Systemair IHW15 Infrared Heater Patio Heaters Instruction Manual
- June 13, 2024
- systemair
Table of Contents
- Systemair IHW15 Infrared Heater Patio Heaters
- Dimensions
- Accessories
- Technical specifications
- Wiring diagrams
- Assembly and operating instructions
- Maintenance
- Safety
- Translation for introductory pages
- Wiring diagrams
- Technical specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Systemair IHW15 Infrared Heater Patio Heaters
The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages.
Dimensions
Wall bracket
IHE (18050)
Positioning
Installation height
- Fig.1: The heaters should heat from at least two directions for even heating
Minimum mounting distance
Replacing the lamp
Accessories
- 11884 IHUB*
- 18050 IHE
- 16975 IHXH*
- 16976 IHXL*
- 11887 IHT*
- 16974 IHTW*
- 16970 IHP*
- 92865 KLS1KS
- 93272 IHAF
- 220646 IHL1000
- 220647 IHL1500
- 206496 IHL2000
- See separate manual.
Controls
- 92867 IHBD3*
- 10740 CBT
- See separate manual.
Technical specifications
Infrared heater IHW with wide heat distribution (IP44)
Item number| Type| Heat output [W]| Voltage
[V]
| Amperage
[A]
| Max. filament temperature [°C]| Length
[mm]
| Weight
[kg]
---|---|---|---|---|---|---|---
11878| IHW10| 1000| 230V~| 4,3| 2200| 500| 1,9
11879| IHW15| 1500| 230V~| 6,5| 2200| 500| 1,9
11880| IHW20| 2000| 230V~| 8,7| 2200| 676| 2,5
Infrared heater IHF with directed heat distribution (IP44)
Item number| Type| Heat output [W]| Voltage
[V]
| Amperage
[A]
| Max. filament temperature [°C]| Length
[mm]
| Weight
[kg]
---|---|---|---|---|---|---|---
11881| IHF10| 1000| 230V~| 4,3| 2200| 500| 1,9
11882| IHF15| 1500| 230V~| 6,5| 2200| 500| 1,9
11883| IHF20| 2000| 230V~| 8,7| 2200| 676| 2,5
Wiring diagrams
Timer control
Timer control with contactor
Assembly and operating instructions
General instructions
Read these instructions carefully prior to installation and use. Keep this
manual for reference purposes. The product may only be used used as described
in the installation instructions operating instructions. The warranty applies
only if the product is used on the intended manner and in accordance with the
instructions.
Application
The halogen infrared heater IH is powerful with a surface temperature of 2200
°C. IH is the perfect choice for those outdoor environments where design is
important is. IH is available in two different ones designs. The IHW takes
care of one up close comfortable warmth in the living area and also ensures
further heat distribution. The IHF has direct heat distribution and is
designed for higher mounting. Protection class: IP44.
Placement
The infrared heaters must be placed around the area heating area can be placed
(see figure 1). The units become normal spoken 2-3 m above the ground/floor
placed. In general it applies to infrared heaters that 600–800 W/m² the
temperature increases by about 10 °C. The capacity requirement can be limited
as the area to be heated is walled. If the area has only a roof is minimal 800
W/m² required. 600 W/m² is sufficient if the area has 3 walls. For walled
areas must become the capacity requirement calculated. Achieves optimal
comfort u as the heat from two directions is being devided. IHW provides one
wide heat distribution (60°), recommended installation height 1.8–2.5 m. IHF
ensures for targeted heat distribution (40°), recommended installation height
2.3–3.5 m.
Edit
The IH installed horizontally on walls using the supplied bracket. The heater
can reach a maximum temperature of 45° tilted. The radiator can also be
mounted in for example a parasol or on a rod, a suitable U-bolt (not
included). for this used together with the delivered console. Make for
installation on the ceiling use of ceiling bracket IHE (accessory). For other
mounting options, see accessories. See the diagrams on the introductory pages
for the minimum distance.
- Install the bracket with minimum 2 screws on the wall. As the keyhole slots are used, there is one additional screw required for mounting clamp. See the introductory pages.
- Remove the screws included in delivery are at the back of the unit confirmed.
- Hook the unit onto the bracket.
- Position with the screws.
Connection
The IH is equipped with a 0.9 meter long cable with plug for connection to a
grounded socket. The connecting cable maynot rest against the unit, as it
surface becomes hot or due to thermal radiation can be hit. Contact us with an
electrician as the cord must be replaced. Because of the high temperatures in
the radiant heater must be a cord type H05 RN-F 3G1 mm² or are used similarly.
Since the halogen lamp has a high starting current, the wall socket must be
connected to a slow fuse are protected. When in doubt, take it contact an
electrician.
Boot up
When using the unit for the first time or after a longer period of time period
of downtime is used smoke or odor occurs as a result dust or dirt remaining on
the element. This is completely normal and will clear up after a short time to
disappear.
Replace the lamp
The heat lamp is of the very best quality and has a long lifespan, unless it
is exposed to mechanicalloads in the form of vibrations and shock. The
lifespan depends the ambient temperature and the way on which the radiant
heater is installed. If the radiant heater is free and outdoors is installed,
the temperature will be low are and is the expected life of the lamp about
3000 hours. The lamp must go on an installer or other skilled person person is
replaced.
- Disconnect the power supply.
- Wait until the unit is cold.
- Remove the covers on both ends (four screws).
- Pull the grille to one side.
- Remove both reflector ends (two screws).
- Make the connections to the terminal block loose.
- Pull the lamp out of the lamp holders.
- Check that the replacement lamp is working has the correct power and voltage.
- Install the new lamp. Do not touch the lamp with your fingers and wear gloves or something similar.
- Place the protective tube back on the cables, so that the cables are not damaged touch when installing the grille.
- Mount the unit. See the introductory pages.
Maintenance
During all service, repair and maintenance work requires the power supply to the unit are disconnected. Guard until the unit is cold. The unit has no moving parts little maintenance is required. You have tothe unit clean and free from dust and are kept dirty. Like the reflector is not clean, takes the thermal radiation from the unit and will cause the radiant heater become warmer. A lot of dirt is possible lead to overheating. The surface of the reflector is sensitive and should be carefully.being cleaned. If the reflector is dirty it must be checked by a specialist cleaned or replaced.
Packaging
Packaging materials are selected with attention to the environment and are
therefore recyclable.
Handling of product at the end of the life cycle
This product may contain substances that are necessary for it to be correct
functioning of the product, but that potentially harmful to the environment.
The product is not allowed with the general household waste is done, but must
be delivered to a special collection point for environmentally responsible to
recycle. Please contact your local authorities for further information about
it nearest collection point for you.
Safety
- For all electrical installations heated products must have a Residual current circuit breaker of 300 mA for fire protection is used.
- The unit may not be used in whole or in part be covered because overheating can lead to a fire hazard!
- The device should not be placed directly under a socket must be installed!
- The unit must not be used at damage to the unit or connection. Chances of damage!
- The radiant heater is equipped with a protective grille to prevent contact prevent and to avoid major objects come into contact with the hot lamp. The unit should not be without this protective grille is used.
- The cable and plug must be located outside the warm radiation area.
- This device can be used by children from 8 years and by persons with limited physical, sensory or mental capacities or persons who lack knowledge or experience provided that they are supervised or have adequate instructions learned about the safe use of it device and its possible dangers to understand. Children are not allowed with it play device. Cleaning and maintenance of the device may not be exported by children, unless they are supervised to stand.
- Children under 3 years of age must be kept at a distance to be held unless they are continuously are under supervision.
- Children between the ages of 3 and 8 are allowed to do this only switch the device on and off, provided it is placed and installed in its normal operating position intended for this purpose. They must also be supervised or to have been instructed regarding it safely use of the device, and aware of the associated risks.
- Children between 3 and 8 years old are allowed device do not connect, regulate and cleaning or user maintenance to carry out.
WARNING— Some parts of this product can become very hot and cause burns. Special needs attention should be paid to places where children and vulnerable persons present.
Translation for introductory pages
- Dimensions
- Wall bracket
- Positioning
- The heaters should heat from at least two directions for even heating
- Installation height
- Minimum distance
- Flammable material
- IHE, ceiling bracket
- Replacing the lamp
- Accessories
- See separate manual.
- Controls
- Dimensions
- Wall bracket
- Placement
- The radiators must be used for uniformity heating from at least two work directions.
- Installation height
- Minimum distance
- Flammable material
- IHE, ceiling bracket
- Replace the lamp
- Accessories
- See separate manual
- Arrangements
Wiring diagrams
- Timer control = Timer control
- Timer control with contactor =Timer control with magnetic switch
Technical specifications
- Wiring diagrams Infrared heater IHF with concentrated heat distribution (IP44)
- Infrared heater IHW with wide heat distribution (IP44)
- Item number Article number
- Type Type
- Heat output [W] Heating capacity
- Voltage [V] Voltage
- Amperage [A] Amperage
- Max. filament temperature [°C] Max. filament temperature
- Length [mm] Length
- Weight [kg] Weight
- mailbox@frico.se
- www.frico.net
For latest updated information and information about your local contact: www.frico.net
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>