eurolite PAR-64 COB 3000K 100W LED Zoom Audio Light User Manual
- June 13, 2024
- eurolite
Table of Contents
User Manual
PAR-64 COB 3000K 100W LED Zoom Audio Light
LED PAR-64 COB 3000K Zoom
PAR-Scheinwerfer mit warmweißer 100-Watt-COB-LED
PAR spot with warm white 100 W COB LED
No. 41603600
www.eurolite.de
This user manual is valid for the article number: 41603600
You can find the latest update of this user manual in the Internet under:
www.eurolite.de
DANGER! Electric shock caused by short-circuit
Be careful with your operations. With a dangerous voltage you can suffer a
dangerous electric shock when touching the wires. Never open the housing. Keep
the device away from rain and moisture.
Please read these instructions carefully before using the product. They
contain important information for the correct use of the product.
Every person involved with the installation, operation and maintenance of this device has to
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
INTRODUCTION
Thank you for having chosen one of our products. If you follow the instructions given in this manual, we are sure that you will enjoy this device for a long period of time.
Product features
PAR spot with warm white 100 W COB LED
- Ideal as front light for theaters and any other place requiring much white light
- Light performance comparable to a traditional 1000 W halogen spot light
- 1 high-performance 100 W COB LED
- Color temperature: 3000 K
- Very high color rendering index (CRI >90)
- Homogeneous light distribution
- Manual beam angle adjustment 11- 35°
- 5 different dimmer curves selectable
- Strobe effect with adjustable speed
- Dimmer frequency adjustable 900-25000 Hz
- Gamma correction adjustable
- Flicker-free projection
- 1, 2 or 3 DMX channels selectable
- Addressing and setting via control panel with 4-digit LED display
- With color filter frame
- Swivel mounting bracket
- DMX512 control possible via any commercial DMX controller
- P-Con power input and feed-through output to power up to 8 devices
SAFETY INSTRUCTIONS
WARNING!
Please read the safety warnings carefully and only use the product as describe
in this manual to avoid accidental injury or damage.
Intended use
- This device is an LED projector for creating decorative lighting effects. This device is designed for professional use in the field of event technology, e.g. on stage. It is not suitable for household lighting.
- Only use the device according to the instructions given herein. Damages due to failure to follow these operating instructions will void the warranty! We do not assume any liability for any resulting damage.
- We do not assume any liability for material and personal damage caused by improper use or noncompliance with the safety instructions. In such cases, the warranty/guarantee will be null and void.
- Unauthorized rebuilds or modifications of the device are not permitted for reasons of safety and render the warranty invalid.
Danger due to electricity
- The device is suitable for indoor use only. Do not use it outdoors. Never expose it to rain or moisture. Do not store it in rooms exposed to moisture.
- To reduce the risk of electric shock, do not open any part of the device. There are no serviceable parts inside the device.
- Only connect the device to a properly installed mains outlet. The outlet must be protected by residual current breaker (RCD). The voltage and frequency must exactly be the same as stated on the device. If the mains cable is equipped with an earthing contact, then it must be connected to an outlet with a protective ground. Never defeat the protective ground of a mains cable. Failure to do so could result in damage to the device and possibly injure the user.
- The mains outlet must be easily accessible so that you can unplug the device quickly if need be.
- Never touch the mains plug with wet or damp hands. There is the risk of potentially fatal electric shock.
- The mains cable must not be bent or squeezed. Keep it away from hot surfaces or sharp edges.
- Never pull the mains cable to disconnect the mains plug from the mains outlet, always seize the plug.
- Unplug the device during lighting storms, when unused for long periods of time or before cleaning.
- Do not expose the device to any high temperatures, direct sunlight, dripping or splashing water, strong vibrations or heavy mechanical stress.
- Do not place any objects filled with liquids on the device.
- Do not place any open sources of fire, such as burning candles, on or directly next to the device.
- Make sure that objects cannot fall into the device, in particular metal parts.
- Only have repairs to the device or its mains cable carried out by qualified service personnel. Repairs are required when the device or the mains cable is visibly damaged, liquid has been spilled or objects have fallen into the device; when the device has been exposed to rain or moisture, has been dropped or malfunctions occur.
- Cleaning of the device is limited to the surface. Make sure that moisture does not come into contact with any areas of the terminal connections or mains voltage control parts. Only wipe off the product with a soft lint-free and moistened cloth. Never use solvents or aggressive detergents.
