Product Information
- Product Name: Fixture #N7985-420
- Model Number: #7985-420
Installation Instructions
-
WARNING! Shut off power at the fuse or circuit breaker before proceeding.
-
Assemble the fixture (Refer to Fig. 1 & Fig.3 in the user manual):
- Shut off power at the fuse box or circuit breaker box and remove the old fixture along with the mounting hardware.
- Unpack the new fixture and lay out all the parts in a clean area, taking care not to misplace any small parts required for installation.
- Determine the desired height and thread rods (G1 and G2) together. Thread loop (I1) to rod (G1). Pass wires carefully through each rod as you assemble.
- Attach quick link (H) to loop (I2) on canopy (D). Carefully feed the wire through the loop (I1), quick link (H), and loop (I2). Assemble the bottom end of the rod into coupling (J).
- Attach circular strap (B) to the junction box using junction box screws (C). Ensure that the side of the circular strap (B) marked GND faces out. The mounting screw can be adjustable if necessary.
- The support cable is provided to support the weight of the fixture while wiring. Align the fixture to circular strap (B) and attach the hook on the end of the support cable (E) into a slot located on circular strap (B). Carefully allow the support cable (E) to support the weight of the fixture while wiring.
-
Connecting the Wires (Refer to Fig. 2 in the user manual):
- Connect the electrical wires as shown in Fig. 2, ensuring that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the circular strap (B) using the green screw provided.
- Tuck wire connectors neatly inside the junction box.
-
Completing the Installation (Refer to
Fig. 1 in the user manual):- Raise the fixture over mounting screws (A) and secure it with decorative knobs (F).
- Place candle covers (K) over the sockets (L).
- Install six candelabra base bulbs (M) up to 60 watts each or CFL or LED equivalent (not included) according to the fixture specification.
- DO NOT EXCEED THE MAXIMUM WATTAGE RATING!
Your installation is now complete. Turn on the power supply of the junction box to test the fixture.
Note: The illustration (Fig. 1) in this manual is for installation purposes only and may or may not be identical to the fixture purchased.
INSTALLATION INSTRUCTION
WARNING! SHUT THE POWER OFF AT THE FUSE OR CIRCUIT BREAKER.
ASSEMBLE THE FIXTURE (FIG. 1 & FIG.3)
-
Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
-
Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.
-
Determine the desired height and thread rods (G1 and G2) together. Thread loop (I1) to rod (G1). Pass wires carefully through each rod as you assemble.
-
Attach quick link (H) to loop (I2) on canopy (D). Carefully feed the wire through loop (I1), quick link (H) and loop (I2). Assemble the bottom end of rod into coupling (J).
-
Attach circular strap (B) to junction box using junction box screws (C). The side of circular strap (B) marked “GND” must face out. The mounting screw can be adjustable if necessary.
-
The support cable is provided to support the weight of the fixture
while wiring. Align the fixture to circular strap (B) and attach the hook on the end of support cable (E) into a slot located on circular strap (B). Carefully allow support cable (E) to support the weight of the fixture while wiring. CONNECTING THE WIRES (FIG. 2) -
Connect the electrical wires as shown in Fig. 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the circular strap (B) using the green screw provided.
-
Tuck wire connectors neatly inside the junction box. COMPLETING THE INSTALLATION (Fig. 1)
-
Raise the fixture over mounting screws (A) and secure with decorative knobs (F).
-
Place candle covers (K) over the sockets (L).
-
Install (6) six candelabra base bulbs (M) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification—DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!).
Your installation is now complete. Turn on the power supply of the junction box to test the fixture
Note: The illustration (Fig. 1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.