This product is a fixture that requires electrical installation. It is intended for use in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, it is recommended to have the installation done by a certified electrician. Before assembly, ensure that all parts and part packages are present. If anything is missing, please contact the retailer from which the product was purchased.

Product Usage Instructions

  1. Position the mounting bracket (A) so that the threaded ends of the attached fixture mounting screws (E) are facing out.
  2. Carefully pull the house wires through the large hole in the mounting bracket (A).
  3. Align the holes in the mounting bracket (A) with the holes in the junction box.
  4. Thread each junction box screw (B) into the holes in the mounting bracket (A) and into the holes in the junction box. Tighten the junction box screws (B) to secure the mounting bracket (A) to the junction box. Make sure that the house wires are pulled completely through the hole in the mounting bracket. Avoid pinching wires between the mounting bracket and wall.
  5. Strip 3/4 of insulation from the ends of the fixture wires.
  6. Slightly loosen the ground screw on the mounting bracket (A). Do not completely remove the ground screw. Wrap the house ground wire (copper) around the ground screw, leaving enough ground wire to attach to the fixture ground wire. Twist the end of the fixture ground wire and end of the house ground wire together. Twist the wire connector (C) onto the ends of the wires and completely tighten it.
  7. Twist the end of the house lead wire (black) and end of the fixture lead wire together. Twist the wire connector (C) onto the ends of the wires and completely tighten it. Twist the end of the house neutral wire (white) and end of the fixture neutral wire together. Twist the wire connector (C) onto the ends of the wires and completely tighten it.
  8. Wrap electrical tape (not included) around the wire connectors (C) and wires to ensure they are securely fastened.
  9. Carefully push all wires and wire connectors into the junction box.
  10. Place the backplate (D) over the mounting bracket (A). Pass the holes in the backplate (D) over the ends of the fixture mounting screws (E). Avoid pinching any wires.

For further assistance or any questions, please call:
800-613-3261 (Monday to Friday, 8:00 AM to 6:00 PM ET).

Wire Connections Reference Chart

Connect Supply (House) Ground Copper Wire to:| Connect Black Lead Supply (House) Wire to:| Connect White Neutral Supply (House) Wire to:
---|---|---
Bare Copper Wire| Black Wire| White Wire
Bare Silver Wire| Parallel Cord (Round and Smooth)| Parallel Cord (Square and Ridged)
Green Insulated Wire| No printed words on wire insulation| Printed words on wire insulation
| Insulated Wire (other than green) with Copper Conductor| Insulated Wire (other than green) with Silver Conductor

*When parallel wire (SPT 1 & SPT 2) is used: The lead wire is round in shape or smooth. The neutral wire is square in shape or ridged.

For additional information and support, visit elkhome.com.

WARNING: DISCONNECT POWER AT THE MAIN FUSE BOX BEFORE INSTALLATION.
WARNING
This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Before assembly, remove all parts and part packages from box. If anything is missing, please contact the retailer from which the product was purchased.

INSTALLATION INSTRUCTIONS

  1. Position mounting bracket (A) so threaded ends of attached fixture mounting screws (E) are facing out.
  2. Carefully pull house wires through large hole in mounting bracket (A).
  3. Align holes in mounting bracket (A) with holes in junction box.
  4. Thread each junction box screw (B) into holes in mounting bracket (A) and into holes in junction box. Tighten junction box screws (B) to secure mounting bracket (A) to junction box. CAUTION: Make sure house wires are pulled completely through hole in mounting bracket. DO NOT pinch wires between mounting bracket and wall.
  5. Strip 3/4” of insulation from ends of fixture wires.
  6. Slightly loosen ground screw on mounting bracket (A). Do not completely remove ground screw. Wrap house ground wire (copper) around ground screw, leaving enough ground wire to attach to fixture ground wire. Twist end of fixture ground wire and end of house ground wire together. Twist wire connector (C) onto ends of wires. Completely tighten wire connector (C). Reference chart below for correct wire connections.
    Connect Supply (House) Ground Copper Wire to:

    Bare Copper Wire or,
    Bare Silver Wire or,
    Green Insulated Wire.

  7. Twist end of house lead wire (black) and end of fixture lead wire together. Twist wire connector (C) onto ends of wires. Completely tighten wire connector (C). Twist end of house neutral wire (white) and end of fixture neutral wire together. Twist wire connector (C) onto ends of wires. Completely tighten wire connector (C). Reference chart to the right for correct wire connections.
  8. Wrap electrical tape (not included) around wire connectors (C) and wires. Ensure wires are securely fastened into wire connectors.
  9. Carefully push all wires and wire connectors into junction box.
    Connect Black Lead Supply (House) Wire to:| Connect White Neutral Supply (House) Wire to:
    ---|---
    Black Wire or,| White Wire or,
    Parallel Cord (Round and Smooth) or,| Parallel Cord (Square and Ridged) or,
    No printed words on wire insulation or,| Printed words on wire insulation or,
    Insulated Wire (other than green)

with Copper Conductor.

| Insulated Wire (other than green)

with Silver Conductor.

*When parallel wire (SPT 1 & SPT 2) is used: The lead wire is round in shape or smooth. The neutral wire is square in shape or ridged.

elk-HOME-144272-2-Light-Vanity-Lamp-FIG-3

  1. Place backplate (D) over mounting bracket (A). Pass holes in backplate (D) over ends of fixture mounting screws (E). CAUTION: Do not pinch wires between backplate and wall.

  2. Screw one threaded cap (F) onto end of each fixture mounting screw (E). Tighten both threaded caps (F) to secure fixture (D) to wall.
    DO NOT over tighten.

  3. Screw recommended bulbs (E26 Edison bulb type, not included) into sockets. Verify correct bulb wattage marked on socket of fixture.
    WARNING: DO NOT exceed maximum bulb wattage.

  4. Raise shade (K) up to fixture. Pass hole in top of shade (K) over bulb. Fit top of shade (K) inside socket cup.

  5. Holding shade (K) in place, thread one thumbscrew (L) into each hole in edge of socket cup. Do not completely tighten thumbscrews (L) until all thumbscrew (L) have been installed. After all thumbscrews (L) have been installed, equally tighten thumbscrews (L) to secure shade (K) in place. DO NOT over tighten thumbscrews (L).

  6. Repeat steps 13 and 14 to install remaining shade (K).

elk-HOME-144272-2-Light-Vanity-Lamp-FIG-4

elkhome.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

elk HOME User Manuals

Related Manuals