Danger to children and people with restricted abilities
- This product is not a toy. Keep it out of the reach of children and pets. Do not leave packaging material lying around carelessly. Never leave this device running unattended.
- This device may be used only by persons with sufficient physical, sensorial, and intellectual abilities and having corresponding knowledge and experience. Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety.
Warning – risk of burns and fire
- The admissible ambient temperature range (Ta) is -5 to +45°C. Do not operate the device outside of this temperature range.
- The housing temperature (Tc) can be up to 100°C during use. Avoid contact by persons and materials.
- Do not illuminate surfaces within 50 cm of the device. This value is indicated on the device by the symbol.
- Do not use the device near highly flammable materials. Always place the device at a location where sufficient air circulation is ensured. Leave 50 cm of free space around the device. Never cover the air vents of the housing.
Warning – risk of injuries
-
Do not look directly at the light source. Persons with light-sensitive epilepsy may suffer from epileptic seizures or fall unconscious.
-
Make sure that the product is set up or installed safely and expertly and prevented from falling down.
Comply with the standards and rules that apply in your country, in particular EN 60598-2-17. -
If you lack the qualification, do not attempt the installation yourself, but instead use a professional installer.
Improper installation can result in bodily injury and or damage to property. -
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety precautions.
-
For overhead use, always secure the device with a secondary safety attachment such as a safety bond or safety net.
-
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the device.
-
For commercial use the country-specific accident prevention regulations of the government safety organization for electrical facilities must be complied with at all times.
Caution – material damage
- This device must not be connected to the mains voltage by means of a dimmer.
- Lighting effects are not designed for permanent operation. Consistent operation breaks will ensure that thedevice will serve you for a long time without defects.
- Never switch the device on and off in short intervals. This will considerably reduce the service life of thedevice.
- If the device has been exposed to drastic temperature fluctuation, do not switch it on immediately. Theresulting condensation may destroy the device. Allow the device to reach room temperature beforeconnecting it. Wait until the condensation has evaporated.
- Please use the original packaging to protect the device against vibration, dust and moisture duringtransportation or storage.
- If a serial number label is affixed to the device, do not remove the label as this would make the guaranteevoid.
DESCRIPTION OF THE DEVICE
(1) Display
(2) Operation buttons
• MENU: To adjust functions
• UP / DOWN: To switch between the menu items
• ENTER: To confirm settings
(3) Power input
(4) Power feed-through output| (5) Safety rope
(6) Fuse holder
(7) DMX output
(8) DMX input
---|---
Adjusting the beam angle
The beam angle can be adjusted manually from 11° to 35°.
INSTALLATION
WARNING! Risk of injury caused by falling objects
Devices in overhead installations may cause severe injuries when crashing
down. Make sure that the device is installed securely and cannot fall down.
The installation must be carried out by a specialist who is familiar with the
hazards and the relevant regulations.
The device may be placed on the floor or fastened to a truss or similar rigging structure. The device must never be fixed swinging freely in the room.
- The rigging structure must support at least 10 times the weight of all fixtures to be installed on it.
- Block access below the work area and work from a stable platform when installing the device.
- Use rigging hardware that is compatible with the structure and capable of bearing the weight of the device. Please refer to the “Accessories” section for a list of suitable rigging hardware.
- Secure the device with a safety bond or other secondary attachment. This secondary safety attachment must be sufficiently dimensioned in accordance with the latest industrial safety regulations and constructed in a way that no part of the installation can fall down if the main attachment fails. An appropriate eyelet is mounted on the device for fixation of the safety rope. Fasten the safety rope in such a way that, in the event of a fall, the maximum drop distance of the device will not exceed 20 cm.
- To align the device, release the fixation screws at the mounting bracket, adjust the desired inclination angle and retighten the fixation screws.
- After installation, the device requires inspections periodically to prevent the possibility of rot, deformation and looseness.
CONNECTIONS
DMX512 control
A DMX512 data link is required in order to control the device via DMX. The
device provides 3-pin XLR connectors for DMX connection.
- Connect the output of your DMX controller to the DMX input DMX IN of the device with a DMX cable.
- Connect the DMX output DMX OUT of the device to the DMX input of the next unit in the chain. Always connect one output to the input of the next unit until all units are connected.
