Maximum Supply Pressure: Minimum Supply Pressure: Orifice Size: Canadian Efficiency P.4: High Fire Input: Low Fire Input:

Natural Gas 4.0″ (1.0 kPa) 7.0″ (1.7 kPa) 4.0″ (1.0 kPa) 6 Port #55 DMS 32% 42,000 BTU/hr. 27,000 BTU/hr.

Propane (LP) 10.0″ ( 2.5 kPa) 13.0″ (3.2 kPa) 11.0″ (2.7 kPa) #48 DMS 39% 43,500 BTU/hr. 27,000 BTU/hr.

Gas Stones with 24″ Fusion Basket

Gas Stones with 30″ Fusion Basket
Gas Stones Vented Rev#07282023 7

EuropeanHome.com

SPECIFICATIONS and DIMENSIONS

MODEL GAS STONES 24″ GAS STONES 30″

A 24″ [610] 30″ [762]

B 12″ [305] 12″ [305]

C 17″ [432] 17″ [432]

D 6 11/16″ [170] 6 11/16″ [170]

Gas Stones Vented Rev#07282023 8

EuropeanHome.com

SPECIFICATIONS and DIMENSIONS

0.75

0.75

22.50

3.00

Rear of Fireplace

Room Premise gas supply should terminate within shaded area, shown on plan view, above.

Gas Stones Vented Rev#07282023 9

EuropeanHome.com

BEFORE YOU BEGIN
Before starting the installation of your Gas Stones with Fusion Basket be sure to have the following tools and supplies: · Adjustable wrench · Phillips and straight-blade screwdrivers · Tape measure and framing square · Safety glasses and gloves · Manometer · Leak detection fluid (non-corrosive) or gas detector
NOTE!
Reset the Gas Stones with Fusion Basket before the first fire. See Resetting the System under OPERATING INSTRUCTIONS for details.

Gas Stones Vented Rev#07282023 10

EuropeanHome.com

FIREPLACE REQUIREMENTS

Your Gas Stones with Fusion Basket must sit fully inside your fireplace so that it properly drafts up the chimney flue.
Be certain that the burner of your Gas Stones with Fusion Basket is behind the fireplace lintel. See Figure 1.

Note: If the fireplace has doors, they must be opened fully during operation of the appliance.

Lintel

Figure 1

Clamp

Figure 2
Gas Stones Vented Rev#07282023

A minimum free opening of 50 square inches must be provided by the chimney or damper to vent the flue gases. The chimney damper must be fixed with the clamp provided to maintain the minimum free opening. See Figure 2.
Note: The Commonwealth of Massachusetts requires that the damper be removed or welded in the fully open position.
EuropeanHome.com 11

MANTEL CLEARANCES
12.0″ 5.0″
10.0″ 8.0″

Figure 2a

Existing fireplace opening

Top of existing fireplace opening

Combustible mantels may be no closer to the fireplace opening than the distances shown in the Figure 2a side view, above.

Gas Stones Vented Rev#07282023 12

EuropeanHome.com

INSTALLING THE BURNER
Place 4 AA batteries in the battery case and connect the battery case to the receiver as shown in Figure 3a.
Ensure that the wiring is connected as shown in Figure 3b.

RESET button

RESET button
Figure 3a

Red-tipped Wire (TC)

Yellow-tipped Wire (SW)
Figure 3b

GAS SUPPLY
Place the burner module in the center of the fireplace and connect the gas supply to the flexible gas supply connector provided with the burner. The gas supply line must terminate with a male ½” NPT pipe thread in the rear of the fireplace. The gas supply piping should have a separate gas shutoff valve and a 1/8″ NPT plugged tapping up stream of the valve. The Gas Stones with Fusion Basket and its main control valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa). The Gas Stones with Fusion Basket must be isolated from the gas supply piping system by closing the main control valve during any pressure testing of the gas supply system at test pressures equal to or less than ½ psi (3.5 kPa).

Warning: This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.

