MEDCURSOR FE-7208MD Air Compression LEG Massager User Manual
- June 13, 2024
- MEDCURSOR
Table of Contents
- IMPORTANT SAFEGUARDS
- GETTING TO KNOW LEG MASSAGER
- SPECIFICATION
- CONTROL PANEL
- PACKAGE CONTENTS
- BEFORE FIRST USE
- OPERATING INSTRUCTIONS
- FAQS
- Under what circumstances should I not use it?
- How many times can I use it in a day?
- How does this product work?
- Can it be used for other parts than feet, calves, and thighs?
- What size feet, calves and thighs of users are suitable for?
- The strength is too strong or too weak.
- The air in the massager hose does not exhaust .
- I can hear some weird sounds on the massager. Is it abnormal?
- Can I use only one leg?
- CARE & MAINTENANCE
- TROUBLESHOOTING
- FCC STATEMENT
- WARRANTY INFORMATION
- CUSTOMER SUPPORT
- Thank You
- Documents / Resources
MEDCURSOR FE-7208MD Air Compression LEG Massager User Manual
IMPORTANT SAFEGUARDS
- PRECAUTIONS TO ENSURE SAFE AND RELIABLE OPERATION:
- DO NOT insert any foreign objects into the openings.
- DO NOT attempt to disassemble the unit.
- DO NOT crumple or crush the massager by any means.
- DO NOT place the unit in direct sunlight nor store in dusty places or with high humidity.
- To avoid any possibility of accidental strangulation, keep this unit away from children. Do not drape tubing around the neck.
- Ensure that children do not touch the unit unsupervised; some parts may be swallowed.
- DO NOT use the device near strong electrical or electromagnetic fields generated by cell phones or other devices. This may cause interference or become interference source to the device.
- Any modification to the unit shall be prohibited.
- The product (air compression leg massager) is for adult use only.
MEDICAL DISCLAIMER:
If you’re seeking medical advice, diagnoses, or treatment, please consult a physician to confirm if the product is clinically safe for you to use. This air compression leg massager is not intended for use if you have any of the following medical conditions:
- Presumptive evidence of congestive heart failure where increase in blood returned to the heart could be detrimental.
- Pre-existing deep vein thrombosis (DVT) or blood clots.
- Existing hemorrhagic disease or coagulation problems.
- Thrombophlebitis.
- Pulmonary embolism.
This product should not be utilized by individuals with edema, ischemic vascular disease, or severe peripheral neuropathy.
SAFETY PRECAUTION:
- DO NOT plug the unit to a power source that’s beyond its voltage requirement.
- DO NOT use this product in a high-temperature environment.
- DO NOT touch the unit with any sharp object or risk damage.
- Stop using the product immediately if you feel uncomfortable or any abnormalities occur
- DO NOT attempt to repair or dismantle the product by yourself or a third party. This will void the warranty.
- DO NOT place the unit in a place where it may be in contact with flammable items, explosive objects, or chemicals.
- DO NOT use this product if any of the below apply to you: -Skin is infected, swollen, burnt or otherwise damaged. The product should be used in healthy skin.
- DO NOT use the product in a damp place or where it may get wet. If the unit gets wet, do not use it.
PLEASE DO NOT USE THE PRODUCT WHEN YOU HAVE THE FOLLOWING MEDICAL CONDITIONS:
- You have a pacemaker or any other medical implant
- You are suffering from heart disease.
- You are suffering from diabetes.
- Your bones are fragile or injured.
- You are suffering from cancer.
- You are receiving treatment or your blood pressure is not normal.
- You are suffering from osteoporosis.
- You are currently pregnant or having menstruation.
- Children or adolescents who are developing physically.
The air pressure hose connected to each boot can not be pulled out. Please do not try to remove it from the boot.
GETTING TO KNOW LEG MASSAGER
The function of an air compression leg massager is to temporarily reduce minor muscle aches and pains and to temporarily improve circulation to the treated foot, calf, and thigh in healthy individuals. By using air-inflatable boots, the unit mimics the kneading and stroking of tissues.