- At the last unit, the DMX cable has to be terminated. Plug the terminator with a 120 Ω resistor between Signal (–) and Signal (+) in the DMX output of the last unit.
- If the cable length exceeds 300 m or the number of DMX devices is greater than 32, it is recommended to insert a DMX level amplifier to ensure proper data transmission.
XLR connection:
Connection to the mains
The device uses an auto-range power supply that accepts input voltages between
100 und 240 volts.
- Connect the device via the mains cable to a grounded mains socket. Thus the unit is switched on.
- To switch off the unit, disconnect the power plug.
- Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains outlet which is switchable.
Power supply of further devices
The jack POWER OUT allows for power supply of further devices. To interconnect
several devices, connect the jack POWER OUT to the input POWER IN of the next
unit until all units are connected. Matching power cables with P-Con plugs are
available as accessories. In this manner, up to 8 devices can be linked at
230/240 input voltage and up to 4 devices at 110/115 input voltage.
OPERATION
After connecting the device to the mains it is ready for operation. The
display indicates the last operating mode. The operating modes can be selected
by means of the display and the control buttons. All settings remain stored
even if the device is disconnected from the mains. The device can be operated
in stand-alone mode via the control board or in DMX-controlled mode via any
commercial DMX controller.
Menu structure
Press the MENU button so many times until the desired function is indicated on
the display. Use the ENTER button to select the function. With the buttons UP
and DOWN you can select the mode. Confirm with ENTER. If you do not do so, the
device goes back to the main functions after 20 seconds without saving your
settings. If you wish to go back to the main functions without saving your
settings, press MENU.
Mode| Display
Function
---|---
DMX operation| Addr| A001-A512| Start address
Chnd| 1CH| 1-channel mode
2CH| 2-channel mode
3CH| 3-channel mode
Dimmer curve| dInd| StdA| Standard
StgE| Stage
tv| TV
ArAL| Architectural
thAL| Theatre
Dimmer frequency| Freq| 900| 900 Hz
1000| 1000 Hz
1100| 1100 Hz
1200| 1200 Hz
1300| 1300 Hz
1400| 1400 Hz
1500| 1500 Hz
2500| 2500 Hz
4000| 4000 Hz
5000| 5000 Hz
10k| 10000 Hz
| | 15k| 15000 Hz
---|---|---|---
20k| 20000 Hz
25k| 25000 Hz
Gamma settings|
gAmm
| no| 0
2.0| 2.0
2.2| 2.2
2.4| 2.4
2.6| 2.6
2.8| 2.8
Manual mode| nAnu| 0-255| Brightness 0-100%
Behavior in case of missing DMX signal|
Lost
| Hold| Most recent DMX value is held
Blackout| LEDs switched off
Temperature| temp| xx| Internal temperature
Display deactivation
|
LEd
| On| Deactivation after 20 seconds
oFF| Display always active
Display reverse
|
dISP
| On| Display reversed
oFF| Display normal
Working hours| FhrS| xx| Total working hours
Software version| ver| xx| Current software version
Default| deFA| Reset to default settings
DMX operation
Setting the number of DMX channels and the DMX starting address
For operation with a controller with DMX512 protocol, the device is equipped
with 3 control channels.
However, it can also be switched to a mode with 1 or 2 channels if different
functions are required. To be able to operate the device with a DMX
controller, the DMX starting address must be set for the first DMX channel.
The starting address depends upon which DMX controller is being used. Please
refer to the controller’s documentation.
- Press the MENU button so many times until Addr is indicated in the display. Confirm with the ENTER button. Use the buttons UP and DOWN to select the desired DMX address. Confirm with the ENTER button again.
- Press the MENU button so many times until Chnd is indicated in the display. The display indicates 1 CH (1 DMX channel), 2 CH (2 DMX channels) or 3 CH (3 DMX channels). Use the buttons UP and DOWN to select the desired number of DMX channels. Confirm with the ENTER button.
- A dot will be flashing when DMX signals are being received.
Note : Please make sure that you do not have any overlapping channels in order to control each device correctly and independently from any other fixture on the DMX chain. If several devices are addressed similarly, they will work synchronically.
Functions in DMX mode
1-channel mode
Channel | Function | Value | Details |
---|---|---|---|
CH1 | Master dimmer | 000 – 255 | Total brightness 0-100% |
2-channel mode
Channel | Function | Value | Details |
---|---|---|---|
CH1 | Master dimmer | 000 – 255 | Total brightness 0-100% |
CH2
| ****
Strobe
| 000 – 015| LED on
016 – 095| Strobe effect (1-25 Hz) with increasing speed
096 – 175| Pulse effect (1 Hz) with decreasing pulse width
176 – 255| Random strobe effect with increasing speed
3-channel mode
Channel | Function | Value | Details |
---|---|---|---|
CH1 | Master dimmer | 000 – 255 | Total brightness 0-100% |
CH2 | Fine dimmer | 000 – 255 | Fine dimmer (16 bit) 0-100% |
CH3
| ****
Strobe
| 000 – 015| LED on
016 – 095| Strobe effect (1-25 Hz) with increasing speed
096 – 175| Pulse effect (1 Hz) with decreasing pulse width
176 – 255| Random strobe effect with increasing speed
CLEANING AND MAINTENANCE
The outside of the device should be cleaned periodically to remove contaminants such as dust etc. The lens, in particular, should be clean to ensure that light will be emitted at maximum brightness.
- Disconnect the device from power and allow it to cool before cleaning.
- Clean the surface with a soft lint-free and moistened cloth. Never use alcohol or solvents as these may damage the surface. Make sure that no liquids can enter the device.
- The device must be dry before reapplying power.
There are no serviceable parts inside. Do not open the housing. Do not try to repair the device by yourself as this may result in damage. Maintenance and service operations are only to be carried out by authorized dealers. Should you need any spare parts, please use genuine parts. Should you have further questions, please contact your dealer.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of
same type and rating.
- Disconnect the device from power and allow it to cool.
- Open the fuse holder of the mains connection with a fitting screwdriver.
- Remove the old fuse from the fuse holder and replace it with a new fuse.
- Carefully push the fuse holder back into its position before reapplying power.
PROTECTING THE ENVIRONMENT
Disposal of old equipment
When to be definitively put out of operation, take the product to a local
recycling plant for a disposal which is not harmful to the environment.
Devices marked with this symbol must not be disposed of as household waste.
Contact your retailer or local authorities for more information.
Remove any inserted batteries and dispose of them separately from the product.
You as the end user are required by law (Battery Ordinance) to return all used
batteries/ rechargeable batteries. Disposing of them in the household waste is
prohibited. You may return your used batteries free of charge to collection
points in your municipality and anywhere where batteries/rechargeable
batteries are sold. By disposing of used devices and batteries correctly, you
contribute to the protection of the environment.
TECHNICAL SPECIFICATIONS
Power supply: | 100-240 V AC, 50/60 Hz |
---|---|
Power consumption: | 110 W |
Protection class: | I |
Fuse: | T1A, 250V |
DMX channels: | 1/2/3 |
DMX connection: | 3-pin XLR |
Flash-rate: | 0-25 Hz |
LED number: | 1 |
LED type: | 100 W COB, warm white |
Color temperature: | 3000 K |
Beam angle: | 11-35° |
Dimensions (L x W x H): | 435 x 260 x 375 mm |
Weight: | 3.3 kg |
All information is subject to change without prior notice. © 15.06.2018
Accessories
EUROLITE TPC-10 coupler, silver | No. 59006856 |
---|---|
EUROLITE Safety rope A 3×600 mm up to 5 kg, silver | No. 58010310 |
EUROLITE DMX cable XLR 3-pin 3m, black | No. 3022785H |
PSSO DMX Cable XLR 3-pin 3m, black, Neutrik | No. 30227810 |
PSSO PowerCon connection cable 3×1.5 3m | No. 3023503R |
EUROLITE DMX LED Color Chief Controller | No. 70064575 |
EUROLITE QuickDMX wireless transmitter | No. 70064700 |
EUROLITE QuickDMX wireless receiver | No. 70064701 |
Eurolite is a brand of Steinigke Showtechnic GmbH
Andreas-Bauer-Str. 5 97297 Waldbüttelbrunn Germany
D00117370 Version 1.0 Publ. 15/06/2018
Documents / Resources
|
eurolite PAR-64 COB 3000K 100W LED Zoom Audio
Light
[pdf] User Manual
41603600, PAR-64 COB 3000K 100W LED Zoom Audio Light, 100W LED Zoom Audio
Light, LED Zoom Audio Light, Audio Light, Light
---|---