Figure 4

Gas Stones Vented Rev#07282023 13

EuropeanHome.com

After the gas supply has been connected, open the main supply and apply a soapy water solution to all the fittings to check for gas leaks. Never use a flame to test for leaks. If you are installing a propane burner, check that the air shutter (see Figure 5) is in the open position. Replace the burner in the burner module. Ensure that the burner inlet tube is in the shutter box.
Air shutter shown in the open position (for propane only)

Figure 5
Place the Fusion Basket over the burner so the burner is centered in the opening in the Fusion Basket as in Figure 6.

Figure 6
Gas Stones Vented Rev#07282023 14

EuropeanHome.com

STONE CONFIGURATION
The Gas Stones with Fusion Basket can be operated with, or without, the decorative stones and/or embers. The following is the recommended configuration. Slight differences in the placements are acceptable.
When using the stones and embers, begin by placing one layer of the embers evenly over the entire burner top as shown in Figure 7.
Note: Do not overcrowd the pilot.

Figure 7
Sort your stones, by size, into sixteen small, three medium and four large. Place a row of six small stones along the rear edge of the burner as shown in Figure 8.

S

S S

S

S

S

Gas Stones Vented Rev#07282023

Figure 8
15

EuropeanHome.com

S S

L

L

S

Figure 9

Next, place two large stones and three small stones on the burner as shown in Figure 9. Then place two medium and four small stones along the front edge of the burner as shown in Figure 10.

M S

S

S

M

S

Figure 10

Gas Stones Vented Rev#07282023 16

EuropeanHome.com

L

S

Figure 11

L M

Finally, place the remaining two large, one medium and three small stones on top as shown in Figure 11.

Gas Stones Vented Rev#07282023 17

EuropeanHome.com

OPERATING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING!
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS · Do not try to light any appliance. · Do not touch any electric switch; do not use any phone in your building. · Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions · If you cannot reach your gas supplier, call the fire department.
C. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
The Gas Stones with Fusion Basket has two safety features which affect the operation: 1) two-button child safety ignition 2) 45 second safety timer
The safety ignition requires that two buttons be depressed to begin the ignition sequence and the timer requires that 45 seconds elapse between start attempts.

Gas Stones Vented Rev#07282023 18

EuropeanHome.com

LIGHTING THE FIRE

1. STOP! Read the safety information above.

2. This appliance is equipped with an ignition device which

automatically lights the pilot. Do not try to light the pilot

by hand.

3. Push the OFF button on the remote control to insure the

appliance is off. 4. Wait five (5) minutes to clear out any gas. Then smell for

SET

gas including near the floor. If you smell gas, STOP! Follow

“B” in the safety information above. If you don’t smell gas,

go to the next step.

OFF

5. Press the OFF and LARGE FLAME (Ç) buttons

simultaneously. Release the buttons once you hear a

beeping noise. This acoustic signal tells you that the start

sequence has begun. Further short signals will continue

until main gas flows and the burner is lit. If the pilot or

burner does not light, go back to Step 3, above. 6. Use the LARGE FLAME (Ç) and SMALL FLAME (È)

buttons to adjust the flame height.

TO TURN OFF THE HEATER
7. Push the OFF button on the remote control to turn the appliance off. 8. After powering off the fireplace, it can take about 45 seconds before
you are able to light it again.

LARGE FLAME
SMALL FLAME

RESET BUTTON

RESETTING THE SYSTEM

This procedure resets the system as well as `pairs’ the remote and the receiver. It is only needed to be performed once but can be done as often as necessary. To reset the system:

1. press and hold the receiver reset button until you hear the second of two beeps then 2. release the reset button and, within twenty seconds, 3. press the SMALL FLAME button on the remote until you hear two confirming beeps

The receiver and remote are now each reset and ready for normal operation.
Gas Stones Vented Rev#07282023 19