PRODUCT DIAGRAM
- Air Compression Boots(Left/Right)
- Air Pressure Hoses(Left/Right)
- Port for Air Pressure Hose Connector
- Velcro Strap
- LCD Screen
- Remote Control
- Control Panel
- Adapter
SPECIFICATION
Model: | FE-7208M D |
---|---|
Adapter: | 100-240VAC, 50/60Hz, 0.7A |
DC Output: | 12V 0.6A |
Rated Power: | 7.2W |
Package Weight: | 3.96 Lbs |
Package Size (LxWxH): | 14.17 x 7.09 x 9.05 inch |
Email: | support@medcursor.com |
CONTROL PANEL
BUTTON | FUNCTION |
---|
BUTTONPOWER
| Press and hold this button for 2 seconds to turn on the device. Thedevice
defaults to Auto Mode with Mid Intensity and Vibration
enabled on first use. It also has a memory function, automatically
restoring previous settings upon next use.
Press and hold it again for 2 seconds to turn off the device.
BUTTONINTENSITY
| Press this button to switch intensity mode.
Massage Strength Intensity: MIN/MID/MAX.
VIBRATEBUTTON
| Press this button to switch vibrate mode.
Vibration Models: M1/M2/M3.
REMARK: This product comes equipped with a convenient status memory function that enables it to automatically record the current working mode, including the massage mode, air pressure intensity and vibration settings. When you switch on the machine again, it will default to these exact settings, saving you time and hassle as you enjoy your massage therapy.
The leg massager runs for 20 minutes each time, then automatically shut off to avoid overheating.
BUTTON | FUNCTION |
---|
M
MODE BUTTON| Press mode button to switch mode. The sequence is as follows
[AUTO]: leg and foot pressure massage
[LEG: Only leg pressure massage .
[FOOT]: Only foot pressure massage
[PINCH]: leg and foot pressure massage
[PRESS】 : leg and foot pressure massage
【RELAX】 :leg and foot pressure massage
Massage intensity shown by number
NOTE:
- Please ensure that you are comfortably seated or lying down when using the device to reduce the risk of falling. The best way to enjoy a massage is in this manner.
PACKAGE CONTENTS
- 1 x Air Compression Leg Massager
- 1 x Controller
- 1 x Portable Bag
- 1 x Adapter
- 1x User Manual
BEFORE FIRST USE
USING THE MASSAGER
- Take the Air Compression Leg Massager and its accessories out of the box they came in, and ensure that all necessary items and accessories are included.
- Check that the fabric is in good condition.
- Sit in a comfortable position and place your legs and feet inside the massager before pressing the control button. Adjust the comfort level to your preference.
- Ensure that the device is working correctly before selecting your preferred massage mode and intensity. Especially if it has not been used for a while, it is recommended to do this.
- The skin may show signs of the boot’s use. Please wear stockings or pants if you are concerned about use-related marks before using the massager. Please be aware that the device may leave use-related marks on the feet, calves, and thighs that may not immediately disappear.
NOTE:
- Do not use it on clothes and trousers with zippers or metal objects. It may damage the product.
OPERATING INSTRUCTIONS
OPERATING PRINCIPLE
The Air Compression leg massager is a sophisticated device consisting of an air pump, two solenoid valves, and air compression boots that work in perfect harmony. The air pump is connected to the air compression boots through air hoses, and each boot has three compression chambers. The massager works by alternating inflation and deflation of these chambers at regular intervals, simulating the kneading and stroking sensations on the foot, calf, and thigh.
The state-of-the-art software controls the timing and the operation of the air pump and solenoid valves, to cycle airflow in and out of the boots. This results in an effective compression massage that can relieve sore muscles and improve circulation.
Overall, the Air Compression leg massager is a fantastic investment for anyone looking for a relaxing and rejuvenating massage experience. Its cutting-edge technology and intelligent design make it a must-have tool for anyone seeking to soothe their aching feet and legs.
HOW TO CONNECT THE CONTROLLER WITH AIR HOSE
As shown above, insert the symbols “UP R” and “UP L” on the hose into the corresponding “UP R” and “UP L” holes in the controller respectively.
NOTE: Ensure that the characters on the hose are facing outward and the “UP L/R” is facing upwards, with corresponding plug holes marked at the bottom of the controller. If the device’s plug is incorrect or loose, it will not generate air pressure.
Tip: You can scan this code or visit http://videoguide.medcursor.com/ to obtain an operating video about how to set this handheld controller.
WEARING ORDER
-
Put the foot into the massager, start from the foot, fix the foot first, and then stick the velcro to the foot-calf-thigh in sequence, as shown below.
