MAJESTIC Meridian 36 Modern Direct Vent Gas Fireplace Instruction Manual
- June 13, 2024
- Majestic
Table of Contents
MAJESTIC Meridian 36 Modern Direct Vent Gas Fireplace
Scan the QR code for the installation manual for the final dimensions and requirements.
ACTUAL DIMENSIONS
FRONT WIDTH| HEIGHT| DEPTH| GLASS SIZE| BTU/HOUR
INPUT
---|---|---|---|---
41″ [1041]| 40-7/8″ [1038]| 21-7/16″ [545]| 24-3/4″ x 34-1/4″ [629 X 870]|
17,000 – 34,000 BTUs (NG)
TOP VIEW
FRAMING DIMENSIONS
FRONT WIDTH| HEIGHT| DEPTH| GLASS SIZE| BTU/HOUR
INPUT
---|---|---|---|---
41″ [1041]| 40-7/8″ [1038]| 21-7/16″ [545]| 24-3/4″ x 34-1/4″ [629 X 870]|
17,000 – 34,000 BTUs (NG)
Specifications
COMBUSTIBLE MANTEL PROJECTIONS
Note : Measurement is taken from the top of the opening NOT the top of the fi1 replacement.
NON-COMBUSTIBLE MANTEL PROJECTIONS
Note: Measurement is taken from the top of the opening, NOT the top of the fireplace
COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONS
If A minimum is, then B maximum is.
A| Inches| 2-7/16| 3-7/16| 4-7/16| 5-7/16|
6-7/16| 7-7/16
Millimeters| 62| 87| 113| 138| 164| 189
B| Inches| 1| 2| 3| 4| 5| Cl)
Millimeters| 25| 51| 76| 102| 127| Cl)
NON-COMBUSTIBLE MANTEL LEGS OR WALL PROJECTIONS
If A minimum is __ , then **B maximum is __.**
A| Inches| 0-7-7/16| 7-7/16
Millimeters| 0-189| 189
B| Inches| 6| Cl)
Millimeters| 152| Cl)
If using heat management please refer to the fireplace installation manual for framing guidelines and reduced mantel clearances. Additional information on venting, TV clearances, finishing requirements, fronts, etc can be found in the installation and owner’s manual
EXTERIOR CHASE MINIMUM HEIGHT REQUIREMENTS
- NOTE : If overhang (A) is less than 2 inches, clearance from the top of the termination cap to the bottom of the overhang (B) may be 0 inches.
- Measured from the back of the vent cap to the end of the overhang
- Measured from the bottom of the overhang to the top of the termination cap Vinyl Siding Shield (TRAP-VSS) Information
- TRAP-VSS is required if overhang (A) is greater than 3 inches but less than 5 inches and B dimension is less than 18 inches.
- TRAP-VSS is recommended if either of the below is true:
- Overhang (A) is less than 5 inches (to combat water infiltration)
- A vinyl overhang is present
WALL PENETRATION
DO NOT PACK VENT FRAMING HOLES WITH INSULATION OR OTHER MATERIAL.
- Shows center of vent framing hole for top or rear venting.
- The center of the hole is one (1) in. (25 mm) above the center of the horizontal vent pipe.
PRODUCT LISTING CODES
US| ANSI Z21.88-2019
CAN| CSA 2.33-2019
| UL307B
The product information provided is not complete and is subject to change
without notice. Product installation must adhere strictly to instructions
accompanying the product to avoid the risk of fire and potential injury.