ZKTeco RS485 ProFace X Facial Recognition
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
Overview
Installation Environment
Please refer to the following recommendations for installation.
Device Installation
Install on the wall
-
Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
-
Fix the backplate on the wall using wall mounting screws.
-
Attach the device to the backplate.
-
Fasten the device to the backplate with a security screw.
Install on the barrier gate
Please thread the wire through the bracket before installation.
-
Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut.
-
Adjust the angle of the device.
Standalone Installation
Door Sensor, Exit Button & Alarm Connection
Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock.
The NO LOCK (normally unlocked when power-on) is connected with ‘NO’ and
‘COM’ terminals, and the NC LOCK (normally locked when power-on) is
connected with ‘NC’ and ‘COM’ terminals.
Take NC Lock as an example below:
Wiegand Reader Connection
Barrier Connection
RS485 Connection
Note: 485A and 485B can be connected to the Barrier gate or the 485 Reader, separately, but cannot be connected to the gate and reader at the same time.
Power Connection
- Recommended power supply: 12V – 3A
- To share the power with other devices, use a power supply with higher current ratings.
Ethernet Connection
Connect the device and computer software over an Ethernet cable. An example is
shown below:
Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to ZKBioSecurity software.
Click on [Comm.] > [Ethernet] > [IP Address], input the IP address and click on [OK].
UserRegistration
When there is no super administrator set in the device, click on to enter the menu. After setting the super administrator, the system will request for the administrator’s verification before entering the menu. For the security purpose, it is recommended to register a super administrator at the first time you use the device.
Method1: Register on the device
Clickon> [User Mgt.] > [New User] to register a new user. Settings include
entering user ID and name, face, password and profile photo, setting user role
and access control role.
Method2: Register on ZKBioSecurity software
Please set the IP address and cloud service server address in the Comm. Menu
option on the device.
-
Click [Access] > [Access Device] > [Device] > [Search Device] to search the device on the software. When an appropriate server address and port is set on the device, the searched devices are displayed automatically.
-
Click [Add] in operation column, a new window will pop-up. Select Icon type, Area, and Add to Level from each dropdowns and click [OK ] to add the device.
-
Click [Personnel] > [Person] > [New] and fill in all the required fields to register a new users in the software.
-
Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices] to synchronize all the data to the device including the new users.
For more details, please refer to the ZKBioSecurity User Manual.
Method 3: Register on the phone
Once ZKBioSecurity software installed, users could enroll face via browser
application on their own mobile phone
-
Click [Personnel] > [Parameters], input ‘’http://Server address: Port’’ in the QR Code UGL bar. The software will automatically generate a QR code. Scan the QR code or login onto ‘’http://Server address:
Port/app/v1/adreg’’ by the mobile phone to register users.
-
The users will be displayed in [Personnel] > [Temporary Personnel], click [Review].
Access Control Settings
Click on > [Access Control] to enter the access control management interface
and set relevant parameters of access control.
Ethernet and Cloud Server Settings
Click on > [Comm.] > [Ethernet] to set the network parameters. If the TCP/IP
communication of the device is successful, the icon will be displayed in the
upper right corner of the standby interface.
Click on > [Comm.] > [Cloud Server Setting] to set the server address and
server port, that is, the IP address and port number of the server after the
software is installed. If the device communicates with the server
successfully, the icon will be displayed in the upper right corner of the
standby interface.
ZKTeco Industrial Park, No. 32, Industrial Road,
Tangxia Town, Dongguan, China.
Phone : +86 769 – 82109991
Fax : +86 755 – 89602394
www.zkteco.com
Documents / Resources
|
ZKTeco RS485 ProFace X Facial
Recognition
[pdf] User Guide
RS485 ProFace X Facial Recognition, RS485, ProFace X, Facial Recognition
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>