There are two velcros on the calf
-
2. There are 2 velcros on the thigh, which can be adjusted according to the individual’s leg circumference.
-
After adjusting the velcro straps on the foot, calf, and thigh, it is simpler to attach the knee strap.
NOTE:
- It is easier to install if you sit on a chair.
- Please be careful when installing to avoid letting the velcro stick to your garments, especially the sweater, or your stockings.
- Turn on the device and take pleasure in the massage after making sure you have donned the boots and the velcro straps are secured to the boots.
FAQS
Under what circumstances should I not use it?
Either during pregnancy or right after delivery. Under the conditions mentioned, it is not advised for patients with severe blood circulation disorders to use the product. Additionally, before using the unit, remember to check with a doctor if you have a fever or any other physical irregularities.
How many times can I use it in a day?
The massager will automatically shut down after 20 minutes of continuous use. We do not recommend using a massager for more than 40 minutes in a day. Prolonged use will over-stimulate muscles and nerves and may have adverse effects.
How does this product work?
There're 3+3 airbags inside the leg massager, which will be inflated and deflated to simulate the kneading and squeezing like human hands. It can relax muscles, increase circulation and relieve fatigue.
Can it be used for other parts than feet, calves, and thighs?
It is only for feet, calves, and thighs. Use in other parts may cause accident or injury.
What size feet, calves and thighs of users are suitable for?
1. Foot width: About 4.7 inches - 6.3 inches (12 cm - 16 cm). 2. Calf circumference: About 12.6 inches -19.7 inches (32 cm - 50 cm). 3. Thigh circumference: About 16.9 inches - 29.9 inches (43 cm - 76 cm)
The strength is too strong or too weak.
The elasticity can be adjusted by the velcro wrap. When the velcro is loosely wound, the overall use strength and pressure will be relatively weakened. Otherwise, the overall intensity and pressure will be relatively strengthened.
The air in the massager hose does not exhaust .
If a lot of air remains in the airbag, it may take some time to exhaust. Unplug the hose and wait for a while for the air to escape naturally.
I can hear some weird sounds on the massager. Is it abnormal?
Velcro sound is crisp: This is the sound of the Velcro slightly opening on the massager (that is the sound of the Velcro being pulled when the air enters the airbag). Buzzing sound: This is the sound produced by the mode effect. These are normal which is caused by the product design of the massager.
Can I use only one leg?
Sorry, it only works when both foot sleeves are connected. We recommend using both to get a better massage, or you can wear only one leg when connected.
NOTE:
- Do not service or perform maintenance on the device while it is in use.
- Maintenance should only be performed by service personnel. Service and maintenance of your device may require repairs, parts, and technical support. As noted at the beginning of the user manual, users should contact the manufacturer or their representative for using or maintaining the product.
CARE & MAINTENANCE
SECURITY AND MAINTENANCE
Never use thinner, benzine, or alcohol (which may cause malfunctions, broken parts, or discoloration, etc.) to clean. Avoid dropping, slamming, or throwing the massager. Do not expose the unit directly to sunlight.
WET THE CLOTH AND WRING IT OUT
If you are worried about dust, please use a neutral detergent that is suitable for use in the kitchen. Dilute it to 5% with warm or clean water and then dampen a soft cloth to clean the surface.
CLEAN
Make sure to turn off the power and unplug the hose. Wipe the inside and outside of the leg massager and remember not to wipe with large force.
NOTE:
- If rubbish or hair is caught in the velcro, remove it with a toothpick etc.
- Do not insert foreign objects into the outlet of the hose plug.
- In order to maintain proper personal hygiene, it is strongly advised to allocate a pair of boots for individual use only
STORAGE
- Attach the Velcro onto the designated positions marked as 23 on the feet, ankles, and calves. Once attached, fold the foot section inward as directed in and fold it again as directed in 5.
- To properly secure the connecting hose, round it and fix it with the velcro of the thigh section as directed in 6.
SAFEKEEPING
Put the unit in a cool, dry place and avoid direct sunlight or high- temperature places.
- Keep out of the reach of children.
- Do not store other objects on the surface of the controller or massager to avoid damaging the device’s surface and to avoid discoloration of the product.
TROUBLESHOOTING
Before requesting repairs, please confirm the following contents, and if errors persist after inspection, please contact your dealer.
