Industrial Air Circulator Instructions
For All High Velocity Fans
ECO1-8027 Industrial Air Circulator
READ AND SAVE THESE IMPORTANT INSTRUCTIONS
It is important that the following safety precautions be followed when using this product:
- DO NOT place foreign objects through guards into blades.
- DO NOT allow unit to become wet or damp.
- DO NOT use this fan with any solid state speed control device.
“NOT SUITABLE FOR USE WITH SOLID-STATE SPEED CONTROLS”
“AVERTISSEMENT; NE CONVIENT PAS A DES REGULATEURS DE VITESSE A SEMI-
CONDUCTEURS”
- WARNING: To reduce the risk of fire, electrical shock, or injury to persons, observe the following:
- Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
- Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.
- Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards,including fire-rated construction.
- When cutting into wall or ceiling, do not damage electrical wiring and other hidden utilities.
- Do not use replacement parts that have not been recommended by the manufacturer (e.g. parts made at home using a 3D printer).
INSTALLATION INSTRUCTIONS
For installation on wood structures, use a 1/2″ lag screw of appropriate
length for the application.
For installation on steel structures, use a 1/2″ bolt of the appropriate
length for the application, in combination with a flat washer, a lock washer
and a 1/2″ nut.
For installation on masonry structures, use a 1/2″ lag screw, in combination
with a lag shield, of appropriate length for the application.
In all cases, it is recommended that a flat washer be placed on both sides of
the fan yoke to assist in smooth rotation.
For three-phase models, check fan blade rotation. Blade should rotate
clockwise viewed from the air discharge side. To reverse rotation, reverse any
two leads.
For dual-voltage models, it is possible to wire the same motor for different
service voltages. Wiring diagrams are printed on the motor nameplates.
MOTOR JUNCTION BOX
WIRING DIAGRAM
OPERATING INSTRUCTIONS
This unit is single speed fan and swivel bracket, which allows you to move the
position to a desired air delivery.
During normal operation it is not uncommon for the motor to be warm to the
touch. The motor is equipped with a thermo-protector, and will automatically
de-energize the fan if it were to over heat for any reason. If this should
happen, immediately disconnect unit from power.
CLEANING/MAINTENANCE INSTRUCTIONS
All maintenance should be done by either TPI Corporation or a qualified
electrician. The motor bearings are lubricated at the factory and should not
require any additional lubrication. However, if bearing lubrication is
required, apply a small amount of a synthetic oil to the motor bearing.
Remove six retaining screws and the six grille clips on the outer ring. Remove
front guard out and off to separate from the housing. Use mild detergent to
clean the blade and guards. Avoid allowing cleanser to come in contact with
the motor windings or bearing. Then replace front guard in reverse order of
disassembly. Allow fan to dry completely before next use.
Save these important instructions. Your TPI Air Circulator carries a one year
warranty. For additional information on TPI Products or replacement parts,
call TPI Customer Service Department at
1-800-251-0382 or write the address
below.
PO. Box 4973
• Johnson City, Tennessee 37602-4973
• 423-477-4131 • FAX
423-477-0683
ECO1-8027
FORM: 8212
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>