EuropeanHome.com

Note: The system shuts off the appliance completely if there is no change in the flame height for 5 days.
Igniting the Appliance. Ensure the ON/OFF switch is in the ON position. On the remote control, simultaneously press and hold the OFF andÇbuttons. An acoustic signal indicates that the start sequence has begun. The electronic system then checks that the main gas is flowing and ignites the main burner; this may take up to 20 seconds. NOTE: During start-up, the MANUAL knob on the gas valve cannot be in the MAN position.
Manual Flame Height Adjustment. You are now able to use the remote control. To increase the flame, the LARGE FLAME (Ç)button should be depressed. Pressing the SMALL FLAME (È) button on the handset will reduce the flame. The main flame may be lowered all the way down until it is off, leaving only the pilot ignited.
Fully Extinguishing the Appliance From any heat setting, press the OFF button for a few seconds. This will cause the burner to fully extinguish. The system has a safety interlock which will not allow the ignition until the interlock rests. This may take a few minutes. The appliance should be shut off completely using the OFF button on the handset and not left on pilot only, except for temporary use. This resets the system and all safety features.
Automatic Turndown.
1. The valve will turn to pilot flame if there is no change in flame height for a six hour period.
Automatic Shut Off.
1. With low battery power in the receiver, the system shuts off the fire completely. This does not happen if the power supply is interrupted.
2. The system shuts off the fire completely if there is no change in flame height for 5 days.
3. The system shuts off the fire if the main burner does not completely ignite approximately 20 seconds after ignition or after pushing the LARGE FLAME (Ç) button.

Gas Stones Vented Rev#07282023 20

EuropeanHome.com

MAINTENANCE
A qualified service agency should conduct an annual inspection and maintenance of your Gas Stones with Fusion Basket, the fireplace, chimney, and the installation to keep it running safely. The following procedures should be performed only by a qualified service person. The gas supply should be turned off whenever a maintenance procedure is performed. All parts of the fireplace that are removed for servicing must be replaced prior to operation.
Cleaning the Stones and Burner. With all parts of the fireplace at room temperature, carefully remove and clean the stones with a soft bristled brush. Never use a vacuum cleaner to clean the stones. Clean the burner surface with a brush. Replace the components according to the instructions starting on page 11 of this manual.
Inspecting the Chimney An inspection of the chimney should be made as part of the annual service appointment. The chimney must have no blockage and be in good repair.
Replacing the Batteries With all parts of the fireplace at room temperature, remove the stones and embers. Remove the Fusion Basket from the fireplace. Find the battery compartment door on top of the receiver and slide it open. Remove the four batteries and, minding the correct polarity, replace them with fresh AA batteries. Close the battery compartment cover and re-set the Fusion Basket, embers and stones according to the previous instructions.

RESET
Battery Compartment RESET button
Gas Stones Vented Rev#07282023 21

EuropeanHome.com

TROUBLESHOOTING

OBSERVED PROBLEM:

POSSIBLE CAUSE:

A. No transmission (motor does not turn)

1. Receiver must learn new code. 2. Dead batteries.

3. The receiver is surrounded by metal, reducing the transmission range.

4. Receiver

5. Transmitter

6. Wiring at valve damaged. 7. Bent pins on 8 wire connector.

B. No ignition; no tone

1. Dead batteries. 2. Receiver

C. No ignition; no spark at pilot

1. Verify spark at receiver

2. Faulty ignitor rod or ignition wire

D. No ignition; one 5 second continu- 1. Loose wire.

ous tone (7 short beeps might be

heard prior to the 5 second tone)

2. Receiver

3. Bent pins on 8 wire connector.
4. Valve

REMEDY: 1. Reset system as above. 2. Replace batteries. 3. Change the position of the antenna.
4. Replace receiver and reprogram code as above. 5. Replace the transmitter and reprogram code as above. 6. Replace valve. 7. Straighten pins on 8 wire connector. 1. Replace batteries. 2. Replace the transmitter and reprogram code as above. 1. Replace receiver if no spark 2. Replace pilot assembly
1. Secure wire. 2. Replace receiver and reprogram code as above. 3. Straighten pins on 8 wire connector. 4. Replace valve.