CONDITIONS | TROUBLESHOOTING |
---|---|
The unit does not turn on. | Check if the AC adapter is connected. |
Stop working halfway. |
- Check if it is out of power.
- Check whether the hose plug is loose or theconnecting hose is broken.
- The massager will automatically shut down after20 minutes of continuous use.
Air does not enter.| Whether the connecting hose is broken.
Intensity is too weak.|
- Check if the cables or accessories are loose. Make sure to tightly wind the velcro properly.
- If you are wearing thick stockings or pants,this may weaken the intensity of the massager.
Intensity is too strong.|
- Make sure that the attachments are not too tight.
- Try to adjust the velcro to the most comfortable setup.
Air does not de-compress.| Remove the accessory and pull out the hose plugto re-install.
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna..
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
FCC RADIATION EXPOSURE STATEMENT: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. To maintain compliance with FCC RF exposure compliance requirements, please follow operation instructions as documented in this manual. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user.
WARRANTY INFORMATION
TERMS & POLICY
For a period of one year starting from the date of initial purchase, Medcursor Corporation (“Medcursor”) guarantees to the original purchaser that this product will be free from material and workmanship flaws under normal use and conditions. Subject to verification of the defect or malfunction and documentation of the purchase date, Medcursor agrees, at our discretion, during the warranty period to either repair any defect in material or workmanship or provide an equivalent product in exchange without charge.
No other express warranty is provided. This warranty is inapplicable to: • If the product has been modified from its original condition;
- If the product has not been used in accordance with directions and instructions in the user manual;
- To damages or defects caused by accident, abuse, misuse or improper or inadequate maintenance;
- To damages or defects caused by service or repair of the product performed by an unauthorized service provider or by anyone other than Medcursor;
- To damages or defects occurred during commercial use, rental use, or any use for which the product is not intended;
- To damages or defects exceeding the cost of the product.
Medcursor will not be liable for indirect, incidental, or consequential damages in connection with the use of the product covered by this warranty.
This warranty extends only to the original consumer purchaser of the product and is not transferable to any subsequent owner of the product regardless of whether the product is transferred during the specified term of the warranty. This warranty does not extend to products purchased from unauthorized sellers. Medcursor’s warranty extends only to products purchased from authorized sellers that are subject to Medcursor’s quality controls and have agreed to follow its quality controls. All implied warranties are limited to the period of this limited warranty.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
If you discover that your product is defective within the specified warranty period, please contact Customer Support via support@medcursor.com. DO NOT throw the product before contacting us.
Once our Customer Support Team has approved your request, please return the product with a copy of the invoice and order ID.
Every Medcursor product automatically includes a 1-year warranty. To make the customer support process quick and easy, register your product online at www.medcursor.com.
CORRECT DISPOSAL OF THIS PRODUCT(WASTE ELECTRICAL & ELECTRONIC EQUIPMENT
This marking shown on the product indicates that it should not be disposed with other household waste at the end of its life. To prevent potential harm to the environment or to human health, please separate this product from other types of wastes and recycle it responsibly.
When disposing this type of product, contact the retailer where product was purchased or contact your local government office for details regarding how this item can be disposed in an environmentally safe recycling center.
Business users should contact their supplier and check the terms and conditions of the purchasing agreement. This product should not be mixed with other commercial wastes for disposal. This product is free of hazardous materials.
CUSTOMER SUPPORT
- If you have any product questions or concerns, please feel free to contact us directly at support@medcursor.com.
- We have a hassle-free warranty and Medcursor customer service team to provide satisfactory solutions to any problems you may have.
Thank You
Thank you for purchasing Medcursor Air Compression Leg Massager. Medcursor is
dedicated to providing modern and high-quality healthcare products. Should you
have any questions orconcerns about using your massager, feel free to contact
our customer support team at
support@medcursor.com.
We hope you enjoy your new product!
Explore more surprises at
www.medcursor.com
The following pages of this manual are the instructions for all the functions and features of your air compression leg massager. Please read the user’s manual carefully.
@Medcursor
www.medcursor.com
**Symols
**
Documents / Resources
|
MEDCURSOR FE-7208MD Air Compression LEG
Massager
[pdf] User Manual
FE-7208MD, FE-7208MD Air Compression LEG Massager, Air Compression LEG
Massager, Compression LEG Massager, LEG Massager, Massager
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>