IMPORTANT SAFETY INSTRUCTIONS
BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED WHEN USING ELECTRICAL DEVICES. READ ALL SAFETY AND OPERATING INSTRUCTIONS BEFORE USING.
WARNING
- This massager is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of this massager by a person responsible for their safety. Children should be supervised to ensure that they do not play with the massager
- DO NOT use this massager in an excessively humid environment, such as the bathroom.
- DO NOT use this massager on a wet body, this may result in a short circuit or an electric shock.
- DO NOT place or store this massager where it may fall or be pulled into the water
- DO NOT place the controller near electric heaters, stoves, or under direct sunlight.
- DO NOT scratch, damage, bend, pull or twist the power adapter’s power cord. Otherwise, it may result in a fire or an electric shock.
- DO NOT get for the massager when it falls into the water while plugged-in; instead, unplug it first.
- DO NOT use the massager if the electrical outlet is excessively loose. ONLY use the adaptor and attachments supplied with this massager.
- If you detect any malfunction or any other irregularities during operation, switch the power off immediately and contact customer support. It is forbidden to remodel, disassemble or repair the machine without permission.
CAUTIONS
- The following users must consult their doctor before use:
- Using pacemaker or other medical devices which are susceptible to electrical interference;
- Suffering from malignant tumors;
- Suffering from cardiac diseases;
- Having serious peripheral neuropathy dysfunction or sensory disturbance caused by diabetes;
- Being unsuitable to do the massage because of traumas on the body
- Please let the massager rest for 30 minutes after using it, and then perform the second massage. Please control the daily massage time within 20-40 minutes, so that the best massage effect can be obtained.
- STOP using it immediately if you feel unwell. Dont use it again before consulting the doctor.
- Unplug the power adapter from the socket before you clean and maintain it
- Unplug the power adapter when you are not using it.
- DO NOT walk around when you are using this massager or wearing the wraps.
PRODUCT INTRODUCTION
PACKAGE INCLUDED
- 2 x Leg Massager Wraps with Air Hoses
- l x Handheld Controller
- l x Power Adapter DCl 2V 3A
- l x User Manual
SPECIFICATIONS
- Model
- MD-LM0l
- AC/DC Adapter
- AC Input: 100-240 Volts, AC 50/60Hz
- DC Output: 12V 3A
- Rat ed Power
- 36W
- Package Dimensions 1
- 3.5810.044.53 inch
- Net Weight
- 3.31 lbs
- Operating Conditions
- Temperature: +41 ° F to 104° F (5°C to 40°C)
- Humidity : 1 % to 90% non-condensing
- Atmospheric Pressure: 70 kPa to 106 kPa
- Temperature: -4° F to 131 ° F (-20°C to 55°C)
- Storage Conditions
- Humidity : 5% to 90% non-condensing
- Atmospheric Pressure: 50 kPa to 106 kPa
- Keep dry and avoid direct sunlight exposure
KNOW YOUR CONTROLLER
OPERATION INSTRUCTIONS
Cautions: Please read important safety instructions carefully before using the massager. To get a better massage, please wear the sleeves properly.
SET UP
-
Step l: Make sure the inner cover is attached properly.
-
Step 2: Wear the wraps on your legs correctly.
-
Step 3: Fix all the Velcro’s according to your size, don’t wrap too tight.
-
Step 4: Plug the power adapter into the controller and socket.
-
Step 5: Insert two air hose plugs into the controller correctly and completely.
-
Step 6: Take up the controller and press the to start the massager.
- It will begin with mode 1 and low intensity air pressure by default.
- It will shut off after 20 minutes (you can restart it manually).
- The heat function is off by default, you can start it via ( ).
-
Step 7: Press M to switch and enjoy the different massage modes.
Model: Sequence Mode
In this mode, sleeves will be inflated and deflated from lower to upper . Mode 2: Circulation Mode
In this mode, sleeves will be inflated and deflated circularly from lower to upper. Mode 3: Whole Mode
In this mode, sleeves will be inflated and deflated simultaneously and wholly . -
Step 8: Press ( ) button to select intensity.
1. It’s better to start with low intensity air pressure.
2. You can also adjust the intensity by changing the tightness of the wraps. Step 9: Press button to turn the massager off.
NOTES AFTER USE
- Step 10: Unplug the power adapter from the socket.
- Step 11: Pull out the plugs of the power adapter and air hoses from the bottom of the controller.
- Step 12: Take off the wraps, fold them into the box.
FAQS
-
Ql: How does this product massage?
A 1: There are 2+2 airbags inside, which will be inflated and deflated to simulate the kneading and stroking like human hands. It can relax our muscles, increase blood circulation and relieve pains. -
Q2: Why can’t I feel the heat?
A2: The heating function is off by default. You can press (ff!) to turn it on and wait for 3-5 minutes. Please make sure both 2 air hoses are inserted into the controller correctly and completely. -
Q3: What should I do if I feel the temperature is too hot?
A3: Please use the lower temperature or turn it off. It’s better to wear trousers if necessary. -
Q4: What should I do if I feel the massage intensity is too light or too strong?
A4: There are 3 intensities of air pressure to select via the controller, please select the intensity which is fit for you. You can also adjust the intensity by changing the tightness of velcro on the wraps. -
Q5: Why does it not work when I press the button?
AS: Please ensure both 2 air hoses are inserted into the controller, otherwise, it will not work. -
Q6: How long should we use it?
A6: We suggest you use 1 ~2 times every day, and 20 minutes per time. -
Q7: Why does the controller get hot?
A7: If the massager keeps working a too long time, it’s a normal phenomenon that the controller gets hot. It’s better to let the massager rest for 10 minutes. -
QB: Why does the controller make a sound?
AB: The sound comes from the working air pump in the controller, providing air continuously to the airbags in the wraps. It’s a normal phenomenon.
TROUBLESHOOTING
Problems | Causes | Solutions |
---|---|---|
The massager does not work, and the indicator Iight is off. | Disconnected | |
power or lost connection of the adapter. | Make sure the power adapter is |
connected well and press the power button of the controller to start.
The massager does not work, but the indicator light is on.| It works only when
2 air hoses are connected to the controller correctly and completely.| Please
check if the air hoses are inserted correctly (see “UP” mark).
The massager suddenly stops working.| The power adapter or air hoses fall
off.|
Check the plug to ensure inserted in place; Check the air hoses to ensure inserted in place.
Massage time is over (20 mins).| Press®to restart the massager.
Problems| Causes| & Solutions
---|---|---
The air pressure is too light or heavy.| Air pressure intensity is not
suitable.| There are three intensities selectable, and it’s better to start
with low intensity.
The wraps are tied too tight or too loose.| You can adjust the width of the
velcros to make the intensity suitable. Stop the massage if you cannot bear
the intensity.
The controller gets hot.| It is normal if the controller gets hot after
working for a long time.| It is better to shut it down for 10-15 minutes
CARE AND STORAGE
- Make sure to cut off the power when you clean the massager.
- Please wipe the controller, wraps, and hoses with a soft cloth moistened by soap solution when cleaning.
- Toothpicks can be used to remove the hair or chippings attached to the Velcro’s.
- DO NOT use gasoline, alcohol, diluent, or other irritating liquid to wipe the machine. It may cause malfunction, damage, or discoloration of components.
- DO NOT allow foreign matters to enter the hoses.
- DO NOT disassemble the machine by yourself.
- DO NOT place it in high temperature and humidity conditions.
- Avoid direct sunlight.
- Avoid needles puncture the airbags and hoses.
WARRANTY INFORMATION
Med cursor provides all of our customers with a warranty of 12 Months from the
date of purchase.
This guarantee does not cover: damage due to improper use, normal wear or use
as well as defects that have a negligible effect on the value or operation of
the massager. The guarantee becomes void if repairs are undertaken by
unauthorized persons and if original product parts are not used.
- Order ID:
- Date of Purchase: ____ _
*For your own reference, we recommend that you record your order number and date of purchase.
CUSTOMER SUPPORT
Please feel free to contact our Customer Support Team if you have any
questions or concerns regarding your foot massager.
Your satisfaction is our priority.
Visit us at: www.medcursor.com
Contact us at: support@medcursor.com
Please include your Order ID in your email when you are contacting Customer Support for faster solutions.