METROPOLITAN N7814-726 Soho 4-Light Coal and Soft Brass Cage Pendant Instruction Manual
- October 30, 2023
- Metropolitan
Table of Contents
METROPOLITAN N7814-726 Soho 4-Light Coal and Soft Brass Cage Pendant Instruction Manual
MOUNTING THE FIXTURE (Fig.1)
1. Shut off power at the fuse box or circuit breaker box and remove the old
fixture including the mounting hardware.
2. Carefully unpack your new fixture and lay out all the parts in a clean
area. Take care not to misplace any small parts necessary for installation.
3. Place metal frame (J) over metal tube (K) and secure with screws (I).
4. Determine the desired hanging height and thread rods (F1, F2 and F3) to
all thread (G) on fixture body. Attach canopy (D) by threading onto rod (F1).
Carefully feed wires through each rod as you assemble. Note: Remove all
thread, if installing with one 6” rod only.
5. Attach mounting plate (A) to junction box (Not included) with mounting
screws (B) (Size: #8-32N*L0.5”). The side of mounting plate (A) marked “GND”
and two convex points must face out.
CONNECTING THE WIRES (Fig. 2)
6. Connect the electrical wires as shown in Fig 2, making sure that all wire
connectors are secured. If your junction box has a ground wire (green or bare
copper), connect fixture’s ground wire to it. Otherwise, connect the fixture’s
ground wire directly to mounting plate (A) using green screw provided.
7. Tuck wire connectors neatly inside the junction box.
FINISHING THE INSTALLATION (Fig.1)
8. Place canopy (D) over mounting plate (A) and secure with screws (E).
9. Place glass panel (H) into metal frame (J) and secure with tabs provided.
10. Install (4) four medium base bulbs (L) up to 60 watts each or CFL or LED
equivalent (not included) in accordance with the fixture specification. — DO
NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE
NOMINALE MAXIMALE!)
Your installation is now complete. Return power to the junction box and test the fixture.
Note: Illustration (Fig.1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.
PREPARATION (Fig.3 &4)
1. Loosen hex nut (O) by using wrench (M) (Not included). Carefully remove
washer (P), lock washer (Q), metal plate (N), canopy (D) and swivels (S)
(Fig.4). Cut down a length of wire if the wire is too long.
2. Secure the metal tube (R) into the all thread (G).
3. Thread canopy (D), metal plate (N), lock washer (Q), washer (P) and hex
nut (O) into the all thread on top of metal tube (R). Then secure hex nut (O)
by using wrench (M)(Not included) .(Fig. 3)
4. Place metal frame (J) over metal tube (K) and secure with screws (I).
5. Attach mounting plate (A) to junction box (Not included) with mounting
screws (B) (Size: #8-32N*L0.5”). The side of the mounting plate (A) marked
“GND” and two convex points must face out.
CONNECTING THE WIRES (Fig. 2)
6. Connect the electrical wires as shown in fig 2, making sure that all wire
connectors are secured. If your junction box has a ground wire (green or bare
copper), connect the fixture’s ground wire to it. Otherwise, connect the
fixture’s ground wire directly to the mounting plate (A) using the green screw
provided.
7. Tuck wire connectors neatly into the junction box.
FINISHING THE INSTALLATION (Fig.3)
8. Place canopy (D) over mounting plate (A) and secure with screws (E).
9. Install the glass panel (H) into metal frame (J) and secure with tabs
provided.
10. Install (4) four medium base bulbs (L) up to 60 watts each or CFL or LED
equivalent (not included) in accordance with the fixture specification. — DO
NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE
NOMINALE MAXIMALE!)
Your installation is now complete. Return power to the junction box and test the fixture.
Note: Illustration (Fig.3) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>