E. No pilot flame and control contin- 1. Air in the pilot supply line. ues to spark
2. No spark at pilot burner.
3. Valve Gas Stones Vented Rev#07282023
22

1. Purge the line or start ignition several times.
2. Check spark gap; check wiring connection. Check for spark in location along cable.
3. Replace valve. Do not overtighten thermocouple
EuropeanHome.com

OBSERVED PROBLEM:

POSSIBLE CAUSE:

E. No pilot flame and control contin- 4. Over tightened thermocouple. ues to spark

5. Receiver

REMEDY:
4. Replace valve and thermocouple interrupter.
5. Replace receiver and reprogram code as above.

F. Pilot is lit and control continues to spark. Valve shuts off after 10-30 seconds. Valve operates manually.

1. Receiver

1. Replace receiver and reprogram code as above.

G. Pilot is lit and sparking stops. Valve shuts off after 10-60 seconds. Valve does not operate manually.

1. Not enough voltage generated from the thermocouple or too much resistance in the circuit.

1. Use a digital multimeter set in the mV range and measure the voltage between the spade connector closest to the thermocouple (-) and thermocouple tube (+) itself. The reading should be 21-30 mV.

2. Thermocouple 3. Low inlet pressure.
4. Valve

2. Replace thermocouple.
3. Confirm regulator pressure and sizing. Replace if necessary.
4. Replace valve. Do not overtighten the thermocouple.

H. Three short beeps while the motor 1. Batteries are low. turns.

1. Replace batteries.

I. Pilot flame lights but there is no main gas flow.

1. Manual override knob is in MAN position. 2. Valve turned down to pilot flow.
3. Low inlet pressure.
4. Valve.

1. Turn manual override knob to ON position.
2. Turn flame to high fire by pressing the UP button on remote control.
3. Confirm regulator pressure, and sizing. Replace valve if necessary.
4. Replace valve.

Gas Stones Vented Rev#07282023 23

EuropeanHome.com

The flames should look like those in the picture above.

PARTS LIST
Burner Module, NG Burner Module, LP Stone Kit Pilot Assembly Fusion Basket

GSBM-NG-01 GSBM-LP-01
VPK-01 VPA-01 VSB-01

For replacement parts and customer service:
Contact your local Dealer

Gas Stones Vented Rev#07282023 24

EuropeanHome.com

European Home Warranty Vision and Gas Stones Family of Products
European Home warrants the Vision, Vision Vent Free, Gas Stones and Gas Stones Vent Free burners against defects in materials and workmanship for a period of TWO (2) YEARS from the date of original retail purchase. We warrant the Vision cabinet, Vision Vent Free cabinet, Fusion Basket and Beach Stones against defects in materials and workmanship for a period of FIVE (5) YEARS from the date of original retail purchase. If a defect exists, European Home will, at its option, either (1) repair the product at no charge, using new or refurbished replacement parts or (2) exchange the product with one which is new or which has been manufactured from new or serviceable used parts and is at least functionally equivalent to the original product. A replacement product/part assumes the remaining warranty of the original product or ninety (90) days from the date of replacement or repair, whichever provides longer coverage for you. When a product or part is exchanged, any replacement item becomes your property and the replaced item becomes the property of European Home.
Nothing in the above shall be deemed to imply that this warranty shall apply to work which has been abused or neglected or shows evidence of changes or modifications by others with or without permit, damages caused by the acts of God, building settlement or moving, fire or vandalism. In addition, installation of this product that varies from the requirements stated in the instruction manual will void the warranty.
European Home is a division of Europa Ja, Inc.

PRODUCT INSTALLATION RECORD Installer: Please complete this form.
Purchased From Date of Purchase
Installed By Date of Installation Fireplace Serial Number
Fuel Type

Customer: Please retain this information.

Gas Stones Vented Rev#07282023 25

EuropeanHome.com

NOTES

Gas Stones Vented Rev#07282023 26

EuropeanHome.com

Gas Stones Vented Rev#07282023 27

EuropeanHome.com

EUROPEAN HOME
a division of Europa Ja, Inc.
30 Log Bridge Road Building 300 – Suite 303 Middleton, MA 01949 www.europeanhome.com
Gas Stones Vented Rev#07282023 28

EuropeanHome.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals