COSTWAY ES10103US-WH Moisture Absorber Dehumidifier User Manual
- June 13, 2024
- COSTWAY
Table of Contents
COSTWAY ES10103US-WH Moisture Absorber Dehumidifier
Before You Start
- Please read all instructions carefully.
- Retain instructions for future reference.
- Separate and count all parts and hardware.
- Read through each step carefully and follow the proper order.
- We recommend that, where possible, all items are assembled near to the area in which they will be placed in use, to avoid moving the product unnecessarily once assembled.
- Always place the product on a flat, steady and stable surface.
- Keep all small parts and packaging materials for this product away from babies and children as they potentially pose a serious choking hazard.
Please keep this manual carefully for further reference!
Thank you for selecting our dehumidifier. Be sure to read this manual carefully before using it. Any questions, please contact our customer for help.
BEFORE YOU BEGIN
Please read the operating instructions carefully before using your dehumidifier for the first time.
PRODUCT DESCRIPTION
The dehumidifier is used to remove excessive moisture from the air.
The resulting reduction in relative humidity protects buildings and their
contents from the adverse effects of excess humidity.
FOR YOUR SAFETY
Your safety is the most important thing we concerned!
CAUTION: Please read this manual carefully and fully understand before operating your dehumidifier.
OPERATIONAL PRECAUTIONS
WARNING- To reduce the risk of fire, electric shock or injury to persons or property:
- If the supply cord is damaged, it must be replaced by the manufacturer, in order to avoid a hazard.
- The appliance shall be disconnected from its power source during maintenance.
- Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
- Always use a power outlet that is grounded.
- Unplug the power cord when cleaning or when not in use.
- Do not operate with wet hands. Prevent water from spilling onto the unit.
- Do not immerse or expose the unit to rain, moisture or any other liquid.
- Do not leave the unit running unattended. Do not tilt or turn over the unit.
- Do not unplug while the unit is operating.
- Do not unplug by pulling on the power cord.
- Do not use an extension cord or an adapter plug.
- Do not put objects on the unit.
- Do not climb or sit on the unit.
- Do not insert fingers or other objects into the air outlet.
- Do not touch the air inlet or the aluminum fins of the unit.
- Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
- Do not clean the appliance with any chemicals.
- Ensure the unit is far away from fire, inflammable, or explosive objects.
- The unit shall be installed in accordance with national wiring regulations.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- Do not piece or burn, even after use.
- Be aware that refrigerants may not contain an odour.
- Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than 43 sq.ft.
- Compliance with national gas regulations shall be observed.
- Keep any required ventilation openings clear of obstruction.
- The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation. L’h, Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry, recognized assessment specification.
PRODUCT OVERVIEW
INSTALLATION
LOCATION
- Place the unit on a firm, level surface in an area with at least 12 inch of free space around it to allow for proper air circulation.
- Never install the unit where it could be subject to:
- Heat sources such as radiators, heat registers, stoves or other products that produce heat;
- In an area where oil or water may be splashed;
- Direct sunlight;
- Mechanical vibration or shock;
- Excessive dust;
- Lack of ventilation, such as cabinet or bookcase;
- Uneven surface.
OPERATING THE DEVICE SAFELY
- Check the device after unpacking for any damages or scratches on it.
- Operate this unit at an ambient temperature from 41 ° F to 95° F.
- Do not use in outdoors. This dehumidifier is intended for indoor residential applications only.
- Do not operate in close proximity to walls, curtains, or other objects that may block the inlet and outlet.
- Keep the air inlet and outlet free of obstacles.
- Adjust the wind deflector in the upward direction prior to start-up.
- If tipped more than 45 °, allow the unit to set upright for at least 24 hours before start-up.
- Keep doors and windows closed for better energy saving.
- Do not operate or store the unit in direct sunlight or rain.
- It is normal for the air outlets to feel warm to the touch after a continuous operation on hot days.
- Empty the water tank before moving the device.
- Make sure the Water tank is correctly fitted otherwise the unit will not operate properly.
- The dehumidifier starts up in the mode selected when the unit was last used.
- The dehumidifier starts dehumidifying if the room humidity is 3% higher than the selected humidity.
- There is a protective 3-minute time delay of the compressor. Wait 3 minutes for the dehumidifier to resume dehumidification.
OPERATION
CONTROL PANEL
POWER
In the standby state, press the power button to turn on, the operation
indicator lights up and the default fan speed is high, and the default
humidity is 50%. In the power-on state, press the power button to turn off,
the running indicator light goes off and the compressor stops immediately, and
then the fan shuts down after 30 30-second delay.
MODE
Auto mode – continuously drying mode – sleeping mode cycle, press once to switch the mode from one to another, the corresponding indicator lights up.
- Auto mode: When environmental humidity set humidity +3%, the fan starts working and the compressor starts working after 3 seconds.
When environmental humidity: 5 set humidity -3%, the compressor stops working and the fan stops working after 30 seconds’ delay.
Both fan speed and humidity can be adjusted under auto mode.
Note : When the unit defrosts under this mode, the indicator lights up.
• Continuously drying mode: In continuous operation, the unit works
continuously without control by humidity until the water tank is full or the
dehumidifier is switched off manually.
During operation, the current humidity is shown on the display.
Note: When the unit defrosts under this mode, the indicator lights up.
- Sleeping mode: Long press the mode button, the sleep indicator lights up and it starts the sleep function. After no operation in 10 seconds, all indicators turn dark gradually and the wind speed is automatically switched from high to low. Touch any button to wake up the indicator. Touch the mode button again to exit the sleep mode.
When environmental humidity: 5 57%, the compressor stops working, and the
The fan shuts down after 30 seconds’ delay.
When environmental humidity 63%, the fan starts working and the compressor starts working after 3 seconds.
Fan speed and humidity can not be adjusted under sleeping mode.
HUMIDITY SET
Touch the humidity button to check the current environment humidity, touch this button again and you can set the humidity. The range of target humidity is 30%- 35% – 40% – 45% – 50% – 55%- 60% – 65% -70% – 75%- 80%. After setting 3 seconds, the system confirms the input value, and then the machine exits the setting state, and returns the current humidity. In the drying mode, the target humidity cannot be changed. Hold this button for 3 seconds to display the current ambient temperature
TIMER
Press the timer button to active the timing function , then press the 12; to
set the time. The interval is 1 hour. Each time you press this button, the
value increases 1 hour and then the corresponding timing value is displayed on
the screen. The setting value is “DO” to cancel the timer function. The
indicator turns out. After the timer is set and completed, the timer LED is on
during the timing period. After the timing is over, the timer LED turns off
automatically. In the running state, set the time to turn off the machine; In
the standby state, set the time to turn on the machine.
SPEED
High wind – low wind cycle, press the button once to switch the speed and then
the corresponding indicator lights up. In sleep mode and defrosting period,
the wind speed can not be changed.
CHILD-LOCK
Hold the child lock button to turn on or off the child lock function, the lock indicator mj lights up accordingly.
3 Color Digital Display:
- Ambient Humidity<45%, The light shows Blue; 45:5Ambient Humidity:565%, The light shows Green; Ambient Humidity>65%, The light shows Red;
- If the LED displays El, CL, CH, LO the light will show red.
DRAINAGE:
EMPTYING THE WATER TANK
- When the tank is full, The unit will make a buzzing sound, and the “FT” light will turn on.
- Press the POWER button to turn off the unit.
- Pull on the water tank and simply slide out of the body of the dehumidifier.
- Empty the water into an area with a drain or outside.
- Clean the inside of the tank as well as the outside.
- Replace the empty tank back into the unit.
- Press the POWER button to resume operating.
- If the Water Full light does not extinguish, check that the float is correctly in place.
Warning
- Do not discard water tank magnets and plastic rivets. Otherwise, the machine will not automatically stop working when the water tank is full, and the condensed water will overflow and damage the floor of the room.
- Please be sure to clean the condensed water in the water tank before resetting the working mode of the machine.
- If the water tank is dirty, rinse it with clean water. Avoid using detergents, steel balls, chemical dust removers, diesel oil, benzene, diluent or other solvents. Otherwise, the water tank will be damaged and leak.
- Replace the empty tank back into the unit. Otherwise, the water full indicator may remain red and the machine cannot restart
CONTINUOUS DRAINING
For continuous operation or unattended dehumidification, please connect the
attached drain hose to the unit. Condensate water can be automatically flow
into a bucket or drain by gravity.
- Straighten the drainage pipe
- Insert one end of the drain into the cistern hole and connect the other end to the bathroom, outdoor or bucket like container, or the prescribed drainage area.
Warning
- Please do not block the drain or drain pipe. If the phenomenon of blocking occurs, condensed water will flow into the water tank.
- Please do not bend the drain pipe. The height of the drain pipe should be lower than the outlet.
- The drain pipe shall be securely connected to the outlet;
MAINTENANCE
Note: before cleaning and maintaining the machine, be sure to turn off the machine and pull the power plug to prevent electric shock.
CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted
airflow reduces the efficiency of the system and if it becomes blocked it can
cause damage to the unit.
The air filter requires regular cleaning. The air filter is removable for easy
cleaning. Do not operate the unit without an air filter, or the evaporator may
be contaminated.
-
Take the water tank from the body, and then pull out the filter from the back shell;
-
Use a vacuum cleaner to gently absorb the dust on the surface.
If the filter is very dirty, wash it with water and a soft detergent and dry it thoroughly afterward. -
Put the filter back.
TROUBLESHOOTING
FUNCTIONING TEMP.
- 41 °Fs Ambient Temp. s 95° F
- When the ambient temp. is lower or higher than the functioning temp., the dehumidifier stops.
- When 41 ° F s Ambient temp. s 60.8° F, the compressor automatically defrosts at intervals; during defrosting, the compressor stops and the fan keeps running.
BEFORE CALLING FOR SERVICE
Before contacting professional service, please review the trouble shooting
list that includes common occurrences that are not the result of a defect in
workmanship or materials.
STORAGE & DISPOSAL
STORAGE
Long-term storage – If you will not be using the unit for an extended period
of time (more than a few weeks) it is best to clean the unit and dry it out
completely. Please store the unit per the following steps:
- Press power button to switch off and unplug the unit.
- Drain the remaining water from the unit.
- Clean the filter and let the filter dry completely in a shaded area.
- Collect the power cord at the water tank.
- Re-install the filter at its position.
- The unit must be kept in upright position when in storage.
- Preserve the machine in ventilating, dry, non-corrosive gas and safe place indoor.
ATTENTION
The evaporator inside the machine has to be dried out before the unit is
packed to avoid component damage and molds. Unplug the unit and place it in a
dry open area for days to dry it out. Another way to dry the unit is to set
the humidity point more than 5% higher than the ambient humidity to force the
fan to dry the evaporator for a couple of hours.
DISPOSAL
WARNING: Releasing refrigerant into atmosphere is strictly forbidden! Do
not dispose of electrical appliances as unsorted municipal waste, use separate
collection facilities. Contact your local government for information regarding
the collection systems available. If electrical appliances are disposed of in
landfills or dumps, hazardous substances can leak into the groundwater and get
into the food chain, damaging your health and well-being.
Contact Us
Do NOT return this item.
Contact our friendly customer service department for help first.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>