ME3-O3 gas sensor

ME3-O3 electrochemical sensor detect gas concentration by measuring current based on the electrochemical principle, which utilizes the electrochemical oxidation process of target gas on the working electrode inside the electrolytic cell, the current produced in electrochemical reaction of the target gas are in direct proportion with its concentration while following Faraday law, then concentration of the gas could be get by measuring value of current.

Features

  • Low consumption
  • High precision
  • High sensitivity
  • Wide linear range
  • Good anti-interference ability
  • Excellent repeatability and stability

Application

Widely used in industrial and environmental protection fields

Technical Parameter

Detection gas O3
Measurement Range 0~10ppm
Max detecting concentration 50ppm
Sensitivity (1.2±0.3)µA/ppm
Resolution ratio 0.05ppm
Response time(T90) ≤120S
Bias voltage 0mV
Load resistance 10Ω(recommended)
Repeatability <5﹪output value
Stability(/month) <2﹪
Output Linearity linear
Zero drift(-20℃~40℃) ≤0.2ppm
Storage temperature -20℃~50℃
Storage Humidity 15﹪~90﹪RH
Pressure range Standard atmosphere pressure ±10%
Anticipated using life 2 years(In air)

External dimension

External dimension

Characterization

Features of Sensitivity, response and resume

Characterization

Linearity features

Characterization

Zero point change upon Variable Temperature

Characterization

Output upon variable temperature

Characterization

Basic circuit

Basic circuit

Basic circuit

Anti-Interference:

ME3-O3 sensor also responds to other gases besides target gas. Below are the response characteristics of interferential gases

Gas Concentration ME3-O3
CL2 3ppm 1ppm
H2S 15ppm <-1ppm
CO 300ppm 0ppm
SO2 5ppm 0ppm
HCN 10ppm 0ppm
HCL 5ppm 0ppm
NO 35ppm 0ppm
NO2 5ppm 2ppm
H2 500ppm 0ppm
C2H4 100ppm 0ppm

Application Notes:

  • Sensor shall Avoid organic solvent, coatings, medicine, oil and high concentration gases;
  • All ME Sensors shall not be encapsulated completely by resin materials, and shall not immerse in pure oxygen environment, otherwise, it will damage the function of sensor;
  • All ME sensors shall not be applied in corrosive gas environment, or the sensor will be damaged;
  • Please test the sensitivity of gas sensors in clean atmosphere;
  • Sensors Shall be avoided to face the gas, which flow directly from front side;
  • To avoid to bend and break of pins;
  • Blowhole of the sensor should not be blocked and polluted, which will cause the sensitivity decrease;
  • Excessive impact or vibration should be avoided;
  • Do not use the sensor when the shell is damaged;
  • It takes some time for the sensor to return to normal state After applied in high concentrations;
  • Do not take apart the sensor, otherwise electrolyte leakage can cause sensor damage;
  • Working electrode and reference electrode of the sensor shall be in short circuit when stored.;
  • To preheat over 48hs before using and soldering forbidden;

Note: To keep continual product development, we reserve right to change design features without prior notice!

Customer Support

Zhengzhou Winsen Electronics Technology Co., Ltd
Add.:
NO.299 Jin Suo Road, National Hi-Tech Zone, Zhengzhou, 450001 China
Tel.: 0086-371-67169097
Fax:0371-60932988
E-mail: sales@winsensor.com

Tel: 86-371-67169097 Fax: 86-371-60932988
Email: sales@winsensor.com
Leading gas sensing solutions supplier in China

Zhengzhou Winsen Electronics Technology Co., Ltd
www.winsen-sensor.com

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals