MEAN WELL LPV-60 series LED Power Supply Owner’s Manual
- June 13, 2024
- MEAN WELL
Table of Contents
MEAN WELL LPV-60 series LED Power Supply Owner’s Manual

Features
- Constant voltage design
- Universal AC input/Full range
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Over load / Over voltage
- Cooling by free air convection
- Fully encapsulated with IP67 level (Note.7)
- Fully isolated plastic case
- Class II power unit, no FG
- Class 2 power unit
- Pass LPS
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices) (Note.11)
- 100% full load burn-in test
- Low cost, high reliability
- 2 years warranty
SPECIFICATION
MODEL|  LPV-60-5|  LPV-60-12|  LPV-60-15|  LPV-60-24|
LPV-60-36|  LPV-60-48
---|---|---|---|---|---|---
OUTPUT|  DC VOLTAGE|  5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT|  8A| 5A| 4A| 2.5A| 1.67A| 1.25A
CURRENT RANGE|  0 ~ 8A| 0 ~ 5A| 0 ~ 4A| 0 ~ 2.5A| 0 ~ 1.67A| 0 ~ 1.25A
RATED POWER|  40W| 60W| 60W| 60W| 60W| 60W
RIPPLE & NOISE (max.) Note.2|  80mVp-p| 120mVp-p| 120mVp-p| 150mVp-p|
150mVp-p| 150mVp-p
VOLTAGE TOLERANCE Note.3|  ±8.0%| ±5.0%
LINE REGULATION|  ±1.0%
LOAD REGULATION|  ±6.0%| ±2.0%
SETUP, RISE TIME Note.6|  500ms, 20ms / 230VAC 500ms, 20ms / 115VAC
at full load(for 5~36V) ; 500ms, 30ms / 230VAC  500ms, 30ms / 115VAC at full
load(for 48V)
HOLD UP TIME (Typ.)|  50ms/230VAC        16ms/115VAC at full load
INPUT|  VOLTAGE RANGE Note.4|  90 ~ 264VAC       127 ~ 370VDC
FREQUENCY RANGE|  47 ~ 63Hz
EFFICIENCY (Typ.)|  76%| 83%| 83%| 86%| 86%| 86%
AC CURRENT (Typ.)|  1.2A/115VAC 1A/230VAC
INRUSH CURRENT(Typ.)|  COLD START 60A(twidth=525μs measured at 50% Ipeak)
at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER|  3 units (circuit breaker of
type B) / 6 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT|  0.25mA / 240VAC
PROTECTION|  OVER LOAD|  110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE|  5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 27.6 ~ 32.4V|
41.4 ~ 48.6V| 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT|  WORKING TEMP.|  -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY|  20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY|  -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT|  ±0.03%/℃ (0 ~ 50℃)
VIBRATION|  10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SAFETY & **EMC|  SAFETY STANDARDS|  UL879(except for LPV-60-5),
UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5,
LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS
IS15885(Note 12),EAC TP TC 004, IP67, IEC62368-1 , BS EN/EN62368-1 approved
WITHSTAND VOLTAGE|  I/P-O/P:3KVAC
ISOLATION RESISTANCE|  I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION|  Compliance to BS EN/EN55032 (CISPR32) Class B, BS
EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY|  Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55035, light industry level, EAC TP TC 020
OTHERS|  MTBF|  5188.4K hrs min.    Telcordia SR-332 (Bellcore) ;
732.1Khrs min.     MIL-HDBK-217F (25℃)
DIMENSION|  162.542.532mm (LWH)
PACKING|  0.4Kg; 32pcs/13.8Kg/0.63CUFT
NOTE**|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltage. Please check the static characteristics for more details.
- The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- Products sourced from the Americas regions may not have the TUV/BIS/CCC logo. Please contact your MEAN WELL sales for more information.
- For any application note and IP water proof function installation caution, please refer our user manual before using.
- https://[www.meanwell.com/Upload/PDF/LED_EN.pdf](http://www.meanwell.com/Upload/PDF/LED_EN.pdf)
- This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)
- Products sourced from the China regions may have the BIS logo, please contact your MEAN WELL sales for more information.
Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Mechanical Specification

Recommend Mounting Direction

Block Diagram

Derating Curve

Static Characteristics

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>